13 resultados para RELATIVE AIR HUMIDITY
em Instituto Politécnico do Porto, Portugal
Resumo:
This study aimed to characterize air pollution and the associated carcinogenic risks of polycyclic aromatic hydrocarbon (PAHs) at an urban site, to identify possible emission sources of PAHs using several statistical methodologies, and to analyze the influence of other air pollutants and meteorological variables on PAH concentrations.The air quality and meteorological data were collected in Oporto, the second largest city of Portugal. Eighteen PAHs (the 16 PAHs considered by United States Environment Protection Agency (USEPA) as priority pollutants, dibenzo[a,l]pyrene, and benzo[j]fluoranthene) were collected daily for 24 h in air (gas phase and in particles) during 40 consecutive days in November and December 2008 by constant low-flow samplers and using polytetrafluoroethylene (PTFE) membrane filters for particulate (PM10 and PM2.5 bound) PAHs and pre-cleaned polyurethane foam plugs for gaseous compounds. The other monitored air pollutants were SO2, PM10, NO2, CO, and O3; the meteorological variables were temperature, relative humidity, wind speed, total precipitation, and solar radiation. Benzo[a]pyrene reached a mean concentration of 2.02 ngm−3, surpassing the EU annual limit value. The target carcinogenic risks were equal than the health-based guideline level set by USEPA (10−6) at the studied site, with the cancer risks of eight PAHs reaching senior levels of 9.98×10−7 in PM10 and 1.06×10−6 in air. The applied statistical methods, correlation matrix, cluster analysis, and principal component analysis, were in agreement in the grouping of the PAHs. The groups were formed according to their chemical structure (number of rings), phase distribution, and emission sources. PAH diagnostic ratios were also calculated to evaluate the main emission sources. Diesel vehicular emissions were the major source of PAHs at the studied site. Besides that source, emissions from residential heating and oil refinery were identified to contribute to PAH levels at the respective area. Additionally, principal component regression indicated that SO2, NO2, PM10, CO, and solar radiation had positive correlation with PAHs concentrations, while O3, temperature, relative humidity, and wind speed were negatively correlated.
Resumo:
Asthma is a chronic inflammatory disorder of the respiratory airways affecting people of all ages, and constitutes a serious public health problem worldwide (6). Such a chronic inflammation is invariably associated with injury and repair of the bronchial epithelium known as remodelling (11). Inflammation, remodelling, and altered neural control of the airways are responsible for both recurrent exacerbations of asthma and increasingly permanent airflow obstruction (11, 29, 34). Excessive airway narrowing is caused by altered smooth muscle behaviour, in close interaction with swelling of the airway walls, parenchyma retractile forces, and enhanced intraluminal secretions (29, 38). All these functional and structural changes are associated with the characteristic symptoms of asthma – cough, chest tightness, and wheezing –and have a significant impact on patients’ daily lives, on their families and also on society (1, 24, 29). Recent epidemiological studies show an increase in the prevalence of asthma, mainly in industrial countries (12, 25, 37). The reasons for this increase may depend on host factors (e.g., genetic disposition) or on environmental factors like air pollution or contact with allergens (6, 22, 29). Physical exercise is probably the most common trigger for brief episodes of symptoms, and is assumed to induce airflow limitations in most asthmatic children and young adults (16, 24, 29, 33). Exercise-induced asthma (EIA) is defined as an intermittent narrowing of the airways, generally associated with respiratory symptoms (chest tightness, cough, wheezing and dyspnoea), occurring after 3 to 10 minutes of vigorous exercise with a maximal severity during 5 to 15 minutes after the end of the exercise (9, 14, 16, 24, 33). The definitive diagnosis of EIA is confirmed by the measurement of pre- and post-exercise expiratory flows documenting either a 15% fall in the forced expiratory volume in 1 second (FEV1), or a ≥15 to 20% fall in peak expiratory flow (PEF) (9, 24, 29). Some types of physical exercise have been associated with the occurrence of bronchial symptoms and asthma (5, 15, 17). For instance, demanding activities such as basketball or soccer could cause more severe attacks than less vigorous ones such as baseball or jogging (33). The mechanisms of exercise-induced airflow limitations seem to be related to changes in the respiratory mucosa induced by hyperventilation (9, 29). The heat loss from the airways during exercise, and possibly its post-exercise rewarming may contribute to