11 resultados para Power to gas
Resumo:
Thesis submitted in Trinity Term 2001 for the degree of Master of Philosophy, Worcester College, Oxford
Resumo:
Modern fully integrated transceivers architectures, require circuits with low area, low cost, low power, and high efficiency. A key block in modern transceivers is the power amplifier, which is deeply studied in this thesis. First, we study the implementation of a classical Class-A amplifier, describing the basic operation of an RF power amplifier, and analysing the influence of the real models of the reactive components in its operation. Secondly, the Class-E amplifier is deeply studied. The different types of implementations are reviewed and theoretical equations are derived and compared with simulations. There were selected four modes of operation for the Class-E amplifier, in order to perform the implementation of the output stage, and the subsequent comparison of results. This led to the selection of the mode with the best trade-off between efficiency and harmonics distortion, lower power consumption and higher output power. The optimal choice was a parallel circuit containing an inductor with a finite value. To complete the implementation of the PA in switching mode, a driver was implemented. The final block (output stage together with the driver) got 20 % total efficiency (PAE) transmitting 8 dBm output power to a 50 W load with a total harmonic distortion (THD) of 3 % and a total consumption of 28 mW. All implementations are designed using standard 130 nm CMOS technology. The operating frequency is 2.4 GHz and it was considered an 1.2 V DC power supply. The proposed circuit is intended to be used in a Bluetooth transmitter, however, it has a wider range of applications.
Resumo:
Dissertação submetida para obtenção do grau de Doutor em Saúde Pública Especialidade de Economia da Saúde
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Finance from the NOVA – School of Business and Economics
Resumo:
RESUMO: Introdução: A obstrução da via aérea central (OVAC) refere-se a um processo patológico que conduz a limitação do fluxo de ar ao nível do espaço glótico e subglótico, traqueia e brônquios principais. O seu correcto diagnóstico e tratamento constituem um território de interesse e preocupação para os profissionais de saúde, e requerem um profundo conhecimento da sua etiologia, fisiologia, diagnóstico e opções terapêuticas dado o potencial em originar significativa morbilidade e mortalidade. A avaliação da OVAC abrange múltiplas vertentes, entre as quais se salienta o componente clínico (sinais e sintomas), a repercussão fisiopatológica (função respiratória) e o estudo imagiológico (TC do tórax e broncoscopia). A compilação destes dados associada à etiologia, constituem factores importantes para estabelecer o prognóstico, determinar a necessidade de tratamento ou delinear uma futura intervenção terapêutica. A broncoscopia é o Gold Standard de avaliação desta condição, mas desde há cerca de 40 anos a curva de débito-volume constitui uma ferramenta não invasiva de detecção de OVAC. Apesar deste método ser utilizado até os nossos dias, poucos têm sido os estudos com o objectivo de verificar a sensibilidade e especificidade da curva de débito-volume na detecção de OVAC, bem como averiguar a relação entre as alterações morfológicas e quantitativas da mesma com a localização, o tipo e o grau da obstrução. Material e Métodos: Entre 1 de Novembro de 2009 e 30 de Abril de 2010, os doentes com indicação para a realização de broncoscopia diagnóstica ou terapêutica na Unidade de Técnicas Invasivas Pneumológicas (UTIP) do Centro Hospitalar Lisboa Norte – Hospital Pulido Valente (CHLN – HPV) foram seleccionados de forma consecutiva de acordo com os critérios de inclusão e exclusão. As avaliações (broncoscopia, curva de débito-volume e avaliação da dispneia) realizaram-se com um intervalo de tempo máximo de sete dias. A broncoscopia flexível foi realizada segundo as normas da British Thoracic Society e as curvas de débito-volume segundo as normas da ATS/ERS TaskForce 2005. Para a avaliação da dispneia recorreu-se à escala de dispneia MRC (Medical Research Council). Um painel de peritos realizou a avaliação da morfologia da curva de débito-volume (sugestiva ou não de OVAC) e um elemento independente a verificação dos critérios quantitativos e morfológicos (variáveis intra e extratorácica e fixa) da curva. O estudo foi aprovado pela Comissão de Ética para a Saúde do CHLN e todos os doentes assinaram um consentimento informado de participação. Resultados: Estudaram-se 82 doentes, 36 (44%) dos quais com OVAC. A predominância foi do género masculino, em relação ao feminino. A sensibilidade e especificidade dos critérios quantitativos da curva de débito-volume na detecção de OVAC foi de 91.3% e 88.9% respectivamente. Quando se utilizaram os critérios morfológicos da curva de débito-volume os valores foram de 93.5% e 30.6%. A agregação dos critérios morfológicos e quantitativos permitiu alcançar uma sensibilidade de 95.7% e especificidade de 86.1%. Nesta amostra, o critério quantitativo com maior ocorrência foi o FEF50/FIF50≥1 (83% dos doentes com OVAC). Este mostrou relacionar-se com todas as localizações de obstrução excepto o terço médio da traqueia. Mostrou, ainda, ter uma relação forte e positiva com o grau e tipo de obstrução (intra e extraluminal). O segundo foi o FEV1/PEF≥8, presente em 36% dos casos de OVAC. Relacionou-se