43 resultados para Total Quality Control
em Instituto Politécnico do Porto, Portugal
Resumo:
Introduction: Paper and thin layer chromatography methods are frequently used in Classic Nuclear Medicine for the determination of radiochemical purity (RCP) on radiopharmaceutical preparations. An aliquot of the radiopharmaceutical to be tested is spotted at the origin of a chromatographic strip (stationary phase), which in turn is placed in a chromatographic chamber in order to separate and quantify radiochemical species present in the radiopharmaceutical preparation. There are several methods for the RCP measurement, based on the use of equipment as dose calibrators, well scintillation counters, radiochromatografic scanners and gamma cameras. The purpose of this study was to compare these quantification methods for the determination of RCP. Material and Methods: 99mTc-Tetrofosmin and 99mTc-HDP are the radiopharmaceuticals chosen to serve as the basis for this study. For the determination of RCP of 99mTc-Tetrofosmin we used ITLC-SG (2.5 x 10 cm) and 2-butanone (99mTc-tetrofosmin Rf = 0.55, 99mTcO4- Rf = 1.0, other labeled impurities 99mTc-RH RF = 0.0). For the determination of RCP of 99mTc-HDP, Whatman 31ET and acetone was used (99mTc-HDP Rf = 0.0, 99mTcO4- Rf = 1.0, other labeled impurities RF = 0.0). After the development of the solvent front, the strips were allowed to dry and then imaged on the gamma camera (256x256 matrix; zoom 2; LEHR parallel-hole collimator; 5-minute image) and on the radiochromatogram scanner. Then, strips were cut in Rf 0.8 in the case of 99mTc-tetrofosmin and Rf 0.5 in the case of 99mTc-HDP. The resultant pieces were smashed in an assay tube (to minimize the effect of counting geometry) and counted in the dose calibrator and in the well scintillation counter (during 1 minute). The RCP was calculated using the formula: % 99mTc-Complex = [(99mTc-Complex) / (Total amount of 99mTc-labeled species)] x 100. Statistical analysis was done using the test of hypotheses for the difference between means in independent samples. Results:The gamma camera based method demonstrated higher operator-dependency (especially concerning the drawing of the ROIs) and the measures obtained using the dose calibrator are very sensitive to the amount of activity spotted in the chromatographic strip, so the use of a minimum of 3.7 MBq activity is essential to minimize quantification errors. Radiochromatographic scanner and well scintillation counter showed concordant results and demonstrated the higher level of precision. Conclusions: Radiochromatographic scanners and well scintillation counters based methods demonstrate to be the most accurate and less operator-dependant methods.
Resumo:
Electroanalytical methods based on square-wave adsorptive-stripping voltammetry (SWAdSV) and flow-injection analysis with square-wave adsorptive-stripping voltammetric detection (FIA-SWAdSV) were developed for the determination of fluoxetine (FXT). The methods were based on the reduction of FXT at a mercury drop electrode at -1.2 V versus Ag/AgCl, in a phosphate buffer of pH 12.0, and on the possibility of accumulating the compound at the electrode surface. The SWAdSV method was successfully applied in the quantification of FXT in pharmaceutical products, human serum samples, and in drug dissolution studies. Because the presence of dissolved oxygen did not interfere significantly with the analysis, it was possible to quantify FXT in several pharmaceutical products using FIA-SWAdSV. This method enables analysis of up to 120 samples per hour at reduced costs.
Resumo:
The oxidative behaviour of fluoxetine was studied at a glassy carbon electrode in various buffer systems and at different pH using cyclic, differential pulse and square wave voltammetry. A new square wave voltammetric method suitable for the quality control of fluoxetine in commercial formulations has been developed using a borate pH 9 buffer solution as supporting electrolyte. Under optimized conditions, a linear response was obtained in the range 10 to 16 μM with a detection limit of 1.0 μM. Validation parameters such as sensitivity, precision and accuracy were evaluated. The proposed method was successfully applied to the determination of fluoxetine in pharmaceutical formulations. The results were statistically compared with those obtained by the reference high-performance liquid chromatographic method. No significant differences were found between the methods.