the exercise-induced bronchoconstriction (EIB) (27). Additionally, the concomitant dehydration from the respiratory mucosa during exercise leads to an increased interstitial osmolarity, which may also contribute to bronchoconstriction (4, 36). So, the risk of EIB in asthmatically predisposed subjects seems to be higher with greater ventilation rates and the cooler and drier the inspired air is (23). The incidence of EIA in physically demanding coldweather sports like competitive figure skating and ice hockey has been found to occur in up to 30 to 35% of the participants (32). In contrast, swimming is often recommended to asthmatic individuals, because it improves the functionality of respiratory muscles and, moreover, it seems to have a concomitant beneficial effect on the prevalence of asthma exacerbations (14, 26), supporting the idea that the risk of EIB would be smaller in warm and humid environments. This topic, however, remains controversial since the chlorified water of swimming pools has been suspected as a potential trigger factor for some asthmatic patients (7, 8, 20, 21). In fact, the higher asthma incidence observed in industrialised countries has recently been linked to the exposition to chloride (7, 8, 30). Although clinical and epidemiological data suggest an influence of humidity and temperature of the inspired air on the bronchial response of asthmatic subjects during exercise, some of those studies did not accurately control the intensity of the exercise (2, 13), raising speculation of whether the experienced exercise overload was comparable for all subjects. Additionally, most of the studies did not include a control group (2, 10, 19, 39), which may lead to doubts about whether asthma per se has conditioned the observed results. Moreover, since the main targeted age group of these studies has been adults (10, 19, 39), any extrapolation to childhood/adolescence might be questionable regarding the different lung maturation. Considering the higher incidence of asthma in youngsters (30) and the fact that only the works of Amirav and coworkers (2, 3) have focused on this age group, a scarcity of scientific data can be identified. Additionally, since the main environmental trigger factors, i.e., temperature and humidity, were tested separately (10, 28, 39) it would be useful to analyse these two variables simultaneously because of their synergic effect on water and heat loss by the airways (31, 33). It also appears important to estimate the airway responsiveness to exercise within moderate environmental ranges of temperature and humidity, trying to avoid extreme temperatures and humidity conditions used by others (2, 3). So, the aim of this study was to analyse the influence of moderate changes in air temperature and humidity simultaneously on the acute ventilatory response to exercise in asthmatic children. To overcome the above referred to methodological limitations, we used a 15 minute progressive exercise trial on a cycle ergometer at 3 different workload intensities, and we collected data related to heart rate, respiratory quotient, minute ventilation and oxygen uptake in order to ensure that physiological exercise repercussions were the same in both environments. The tests were done in a “normal” climatic environment (in a gymnasium) and in a hot and humid environment (swimming pool); for the latter, direct chloride exposition was avoided.
Resumo:
O desenvolvimento deste trabalho teve como objectivo a optimização de um sistema de climatização industrial, constituído por quatro centrais de climatização adiabáticas, que apresentam limitações de capacidade de arrefecimento, controlo e eficiência. Inicialmente foi necessária a pesquisa bibliográfica e recolha de informação relativa à indústria têxtil e ao processo de arrefecimento evaporativo. Numa fase posterior foram recolhidos e analisados os diversos dados essenciais à compreensão do binómio edifício/sistema de climatização, para a obtenção de possíveis hipóteses de optimização. Da fase de recolha de informações e dados, destaca-se, também, a realização de análises à qualidade do ar interior (QAI). As optimizações seleccionadas como passíveis de implementação, foram estudadas e analisadas com o auxílio do software de simulação energética dinâmica DesignBuilder e os resultados obtidos foram devidamente trabalhados e ajustados de modo a permitir uma assimilação amigável e de fácil interpretação das suas vantagens e desvantagens, tendo ainda sido objecto de estudo de viabilidade económica. A optimização proposta reflecte uma melhoria substancial das condições interiores ao nível da temperatura e humidade relativa, resultando, ainda assim, numa redução de consumos energéticos na ordem dos 23 % (490.337 kWh), isto é, uma poupança anual de 42.169 € aos custos de exploração e com um período de retorno de 1 ano e 11 meses.
