165 resultados para Electrical energy consumption
em Instituto Politécnico do Porto, Portugal
Resumo:
In competitive electricity markets with deep concerns for the efficiency level, demand response programs gain considerable significance. As demand response levels have decreased after the introduction of competition in the power industry, new approaches are required to take full advantage of demand response opportunities. This paper presents DemSi, a demand response simulator that allows studying demand response actions and schemes in distribution networks. It undertakes the technical validation of the solution using realistic network simulation based on PSCAD. The use of DemSi by a retailer in a situation of energy shortage, is presented. Load reduction is obtained using a consumer based price elasticity approach supported by real time pricing. Non-linear programming is used to maximize the retailer’s profit, determining the optimal solution for each envisaged load reduction. The solution determines the price variations considering two different approaches, price variations determined for each individual consumer or for each consumer type, allowing to prove that the approach used does not significantly influence the retailer’s profit. The paper presents a case study in a 33 bus distribution network with 5 distinct consumer types. The obtained results and conclusions show the adequacy of the used methodology and its importance for supporting retailers’ decision making.
Resumo:
This study is based on a previous experimental work in which embedded cylindrical heaters were applied to a pultrusion machine die, and resultant energetic performance compared with that achieved with the former heating system based on planar resistances. The previous work allowed to conclude that the use of embedded resistances enhances significantly the energetic performance of pultrusion process, leading to 57% decrease of energy consumption. However, the aforementioned study was developed with basis on an existing pultrusion die, which only allowed a single relative position for the heaters. In the present work, new relative positions for the heaters were investigated in order to optimise heat distribution process and energy consumption. Finite Elements Analysis was applied as an efficient tool to identify the best relative position of the heaters into the die, taking into account the usual parameters involved in the process and the control system already tested in the previous study. The analysis was firstly developed based on eight cylindrical heaters located in four different location plans. In a second phase, in order to refine the results, a new approach was adopted using sixteen heaters with the same total power. Final results allow to conclude that the correct positioning of the heaters can contribute to about 10% of energy consumption reduction, decreasing the production costs and leading to a better eco-efficiency of pultrusion process.
Resumo:
The global warming due to high CO2 emission in the last years has made energy saving a global problem nowadays. However, manufacturing processes such as pultrusion necessarily needs heat for curing the resin. Then, the only option available is to apply all efforts to make the process even more efficient. Different heating systems have been used on pultrusion, however, the most widely used are the planar resistances. The main objective of this study is to develop another heating system and compares it with the former one. Thermography was used in spite of define the temperature profile along the die. FEA (finite element analysis) allows to understand how many energy is spend with the initial heating system. After this first approach, changes were done on the die in order to test the new heating system and to check possible quality problems on the product. Thus, this work allows to conclude that with the new heating system a significant reduction in the setup time is now possible and an energy reduction of about 57% was achieved.
Resumo:
The recent changes on power systems paradigm requires the active participation of small and medium players in energy management. With an electricity price fluctuation these players must manage the consumption. Lowering costs and ensuring adequate user comfort levels. Demand response can improve the power system management and bring benefits for the small and medium players. The work presented in this paper, which is developed aiming the smart grid context, can also be used in the current power system paradigm. The proposed system is the combination of several fields of research, namely multi-agent systems and artificial neural networks. This system is physically implemented in our laboratories and it is used daily by researchers. The physical implementation gives the system an improvement in the proof of concept, distancing itself from the conventional systems. This paper presents a case study illustrating the simulation of real-time pricing in a laboratory.
