61 resultados para Antimicrobial substancies detection

em Instituto Politécnico do Porto, Portugal


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel optical disposable probe for screening fluoroquinolones in fish farming waters is presented, having Norfloxacin (NFX) as target compound. The colorimetric reaction takes place in the solid/liquid interface consisting of a plasticized PVC layer carrying the colorimetric reagent and the sample solution. NFX solutions dropped on top of this solid-sensory surface provided a colour change from light yellow to dark orange. Several metals were tested as colorimetric reagents and Fe(III) was selected. The main parameters affecting the obtained colour were assessed and optimised in both liquid and solid phases. The corresponding studies were conducted by visible spectrophotometry and digital image acquisition. The three coordinates of the HSL model system of the collected image (Hue, Saturation and Lightness) were obtained by simple image management (enabled in any computer). The analytical response of the optimised solid-state optical probe against concentration was tested for several mathematical transformations of the colour coordinates. Linear behaviour was observed for logarithm NFX concentration against Hue+Lightness. Under this condition, the sensor exhibited a limit of detection below 50 μM (corresponding to about 16 mg/mL). Visual inspection also enabled semi-quantitative information. The selectivity was ensured against drugs from other chemical groups than fluoroquinolones. Finally, similar procedure was used to prepare an array of sensors for NFX, consisting on different metal species. Cu(II), Mn(II) and aluminon were selected for this purpose. The sensor array was used to detect NFX in aquaculture water, without any prior sample manipulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A água é um recurso escasso e indispensável à vida, podendo ser um importante veículo de microrganismos patogénicos com origem fecal. A matéria fecal é também uma fonte de microrganismos resistentes a antimicrobianos e contribui para a sua disseminação e dos seus genes de resistência no ambiente e entre as comunidades microbianas comensais e microrganismos patogénicos humanos e animais. A qualidade microbiológica da água é monitorizada recorrendo à utilização de bioindicadores como Escherichia coli, enterococos e microrganismos totais. O presente estudo apresentou como principal objetivo determinar a prevalência de ESBLs e AmpCs e ainda avaliar a prevalência de estirpes de enterococos com resistência à vancomicina (VRE) em águas do rio Douro e da orla costeira da cidade do Porto. As amostragens de água foram realizadas em quatro locais localizados no estuário do rio Douro e orla costeira da cidade do Porto entre o mês de Abril e Julho. A deteção e quantificação dos bioindicadores foram realizadas pelo método de filtração por membrana. A suscetibilidade das estirpes de E. coli e enterococos foi testada pelo método de difusão em disco relativamente a várias classes de antimicrobianos. As contagens microbianas mais elevadas foram determinadas entre Abril e Junho e em amostras de água doce. Foram isoladas 62 estirpes de E. coli e 49 estirpes de enterococos que apresentaram prevalências de resistência a antimicrobianos de 90,3% (56/62) e 83,7% (41/49), respetivamente. As estirpes de E. coli apresentaram altas frequências de resistência à ampicilina (74,2%) e tetraciclina (61,3%). Nestas estirpes verificou-se ainda fenótipos associados a multirresistência a um mínimo de três classes de antimicrobianos em 56,5% (35/62) dos isolados. Verificou-se que as estirpes de enterococos apresentaram altos níveis de resistência à rifampicina (34,7%) e azitromicina (40,8%), detetando-se ainda a manifestação de fenótipo de resistência à vancomicina em 26,5% das estirpes. Observou-se uma prevalência de 36,7% (18/49) de estirpes de enterococos associadas a fenómenos de multirresistência antimicrobiana. Ana Martins vi Os resultados obtidos sugerem que o rio Douro e orla costeira, bem como os ambientes aquáticos, constituem reservatórios de bactérias e genes de resistência a antimicrobianos e possuem um papel preponderante na sua disseminação.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A emergência de multiresistência apresentada por microrganismos é um dos grandes desafios que enfrentam actualmente os profissionais de Saúde e a população em geral. Os factores que contribuem para o desenvolvimento de resistência a antibióticos na comunidade podem ser categorizados como comportamentais ou ambientais/políticas. O objectivo deste trabalho foi caracterizar a situação actual na visão dos Pais de alunos do pré-escolar e 1º ciclo. De modo a avaliar as necessidades de intervenção e as actividades a serem desenvolvidas, um instrumento para estudar os hábitos e comportamentos adoptados na utilização de antibióticos, foi adaptado, validado e aplicado numa amostra piloto.