Resumo:
A Qualidade do Ar Interior (QAI) é um fator de grande preocupação. A importância de manter um ambiente salubre é mais acentuada em estabelecimentos escolares (EE), tendo em conta, que no interior destes permanecem crianças durante um elevado período de tempo. É fundamental garantir uma boa QAI nos edifícios escolares, de forma a salvaguardar a saúde, o bem-estar e o conforto dos ocupantes, bem como, não comprometer o seu desempenho escolar. Recentemente, foram construídos novos edifícios escolares e alguns dos existentes foram alvo de obras de remodelação. Contudo, a crescente tendência em construir edifícios cada vez mais herméticos, com vista à diminuição dos gastos de energia, origina problemas como a reduzida ventilação dos espaços. Vários estudos têm demonstrado a influência das atividades de limpeza na QAI. No entanto, verifica-se que na maioria das escolas não existem ainda procedimentos de limpeza padronizados. A falta de instruções de trabalho e a ausência de formação às assistentes operacionais pode comprometer a eficácia dos procedimentos de higienização, o que poderá ter influência na QAI dos espaços. Este estudo teve como principal objetivo avaliar a QAI em escolas básicas de 1.º ciclo. Foram contemplados no estudo fatores como a tipologia do edifício, a ocupação das salas e as atividades de limpeza. Procedeu-se à caracterização dos EE e à monitorização de parâmetros ambientais, como a temperatura do ar, a humidade relativa, a velocidade do ar, o dióxido de carbono, o monóxido de carbono, as partículas, os microrganismos mesófilos totais e os fungos. Estes parâmetros foram avaliados nas salas com ocupação, sem ocupação e durante a implementação de um plano de higienização. A ventilação inadequada parece ser o fator que mais condiciona a QAI das salas de aula avaliadas. Registaram-se elevadas concentrações de dióxido de carbono e de microrganismos mesófilos totais, que parecem estar relacionados com a permanência dos ocupantes nos locais e com a falta de ventilação adequada dos espaços. A concentração de dióxido de carbono foi mais elevada em edifícios recentes. Os picos elevados na concentração de partículas parecem estar associados com as atividades dos ocupantes. Obtiveram-se concentrações menores de fungos e de microrganismos mesófilos totais ao longo da implementação do plano de higienização, o que poderá significar que os procedimentos de limpeza contribuem para reduzir os níveis de contaminação dos espaços interiores. No entanto, tendo em conta, que a concentração de microrganismos mesófilos totais permaneceu elevada, as operações de limpeza parecem não ser suficientes para garantir uma boa QAI. O aumento da ventilação dos espaços poderia contribuir significativamente para a melhoria da QAI dos espaços avaliados.
Resumo:
Em consequência da elevada permanência das pessoas em espaços interiores de edifícios, surge actualmente uma maior preocupação com o conforto térmico e qualidade do ar no seu interior. Apesar da grande evolução tecnológica dos sistemas de conservação de energia térmica e controle da qualidade do ar interior (QAI) na construção, os edifícios existentes acabam por não acompanhar essa evolução, apresentando um comportamento térmico e higrométrico que por vezes podem comprometer quer o conforto, quer a saúde e actividades dos seus utilizadores. Nos estabelecimentos de ensino, o comportamento termo-higrométrico assume um papel importante face à permanência diária de um grande número de crianças e jovens no seu interior. Com este estudo pretende-se caracterizar a qualidade do ambiente no interior de oito escolas, através de uma análise aos principais parâmetros de natureza higrotérmica de oito salas de aulas, tais como: a temperatura (ambiente e superficial), a humidade relativa (do ambiente e da superfície da envolvente exterior opaca), bem como o nível de escoamento do ar interior. Neste trabalho são apresentados os resultados das medições efectuadas em oito salas de aula que permitiram a comparação de características termo-higrométricas entre as respectivas escolas. É ainda apresentada a estimativa do nível de conforto térmico face às condições ambientais registadas, bem como a análise do risco de ocorrência de condensações interiores.
