QuEChERS method was evaluated for extraction of 16 PAHs from fish samples. For a selective measurement of the compounds, extracts were analysed by LC with fluorescence detection. The overall analytical procedure was validated by systematic recovery experiments at three levels and by using the standard reference material SRM 2977 (mussel tissue). The targeted contaminants, except naphthalene and acenaphthene, were successfully extracted from SRM 2977 with recoveries ranging from 63.5–110.0% with variation coefficients not exceeding 8%. The optimum QuEChERS conditions were the following: 5 g of homogenised fish sample, 10 mL of ACN, agitation performed by vortex during 3 min. Quantification limits ranging from 0.12– 1.90 ng/g wet weight (0.30–4.70 µg/L) were obtained. The optimized methodology was applied to assess the safety concerning PAHs contents of horse mackerel (Trachurus trachurus), chub mackerel (Scomber japonicus), sardine (Sardina pilchardus) and farmed seabass (Dicentrarchus labrax). Although benzo(a)pyrene, the marker used for evaluating the carcinogenic risk of PAHs in food, was not detected in the analysed samples (89 individuals corresponding to 27 homogenized samples), the overall mean concentration ranged from 2.52 l 1.20 ng/g in horse mackerel to 14.6 ± 2.8 ng/ g in farmed seabass. Significant differences were found between the mean PAHs concentrations of the four groups.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This technical report is to provide a reference guide to the implementation of the IEEE 802.15.4 protocol in nesC/TinyOS for the MICAz motes. The implementation is provided as a tool that can be used to implement, test and evaluate the current functionalities defined in the protocol standard as well as to enable the development of functionalities not yet implemented and new add-ons to the protocol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este estudo pretende medir a qualidade de vida dos indivíduos com perda auditiva (PA), definida pela perda média dos limiares aéreos tonais. Este estudo transversal quantitativo e descritivo foi conduzido entre Maio e Outubro de 2010 numa amostra de 328 indivíduos (47.0% do género masculino), com idade média ± desvio-padrão de 45.82 ± 12.93 anos, referenciados ao Gabinete de Audiologia do CHTS-UPA, EPE que foram avaliados e entrevistados. Recorreu-se à Versão Portuguesa 2 do Questionário de Estado de Saúde (SF-36v2) do CEIS-FE-UC, como instrumento para medir a qualidade de vida, complementado com um questionário de identificação e de dados sócio-demográficos e clínicos. RESULTADOS: Os indivíduos com perda auditiva que integraram a amostra do presente estudo revelaram piores percepções do Estado de Saúde do que as autopercepções dos elementos da amostra que constituiram os valores de referência, principalmente nas dimensões Saúde Geral da componente Física e nas dimensões Função Social e Saúde Mental da componente Mental da Saúde. CONCLUSÕES: a perda auditiva encontra-se negativamente associada a valores elevados de saúde, promovendo diferenças entre indivíduos com PA e indivíduos sem PA, nas dimensões do SF-36v2, Funcão Física e Social, Desempenho Físico e Emocional, Saúde Geral e Mental e Vitalidade. A avaliação da audição, a prevenção da perda auditiva e a reabilitação auditiva podem contribuir para uma melhoria do desempenho social e bemestar da população.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada ao Instituto Superior de Contabilidade e Administração do Porto para a obtenção do Grau de Mestre em Auditoria Orientada pelo Dr. José da Silva Fernandes

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada ao Instituto Superior de Contabilidade e Administração do Porto (ISCAP) para a obtenção do Grau de Mestre em Auditoria Docente orientador: Mestre Domingos da Silva Duarte

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Contabilidade e Finanças Orientador: Doutor, José Manuel Veiga Pereira