Resumo:
Food lipid major components are usually analyzed by individual methodologies using diverse extractive procedures for each class. A simple and fast extractive procedure was devised for the sequential analysis of vitamin E, cholesterol, fatty acids, and total fat estimation in seafood, reducing analyses time and organic solvent consumption. Several liquid/liquid-based extractive methodologies using chlorinated and non-chlorinated organic solvents were tested. The extract obtained is used for vitamin E quantification (normal-phase HPLC with fluorescence detection), total cholesterol (normal-phase HPLC with UV detection), fatty acid profile, and total fat estimation (GC-FID), all accomplished in <40 min. The final methodology presents an adequate linearity range and sensitivity for tocopherol and cholesterol, with intra- and inter-day precisions (RSD) from 3 to 11 % for all the components. The developed methodology was applied to diverse seafood samples with positive outcomes, making it a very attractive technique for routine analyses in standard equipped laboratories in the food quality control field.
Resumo:
Trabalho de Projeto apresentado ao Instituto Superior de Contabilidade e Administração do Porto para obtenção do grau de Mestre em Auditoria Orientado por: Doutora Alcina Augusta de Sena Portugal Dias
Resumo:
O bacalhau (Gadus morhua) faz parte da dieta alimentar dos portugueses há vários séculos, sendo atualmente, um dos maiores consumidores deste peixe a nível mundial. Após o processo de salga, esta espécie possui características únicas como a consistência, cheiro, paladar e cor amarela. É precisamente devido à coloração do peixe que alguns produtores da Islândia, Noruega e Dinamarca requisitaram às autoridades da União Europeia (UE) a aprovação da utilização de polifosfatos no processo de salga húmida do bacalhau. Os polifosfatos são aditivos alimentares bastante usados no processamento do pescado pois previnem a oxidação dos lípidos e proteínas do músculo do bacalhau, evitando assim a indesejada mudança de cor do peixe. Apesar dos esforços da Associação dos Industriais do Bacalhau (AIB) e do governo português para a rejeição da proposta nórdica, tal não se verificou. Deste modo, no início do próximo ano já será possível a venda na UE de bacalhau com fosfatos. A quantificação do teor de fosfatos no bacalhau é geralmente efetuada por Espetrofotometria de absorção molecular no ultravioleta-visível (UV-Visível). Esta quantificação é baseada no método de determinação do fósforo total, através da hidrólise dos fosfatos a ortofosfatos com posterior medição da cor amarela, gerada pela reação destes com uma solução de molibdato-vanadato. O objetivo desta dissertação foi a validação de um método de análise para a quantificação dos polifosfatos no bacalhau. O método validado foi o descrito na norma NP 4495 para produtos de pesca e aquicultura. O desenvolvimento deste trabalho foi realizado em laboratório acreditado para águas e produtos alimentares (Equilibrium - Laboratório de Controlo de Qualidade e de Processos Lda, L0312). Foi ainda determinada a influência do teor de cloreto de sódio na quantificação dos polifosfatos e o teor de humidade, uma vez que este pode afetar o produto durante a sua comercialização. No processo de validação do método foram estudados diversos parâmetros, tais como a seletividade, linearidade, sensibilidade, limite de quantificação e precisão. Pela análise dos resultados obtidos conclui-se que o método para determinação de fosfatos no bacalhau se encontra validado, uma vez que satisfaz todas as especificações determinadas para cada parâmetro de validação avaliado.
Resumo:
A par das patologias oncológicas, as doenças do foro cardíaco, em particular a doença arterial coronária, são uma das principais causas de morte nos países industrializados, devido sobretudo, à grande incidência de enfartes do miocárdio. Uma das formas de diagnóstico e avaliação desta condição passa pela obtenção de imagens de perfusão miocárdica com radionuclídeos, realizada por Tomografia por Emissão de Positrões (PET). As soluções injectáveis de [15O]-H2O, [82Rb] e [13N]-NH3 são as mais utilizadas neste tipo de exame clínico. No Instituto de Ciências Nucleares Aplicadas à Saúde (ICNAS), a existência de um ciclotrão tem permitido a produção de uma variedade de radiofármacos, com aplicações em neurologia, oncologia e cardiologia. Recentemente, surgiu a oportunidade de iniciar exames clínicos com [13N]-NH3 para avaliação da perfusão miocárdica. É neste âmbito que surge a oportunidade do presente trabalho, pois antes da sua utilização clínica é necessário realizar a optimização da produção e a validação de todo o processo segundo as normas de Boas Práticas Radiofarmacêuticas. Após uma fase de optimização do processo, procedeu-se à avaliação dos parâmetros físico-químicos e biológicos da preparação de [13N]-NH3, de acordo com as indicações da Farmacopeia Europeia (Ph. Eur.) 8.2. De acordo com as normas farmacêuticas, foram realizados 3 lotes de produção consecutivos para validação da produção de [13N]-NH3. Os resultados mostraram um produto final límpido e ausente de cor, com valores de pH dentro do limite especificado, isto é, entre 4,5 e 8,5. A pureza química das amostras foi verificada, uma vez que relativamente ao teste colorimétrico, a tonalidade da cor da solução de [13N]-NH3 não era mais intensa que a solução de referência. As preparações foram identificadas como sendo [13N]-NH3, através dos resultados obtidos por cromatografia iónica, espectrometria de radiação gama e tempo de semi-vida. Por examinação do cromatograma obtido com a solução a ser testada, observou-se que o pico principal possuia um tempo de retenção aproximadamente igual ao pico do cromatograma obtido para a solução de referência. Além disso, o espectro de radiação gama mostrou um pico de energia 0,511 MeV e um outro adicional de 1,022 MeV para os fotões gama, característico de radionuclídeos emissores de positrões. O tempo de semi-vida manteve-se dentro do intervalo indicado, entre 9 e 11 minutos. Verificou-se, igualmente, a pureza radioquímica das amostras, correspondendo um mínimo de 99% da radioactividade total ao [13N], bem como a pureza radionuclídica, observando-se uma percentagem de impurezas inferiores a 1%, 2h após o fim da síntese. Os testes realizados para verificação da esterilidade e determinação da presença de endotoxinas bacterianas nas preparações de [13N]-NH3 apresentaram-se negativos.Os resultados obtidos contribuem, assim, para a validação do método para a produção de [13N]-NH3, uma vez que cumprem os requisitos especificados nas normas europeias, indicando a obtenção de um produto seguro e com a qualidade necessária para ser administrado em pacientes para avaliação da perfusão cardíaca por PET.
Resumo:
A revision of several paths for the Quality journey is presented: from Quality Gurus and Total Quality Management (TQM) models to the ISO 9000 International Standards Series. Since ISO 9001:2008 is now in the revision process to the expected ISO 9001:2015 version, an analysis is made of he proposed changes and the underlying reasons and the impacts foreseen on the more than 1.3 Million certified organizations. This revision should be a step towards TQM and reflect the changes of an increasingly complex, demanding and dynamic environment, while assuring that complying organizations are able to provide conformity products and services that satisfy their customers. Major benefits are expected such as less emphasis on documentation and new/reinforced approaches: consideration of Organizational Context and (relevant) Stakeholders, Risk Based thinking and Knowledge Management.
Resumo:
The discussion of possible scenarios for the future of Quality is on the priority list of major Quality Practitioners Societies. EOQ – European Organization for Quality (EOQ, 2014) main team for its 58th EOQ-Congress held June 2014 in Göteborg was “Managing Challenges in Quality Leadership” and ASQ - American Society for Quality (ASQ, 2015) appointed “the Future of Quality” for Quality Progress Magazine November 2015 issue. In addition, the ISO 9001:2008 revision process carried by ISO/TC 176 aims to assure that ISO 9001:2015 International Standard remains stable for the next 10 years (ISO, 2014) contributing to an increased discussion on the future of quality. The purpose of this research is to review available Quality Management approaches and outline, adding an academic perspective, expected developments for Quality within the 21st Century. This paper follows a qualitative approach, although data from international organizations is used. A literature review has been undertaken on quality management past and potential future trends. Based on these findings a model is proposed for organization quality management development and propositions for the future of quality management are advanced. Firstly, a state of the art of existing Quality Management approaches is presented, for example, like Total Quality Management (TQM) and Quality Gurus, ISO 9000 International Standards Series (with an outline of the expected changes for ISO 9001:2015), Six Sigma and Business Excellence Models.Secondly, building on theoretical and managerial approaches, a two dimensional matrix – Quality Engineering (QE - technical aspects of quality) and Quality Management (QM: soft aspects of quality) - is presented, outlining five proposed characterizations of Quality maturity levels and giving insights for applications and future developments. Literature review highlights that QM and QE may be addressing similar quality issues but their approaches are different in terms of scope breadth and intensity and they ought to complement and reciprocally reinforce one another. The challenges organizations face within the 21st century have stronger uncertainty, complexity, and differentiation. Two main propositions are advanced as relevant for 21st Century Quality: - QM importance for the sustainable success of organizations will increase and they should be aware of the larger ecosystem to be managed for improvement, possibly leading to the emergence of a new Quality paradigm, The Civilizacional Excellence paradigm. - QE should get more attention from QM and the Quality professionals will have to: a) Master and apply in wider contexts and in additional depth the Quality Tools (basic, intermediate and advanced); b) Have the soft skills needed for its success; c) Be results oriented and better understand and demonstrate the relationships between approaches and results These propositions challenge both scholars and practitioners for a sustained and supported discussion on the future of Quality. “All things are ready, if our mind be so.” (Shakespeare, Henry V, circa 1599).
Resumo:
O presente Relatório de Estágio teve como objectivo analisar e discutir as competências adquiridas e desenvolvidas, durante o estágio, no controlo da qualidade microbiológica na indústria farmacêutica O estágio, foi realizado no Laboratório de Microbiologia dos Laboratórios Atral, Grupo AtralCipan, localizado na Vala do Carregado, Castanheira do Ribatejo. Este teve a duração de aproximadamente dez meses e meio, com data de início a 21 de Setembro de 2011 e final de 10 de Agosto de 2012. Numa fase inicial, foram adquiridas as aptidões necessárias para a aplicação das metodologias realizadas no laboratório de microbiologia com o estudo das normas, procedimento e legislação aplicada, com foco na importância das farmacopeias na indústria farmacêutica e formação para a realização de ensaios em Áreas de Processamento Asséptico, conhecendo e compreendendo os procedimentos a ter nestas. Uma das principais metodologias realizadas, e desenvolvida neste relatório, compreendeu a análise de produtos farmacêuticos estéreis, com a aplicação de Testes de Esterilidade, pelo método de STERITEST e método Directo, com resultados que demonstraram a importância destas técnicas, da avaliação do ambiente em que são realizadas e do operador que as executa. Os Testes de Promoção de Crescimento, foram também explorados neste trabalho, realizados não só para avaliação dos meios de cultura, onde foi possível analisar os requisitos e resultados obtidos, como também para validação de metodologias, nomeadamente, na validação de meios e fluidos de marcas diferentes para utilização no método STERITEST e na validação do método de filtração de membrana para Enumeração Microbiana de um produto não estéril. Estas validações possibilitaram a redução de custos e melhoria das condições da análise e metodologias aplicadas. Com a realização do estágio foi possível adquirir aptidões práticas, que aliadas ao conhecimento teórico obtido no mestrado, proporcionaram um crescimento a nível pessoal, científico e profissional.
Resumo:
There is an imminent need for rapid methods to detect and determine pathogenic bacteria in food products as alternatives to the laborious and time-consuming culture procedures. In this work, an electrochemical immunoassay using iron/gold core/shell nanoparticles (Fe@Au) conjugated with anti-Salmonella antibodies was developed. The chemical synthesis and functionalization of magnetic and gold-coated magnetic nanoparticles is reported. Fe@Au nanoparticles were functionalized with different self-assembled monolayers and characterized using ultraviolet-visible spectrometry, transmission electron microscopy, and voltammetric techniques. The determination of Salmonella typhimurium, on screen-printed carbon electrodes, was performed by square-wave anodic stripping voltammetry through the use of CdS nanocrystals. The calibration curve was established between 1×101 and 1×106 cells/mL and the limit of detection was 13 cells/mL. The developed method showed that it is possible to determine the bacteria in milk at low concentrations and is suitable for the rapid (less than 1 h) and sensitive detection of S. typhimurium in real samples. Therefore, the developed methodology could contribute to the improvement of the quality control of food samples.
Resumo:
Dissertação de Mestrado apresentado ao Instituto de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Auditoria, sob orientação da Doutora Alcina Portugal Dias
Resumo:
Environmental pollution continues to be an emerging study field, as there are thousands of anthropogenic compounds mixed in the environment whose possible mechanisms of toxicity and physiological outcomes are of great concern. Developing methods to access and prioritize the screening of these compounds at trace levels in order to support regulatory efforts is, therefore, very important. A methodology based on solid phase extraction followed by derivatization and gas chromatography-mass spectrometry analysis was developed for the assessment of four endocrine disrupting compounds (EDCs) in water matrices: bisphenol A, estrone, 17b-estradiol and 17a-ethinylestradiol. The study was performed, simultaneously, by two different laboratories in order to evaluate the robustness of the method and to increase the quality control over its application in routine analysis. Validation was done according to the International Conference on Harmonisation recommendations and other international guidelines with specifications for the GC-MS methodology. Matrix-induced chromatographic response enhancement was avoided by using matrix-standard calibration solutions and heteroscedasticity has been overtaken by a weighted least squares linear regression model application. Consistent evaluation of key analytical parameters such as extraction efficiency, sensitivity, specificity, linearity, limits of detection and quantification, precision, accuracy and robustness was done in accordance with standards established for acceptance. Finally, the application of the optimized method in the assessment of the selected analytes in environmental samples suggested that it is an expedite methodology for routine analysis of EDC residues in water matrices.
Resumo:
GOAL: The manufacturing and distribution of strips of instant thin - layer chromatography with silica gel (ITLC - SG) (reference method) is currently discontinued so there is a need for an alternative method f or the determination of radiochemical purity (RCP) of 99m Tc - tetrofosmin. This study aims to compare five alternative methods proposed by the producer to determine the RCP of 99m Tc - tetrofosmin. METHODS: Nineteen vials of tetrofosmin were radiolabelled with 99m Tc and the percentages of the RCP were determined. Five different methods were compared with the standard RCP testing method (ITLC - SG, 2x20 cm): Whatman 3MM (1x10 cm) with acetone and dichloro - methane (method 1); Whatman 3MM (1x1 0 cm) with ethyl acetate (method 2); aluminum oxide - coated plastic thin - layer chromatography (TLC) plate (1x10 cm) and ethanol (method 3); Whatman 3MM (2x20 cm) with acetone and dichloro - methane (method 4); solid - phase extraction method C18 cartridge (meth od 5). RESULTS: The average values of RCP were 95,30% ± 1,28% (method 1), 93,95 ± 0,61% (method 2), 96,85% ± 0,93% (method 3), 92,94% ± 0,99% (method 4) and 96,25% ± 2,57% (method 5) (n=12 each), and 93,15% ± 1,13% for the standard method (n=19). There we re statistical significant differences in the values obtained for methods 1 (P=0,001), 3 (P=0,000) and 5 (P=0,004), and there were no statistical significant differences in the values obtained for methods 2 (P=0,113) and 4 (P=0,327). CONCLUSION: From the results obtained, methods 2 and 4 showed a higher correlation with the standard method. Unlike method 4, method 2 is less time - consuming than the reference method and can overcome the problems associated with the solvent toxicity. The remaining methods (1, 3 and 5) tended to overestimate RCP value compared to the standard method.