6 resultados para Geographic and dimension errors
em Instituto Politécnico do Porto, Portugal
Resumo:
A new flow-injection analytical procedure is proposed for the determination of the total amount of polyphenols in wines; the method is based on the formation of a colored complex between 4-aminoantipyrine and phenols, in the presence of an oxidizing reagent. The oxidizing agents hexacyanoferrate(III), peroxodisulfate, and tetroxoiodate(VII) were tested. Batch trials were first performed to select appropriate oxidizing agents, pH, and concentration ratios of reagents, on the basis of their effect on the stability of the colored complex. Conditions selected as a result of these trials were implemented in a flow-injection analytical system in which the influence of injection volume, flow rate, and reaction- coil length, was evaluated. Under the optimum conditions the total amount of polyphenols, expressed as gallic acid, could be determined within a concentration range of 36 to 544 mg L–1, and with a sensitivity of 344 L mol–1 cm–1 and an RSD <1.1%. The reproducibility of analytical readings was indicative of standard deviations <2%. Interference from sugars, tartaric acid, ascorbic acid, methanol, ammonium sulfate, and potassium chloride was negligible. The proposed system was applied to the determination of total polyphenols in red wines, and enabled analysis of approximately 55 samples h–1. Results were usually precise and accurate; the RSD was <3.9% and relative errors, by the Folin–Ciocalteu method, <5.1%.
Resumo:
This work shows that the synthesis of protein plastic antibodies tailored with selected charged monomersaround the binding site enhances protein binding. These charged receptor sites are placed over a neutralpolymeric matrix, thus inducing a suitable orientation the protein reception to its site. This is confirmed bypreparing control materials with neutral monomers and also with non-imprinted template. This concepthas been applied here to Prostate Specific Antigen (PSA), the protein of choice for screening prostate can-cer throughout the population, with serum levels >10 ng/mL pointing out a high probability of associatedcancer.Protein Imprinted Materials with charged binding sites (C/PIM) have been produced by surfaceimprinting over graphene layers to which the protein was first covalently attached. Vinylben-zyl(trimethylammonium chloride) and vinyl benzoate were introduced as charged monomers labellingthe binding site and were allowed to self-organize around the protein. The subsequent polymerizationwas made by radical polymerization of vinylbenzene. Neutral PIM (N/PIM) prepared without orientedcharges and non imprinted materials (NIM) obtained without template were used as controls.These materials were used to develop simple and inexpensive potentiometric sensor for PSA. Theywere included as ionophores in plasticized PVC membranes, and tested over electrodes of solid or liq-uid conductive contacts, made of conductive carbon over a syringe or of inner reference solution overmicropipette tips. The electrodes with charged monomers showed a more stable and sensitive response,with an average slope of -44.2 mV/decade and a detection limit of 5.8 × 10−11mol/L (2 ng/mL). The cor-responding non-imprinted sensors showed lower sensitivity, with average slopes of -24.8 mV/decade.The best sensors were successfully applied to the analysis of serum, with recoveries ranging from 96.9to 106.1% and relative errors of 6.8%.
Resumo:
Prostate Specific Antigen (PSA) is the biomarker of choice for screening prostate cancer throughout the population, with PSA values above 10 ng/mL pointing out a high probability of associated cancer1. According to the most recent World Health Organization (WHO) data, prostate cancer is the commonest form of cancer in men in Europe2. Early detection of prostate cancer is thus very important and is currently made by screening PSA in men over 45 years old, combined with other alterations in serum and urine parameters. PSA is a glycoprotein with a molecular mass of approximately 32 kDa consisting of one polypeptide chain, which is produced by the secretory epithelium of human prostate. Currently, the standard methods available for PSA screening are immunoassays like Enzyme-Linked Immunoabsorbent Assay (ELISA). These methods are highly sensitive and specific for the detection of PSA, but they require expensive laboratory facilities and high qualify personal resources. Other highly sensitive and specific methods for the detection of PSA have also become available and are in its majority immunobiosensors1,3-5, relying on antibodies. Less expensive methods producing quicker responses are thus needed, which may be achieved by synthesizing artificial antibodies by means of molecular imprinting techniques. These should also be coupled to simple and low cost devices, such as those of the potentiometric kind, one approach that has been proven successful6. Potentiometric sensors offer the advantage of selectivity and portability for use in point-of-care and have been widely recognized as potential analytical tools in this field. The inherent method is simple, precise, accurate and inexpensive regarding reagent consumption and equipment involved. Thus, this work proposes a new plastic antibody for PSA, designed over the surface of graphene layers extracted from graphite. Charged monomers were used to enable an oriented tailoring of the PSA rebinding sites. Uncharged monomers were used as control. These materials were used as ionophores in conventional solid-contact graphite electrodes. The obtained results showed that the imprinted materials displayed a selective response to PSA. The electrodes with charged monomers showed a more stable and sensitive response, with an average slope of -44.2 mV/decade and a detection limit of 5.8X10-11 mol/L (2 ng/mL). The corresponding non-imprinted sensors showed smaller sensitivity, with average slopes of -24.8 mV/decade. The best sensors were successfully applied to the analysis of serum samples, with percentage recoveries of 106.5% and relatives errors of 6.5%.