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A osteoporose é uma doença crónica e progressiva. O diagnóstico baseia-se na avaliação de densidade mineral óssea (DMO), por absorciometria bifotónica por RX (DXA) e no conceito operacional da Organização Mundial de Saúde (OMS) indicando que a doença acontece para valores de DMO inferiores a 2,5 desvios-padrão do valor médio máximo para mulheres jovens, saudáveis de etnia caucasóide. Existe variabilidade nos valores de pico de massa óssea entre diferentes populações. Este estudo pretende avaliar a prevalência de osteoporose quando utilizada a base de referência do equipamento e quando utilizada a base de dados para score-T construída a partir da amostra.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de Mestrado apresentado ao Instituto de Contabilidade e Administração do obtenção do grau de Mestre em Auditoria Auditoria, sob orientação de Adalmiro Álvaro Malheiro de Castro Andrade

Relevância:

20.00% 20.00%

Publicador:

Resumo:

GOAL: The manufacturing and distribution of strips of instant thin - layer chromatography with silica gel (ITLC - SG) (reference method) is currently discontinued so there is a need for an alternative method f or the determination of radiochemical purity (RCP) of 99m Tc - tetrofosmin. This study aims to compare five alternative methods proposed by the producer to determine the RCP of 99m Tc - tetrofosmin. METHODS: Nineteen vials of tetrofosmin were radiolabelled with 99m Tc and the percentages of the RCP were determined. Five different methods were compared with the standard RCP testing method (ITLC - SG, 2x20 cm): Whatman 3MM (1x10 cm) with acetone and dichloro - methane (method 1); Whatman 3MM (1x1 0 cm) with ethyl acetate (method 2); aluminum oxide - coated plastic thin - layer chromatography (TLC) plate (1x10 cm) and ethanol (method 3); Whatman 3MM (2x20 cm) with acetone and dichloro - methane (method 4); solid - phase extraction method C18 cartridge (meth od 5). RESULTS: The average values of RCP were 95,30% ± 1,28% (method 1), 93,95 ± 0,61% (method 2), 96,85% ± 0,93% (method 3), 92,94% ± 0,99% (method 4) and 96,25% ± 2,57% (method 5) (n=12 each), and 93,15% ± 1,13% for the standard method (n=19). There we re statistical significant differences in the values obtained for methods 1 (P=0,001), 3 (P=0,000) and 5 (P=0,004), and there were no statistical significant differences in the values obtained for methods 2 (P=0,113) and 4 (P=0,327). CONCLUSION: From the results obtained, methods 2 and 4 showed a higher correlation with the standard method. Unlike method 4, method 2 is less time - consuming than the reference method and can overcome the problems associated with the solvent toxicity. The remaining methods (1, 3 and 5) tended to overestimate RCP value compared to the standard method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Química. Ramo Tecnologias de Protecção Ambiental.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A presente dissertação tem como intuito aplicar o regime de Responsabilidade Ambiental no perímetro industrial da Monteiro, Ribas – Indústrias, S.A.. Para tal, averiguou-se que na ordem jurídica nacional, o regime de Responsabilidade Ambiental (RA) encontra-se consagrada na legislação nacional pelo Decreto-Lei nº 147/2008 de 29 de Julho (Diploma RA),e respetivas alterações, aplicando-se a danos ambientais ou ameaças iminentes de danos ambientais causados aos recursos naturais nomeadamente “espécies e habitats naturais protegidos”, “água” e “solo”. Também se verificou que este regime introduz obrigações específicas para os operadores abrangidos, designadamente é da responsabilidade do operador aplicar as medidas de prevenção e reparação dos danos, devendo ser reportados os acontecimentos à autoridade competente, Agência Portuguesa do Ambiente. Para cumprimento do requisito da garantia financeira e sendo a Monteiro, Ribas – Indústrias, S.A. enumerada no Anexo III do Decreto-Lei nº 147/2008 de 29 de Julho, optou-se pela constituição de um fundo próprio no valor de 50.000,00€. Com recurso à metodologia proposta pela Norma Espanhola UNE 150008:2008 - Análise e avaliação do Risco Ambiental, procedeu-se à formulação de vários cenários e quantificação de riscos para a Monteiro, Ribas – Indústrias, S.A. tendo-se apurado que os riscos estavam avaliados como baixo ou moderado. Por fim, conclui-se que em Portugal, embora exista um Decreto-Lei sobre Responsabilidade Ambiental, este tema ainda não está suficientemente desenvolvido pois não permite proceder a análise e avaliação do risco ambiental, tendo sido tomado assim como referência a metodologia aplicada na Norma Espanhola UNE 150008:2008.