Resumo:
O objectivo principal deste trabalho é a realização de uma auditoria, à qualidade do ar interior (QAI), a um edifício de serviços – COCIGA, SA, tendo como base o Regulamento dos Sistemas Energéticos de Climatização dos Edifícios (RSECE). A auditoria QAI implica a medição de vários parâmetros físicos, químicos, microbiológicos e também a inspecção aos componentes do sistema de climatização com a finalidade de averiguar o seu estado de limpeza e manutenção. Assim, foram seleccionados 3 espaços, para a realização de amostragens designados por Comercial - Produtos, AVAC e Mezaninne das oficinas, nos quais foi efectuada a medição de diversos parâmetros, de acordo com as imposições do RSECE, utilizando medidores portáteis ou recorrendo a métodos analíticos. Relativamente aos parâmetros físicos, registaram-se valores de temperatura, para os três espaços estudados, entre os 21 e os 24 ºC e valores médios de humidade relativa de cerca de 50 %. Outro parâmetro medido, e de grande importância para garantir o conforto dos ocupantes, foi a velocidade do ar nos postos de trabalho. De acordo com o RSECE este valor não deve ser superior a 0,2 m/s, o que se verificou em todos os pontos medidos. O último parâmetro físico medido foi a concentração de partículas (PM10) tendo-se obtido valores de cerca de 23 μg/m3ar, valor bastante inferior ao máximo permitido pelo RSECE (150 μg/m3ar). Também no que diz respeito aos parâmetros químicos, ou seja, CO2, CO, formaldeído e ozono, não se verificaram valores superiores aos regulamentares. No caso do CO2, o valor máximo encontrado, nestes três espaços, foi de 745 ppm na Mezaninne das Oficinas e para o CO, na zona AVAC com uma concentração de 0,73 ppm. A medição do formaldeído registou valores perto dos 45 μg/m3ar e o ozono apenas foi detectado, em concentração muito reduzida, na zona Comercial – Produtos. Por fim, as concentrações de bactérias e fungos, de acordo com o RSECE, não devem ultrapassar as 500 UFC/m3ar (parâmetros microbiológicos). Em qualquer dos espaços, os valores medidos foram inferiores ao máximo legal, não ultrapassando as 50 UFC/m3ar. Da avaliação do projecto AVAC, e através da medição dos caudais de insuflação/ extracção em cada zona, concluiu-se que os seus valores não estão de acordo com os valores do projecto inicial que poderá ser imputada a uma insuficiência no funcionamento do sistema detectada na altura das medições. No que diz respeito ao estado de limpeza do sistema AVAC, apenas foi possível inspeccionar as unidades de tratamento de ar, tendo-se constatado que se encontram em boas condições. Ou seja, do ponto de vista do RSECE, e referindo-nos apenas à vertente da Qualidade do Ar Interior, o edifício em causa, cumpre todos os limites impostos para as concentrações de poluentes mas, apresenta algumas deficiências no que respeita aos caudais de ar novo insuflados em cada espaço.
