23 resultados para Road Lighting Costs.

em Instituto Politécnico do Porto, Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Congestion management of transmission power systems has achieve high relevance in competitive environments, which require an adequate approach both in technical and economic terms. This paper proposes a new methodology for congestion management and transmission tariff determination in deregulated electricity markets. The congestion management methodology is based on a reformulated optimal power flow, whose main goal is to obtain a feasible solution for the re-dispatch minimizing the changes in the transactions resulting from market operation. The proposed transmission tariffs consider the physical impact caused by each market agents in the transmission network. The final tariff considers existing system costs and also costs due to the initial congestion situation and losses. This paper includes a case study for the 118 bus IEEE test case.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de Mestrado em Finanças Empresariais

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Química. Ramo optimização energética na indústria química.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Um túnel é uma obra subterrânea dimensionada com o objetivo de satisfazer diversas necessidades num mundo onde o planeamento urbano e a gestão de espaços ganha cada vez mais importância. A execução de este género de obras de engenharia pode ter várias finalidades, que podem ir desde a construção/reabilitação de redes de saneamento, abastecimento de água ou gás (túneis de pequeno diâmetro) até à construção/modernização de redes pedonais, rodoviárias ou ferroviárias, galerias mineiras, tuneis para barragens, etc. (túneis de grande diâmetro). As tuneladoras são uma das ferramentas de desmonte mais utilizadas na execução de obras subterrâneas. Existem no mercado vários tipos de máquinas tuneladoras, a sua escolha e dimensionamento depende de diversos fatores que devem ser cuidadosamente analisados, nomeadamente tipo de terreno a escavar, presença ou não de água na zona de escavação, dureza e/ou abrasividade das formações a atravessar, etc. Será feita uma abordagem aos princípios de funcionamento de este tipo de equipamentos, indicando o seu campo de aplicação dentro da respetiva tecnologia de escavação onde se inserem. Finalmente será desenvolvido o caso da empreitada: “Execução da Travessia do Rio Ave, da Estação Elevatória de Vila do Conde e dos Sistemas Elevatória da Aguçadoura e da Apúlia 4 - AR 44.0.08”, onde em alternativa ao desvio provisório do Rio Ave em Vila do Conde foi projetada a execução de duas travessias no diâmetro 1200 mm, uma delas escavadas maioritariamente em terreno aluvionar brando e a outra em terreno rochoso duro e abrasivo com recurso, em ambos casos, à utilização de máquina tuneladora. Através da avaliação do desempenho do equipamento escolhido para execução de este trabalho será estudada a eficiência da utilização deste tipo de equipamento. Com o objetivo de mostrar os custos associados à execução de obras de escavação subterrânea com recurso a utilização de máquinas tuneladoras, será feita uma análise económica e comparativa relativa aos dois casos de obra apresentados.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study a Bertrand oligopoly model with incomplete information about rivals' costs, where the uncertainty is given by a uniform distribution. We compute the Bayesian-Nash equilibrium of this game, the ex-ante expected profit and the ex-post profit of each firm. We see that, even though only one firm produces in equilibrium, all firms have a positive ex-ante expected profit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper considers an international trade under Bertrand model with differentiated products and with unknown production costs. The home government imposes a specific import tariff per unit of imports from the foreign firm. We prove that this tariff is decreasing in the expected production costs of the foreign firm and increasing in the production costs of the home firm. Furthermore, it is increasing in the degree of product substitutability. We also show that an increase in the tariff results in both firms increasing their prices, an increase in both expected sales and expected profits for the home firm, and a decrease in both expected sales and expected profits for the foreign firm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study Bertrand and Cournot oligopoly models with incomplete information about rivals’ costs, where the uncertainty is given by a uniform distribution. We compute the Bayesian- Nash equilibrium of both games, the ex-ante expected profits and the ex-post profits of each firm. We see that, in the price competition, even though only one firm produces in equilibrium, all firms have a positive ex-ante expected profit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Química - Ramo Tecnologias de Protecção Ambiental