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aiming the establishment of simple and accurate readings of citric acid (CA) in complex samples, citrate (CIT) selective electrodes with tubular configuration and polymeric membranes plus a quaternary ammonium ion exchanger were constructed. Several selective membranes were prepared for this purpose, having distinct mediator solvents (with quite different polarities) and, in some cases, p-tert-octylphenol (TOP) as additive. The latter was used regarding a possible increase in selectivity. The general working characteristics of all prepared electrodes were evaluated in a low dispersion flow injection analysis (FIA) manifold by injecting 500µl of citrate standard solutions into an ionic strength (IS) adjuster carrier (10−2 mol l−1) flowing at 3ml min−1. Good potentiometric response, with an average slope and a repeatability of 61.9mV per decade and ±0.8%, respectively, resulted from selective membranes comprising additive and bis(2-ethylhexyl)sebacate (bEHS) as mediator solvent. The same membranes conducted as well to the best selectivity characteristics, assessed by the separated solutions method and for several chemical species, such as chloride, nitrate, ascorbate, glucose, fructose and sucrose. Pharmaceutical preparations, soft drinks and beers were analyzed under conditions that enabled simultaneous pH and ionic strength adjustment (pH = 3.2; ionic strength = 10−2 mol l−1), and the attained results agreed well with the used reference method (relative error < 4%). The above experimental conditions promoted a significant increase in sensitivity of the potentiometric response, with a supra-Nernstian slope of 80.2mV per decade, and allowed the analysis of about 90 samples per hour, with a relative standard deviation <1.0%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose the use of the European Geostationary Navigation Overlay Service (EGNOS) data - real time on line data provided by SISNeT - to develop Virtual Reference Stations and, thus, increase the quality of the Position, Velocity an Time (PVT) solution of receivers unable to interface directly with EGNOS. A Virtual Reference Station (VRS) is a concept where the existence of a differential reference station located near a mobile rover is simulated by software in order to increase the accuracy of the PVT solution of the mobile GNSS receiver.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The international Electrotechnical Commission (IEC) 61499 architecture incorporated several function block with which distributed control application may be developed, and how these are interpreted and executed. However, due the distributed nature of the control applications, many issues also need to be taken into account. Most of these are due to the new error model and failure modes of the distributed hardware on which the distributed application is executed and also due the incomplete standards definition of the execution models. IEC 61499 frameworks does not clarify how to handle with replication of software and hardware components. In this paper we propose a replication model for IEC 61499 applications and which mechanisms and protocols may be used for their support.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The structural integrity of multi-component structures is usually determined by the strength and durability of their unions. Adhesive bonding is often chosen over welding, riveting and bolting, due to the reduction of stress concentrations, reduced weight penalty and easy manufacturing, amongst other issues. In the past decades, the Finite Element Method (FEM) has been used for the simulation and strength prediction of bonded structures, by strength of materials or fracture mechanics-based criteria. Cohesive-zone models (CZMs) have already proved to be an effective tool in modelling damage growth, surpassing a few limitations of the aforementioned techniques. Despite this fact, they still suffer from the restriction of damage growth only at predefined growth paths. The eXtended Finite Element Method (XFEM) is a recent improvement of the FEM, developed to allow the growth of discontinuities within bulk solids along an arbitrary path, by enriching degrees of freedom with special displacement functions, thus overcoming the main restriction of CZMs. These two techniques were tested to simulate adhesively bonded single- and double-lap joints. The comparative evaluation of the two methods showed their capabilities and/or limitations for this specific purpose.