Resumo:
Indoor Air 2016 - The 14th International Conference of Indoor Air Quality and Climate
Resumo:
Um dos princípios da Gestão é: “If you cannot measure it, you cannot improve it.” In The Economist – 26.Dez.2008, idea of 19th century English physicist Lord Kelvin. Embora seja uma afirmação aplicável à gestão económica, também pode ser utilizada no domínio da gestão da energia. Este trabalho surge da necessidade sentida pela empresa Continental - Industria Têxtil do Ave, S.A. em efetuar uma atualização dos seus standards de produção, minimizando os seus consumos de eletricidade e gás natural. Foi necessário efetuar o levantamento dos consumos em diversas máquinas e equipamentos industriais, caracterizando e analisando os consumos ao longo de todo o processo produtivo. Para o tratamento de dados recolhidos foi desenvolvida uma folha de cálculo em MS Office ExcelTM com metodologia adequada ao equipamento em análise, que dará apoio ao decisor para a identificação dos aspetos que melhorem o processo produtivo e garantam uma elevada eficiência energética. Porém, não se enquadra no âmbito do Plano Nacional de Racionalização de Energia, sendo uma “auditoria energética” ao processo produtivo. Recentemente, a empresa, tem vindo a utilizar equipamentos eletrónicos que permitem otimizar o funcionamento mecânico dos equipamentos e das potências instaladas dos transformadores, na tentativa de racionalizar o consumo da energia elétrica. Outros equipamentos como, conversores de frequência para controlo de motores, balastros eletrónicos que substituem os convencionais balastros ferromagnéticos das lâmpadas de descarga fluorescente, têm sido incluídos ao nível das instalações elétricas, sendo gradualmente substituída a eletromecânica pela eletrónica. Este tipo de soluções vem deteriorar as formas de onda da corrente e da tensão do sistema pela introdução de distorções harmónicas. Faz ainda parte deste trabalho, um estudo de uma solução que melhore, simultaneamente o fator de potência e reduza as harmónicas presentes num posto de transformação localizado no seio da fábrica. Esta solução, permite melhorar a qualidade da energia elétrica e as condições de continuidade de serviço, garantindo melhores condições de exploração e incrementando a produtividade da empresa.
Resumo:
O consumo de energia de forma irracional acarreta desvantagens a nível económico para o consumidor e problemas ambientais para toda a sociedade, como a escassez de recursos naturais e o aumento da poluição. Neste contexto, a otimização energética na indústria, e em particular no setor das borrachas, é indispensável de forma a utilizar racionalmente a energia e assim contribuir para a viabilidade das empresas. Este trabalho, efetuado na Flexocol - Fábrica de Artefactos de Borracha, Lda., teve como principal objetivo efetuar um levantamento energético à unidade fabril e propor alternativas que permitissem a redução do consumo de energia elétrica. Foi ainda realizado um estudo sobre a possibilidade de substituir o n-hexano, solvente utilizado na limpeza dos moldes, por um solvente mais adequado. O levantamento energético efetuado permitiu identificar o consumo das utilidades existentes na Flexocol. Esta empresa consome gasóleo e energia elétrica, sendo esta última, a forma de energia mais consumida correspondendo a 96%. O consumo global de energia é cerca 151 tep anuais, inferior a 500 tep/ano, ou seja é considerada uma empresa não consumidora intensiva de energia. Com base neste levantamento determinou-se os indicadores de consumo específico de energia e da intensidade carbónica, 2,73 tep/ ton e 1684,5 kg CO2/tep. A análise do consumo de energia elétrica dos diferentes equipamentos permitiu verificar que o setor que mais consome energia elétrica é a Vulcanização com 45,8%, seguido do setor da Mistura e Serralharia com 27,5% e 26,7%, respetivamente. O sistema de iluminação nos vários setores foi também alvo de estudo e permitiu identificar a Vulcanização como o setor com mais consumo e o da Mistura como o que menos consome. O estudo das variáveis anteriormente referidas permitiu apresentar algumas propostas de melhoria. Uma das propostas analisada foi implementação de condensadores no quadro parcial de forma a diminuir a energia reativa. Com esta medida prevê-se uma poupança de 5631 €/ano e um retorno de investimento de 0,045 anos. Foi também analisada relativamente à iluminação a possibilidade de instalação de balastros eletrónicos que conduziria a uma poupança na energia elétrica de cerca 7072 kWh/ano, mas com um retorno de investimento desfavorável. Por último estudou-se o solvente alternativo ao n-hexano. A acetona foi o solvente proposto uma vez que tem as propriedades indicadas para o fim a que se destina.