Resumo:
The new generations of SRAM-based FPGA (field programmable gate array) devices are the preferred choice for the implementation of reconfigurable computing platforms intended to accelerate processing in real-time systems. However, FPGA's vulnerability to hard and soft errors is a major weakness to robust configurable system design. In this paper, a novel built-in self-healing (BISH) methodology, based on run-time self-reconfiguration, is proposed. A soft microprocessor core implemented in the FPGA is responsible for the management and execution of all the BISH procedures. Fault detection and diagnosis is followed by repairing actions, taking advantage of the dynamic reconfiguration features offered by new FPGA families. Meanwhile, modular redundancy assures that the system still works correctly
Resumo:
O mercado da reabilitação de estruturas em Portugal está em voga, sendo um nicho de mercado com evolução galopante nos últimos anos fruto da consciencialização das entidades responsáveis, assim como das necessidades de intervir no parque edificado cada vez mais degradado, resultando num estímulo para o mercado da construção face ao seu estado atual. As causas associadas à degradação prematura dos materiais estruturais resultam de erros de conceção e execução, assim como do facto de muitas estruturas de betão armado do parque habitacional edificado nas décadas de 60 e 70, estarem a atingir o fim do seu período de vida útil. Na avaliação do estado de degradação de estruturas de betão armado aconselha-se a utilização de ensaios não destrutivos, uma vez que permitem efetuar um diagnóstico com resultados positivos salvaguardando a integridade da estrutura. A norma EN 1504“Produtos e Sistemas para a proteção e reparação de estruturas de betão” estipula os procedimentos de execução, as características dos materiais mais adequados a cada tipo de projeto, assim como a divisão do seu encadeamento em 5 fases. O caso prático apresentado é um edifício de prestação de serviços municipais, tendo sido aplicado com o maior rigor possível as fases de inspeção, diagnóstico, deliberação e reparação. Foi efetuada uma fase de diagnóstico, de carácter visual assim como de caracterização física dos elementos estruturais em betão armado através de ensaios “in situ”. A estrutura avaliada apresenta debilidades e um estado de degradação acelerado, pelo que urge uma intervenção de reparação por forma a repor a estrutura com as características da sua conceção, salvaguardando a segurança das pessoas e bens.
Resumo:
Aprender a ler é um dos maiores desafios que as crianças enfrentam quando entram para a escola. A dificuldade no domínio do código alfabético, nos níveis da consciência fonológica e a falta de fluência na leitura são fatores que interferem em larga escala na aprendizagem global dos alunos. Habilitar um aluno para a prática da leitura é um estímulo que tem vindo a dar origem a várias investigações e intervenções no campo da educação. Este projeto descreve dois programas de treino: “Programa de treino da percepção Visual” e “Programa de promoção do desenvolvimento da consciência fonológica”, num aluno do 2º ciclo do ensino básico com dificuldade de fluência na leitura, ao longo de quinze aulas de 90 minutos. No que respeita aos resultados do primeiro estudo, que teve por base o “Programa de treino da percepção visual”, não foram encontradas diferenças relevantes quanto ao seu efeito na fluência da leitura do aluno. No entanto, no segundo estudo, que se centrou na aplicação do “Programa de promoção do desenvolvimento da consciência fonológica” em complemento com o “Programa de treino da percepção visual”, mostrou que o aluno ficou mais fluente na leitura diminuindo o número de erros de precisão (substituições, omissões, inversões, adições e erros complexos). Assim, sugere-se uma monotorização sistemática das aprendizagens dos alunos para que as intervenções possam ser cada vez mais precoces e direcionadas para as suas necessidades.