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho descreve o estudo da actividad e antimicrobiana de quarto derivados da quinoxalina N,N-dióxido: quinoxalina 1,4-dióxido, 2-metilquinoxalina 1,4- dióxido, 6-cloro-2,3-dimetilquinoxalina 1,4-dióxido e 3-benzoil-2-metilquinoxalina 1,4- dióxido contra as estirpes bacterianas Geobacillus stearothermophilus ATCC 10149, Escherichia coli ATCC 25922, Escherichia coli HB101, Escherichia coli (blaTEM, blaCTX-M) e Salmonella (blaCTX-M), assim como contra a estirpe de levedura Saccharomyces cerevisiae PYCC 4072. A determinação da concentração mínima inibitória (MIC) foi realizada pelo método de diluição. Os valores de MIC’s foram estimados para cada composto e estirpe. Os resultados obtidos sugerem potenciais novas drogas para quimioterapia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aqueous extracts and organic solvent extracts of isolated marine cyanobacteria strains were tested for antimicrobial activity against a fungus, Gram-positive and Gram-negative bacteria and for cytotoxic activity against primary rat hepatocytes and HL-60 cells. Antimicrobial activity was based on the agar diffusion assay. Cytotoxic activity was measured by apoptotic cell death scored by cell surface evaluation and nuclear morphology. A high percentage of apoptotic cells were observed for HL-60 cells when treated with cyanobacterial organic extracts. Slight apoptotic effects were observed in primary rat hepatocytes when exposed to aqueous cyanobacterial extracts. Nine cyanobacteria strains were found to have antibiotic activity against two Gram-positive bacteria, Clavibacter michiganensis subsp. insidiosum and Cellulomonas uda. No inhibitory effects were found against the fungus Candida albicans and Gram-negative bacteria. Marine Synechocystis and Synechococcus extracts induce apoptosis in eukaryotic cells and cause inhibition of Gram-positive bacteria. The different activity in different extracts suggests different compounds with different polarities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The nitrogen heterocyclic organic compounds 1,4 dioxide pyrazine and quinoxaline derivatives have been widely studied due to their potential use as synthetic drugs. The thermochemical study of three N,N´-dioxides: 2,3,5-trimethylpyrazine-1,4-dioxide, tetramethylpyrazine-1,4-dioxide and 6-chloro-2,3-dimethilquinoxaline 1,4-dioxide has been recently developed in order to establish relationships among the energetical, structural and reactivity properties [4,5]. Several studies have reported their pharmacological activity, particularly as antimicrobial agents [1,2,3]. It has also been established a relation between energetical and structural properties and biological activity, once these compounds present N – oxide bonds, increasing their oxidative capacity. The present work reports the study of antimicrobial activity for those compounds against the bacteria Geobacillus stearothermophylus, Staphylococcus aureus, Streptococcus agalactiae, Escherichia coli and also against the yeasts Saccharomyces cerevisiae PYCC 4072, Candida albicans PYCC3436T, Candida tropicalis PYCC, Issatchenka Orientalis PYCC. The determination of the minimal inhibitory concentration (MIC), points to an antimicrobial activity and the preliminary results indicate that these compounds may be potential candidates as antimicrobial drugs with clinical, agriculture or food industries applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Celiac disease is a gluten-induced autoimmune enteropathy characterized by the presence of tissue tranglutaminase (tTG) autoantibodies. A disposable electrochemical immunosensor (EI) for the detection of IgA and IgG type anti-tTG autoantibodies in real patient’s samples is presented. Screen-printed carbon electrodes (SPCE) nanostructurized with carbon nanotubes and gold nanoparticles were used as the transducer surface. This transducer exhibits the excellent characteristics of carbon–metal nanoparticle hybrid conjugation and led to the amplification of the immunological interaction. The immunosensing strategy consisted of the immobilization of tTG on the nanostructured electrode surface followed by the electrochemical detection of the autoantibodies present in the samples using an alkaline phosphatase (AP) labelled anti-human IgA or IgG antibody. The analytical signal was based on the anodic redissolution of enzymatically generated silver by cyclic voltammetry. The results obtained were corroborated with a commercial ELISA kit indicating that the electrochemical immunosensor is a trustful analytical screening tool.