Resumo:
Power systems have been through deep changes in recent years, namely with the operation of competitive electricity markets in the scope and the increasingly intensive use of renewable energy sources and distributed generation. This requires new business models able to cope with the new opportunities that have emerged. Virtual Power Players (VPPs) are a new player type which allows aggregating a diversity of players (Distributed Generation (DG), Storage Agents (SA), Electrical Vehicles, (V2G) and consumers), to facilitate their participation in the electricity markets and to provide a set of new services promoting generation and consumption efficiency, while improving players` benefits. A major task of VPPs is the remuneration of generation and services (maintenance, market operation costs and energy reserves), as well as charging energy consumption. This paper proposes a model to implement fair and strategic remuneration and tariff methodologies, able to allow efficient VPP operation and VPP goals accomplishment in the scope of electricity markets.
Resumo:
Designing electric installation projects, demands not only academic knowledge, but also other types of knowledge not easily acquired through traditional instructional methodologies. A lot of additional empirical knowledge is missing and so the academic instruction must be completed with different kinds of knowledge, such as real-life practical examples and simulations. On the other hand, the practical knowledge detained by the most experienced designers is not formalized in such a way that is easily transmitted. In order to overcome these difficulties present in the engineers formation, we are developing an Intelligent Tutoring System (ITS), for training and support concerning the development of electrical installation projects to be used by electrical engineers, technicians and students.
Resumo:
Ensuring sustainable development conditions is presently world widely recognized as a critically important goal. This makes the use of electricity generation technologies based on renewable energy sources very relevant. Developing countries depend on an adequate availability of electrical energy to assure economic progress and are usually characterized by a high increase in electricity consumption. This makes sustainable development a huge challenge but it can also be taken as an opportunity, especially for countries which do not have fossil resources. This paper presents a study concerning the expansion of an already existent wind farm, located in Praia, the capital of Cape Verde Republic. The paper includes results from simulation studies that have been undertaken using PSCAD software and some economic considerations.
Resumo:
Distributed generation unlike centralized electrical generation aims to generate electrical energy on small scale as near as possible to load centers, interchanging electric power with the network. This work presents a probabilistic methodology conceived to assist the electric system planning engineers in the selection of the distributed generation location, taking into account the hourly load changes or the daily load cycle. The hourly load centers, for each of the different hourly load scenarios, are calculated deterministically. These location points, properly weighted according to their load magnitude, are used to calculate the best fit probability distribution. This distribution is used to determine the maximum likelihood perimeter of the area where each source distributed generation point should preferably be located by the planning engineers. This takes into account, for example, the availability and the cost of the land lots, which are factors of special relevance in urban areas, as well as several obstacles important for the final selection of the candidates of the distributed generation points. The proposed methodology has been applied to a real case, assuming three different bivariate probability distributions: the Gaussian distribution, a bivariate version of Freund’s exponential distribution and the Weibull probability distribution. The methodology algorithm has been programmed in MATLAB. Results are presented and discussed for the application of the methodology to a realistic case and demonstrate the ability of the proposed methodology for efficiently handling the determination of the best location of the distributed generation and their corresponding distribution networks.
Resumo:
Cada vez mais a indústria tem vindo a sofrer algumas mudanças no seu processo produtivo. Hoje, mais que nunca, é preciso garantir que as instalações produtivas sejam o mais eficiente possível, procurando a racionalização de energia com um decrescimento dos custos. Deste modo o objectivo desta dissertação é o diagnóstico energético da fábrica de placas de borracha e a optimização do sector da pintura na empresa Monteiro Ribas. A realização de um diagnóstico energético, para a detecção de desperdícios de energia tem sido amplamente utilizada. A optimização irá prospectar potenciais de mudanças e aplicação de tecnologias de eficiência energética. Pretende-se deste modo travar o consumo energético sem que seja afectada a produção, já que a empresa é considerada consumidora intensiva de energia. Na empresa Monteiro Ribas há consumo de gás natural, de vapor e de energia eléctrica, sendo o vapor a forma de energia mais consumida, seguida da energia eléctrica e por fim, do gás natural nas proporções de 55%, 41% e 4%, respectivamente. A optimização feita permitiu estudar a influência de algumas variáveis, nos consumos anuais da energia, e assim apresentar propostas de melhoria. Uma das propostas analisadas foi a possibilidade de efectuar um isolamento térmico a algumas válvulas. Este isolamento conduziria a uma poupança de 79.263,4 kWh/ano. Propôs-se também a implementação de balastros electrónicos, que conduziria a uma diminuição em energia eléctrica de 29.509,92 kWh/ano. Relativamente às máquinas utilizadas no sector da pintura, verificou-se ser a estufa IRK 6, um dos equipamentos de grande consumo energético. Então analisou-se a influência da velocidade de circulação das placas de borracha através desta máquina, bem como a alteração da respectiva potência, pela diminuição do número de cassetes incorporados nesta estufa.
Resumo:
Este trabalho teve como propósito fazer uma avaliação do desempenho energético e da qualidade do ar no interior das instalações de uma Piscina Municipal Coberta, localizada na zona norte de Portugal, sendo estabelecidos os seguintes objetivos: caracterização geral da piscina, no que respeita aos seus diferentes espaços e equipamentos, cálculo dos consumos térmicos e elétricos bem como o registo das concentrações de elementos poluentes para controlo da qualidade do ar no interior da piscina, tendo como base a legislação atualmente em vigor. A caracterização geral da piscina permitiu verificar algumas inconformidades como a temperatura da água nos tanques de natação que tem valores superiores aos recomendados e a sala de primeiros socorros que não possui acesso direto ao exterior. Acrescente-se que o pavimento nos chuveiros da casa de banho feminina e os valores de pH para água do tanque grande e pequeno não estão sempre dentro da gama de recomendação. O caudal da renovação de ar está a ser operado manualmente e quando está a funcionar a 50% da sua capacidade máxima, que acontece numa parte do dia, apenas consegue renovar 77,5% do caudal recomendado pelo RSECE. Para se obter o valor recomendado é necessário ter pelo menos 7 horas com o caudal a 100% da capacidade máxima. A avaria na UTA2 originou que 40% dos registos diários da humidade relativa interior estivessem fora da gama de valores recomendados e que esta é fortemente dependente da humidade no exterior e pode ser agravada quando as portas dos envidraçados da nave são abertas. Analisando ainda a quantidade de água removida na desumidificação do ar com a água evaporada em condições de Outono-Inverno ou Primavera-Verão, este estudo permitiu concluir que todas as combinações demonstraram a necessidade de desumidificação salvo a combinação Outono-Inverno e UTA2 a funcionar a 100% da sua capacidade máxima. Os isolamentos das tubagens na sala das caldeiras foram observados e comparados com as soluções recomendadas pelas empresas especialistas e verificou-se que alguns estão mal colocados com parcial ou total degradação, promovendo perdas térmicas. No caso das perdas calorificas por evaporação, estas representaram cerca de 67,78% das perdas totais. Como tal, estudou-se a aplicação de uma cobertura sobre o plano de água durante o período de inatividade da piscina (8 horas) e verificou-se que o resultado seria uma poupança de 654,8 kWh/dia, na ausência de evaporação da água, mais 88,00 kWh/dia do período da UTA2 a funcionar a 50% da sua capacidade, perfazendo um total de 742,8 kWh/dia. A aplicação da cobertura permite obter um VAL de valor positivo, uma TIR de 22,77% e sendo este valor superior ao WACC (Weight Average Cost of Capital), o projeto torna-se viável com um Pay-Back de 3,17 anos. Caracterizou-se também o consumo total diário em eletricidade, e verificou-se que as unidades de climatização, as bombas de circulação de água, a iluminação, e outros equipamentos representam, respetivamente, cerca de 67,81, 25,26, 2,68 e 3,91% da energia elétrica total consumida. Por fim, a análise à qualidade do ar no interior da nave em Maio e Setembro identificou que as concentrações de ozono apresentavam valores no limite do aceitável em Maio e superiores ao valor de emissão em Setembro. Os compostos orgânicos voláteis também apresentavam valores em Maio 4,98 vezes superior e em Setembro 6,87 vezes superior aos valores máximos exigidos pelo D.L. nº 79/2006. Houve ainda altas concentrações de radão registadas na casa dos filtros, em Maio com um valor 11,49 vezes superior, no entanto esse valor desceu em Setembro para 1,08 vezes, mesmo assim superior ao exigido pelo D.L. nº 79/2006.
Resumo:
For the past years wireless sensor networks (WSNs) have been coined as one of the most promising technologies for supporting a wide range of applications. However, outside the research community, few are the people who know what they are and what they can offer. Even fewer are the ones that have seen these networks used in real world applications. The main obstacle for the proliferation of these networks is energy, or the lack of it. Even though renewable energy sources are always present in the networks environment, designing devices that can efficiently scavenge that energy in order to sustain the operation of these networks is still an open challenge. Energy scavenging, along with energy efficiency and energy conservation, are the current available means to sustain the operation of these networks, and can all be framed within the broader concept of “Energetic Sustainability”. A comprehensive study of the several issues related to the energetic sustainability of WSNs is presented in this thesis, with a special focus in today’s applicable energy harvesting techniques and devices, and in the energy consumption of commercially available WSN hardware platforms. This work allows the understanding of the different energy concepts involving WSNs and the evaluation of the presented energy harvesting techniques for sustaining wireless sensor nodes. This survey is supported by a novel experimental analysis of the energy consumption of the most widespread commercially available WSN hardware platforms.
Resumo:
O presente relatório descreve o trabalho de estágio efectuado na empresa Curtumes Aveneda, Lda com o objectivo de optimizar recursos como a água e energia. Foi realizado um diagnóstico energético que permitiu concluir que o consumo de energia na empresa é de 300 tep/ano, pelo que a empresa não é obrigada a adoptar as medidas de Regulamento de Gestão do Consumo de Energia (RGCE). O mesmo diagnóstico aponta para a existência de ineficiências, nomeadamente na tinturaria. Assim, foi projectado um sistema de controlo para adição de água na tinturaria com o intuito de reduzir o consumo de energia e água, e também melhorar a qualidade dos processos de tinturaria, dado que a adição de água é feita manualmente sem controlo de quantidade. Após consulta de fornecedor, o investimento em equipamento para tal sistema é de 10.012,00€ Foi desenvolvido um processo de recurtume compacto no sentido de promover a redução do consumo de água e de energia. Tal processo, quando comparado com um processo normal da empresa, gera uma redução de energia eléctrica no valor de 6.157,05 €/ano, uma redução no consumo de energia térmica da ordem de 904,00 €/ano, e ainda uma redução do consumo de água na ordem de 962 m3/ano correspondente a uma redução de 2.998,76 €/ano no tratamento de efluentes. Outras medidas foram sugeridas, mas sem uma fundamentação técnica e científica suficiente pelo que carecem de um estudo pormenorizado, como a instalação de arrancadores progressivos nos motores dos fulões, a optimização do aquecimento do ar de secagem na estufa com eventual recurso a painéis solares, e a optimização do funcionamento da caldeira dado o seu baixo rendimento.