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we consider a mixed market with uncertain demand, involving one private firm and one public firm with quadratic costs. The model is a two-stage game in which players choose to make their output decisions either in stage 1 or stage 2. We assume that the demand is unknown until the end of the first stage. We compute the output levels at equilibrium in each possible role. We also determine ex-ante and ex-post firms’ payoff functions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O consumo de energia a nível mundial tem atingido valores históricos, devido ao crescimento da população mundial e ao aumento do consumo per capita. Nesta medida é extremamente importante existirem alternativas para que a redução do consumo de energia de todos os países seja uma realidade, evitando também as consequências ambientais, em particular as alterações climáticas, resultantes da utilização intensiva de combustíveis fósseis. Portugal, tal como outros países da União Europeia, tem que cumprir metas, pelo que é urgente encontrarem-se soluções de forma a diminuir o consumo de energia sem interferir com o nosso dia-a-dia. A cidade do Porto, tal como qualquer cidade, precisa de imensa energia desde os transportes até à indústria, passando pelos edifícios. Os edifícios, residenciais e de serviços, são responsáveis por mais de 50% de energia primária consumida no concelho do Porto, sendo que aos edifícios residenciais corresponde um consumo de 1.473 GWh/ano de energia primária, o que é um valor elevado. Numa primeira parte deste trabalho foi efetuado um levantamento de informação caracterizando a cidade do Porto relativamente ao seu edificado e consumos energéticos. Numa segunda parte propuseram-se medidas para reduzir o consumo para cada tipo de utilização de energia, nomeadamente preparação de refeições, AQS (água quente sanitária), aquecimento ambiente, frio (frigorífico, arcas, etc.), outros e iluminação. Para cada um destes tipos de utilização estudou-se, sempre que possível, a evolução do longo do tempo (2004 a 2012) e possíveis cenários de evolução para o futuro. Para além disso, também se estudou a evolução do mix de produção de energia elétrica de 2004 até 2012 e previsões da evolução do mix para o futuro. Nesta análise foi tido em conta o aspeto ambiental contabilizando-se, sempre que possível, as emissões de poluentes resultantes do consumo de energia. Por fim, efetuou-se uma avaliação técnica, ambiental e económica das medidas propostas. Pode dizer-se que a maioria das medidas propostas a serem implementadas conduziria a uma redução do consumo de energia e consequentemente a uma diminuição das emissões de poluentes, em particular dos gases com efeito de estufa (CO2). Em termos técnicos a maioria das medidas pode ser aplicada embora algumas delas envolvam custos de investimento significativos. Dada a conjuntura atual, seria importante obter o financiamento necessário para a implementação das medidas propostas e a divulgação de medidas já existentes, tais como os programas para AQS e janelas eficientes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Performance evaluation increasingly assumes a more important role in any organizational environment. In the transport area, the drivers are the company’s image and for this reason it is important to develop and increase their performance and commitment to the company goals. This evaluation can be used to motivate driver to improve their performance and to discover training needs. This work aims to create a performance appraisal evaluation model of the drivers based on the multi-criteria decision aid methodology. The MMASSI (Multicriteria Methodology to Support Selection of Information Systems) methodology was adapted by using a template supporting the evaluation according to the freight transportation company in study. The evaluation process involved all drivers (collaborators being evaluated), their supervisors and the company management. The final output is a ranking of the drivers, based on their performance, for each one of the scenarios used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Em Portugal existem muitos espaços comerciais e industriais em que as necessidades térmicas de arrefecimento são muito superiores às necessidades de aquecimento devido aos ganhos internos que advêm da existência de equipamentos e da iluminação dos edifícios, assim como, da presença das pessoas. A instalação de sistemas convencionais de ar condicionado para espaços comerciais e industriais de grande dimensão está geralmente associada ao transporte de grandes caudais de ar, e consequentemente, a elevados consumos de energia primária, e também, elevados custos de investimento, de manutenção e de operação. O arrefecedor evaporativo é uma solução de climatização com elevada eficiência energética, cujo princípio de funcionamento promove a redução do consumo de energia primária nos edifícios. A metodologia utilizada baseou-se na criação de uma ferramenta informática de simulação do funcionamento de um protótipo de um arrefecedor evaporativo. Foi efetuada a modelação matemática das variáveis dinâmicas envolvidas, dos processos de transferência de calor e de massa, assim como dos balanços de energia que ocorrem no arrefecedor evaporativo. A ferramenta informática desenvolvida permite o dimensionamento do protótipo do arrefecedor evaporativo, sendo determinadas as caraterísticas técnicas (potência térmica, caudal, eficiência energética, consumo energético e consumo e água) de acordo com o tipo de edifício e com as condições climatéricas do ar exterior. Foram selecionados três dimensionamentos de arrefecedores evaporativos, representativos de condições reais de uma gama baixa, média e elevada de caudais de ar. Os resultados obtidos nas simulações mostram que a potência de arrefecimento (5,6 kW, 16,0 kW e 32,8 kW) e o consumo de água (8 l/h, 23,9 l/h e 48,96 l/h) aumentam com o caudal de ar do arrefecedor, 5.000 m3/h, 15.000 m3/h e 30.000 m3/h, respetivamente. A eficácia de permuta destes arrefecedores evaporativos, foi de 69%, 66% e 67%, respetivamente. Verificou-se que a alteração de zona climática de V1 para V2 implicou um aumento de 39% na potência de arrefecimento e de 20% no consumo de água, e que, a alteração de zona climática de V2 para V3 implicou um aumento de 39% na potência de arrefecimento e de 39% no consumo de água. O arrefecedor evaporativo apresenta valores de consumo de energia elétrica entre 40% a 80% inferiores aos dos sistemas de arrefecimento convencionais, sendo este efeito mais intenso quando a zona climática de verão se torna mais severa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A utilização pouco eficiente da energia representa um elevado encargo para qualquer país, seja do ponto de vista económico, social ou ambiental. Em Portugal a iluminação pública tem um importante peso nas despesas correntes dos municípios. Deste modo, torna-se imperativo agir de modo a aumentar a sustentabilidade energética e diminuir os gastos com a iluminação pública. Os municípios precisam de encontrar soluções que permitam reduzir os consumos, mantendo níveis de segurança e conforto necessários às populações. Neste sentido, este trabalho propõe-se estudar esta problemática, apresentando soluções, de modo a obter-se uma maior eficiência energética desta para as instalações e, consequentemente, conduzir a uma diminuição das emissões de CO2 durante o período de utilização das mesmas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A presente dissertação tem como principal propósito avaliar o desempenho energético e a qualidade do ar interior do edifício principal do Parque Biológico de Vila Nova de Gaia (PBG). Para esse efeito, este estudo relaciona os termos definidos na legislação nacional em vigor até à presente data, e referentes a esta área de atuação, em particular, os presentes no SCE, RSECE, RCCTE e RSECE-QAI. Para avaliar o desempenho energético, procedeu-se numa primeira fase ao processo de auditoria no local e posteriormente à realização de uma simulação dinâmica detalhada, cuja modelação do edifício foi feita com recurso ao software DesignBuilder. Após a validação do modelo simulado, por verificação do desvio entre os consumos energéticos registados nas faturas e os calculados na simulação, igual a 5,97%, foi possível efetuar a desagregação dos consumos em percentagem pelos diferentes tipos de utilizações. Foi também possível determinar os IEE real e nominal, correspondendo a 29,9 e 41.3 kgep/m2.ano, respetivamente, constatando-se através dos mesmos que o edifício ficaria dispensado de implementar um plano de racionalização energética (PRE) e que a classe energética a atribuir é a C. Contudo, foram apresentadas algumas medidas de poupança de energia, de modo a melhorar a eficiência energética do edifício e reduzir a fatura associada. Destas destacam-se duas propostas, a primeira propõe a alteração do sistema de iluminação interior e exterior do edifício, conduzindo a uma redução no consumo de eletricidade de 47,5 MWh/ano, com um período de retorno de investimento de 3,5 anos. A segunda está relacionada com a alteração do sistema de produção de água quente para o aquecimento central, através do incremento de uma caldeira a lenha ao sistema atual, que prevê uma redução de 50 MWh no consumo de gás natural e um período de retorno de investimento de cerca de 4 anos. Na análise realizada à qualidade do ar interior (QAI), os parâmetros quantificados foram os exigidos legalmente, excetuando os microbiológicos. Deste modo, para os parâmetros físicos, temperatura e humidade relativa, obtiveram-se os resultados médios de 19,7ºC e 66,9%, respetivamente, ligeiramente abaixo do previsto na legislação (20,0ºC no período em que foi feita a medição, inverno). No que diz respeito aos parâmetros químicos, os valores médios registados para as concentrações de dióxido de carbono (CO2), monóxido de carbono (CO), ozono (O3), formaldeído (HCHO), partículas em suspensão (PM10) e radão, foram iguais a 580 ppm, 0,2 ppm, 0,06 ppm, 0,01 ppm, 0,07 mg/m3 e 196 Bq/m3, respetivamente, verificando-se que estão abaixo dos valores máximos de referência presentes no regulamento (984 ppm, 10,7 ppm, 0,10 ppm, 0,08 ppm, 0,15 mg/m3 e 400 Bq/m3). No entanto, o parâmetro relativo aos compostos orgânicos voláteis (COV) teve um valor médio igual a 0,84 ppm, bastante acima do valor máximo de referência (0,26 ppm). Neste caso, terá que ser realizada uma nova série de medições utilizando meios cromatográficos, para avaliar qual(ais) são o(s) agente(s) poluidor(es), de modo a eliminar ou atenuar as fontes de emissão.