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The relentless discovery of cancer biomarkers demands improved methods for their detection. In this work, we developed protein imprinted polymer on three-dimensional gold nanoelectrode ensemble (GNEE) to detect epithelial ovarian cancer antigen-125 (CA 125), a protein biomarker associated with ovarian cancer. CA 125 is the standard tumor marker used to follow women during or after treatment for epithelial ovarian cancer. The template protein CA 125 was initially incorporated into the thin-film coating and, upon extraction of protein from the accessible surfaces on the thin film, imprints for CA 125 were formed. The fabrication and analysis of the CA 125 imprinted GNEE was done by using cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS) techniques. The surfaces of the very thin, protein imprinted sites on GNEE are utilized for immunospecific capture of CA 125 molecules, and the mass of bound on the electrode surface can be detected as a reduction in the faradic current from the redox marker. Under optimal conditions, the developed sensor showed good increments at the studied concentration range of 0.5–400 U mL−1. The lowest detection limit was found to be 0.5 U mL−1. Spiked human blood serum and unknown real serum samples were analyzed. The presence of non-specific proteins in the serum did not significantly affect the sensitivity of our assay. Molecular imprinting using synthetic polymers and nanomaterials provides an alternative approach to the trace detection of biomarker proteins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mucin-16 (MUC16) is the established ovarian cancer marker used to follow the disease during or after treatment for epithelial ovarian cancer. The emerging science of cancer markers also demands for the new sensitive detection methods. In this work, we have developed an electrochemical immunosensor for antigen MUC16 using gold nanoelectrode ensemble (GNEE) and ferrocene carboxylic acid encapsulated liposomes tethered with monoclonal anti-Mucin-16 antibodies ( MUC16). GNEEs were fabricated by electroless deposition of the gold within the pores of polycarbonate track-etched membranes. Afterwards, MUC16 were immobilized on preformed self-assembled monolayer of cysteamine on the GNEE via cross-linking with EDC-Sulfo-NHS. A sandwich immunoassay was performed on MUC16 functionalized GNEE with MUC16 and immunoliposomes. The differential pulse voltammetry was employed to quantify the faradic redox response of ferrocene carboxylic acid released from immunoliposomes. The dose–response curve for MUC16 concentration was found between the range of 0.001–300 U mL−1. The lowest detection limit was found to be 5 × 10−4 U mL−1 (S/N = 3). We evaluated the performance of this developed immunosensor with commercial ELISA assay by comparing results obtained from spiked serum samples and real blood serum samples from volunteers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bacterial food poisoning is an ever-present threat that can be prevented with proper care and handling of food products. A disposable electrochemical immunosensor for the simultaneous measurements of common food pathogenic bacteria namely Escherichia coli O157:H7 (E. coli), campylobacter and salmonella were developed. The immunosensor was fabricated by immobilizing the mixture of anti-E. coli, anticampylobacter and anti-salmonella antibodies with a ratio of 1:1:1 on the surface of the multiwall carbon nanotube-polyallylamine modified screen printed electrode (MWCNT-PAH/SPE). Bacteria suspension became attached to the immobilized antibodies when the immunosensor was incubated in liquid samples. The sandwich immunoassay was performed with three antibodies conjugated with specific nanocrystal ( -E. coli-CdS, -campylobacter-PbS and -salmonella-CuS) which has releasable metal ions for electrochemical measurements. The square wave anodic stripping voltammetry (SWASV) was employed to measure released metal ions from bound antibody nanocrystal conjugates. The calibration curves for three selected bacteria were found in the range of 1 × 103 – 5 × 105 cells mL−1 with the limit of detection (LOD) 400 cells mL−1 for salmonella, 400 cells mL−1 for campylobacter and 800 cells mL−1 for E. coli. The precision and sensitivity of this method show the feasibility of multiplexed determination of bacteria in milk samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of a FIA system for the