com as obstruções no terço inferior da traqueia e brônquio principal direito (BPD). Também apresentou relação forte e positiva com o grau de obstrução e com os tipos de obstrução anteriormente descritos. Quanto à sintomatologia foi possível associar o grau de obstrução com o de dispneia e a presença de estridor com o grau e localização da obstrução na traqueia. Conclusões: Os resultados deste estudo demonstram que os critérios quantitativos da curva de débito-volume têm elevada sensibilidade e especificidade na detecção de OVAC. O critério FEV50/FIF50≥1 tem um bom poder discriminativo na detecção dessa condição, tendo sido relacionado com a localização, o grau e o tipo de obstrução. O critério FEV1/PEF≥8, embora com menor poder discriminativo, também se relaciona com o grau, a localização e o tipo de obstrução. A morfologia da curva tem uma boa sensibilidade mas baixa especificidade na detecção de OVAC, mas a agregação entre os critérios morfológicos e quantitativos aumenta a sensibilidade e especificidade. A dispneia e o estridor foram relacionados com o grau de obstrução e o último com a localização ao nível da traqueia.-------------ABSTRACT: Introduction: Central airway obstruction (CAO) refers to a pathological process that leads to restriction of airflow at the level of the glottis and subglottis, trachea and main bronchi. It’s proper diagnosis and treatment is an area of interest and concern to health professionals, and requires a deep knowledge of its etiology, physiology, diagnosis and treatment options, concerning the potential to cause significant morbidity and mortality. The evaluation of CAO covers multiple aspects: the clinical component (signs and symptoms), the pathophysiological effect (lung function) and the imaging study (bronchoscopy and chest CT). The compilation of this data associated with the etiology, are important for establishing prognosis, determine the need for treatment or outline a future therapeutic intervention. Bronchoscopy is the gold standard for evaluating this condition, but for the last 40 years the flow-volume loop has been used as a noninvasive tool for detecting CAO. Although this method is still in use, only few studies were made in order to verify its sensitivity and specificity in detecting CAO, and investigate the relation between morphological and quantitative changes of the curve to location, type and degree of obstruction. Methods: Between 1st November 2009 and 30th April 2010, patients with indication to perform diagnostic or therapeutic bronchoscopy in Interventional Pulmonology Unit - Hospital Pulido Valente (CHLN - HPV), were selected consecutively according to the inclusion and exclusion criteria. All assessments (bronchoscopy, flow-volume loop and dyspnea) were carried out within a period of seven days. The flexible bronchoscopy was performed according to the standards of the British Thoracic Society and the flow-volume loops in accordance with the standards of the ATS / ERS Taskforce 2005. For the evaluation of dyspnea was used to MRC dyspnea scale (Medical Research Council). A panel of experts evaluated the morphology of flow-volume loop (suggestive or non-suggestive of CAO) and an independent element established the quantitative criteria and morphological (intra and extrathoracic variables and fixed) of the curve. This study was approved by the Ethics Committee for Health CHLN and all the patients signed an informed consent to participate. Results: We’ve studied 82 patients, 36 (44%) of those with CAO. The majority of the patients were males, compared to females. The sensitivity and specificity of the quantitative criteria of the flow-volume curve in detecting CAO was 91.3% and 88.9% respectively. When we used the morphological criteria of flow-volume loop these values were 93.5% and 30.6%. The combination of quantitative and morphological criteria produced values of 95.7% sensitivity and 86.1% specificity. FEF50/FIF50≥1 was the most representative quantitative criterion (83% of patients with CAO) and it was correlated with all sites of obstruction except in the middle third of the trachea. It has shown a strong and positive association with the degree and type of obstruction (intra and extraluminal). The second was the FEV1/PEF ≥ 8, present in 36% of cases of CAO. It could be correlated with the obstruction in the lower third of the trachea and right main bronchus. It also showed a strong positive relation with the degree and types of obstruction described above. Regarding symptoms, we found a link between the degree of obstruction and dyspnea. The presence of stridor was correlated with the location and the degree of obstruction in the trachea. Conclusion: The results of this study demonstrate that the quantitative criteria of the flow-volume loop have a high sensitivity and specificity in detecting CAO. The criterion FEV50/FIF50 ≥ 1 has a good discriminative power to detect this condition and was related to the location, degree and type of obstruction. The criterion FEV1/PEF ≥ 8, although with a weaker discriminative power, also relates to the degree, location and type of obstruction. The morphology of the curve has a good sensitivity but low specificity in detecting CAO although the combination between the morphological and quantitative criteria increases sensitivity and specificity. Dyspnea and stridor were related to the degree of obstruction and the last one with its location in the trachea.
