14 resultados para tailored

em Instituto Politécnico do Porto, Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work introduces two major changes to the conventional protocol for designing plastic antibodies: (i) the imprinted sites were created with charged monomers while the surrounding environment was tailored using neutral material; and (ii) the protein was removed from its imprinted site by means of a protease, aiming at preserving the polymeric network of the plastic antibody. To our knowledge, these approaches were never presented before and the resulting material was named here as smart plastic antibody material (SPAM). As proof of concept, SPAM was tailored on top of disposable gold-screen printed electrodes (Au-SPE), following a bottom-up approach, for targeting myoglobin (Myo) in a point-of-care context. The existence of imprinted sites was checked by comparing a SPAM modified surface to a negative control, consisting of similar material where the template was omitted from the procedure and called non-imprinted materials (NIMs). All stages of the creation of the SPAM and NIM on the Au layer were followed by both electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). AFM imaging was also performed to characterize the topography of the surface. There are two major reasons supporting the fact that plastic antibodies were effectively designed by the above approach: (i) they were visualized for the first time by AFM, being present only in the SPAM network; and (ii) only the SPAM material was able to rebind to the target protein and produce a linear electrical response against EIS and square wave voltammetry (SWV) assays, with NIMs showing a similar-to-random behavior. The SPAM/Au-SPE devices displayed linear responses to Myo in EIS and SWV assays down to 3.5 μg/mL and 0.58 μg/mL, respectively, with detection limits of 1.5 and 0.28 μg/mL. SPAM materials also showed negligible interference from troponin T (TnT), bovine serum albumin (BSA) and urea under SWV assays, showing promising results for point-of-care applications when applied to spiked biological fluids.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new man-tailored biomimetic sensor for Chlorpromazine host-guest interactions and potentiometric transduction is presented. The artificial host was imprinted within methacrylic acid, 2-vinyl pyridine and 2-acrylamido-2-methyl-1-propanesulfonic acid based polymers. Molecularly imprinted particles were dispersed in 2-nitrophenyloctyl ether and entrapped in a poly(vinyl chloride) matrix. Slopes and detection limits ranged 51–67 mV/decade and 0.46–3.9 μg/mL, respectively, in steady state conditions. Sensors were independent fromthe pHof test solutionswithin 2.0–5.5.Good selectivitywas observed towards oxytetracycline, doxytetracycline, ciprofloxacin, enrofloxacin, nalidixic acid, sulfadiazine, trimethoprim, glycine, hydroxylamine, cysteine and creatinine. Analytical features in flowing media were evaluated on a double-channel manifold, with a carrier solution of 5.0×10−2 mol/L phosphate buffer. Near-Nernstian response was observed over the concentration range 1.0×10−4 to 1.0×10−2 mol/L. Average slopes were about 48 mV/decade. The sensors were successfully applied to field monitoring of CPZ in fish samples, offering the advantages of simplicity, accuracy, automation feasibility and applicability to complex samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The tribological response of multilayer micro/nanocrystalline diamond coatings grown by the hot filament CVD technique is investigated. These multigrade systems were tailored to comprise a starting microcrystalline diamond (MCD) layer with high adhesion to a silicon nitride (Si3N4) ceramic substrate, and a top nanocrystalline diamond (NCD) layer with reduced surface roughness. Tribological tests were carried out with a reciprocating sliding configuration without lubrication. Such composite coatings exhibit a superior critical load before delamination (130–200 N), when compared to the mono- (60–100 N) and bilayer coatings (110 N), considering ∼10 µm thick films. Regarding the friction behaviour, a short-lived initial high friction coefficient was followed by low friction regimes (friction coefficients between 0.02 and 0.09) as a result of the polished surfaces tailored by the tribological solicitation. Very mild to mild wear regimes (wear coefficient values between 4.1×10−8 and 7.7×10−7 mm3 N−1 m−1) governed the wear performance of the self-mated multilayer coatings when subjected to high-load short-term tests (60–200 N; 2 h; 86 m) and medium-load endurance tests (60 N; 16 h; 691 m).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Compreender a funcionalidade de uma criança é um desafio persistente em contextos de saúde e educação. Na tentativa de superar esse desafio, em 2007, a Organização Mundial de Saúde desenvolveu a Classificação Internacional de Funcionalidade, Incapacidade e Saúde para Crianças e Jovens (CIF-CJ) como o primeiro sistema de classificação universal para documentar a saúde e funcionalidade da criança. Apesar de a CIF-CJ não ser um instrumento de avaliação e intervenção, tem, no entanto, a capacidade de servir de enquadramento para o desenvolvimento de ferramentas adaptadas às necessidades dos seus utilizadores. Considerando que no contexto escolar, a escrita manual encontra-se entre as atividades mais requeridas para a participação plena de uma criança, parece ser pertinente a definição de um conjunto de códigos destinados a caracterizar o perfil de funcionalidade de uma criança, no que se refere à escrita manual. O objetivo deste estudo foi, pois, o desenvolvimento de um conjunto preliminar de códigos baseado na CIF-CJ que possa vir a constituir um code set para a escrita manual. Dada a complexidade do tema e atendendo a que se pretende alcançar consenso entre os especialistas sobre quais as categorias da CIF-CJ que devem ser consideradas, optou-se pela utilização da técnica de Delphi. A escolha da metodologia seguiu a orientação dos procedimentos adotados pelo projeto Core Set CIF. De dezoito profissionais contactados, obtiveram-se respostas de sete terapeutas ocupacionais com experiência em pediatria, que participaram em todas as rondas. No total, três rondas de questionários foram realizadas para atingir um consenso, com um nível de concordância, previamente definido, de 70%. Deste estudo resultou um conjunto preliminar de códigos com 54 categorias da CIF-CJ (16 categorias de segundo nível, 14 categorias de terceiro nível e uma categoria de quarto nível), das quais 31 são categorias das funções do corpo, uma categoria das estruturas do corpo, 12 categorias de atividades e participação e 10 categorias de fatores ambientais. Este estudo é um primeiro passo para o desenvolvimento de um code set para a escrita manual baseado na CIF-CJ , sendo claramente necessário a realização de mais pesquisas no contexto do desenvolvimento e da validação deste code set.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hand-off (or hand-over), the process where mobile nodes select the best access point available to transfer data, has been well studied in wireless networks. The performance of a hand-off process depends on the specific characteristics of the wireless links. In the case of low-power wireless networks, hand-off decisions must be carefully taken by considering the unique properties of inexpensive low-power radios. This paper addresses the design, implementation and evaluation of smart-HOP, a hand-off mechanism tailored for low-power wireless networks. This work has three main contributions. First, it formulates the hard hand-off process for low-power networks (such as typical wireless sensor networks - WSNs) with a probabilistic model, to investigate the impact of the most relevant channel parameters through an analytical approach. Second, it confirms the probabilistic model through simulation and further elaborates on the impact of several hand-off parameters. Third, it fine-tunes the most relevant hand-off parameters via an extended set of experiments, in a realistic experimental scenario. The evaluation shows that smart-HOP performs well in the transitional region while achieving more than 98 percent relative delivery ratio and hand-off delays in the order of a few tens of a milliseconds.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Engenharia Mecânica – Gestão Industrial

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de Mestrado Apresentada ao Instituto de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Auditoria, sob orientação do Mestre Carlos Mendes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work shows that the synthesis of protein plastic antibodies tailored with selected charged monomersaround the binding site enhances protein binding. These charged receptor sites are placed over a neutralpolymeric matrix, thus inducing a suitable orientation the protein reception to its site. This is confirmed bypreparing control materials with neutral monomers and also with non-imprinted template. This concepthas been applied here to Prostate Specific Antigen (PSA), the protein of choice for screening prostate can-cer throughout the population, with serum levels >10 ng/mL pointing out a high probability of associatedcancer.Protein Imprinted Materials with charged binding sites (C/PIM) have been produced by surfaceimprinting over graphene layers to which the protein was first covalently attached. Vinylben-zyl(trimethylammonium chloride) and vinyl benzoate were introduced as charged monomers labellingthe binding site and were allowed to self-organize around the protein. The subsequent polymerizationwas made by radical polymerization of vinylbenzene. Neutral PIM (N/PIM) prepared without orientedcharges and non imprinted materials (NIM) obtained without template were used as controls.These materials were used to develop simple and inexpensive potentiometric sensor for PSA. Theywere included as ionophores in plasticized PVC membranes, and tested over electrodes of solid or liq-uid conductive contacts, made of conductive carbon over a syringe or of inner reference solution overmicropipette tips. The electrodes with charged monomers showed a more stable and sensitive response,with an average slope of -44.2 mV/decade and a detection limit of 5.8 × 10−11mol/L (2 ng/mL). The cor-responding non-imprinted sensors showed lower sensitivity, with average slopes of -24.8 mV/decade.The best sensors were successfully applied to the analysis of serum, with recoveries ranging from 96.9to 106.1% and relative errors of 6.8%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Carnitine (CRT) is a biological metabolite found in urine that contributes in assessingseveral disease conditions, including cancer. Novel quick screening procedures for CRT are therefore fundamental. This work proposes a novel potentiometric device where molecularly imprinted polymers (MIPs) were used as ionophores. The host-tailored sites were imprinted on a polymeric network assembled by radical polymerization of methacrylic acid (MAA) and trimethylpropane trimethacrylate (TRIM). Non-imprinted polymers (NIPs) were produced as control by removing the template from the reaction media. The selective membrane was prepared by dispersing MIP or NIP particles in plasticizer and poly(vinyl chloride), PVC, and casting this mixture over a solid contact support made of graphite. The composition of the selective membrane was investigated with regard to kind/amount of sensory material (MIP or NIP), and the need for a lipophilic additive. Overall, MIP sensors with additive exhibited the best performance, with near-Nernstian response down to ~ 1 × 10− 4 mol L− 1, at pH 5, and a detection limitof ~ 8 × 10− 5 mol L− 1. Suitable selectivity was found for all membranes, assessed by the matched potential method against some of the most common species in urine (urea, sodium, creatinine, sulfate, fructose and hemoglobin). CRT selective membranes including MIP materials were applied successfully to the potentiometric determination of CRT in urine samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

IEEE International Conference on Cyber Physical Systems, Networks and Applications (CPSNA'15), Hong Kong, China.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new man-tailored biomimetic sensor for Chlorpromazine host-guest interactions and potentiometric transduction is presented. The artificial host was imprinted within methacrylic acid, 2-vinyl pyridine and 2-acrylamido-2-methyl-1-propanesulfonic acid based polymers. Molecularly imprinted particles were dispersed in 2-nitrophenyloctyl ether and entrapped in a poly(vinyl chloride) matrix. Slopes and detection limits ranged 51–67 mV/decade and 0.46–3.9 μg/mL, respectively, in steady state conditions. Sensors were independent from the pH of test solutions within 2.0–5.5. Good selectivity was observed towards oxytetracycline, doxytetracycline, ciprofloxacin, enrofloxacin, nalidixic acid, sulfadiazine, trimethoprim, glycine, hydroxylamine, cysteine and creatinine. Analytical features in flowing media were evaluated on a double-channel manifold, with a carrier solution of 5.0 × 10−2 mol/L phosphate buffer. Near-Nernstian response was observed over the concentration range 1.0 × 10−4 to 1.0 × 10−2 mol/L. Average slopes were about 48 mV/decade. The sensors were successfully applied to field monitoring of CPZ in fish samples, offering the advantages of simplicity, accuracy, automation feasibility and applicability to complex samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Na sociedade atual, a preocupação com o ambiente, por um lado, e com o conforto e a segurança, por outro, faz com que a sustentabilidade energética se assuma como uma forma de intervenção adequada às exigências de qualidade de vida e à eficiência no âmbito da economia. Nesta conformidade, é incontornável a mais-valia do Smart Panel, um quadro elétrico inteligente criado com vista à consecução daqueles desideratos, o que motivou o tema do presente trabalho. Assim, pretende-se demonstrar as potencialidades do Smart Panel, um novo conceito de quadro elétrico que visa a otimização da sua funcionalidade na gestão dinâmica e pragmática das instalações elétricas, nomeadamente no que respeita ao controlo, monitorização e atuação sobre os dispositivos, quer in loco quer, sobretudo, à distância. Para a consecução deste objetivo, concorrem outros que o potenciam, designadamente a compreensão do funcionamento do quadro elétrico (QE) tradicional, a comparação deste com o Smart Panel e a demonstração das vantagens da utilização desta nova tecnologia. A grande finalidade do trabalho desenvolvido é, por um lado, colocar a formação académica ao serviço de um bom desempenho profissional futuro, por outro ir ao encontro da tendência tecnológica inerente às necessidades que o homem, hoje, tem de controlar. Deste modo, num primeiro momento, é feita uma abordagem geral ao quadro eléctrico tradicional a fim de ser compreendido o seu funcionamento, aplicações e potencialidades. Para tanto, a explanação inclui a apresentação de conceitos teóricos subjacentes à conceção, produção e montagem do QE. São explicitados os diversos componentes que o integram e funções que desempenham, bem como as interações que estabelecem entre si e os normativos a que devem obedecer, para conformidade. Houve a preocupação de incluir imagens coadjuvantes das explicações, descrições e procedimentos técnicos. No terceiro capítulo é abordada a tecnologia Smart Panel, introduzindo o conceito e objetivos que lhe subjazem. Explicita-se o modo de funcionamento deste sistema que agrupa proteção, supervisão, controlo, armazenamento e manutenção preventiva, e demonstra-se de que forma a capacidade de leitura de dados, de comunicação e de comando do quadro elétrico à distância se afigura uma revolução tecnológica facilitadora do cumprimento das necessidades de segurança, conforto e economia da vida moderna. Os capítulos quarto, quinto e sexto versam uma componente prática do trabalho. No capítulo quarto é explanado um suporte formativo e posterior demonstração do kit de ensaio, que servirá de apoio à apresentação da tecnologia Smart Panel aos clientes. Além deste suporte de formação, no quinto capítulo é elaborada uma lista de procedimentos de verificação a serem executados aos componentes de comunicação que integram o Smart Panel, para fornecimento ao quadrista. Por fim, no sexto capítulo incluem-se dois casos de estudo: o estudo A centra-se na aplicação da tecnologia Smart Panel ao projeto de um QE tradicional, que implica fazer o levantamento de toda a aparelhagem existente e, de seguida, proceder à transposição para a tecnologia Smart Panel por forma a cumprir os requisitos estabelecidos pelo cliente. O estudo de caso B consiste na elaboração de um projeto de um quadro eléctrico com a tecnologia Smart Panel em função de determinados requisitos e necessidades do cliente, por forma a garantir as funções desejadas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O presente relatório tem como intuito refletir sobre o desenvolvimento pessoal e profissional da mestranda, a sua experiência e os conhecimentos adquiridos em resultado da prática pedagógica supervisionada desenvolvida ao nível da Educação Pré-Escolar e do 1.º Ciclo do Ensino Básico ao longo deste mestrado. Ao longo da prática, a ação da mestranda foi orientada pela metodologia de investigação-ação, constituída por várias etapas cíclicas e articuladas (observação, planificação, ação, reflexão e avaliação) numa perspetiva socio construtivista. Esta estratégia possibilitou a planificação de atividades adequadas às caraterísticas específicas de cada grupo. Para isso foi indispensável adotar uma atitude profissional indagadora, de caráter investigativo e crítico-reflexivo, que permitiu agir intencionalmente em cada situação, procurando atender às necessidades e interesses de cada criança. A mestranda desenvolveu a sua forma pessoal de pensar e agir no decorrer da sua prática baseando-se em quadros teóricos e concetuais, visando uma diferenciação educativa e uma colaboração profissional e reflexiva. Em suma, os estágios desenvolvidos nos dois níveis educativos promoveram a edificação de uma postura profissional reflexiva e investigativa que favoreceu a tomada de decisões em contexto de prática. Neste contexto, foram reafirmadas competências profissionais e pessoais e abriu-se caminho para uma formação ao longo da vida, essencial para um docente generalista.