determination of total choline content in several types of milk is described. The samples were submitted to hydrochloric acid digestion before injection into the system and passed through an enzymatic reactor containing choline oxidase immobilised on glass beads. This enzymatic reaction releases hydrogen peroxide which then reacts with a solution of iodide. The decrease in the concentration of iodide ion is quantified using an iodide ion selective tubular electrode based on a homogeneous crystalline membrane. Validation of the results obtained with this system was performed by comparison with results from a method described in the literature and applied to the determination of total choline in milks. The relative deviation was always < 5%. The repeatability of the method developed was assessed by calculation of the relative standard deviation (RSD) for 12 consecutive injections of one sample. The RSD obtained was < 0.6%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The deterioration of water quality by Cyanobacteria cause outbreaks and epidemics associated with harmful diseases in Humans and animals because of the toxins that they release. Microcystin-LR is one of the hepatotoxins most widely studied and the World Health Organization, recommend a maximum value of 1mgL 1 in drinking water. Highly specific recognition molecules, such as molecular imprinted polymers are developed to quantify microcystins in waters for human use and shown to be of great potential in the analysis of these kinds of samples. The obtained results were auspicious, the detection limit found, 1.5mgL 1, being of the same order of magnitude as the guideline limit recommended by the WHO. This technology is very promising because the sensors are stable and specific, and the technology is inexpensive and allows for rapid on-site monitoring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A multiresidue approach using microwave-assisted extraction and liquid chromatography with photodiode array detection was investigated for the determination of butylate, carbaryl, carbofuran, chlorpropham, ethiofencarb, linuron,metobromuron, and monolinuron in soils. The critical parameters of the developed methodology were studied. Method validation was performed by analyzing freshly and aged spiked soil samples. The recoveries and relative standard deviations reached using the optimized conditions were between 77.0 ± 0.46% and 120 ± 2.9% except for ethiofencarb (46.4 ± 4.4% to 105 ± 1.6%) and butylate (22.1 ± 7.6% to 49.2 ± 11%). Soil samples from five locations of Portugal were analysed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electroanalytical methods based on square-wave adsorptive-stripping voltammetry (SWAdSV) and flow-injection analysis with square-wave adsorptive-stripping voltammetric detection (FIA-SWAdSV) were developed for the determination of fluoxetine (FXT). The methods were based on the reduction of FXT at a mercury drop electrode at -1.2 V versus Ag/AgCl, in a phosphate buffer of pH 12.0, and on the possibility of accumulating the compound at the electrode surface. The SWAdSV method was successfully applied in the quantification of FXT in pharmaceutical products, human serum samples, and in drug dissolution studies. Because the presence of dissolved oxygen did not interfere significantly with the analysis, it was possible to quantify FXT in several pharmaceutical products using FIA-SWAdSV. This method enables analysis of up to 120 samples per hour at reduced costs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

On the basis of its electrochemical behaviour a new flow-injection analysis (FIA) method with amperometric detection has been developed for quantification of the herbicide bentazone (BTZ) in estuarine waters. Standard solutions and samples (200 µL) were injected into a water carrier stream and both pH and ionic strength were automatically adjusted inside the manifold. Optimization of critical FIA conditions indicated that the best analytical results were obtained at an oxidation potential of 1.10 V, pH 4.5, and an overall flow-rate of 2.4 mL min–1. Analysis of real samples was performed by means of calibration curves over the concentration range 2.5x10–6 to 5.0x10–5 mol L–1, and results were compared with those obtained by use of an independent method (HPLC). The accuracy of the amperometric determinations was ascertained; errors relative to the comparison method were below 4% and sampling rates were approximately 100 samples h–1. The repeatability of the proposed method was calculated by assessing the relative standard deviation (%) of ten consecutive determinations of one sample; the value obtained was 2.1%.