Resumo:
The aim of this work was to assess ultrafine particles (UFP) number concentrations in different microenvironments of Portuguese preschools and to estimate the respective exposure doses of UFP for 3–5-year-old children (in comparison with adults). UFP were sampled both indoors and outdoors in two urban (US1, US2) and one rural (RS1) preschool located in north of Portugal for 31 days. Total levels of indoor UFP were significantly higher at the urban preschools (mean of 1.82x104 and 1.32x104 particles/cm3 at US1 an US2, respectively) than at the rural one (1.15x104 particles/cm3). Canteens were the indoor microenvironment with the highest UFP (mean of 5.17x104, 3.28x104, and 4.09x104 particles/cm3 at US1, US2, and RS1), whereas the lowest concentrations were observed in classrooms (9.31x103, 11.3x103, and 7.14x103 particles/cm3 at US1, US2, and RS1). Mean indoor/outdoor ratios (I/O) of UFP at three preschools were lower than 1 (0.54–0.93), indicating that outdoor emissions significantly contributed to UFP indoors. Significant correlations were obtained between temperature, wind speed, relative humidity, solar radiation, and ambient UFP number concentrations. The estimated exposure doses were higher in children attending urban preschools; 3–5-year-old children were exposed to 4–6 times higher UFP doses than adults with similar daily schedules.
Resumo:
A prática de exercício físico é considerado condição essencial para a manutenção de uma boa saúde. A faixa etária de frequentadores de ginásios inclui utentes desde os 8 aos 80 anos, incluindo assim os grupos mais sensíveis à poluição do ar interior. Embora exista legislação específica para ginásios, nomeadamente para as condições de implementação, a mesma é reduzida e não contempla a qualidade do ar interior (QAI). O objetivo geral deste estudo consistiu na avaliação da QAI de quatro ginásios existentes na área metropolitana do Porto. O período de amostragem realizou-se entre 2 de Maio e 20 de Junho 2014 e, após a caracterização dos ginásios, foram monitorizados os seguintes parâmetros: partículas ultrafinas (< 100 nm), matéria particulada suspensa no ar de frações PM1, PM2,5, PM4 e PM10, dióxido de carbono, monóxido de carbono, ozono, compostos orgânicos voláteis, formaldeído, temperatura ambiente e humidade relativa durante 24 h/dia em salas com diferentes actividades (sala de musculação e cardiofitness e sala de aulas de grupo). Os resultados da avaliação dos parâmetros físicos e químicos foram comparados com os limiares de proteção e margem de tolerância do Decreto-Lei nº 118/2013 de 20 de Agosto, a Portaria nº 353-A/2013 de 4 de Dezembro e o Diploma que regula a construção, instalação e funcionamento dos ginásios. Os poluentes com maiores níveis de excedência são o dióxido de carbono, compostos orgânicos voláteis e as partículas PM2,5. As excedências devem-se essencialmente à sobrelotação das salas, excesso de atividade física e ventilação insuficiente. A localização da instalação dos ginásios é também um fator de extrema importância, sendo recomendado que este se situe em local pouco influenciado pelo tráfego automóvel, assim como, afastado de locais de possível interferência devido às atividades presentes, como é o caso da restauração existente em centros comerciais.
Resumo:
A eficiência energética e a preocupação com a sustentabilidade têm vindo a ganhar preponderância na sociedade moderna. Este trabalho é uma contribuição para esta tendência onde se pretendeu avaliar e sugerir alterações ao sistema de climatização do edifício Biorama do Parque Biológico de Vila Nova de Gaia (PBG). Procedeu-se em primeiro lugar a uma caracterização física, química e geográfica dos 5 biomas constituintes do Biorama. Para isso, recorreu-se a documentos fornecidos pelo próprio PBG, visitas ao local e registo de medições de alguns parâmetros (temperatura, humidade relativa, qualidade do ar). Posteriormente foi realizado o balanço térmico dos edifícios, de acordo com a legislação em vigor, recorrendo a expressões e conceitos teóricos. Foram determinados valores dos ganhos térmicos de aquecimento de 15811, 10694, 7939, 9233, e 6621 kWh/ano para Floresta tropical, Mesozoico, Dunas, Savana e Deserto, respetivamente. Foram igualmente determinados valores dos ganhos térmicos no verão de 7093, 4798, 3560, 4144 e 2971 kWh na Floresta tropical, no Mesozoico, nas Dunas, na Savana e no Deserto, respetivamente. As cargas térmicas de aquecimento foram 149, 125, 47, 60 e 51 kW na Floresta tropical, no Mesozoico, nas Dunas, na Savana e no Deserto, respetivamente. As cargas térmicas de arrefecimento foram iguais a 59, 57, 47, 35 e 36 kW na Floresta tropical, no Mesozoico, nas Dunas, na Savana e no Deserto, respetivamente. Algumas soluções são avançadas, bem como alternativas comportamentais de modo a corrigir alguns problemas identificados. Uma proposta é a da instalação de painéis solares e acumuladores de calor, com os quais se estima um ganho médio conjunto de 500 W em cada bioma, e representam um investimento de 1050 euros e terão um retorno de 1 ano. Em relação à humidade é sugerido a utilização mais eficaz dos aspersores existentes e a utilização de esponjas, para fazer subir a humidade relativa para valores superiores a 80%. Em sentido inverso, no inverno, propõem-se a utilização de material higroscópico para fazer baixar a humidade relativa em cerca de 5%. Os custos com os suportes e o material higroscópico rondam os 250 €. Por fim, é sugerido a instalação de um aparelho de ar condicionado de 16 000 BTU no corredor de ligação, pois é a única forma de garantir condições de conforto térmico. Esta proposta de arrefecimento com ar condicionado e ainda o recurso a uma cortina de lâminas de plástico, que servem para efetuar uma separação mais eficiente entre ar frio e ar quente, têm um custo aproximado de 350 €. É ainda sugerida a utilização de lonas ou de uma planta trepadeira com um custo por planta de 5€, nas coberturas dos telhados virados a sul, sendo que a zona do corredor deverá ser totalmente coberta, a fim de evitar a exposição solar direta.
Resumo:
Na União Europeia, a energia utilizada nos edifícios é responsável por uma grande parte do consumo total, cerca de 40%, de toda a energia produzida, contribuindo em grande escala para as emissões de gases de efeito de estufa, como o CO2. [ADENE, 2014]. A minimização deste consumo, durante o período de ciclo de vida de um edifício, é um grande desafio associado ao ambiente e à economia. Na atualidade assistimos, cada vez mais, ao emergir de novas tecnologias. Faz parte dessa realidade, o crescimento e o desenvolvimento das UTA’s, que surgem como resposta do ser humano pela busca de otimização da sua zona de conforto, da qualidade de ar interior e da eficiência energética. Assim, para que não se sacrifique o conforto térmico, há que conciliar a qualidade de ar interior com a energia dispensada para climatizar os espaços. Para ajudar à minimização de CO2 em conjunto com uma eficiência energética e conforto térmico, traduzindo-se numa melhor qualidade de ar no interior de espaços climatizados, surge o objetivo de implementar uma aplicação através do software LabVIEW para prever uma experiência real. Como solução, recorreu-se a modelos matemáticos que traduzissem os vários balanços térmicos, balanços de massa e de CO2. As principais conclusões deste trabalho foram: validação do comportamento do modelo matemático da temperatura; validação do comportamento do modelo matemático de CO2; humidade relativa com 25% de registos válidos.
Resumo:
A presente dissertação tem como principal propósito avaliar o desempenho energético e a qualidade do ar interior do edifício principal do Parque Biológico de Vila Nova de Gaia (PBG). Para esse efeito, este estudo relaciona os termos definidos na legislação nacional em vigor até à presente data, e referentes a esta área de atuação, em particular, os presentes no SCE, RSECE, RCCTE e RSECE-QAI. Para avaliar o desempenho energético, procedeu-se numa primeira fase ao processo de auditoria no local e posteriormente à realização de uma simulação dinâmica detalhada, cuja modelação do edifício foi feita com recurso ao software DesignBuilder. Após a validação do modelo simulado, por verificação do desvio entre os consumos energéticos registados nas faturas e os calculados na simulação, igual a 5,97%, foi possível efetuar a desagregação dos consumos em percentagem pelos diferentes tipos de utilizações. Foi também possível determinar os IEE real e nominal, correspondendo a 29,9 e 41.3 kgep/m2.ano, respetivamente, constatando-se através dos mesmos que o edifício ficaria dispensado de implementar um plano de racionalização energética (PRE) e que a classe energética a atribuir é a C. Contudo, foram apresentadas algumas medidas de poupança de energia, de modo a melhorar a eficiência energética do edifício e reduzir a fatura associada. Destas destacam-se duas propostas, a primeira propõe a alteração do sistema de iluminação interior e exterior do edifício, conduzindo a uma redução no consumo de eletricidade de 47,5 MWh/ano, com um período de retorno de investimento de 3,5 anos. A segunda está relacionada com a alteração do sistema de produção de água quente para o aquecimento central, através do incremento de uma caldeira a lenha ao sistema atual, que prevê uma redução de 50 MWh no consumo de gás natural e um período de retorno de investimento de cerca de 4 anos. Na análise realizada à qualidade do ar interior (QAI), os parâmetros quantificados foram os exigidos legalmente, excetuando os microbiológicos. Deste modo, para os parâmetros físicos, temperatura e humidade relativa, obtiveram-se os resultados médios de 19,7ºC e 66,9%, respetivamente, ligeiramente abaixo do previsto na legislação (20,0ºC no período em que foi feita a medição, inverno). No que diz respeito aos parâmetros químicos, os valores médios registados para as concentrações de dióxido de carbono (CO2), monóxido de carbono (CO), ozono (O3), formaldeído (HCHO), partículas em suspensão (PM10) e radão, foram iguais a 580 ppm, 0,2 ppm, 0,06 ppm, 0,01 ppm, 0,07 mg/m3 e 196 Bq/m3, respetivamente, verificando-se que estão abaixo dos valores máximos de referência presentes no regulamento (984 ppm, 10,7 ppm, 0,10 ppm, 0,08 ppm, 0,15 mg/m3 e 400 Bq/m3). No entanto, o parâmetro relativo aos compostos orgânicos voláteis (COV) teve um valor médio igual a 0,84 ppm, bastante acima do valor máximo de referência (0,26 ppm). Neste caso, terá que ser realizada uma nova série de medições utilizando meios cromatográficos, para avaliar qual(ais) são o(s) agente(s) poluidor(es), de modo a eliminar ou atenuar as fontes de emissão.
Resumo:
O estágio descrito por este relatório efetuou-se na fábrica Massas 1 da empresa Cerealis Produtos Alimentares S.A., situada em Águas Santas e teve como principal objetivo o estudo do impacto energético da instalação de um sistema de Aquecimento, Ventilação e Ar Condicionado (AVAC) nos Consumos Específicos de Energia (CEE) da fábrica. Com o intuito de promover a familiarização com o ambiente da empresa e com o próprio processo produtivo efetuaram-se várias visitas à fábrica Massas 1. Acompanhou-se a produção diária realizada e o funcionamento do equipamento, e pôde-se questionar os colaboradores da fábrica sobre o processo. Ao longo do tempo de estágio recolheram-se vários dados, nomeadamente valores de temperatura e de humidade relativa do ar da fábrica, consumos de energia elétrica e de gás natural, volumes de produção e dados relativos à qualidade da massa. Relativamente ao CEE, fez-se uma comparação entre quatro meses abrangidos pelo presente trabalho, nos quais o novo sistema AVAC já se encontrava em funcionamento, e os meses homólogos do ano anterior. Confrontando os valores obtidos verificou-se uma diminuição de 2,6% no valor global de CEE, apresentando este um valor de 82,51 kgep/ton até ao mês de Setembro do presente ano. Analisando os valores de CEE da energia elétrica e do gás natural separadamente, constatou-se igualmente uma diminuição dos seus valores em 1,4% e 4,2%, respetivamente. Efetuou-se também uma comparação entre o antigo e o novo sistema AVAC no que respeita às condições de temperatura e de humidade do ar interior da fábrica. Para isso efetuaram-se medições de temperatura e de humidade relativa do ar interior da fábrica, tendo-se concluído que após a instalação do novo AVAC ocorreu uma diminuição da temperatura e um aumento da humidade relativa do ar, tal como desejado. Antes da instalação do novo AVAC a gama de temperaturas no interior da fábrica era de 32,4°C a 39,7°C e a gama de humidades de 39,7% a 58,6%. Já depois da instalação, a gama de temperaturas e de humidades passou a ser de 26,6°C a 33,5°C e de 45,8% a 59,1%, respetivamente Realizou-se ainda uma comparação relativa à qualidade do produto final, tendose para isso analisado ensaios de cozedura e de teor de humidade. Desta comparação, concluiu-se que de uma forma geral houve um aumento dos teores de humidade dos diferentes tipos de massa, encontrando-se agora uma maior percentagem dentro da gama de valores pretendida que se situa entre os 11,5% e os 12,5%.
Resumo:
Nos últimos anos tem-se assistido à introdução de novos dispositivos de medição da poluição do ar baseados na utilização de sensores de baixo custo. A utilização menos complexa destes sistemas, possibilita a obtenção de dados com elevada resolução temporal e espacial, abrindo novas oportunidades para diferentes metodologias de estudos de monitorização da poluição do ar. Apesar de apresentarem capacidades analíticas distantes dos métodos de referência, a utilização destes sensores tem sido sugerida e incentivada pela União Europeia no âmbito das medições indicativas previstas na Diretiva 2008/50/CE, com uma incerteza expandida máxima de 25%. O trabalho desenvolvido no âmbito da disciplina de Projeto consistiu na escolha, caracterização e utilização em medições reais de um sensor de qualidade do ar, integrado num equipamento protótipo desenvolvido com esse fim, visando obtenção uma estimativa da incerteza de medição associada à utilização deste dispositivo através da aplicação da metodologia de demonstração de equivalência de métodos de medição de qualidade do ar definida pela União Europeia. A pesquisa bibliográfica realizada permitiu constatar que o monóxido de carbono é neste momento o parâmetro de qualidade do ar que permite ser medido de forma mais exata através da utilização de sensores, nomeadamente o sensor eletroquímico da marca Alphasense, modelo COB4, amplamente utilizado em projetos de desenvolvimento neste cotexto de monitorização ambiental. O sensor foi integrado num sistema de medição com o objetivo de poder ser utlizado em condições de autonomia de fornecimento de energia elétrica, aquisição interna dos dados, tendo em consideração ser o mais pequeno possível e de baixo custo. Foi utlizado um sistema baseado na placa Arduino Uno com gravação de dados em cartão de memória SD, baterias e painel solar, permitindo para além do registo das tensões elétricas do sensor, a obtenção dos valores de temperatura, humidade relativa e pressão atmosférica, com um custo global a rondar os 300 euros. Numa primeira fase foram executados um conjunto de testes laboratoriais que permitiram a determinação de várias características de desempenho em dois sensores iguais: tempo de resposta, a equação modelo do sensor, avaliação da repetibilidade, desvio de curto e longo termo, interferência da temperatura e histerese. Os resultados demonstraram um comportamento dos sensores muito linear, com um tempo de resposta inferior a um minuto e com uma equação modelo do sensor dependente da variação da temperatura. A estimativa da incerteza expandida laboratorial ficou, para ambos os sensores, abaixo dos 10%. Após a realização de duas campanhas reais de medição de CO em que os valores foram muito baixos, foi realizada uma campanha de quinze dias num parque de estacionamento subterrâneo que permitiu a obtenção de concentrações suficientemente elevadas e a comparação dos resultados dos sensores com o método de referência em toda a gama de medição (0 a 12 mol.mol-1). Os valores de concentração obtidos pelos dois sensores demonstraram uma excelente correlação com o método de referência (r2≥0,998), obtendo-se resultados para a estimativa da incerteza expandida de campo inferiores aos obtidos para a incerteza laboratorial, cumprindo o objetivo de qualidade de dados definido para as medições indicativas de incerteza expandida máxima de 25%. Os resultados observados durante o trabalho realizado permitiram confirmar o bom desempenho que este tipo de sensor pode ter no âmbito de medições de poluição do ar com um caracter mais indicativo.