Resumo:
In cataract surgery, the eye’s natural lens is removed because it has gone opaque and doesn’t allow clear vision any longer. To maintain the eye’s optical power, a new artificial lens must be inserted. Called Intraocular Lens (IOL), it needs to be modelled in order to have the correct refractive power to substitute the natural lens. Calculating the refractive power of this substitution lens requires precise anterior eye chamber measurements. An interferometry equipment, the AC Master from Zeiss Meditec, AG, was in use for half a year to perform these measurements. A Low Coherence Interferometry (LCI) measurement beam is aligned with the eye’s optical axis, for precise measurements of anterior eye chamber distances. The eye follows a fixation target in order to make the visual axis align with the optical axis. Performance problems occurred, however, at this step. Therefore, there was a necessity to develop a new procedure that ensures better alignment between the eye’s visual and optical axes, allowing a more user friendly and versatile procedure, and eventually automatizing the whole process. With this instrument, the alignment between the eye’s optical and visual axes is detected when Purkinje reflections I and III are overlapped, as the eye follows a fixation target. In this project, image analysis is used to detect these Purkinje reflections’ positions, eventually automatically detecting when they overlap. Automatic detection of the third Purkinje reflection of an eye following a fixation target is possible with some restrictions. Each pair of detected third Purkinje reflections is used in automatically calculating an acceptable starting position for the fixation target, required for precise measurements of anterior eye chamber distances.
Resumo:
For some years, researchers could not find a clear effect of capital adequacy on the risk profile of banks, as shareholders could increase the riskiness of the assets (qualitative effect), crowding-out the effect of reduced leverage (volume effect). Some shareholders might have the will to increase the riskiness of the assets, but they may lack the power to do so. Considering only ”powerful” shareholders, definitive conclusions were drawn but with constant ownership profile. In this paper I investigate whether there is a significant change in the type of shareholders in response to regulatory capital shocks and, if so, will the banking system be in the hands of more “desired” shareholders. I find that ownership profile responds to a regulatory shock, changing the risk appetite of the ruling power at the bank. I find more banks and the government in the ownership of undercapitalised banks and much less institutional shareholders and free float. I claim that these new shareholders may not the desired ones, given the objective of the regulatory change, as they are associated with a preference for more leverage. One possible explanation for this crowding-out effect is that regulators are trying to contain idiosyncratic risk (more linked to the riskiness of the assets) with a rule that contains systematic risk (capital adequacy). This has a distorting effect on ownership. Another insight can be drawn from the tests: supervisors should be aware of significant ownership movements that cause the crowding-out.
Resumo:
This thesis does not set out to focus on the dynamics relationship between Twitter and stock prices, but instead tries to understand if using relevant information extracted from tweets has the power to increase investors’ stock picking ability, and generate alpha in portfolio’s choice relative to a benchmark. Despite the short period analyzed, it gives promising results that the sentiment analysis performed by Social Market Analytics Inc. applied to an equity portfolio, is able to generate positive abnormal returns, statistically significant in and out of sample.
Resumo:
The purpose of the following study is to analyze the relevance of the principle of confidentiality concerning mediation on civil and commercial matters developed in Portugal. We will, essentially, try to determine just how pivotal is this principle and how it affects the effectiveness of that method of alternative dispute resolution. We believe it is fundamental to understand the true extent of this principle and its goals, emphasizing the protection given to those who decide to resort to mediation and its impact on this process. For this dissertation, we have based our analysis on the interpretation of the set rules assembled by Law nr 29/2013, April 19th, while combining it with data gathered from other laws and regulations that had also addressed mediation. Furthermore, given the fact that this subject has been regulated by Directive 2008/52/EC, we deem pertinent to include references to other European mediation regulations, namely from Germany, Spain and France. With this study, we have established that, even though the Portuguese mediation law is based on a European Directive, we have determined a more restrictive regulation for the principle of confidentiality. We have concluded that the rules regarding this principle try to preserve, above all, the trust and honesty established during the course of the mediation, while restricting the possibility of using the information disclosed during these sessions on other cases. Additionally, we believe confidentiality is such a distinctive and relevant feature that its legal framework leads us to deem it as a true obstacle to the parties’ private autonomy and their power to determine how the mediation should be carried out.
Resumo:
In the context of the activity developed by securities investment funds (hereinafter referred to “SIF”) the holders of investment units have a very tiny power to intervene. Aware of the risks that a decoupling between ownership and control may pose, the legislator has foreseen a number of impositions and limitations to the activity of the managing entities, namely to prevent or prohibit the performance of acts in situations of potential conflicts of interests. Accordingly, the purpose of the dissertation on – “Os diferentes níveis de regulação legal dos conflitos de interesses no âmbito da gestão de FIM” – is exactly to determine the field of application of the several levels of legal regulation of the conflicts of interests that arise within the scope of the management of SIF, both at the level of the new legal requirements governing collective investment undertakings, and at the level of the legal requirements governing the conflicts of interests foreseen in the Portuguese Securities Code, in order to clarify the articulation of these different levels of conflicts of interests regulations.
Resumo:
Dissertação apresentada para obtenção do Grau de Doutor em Ciências do Ambiente pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecn