Novel Prostate Specific Antigen plastic antibody designed withcharged binding sites for an improved protein binding and itsapplication in a biosensor of potentiometric transduction


Autoria(s): Rebelo, Tânia S. C. R.; Santos, C.; Costa-Rodrigues, João; Fernandes, M.H.; Noronha, João P. C.; Sales, M. Goreti F.
Data(s)

15/10/2015

15/10/2015

2014

Resumo

This work shows that the synthesis of protein plastic antibodies tailored with selected charged monomersaround the binding site enhances protein binding. These charged receptor sites are placed over a neutralpolymeric matrix, thus inducing a suitable orientation the protein reception to its site. This is confirmed bypreparing control materials with neutral monomers and also with non-imprinted template. This concepthas been applied here to Prostate Specific Antigen (PSA), the protein of choice for screening prostate can-cer throughout the population, with serum levels >10 ng/mL pointing out a high probability of associatedcancer.Protein Imprinted Materials with charged binding sites (C/PIM) have been produced by surfaceimprinting over graphene layers to which the protein was first covalently attached. Vinylben-zyl(trimethylammonium chloride) and vinyl benzoate were introduced as charged monomers labellingthe binding site and were allowed to self-organize around the protein. The subsequent polymerizationwas made by radical polymerization of vinylbenzene. Neutral PIM (N/PIM) prepared without orientedcharges and non imprinted materials (NIM) obtained without template were used as controls.These materials were used to develop simple and inexpensive potentiometric sensor for PSA. Theywere included as ionophores in plasticized PVC membranes, and tested over electrodes of solid or liq-uid conductive contacts, made of conductive carbon over a syringe or of inner reference solution overmicropipette tips. The electrodes with charged monomers showed a more stable and sensitive response,with an average slope of -44.2 mV/decade and a detection limit of 5.8 × 10−11mol/L (2 ng/mL). The cor-responding non-imprinted sensors showed lower sensitivity, with average slopes of -24.8 mV/decade.The best sensors were successfully applied to the analysis of serum, with recoveries ranging from 96.9to 106.1% and relative errors of 6.8%.

Identificador

http://hdl.handle.net/10400.22/6697

10.1016/j.electacta.2014.03.108

Idioma(s)

eng

Publicador

Elsevier

Relação

http://www.sciencedirect.com/science/article/pii/S0013468614006215

Direitos

openAccess

Palavras-Chave #Prostate Specific Antigen #Potentiometry #Graphene layers #Ion selective sensors #Molecularly-imprinted polymers #Serum
Tipo