126 resultados para Fernanda Montenegro


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Potentiometric sensors are typically unable to carry out on-site monitoring of environmental drug contaminants because of their high limits of detection (LODs). Designing a novel ligand material for the target analyte and managing the composition of the internal reference solution have been the strategies employed here to produce for the first time a potentiometric-based direct reading method for an environmental drug contaminant. This concept has been applied to sulfamethoxazole (SMX), one of the many antibiotics used in aquaculture practices that may occur in environmental waters. The novel ligand has been produced by imprinting SMX on the surface of graphitic carbon nanostructures (CN) < 500 nm. The imprinted carbon nanostructures (ICN) were dispersed in plasticizer and entrapped in a PVC matrix that included (or not) a small amount of a lipophilic additive. The membrane composition was optimized on solid-contact electrodes, allowing near-Nernstian responses down to 5.2 μg/mL and detecting 1.6 μg/mL. The membranes offered good selectivity against most of the ionic compounds in environmental water. The best membrane cocktail was applied on the smaller end of a 1000 μL micropipette tip made of polypropylene. The tip was then filled with inner reference solution containing SMX and chlorate (as interfering compound). The corresponding concentrations were studied for 1 × 10−5 to 1 × 10−10 and 1 × 10−3 to 1 × 10−8 mol/L. The best condition allowed the detection of 5.92 ng/L (or 2.3 × 10−8 mol/L) SMX for a sub-Nernstian slope of −40.3 mV/decade from 5.0 × 10−8 to 2.4 × 10−5 mol/L.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sulfamethoxazole (SMX) is among the antibiotics employed in aquaculture for prophylactic and therapeutic reasons. Environmental and food spread may be prevented by controlling its levels in several stages of fish farming. The present work proposes for this purpose new SMX selective electrodes for the potentiometric determination of this sulphonamide in water. The selective membranes were made of polyvinyl chloride (PVC) with tetraphenylporphyrin manganese (III) chloride or cyclodextrin-based acting as ionophores. 2-nitrophenyl octyl ether was employed as plasticizer and tetraoctylammonium, dimethyldioctadecylammonium bromide or potassium tetrakis (4-chlorophenyl) borate was used as anionic or cationic additive. The best analytical performance was reported for ISEs of tetraphenylporphyrin manganese (III) chloride with 50% mol of potassium tetrakis (4-chlorophenyl) borate compared to ionophore. Nersntian behaviour was observed from 4.0 × 10−5 to 1.0 × 10−2 mol/L (10.0 to 2500 µg/mL), and the limit of detection was 1.2 × 10−5 mol/L (3.0 µg/mL). In general, the electrodes displayed steady potentials in the pH range of 6 to 9. Emf equilibrium was reached before 15 s in all concentration levels. The electrodes revealed good discriminating ability in environmental samples. The analytical application to contaminated waters showed recoveries from 96 to 106%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Monitoring organic environmental contaminants is of crucial importance to ensure public health. This requires simple, portable and robust devices to carry out on-site analysis. For this purpose, a low-temperature co-fired ceramics (LTCC) microfluidic potentiometric device (LTCC/μPOT) was developed for the first time for an organic compound: sulfamethoxazole (SMX). Sensory materials relied on newly designed plastic antibodies. Sol–gel, self-assembling monolayer and molecular-imprinting techniques were merged for this purpose. Silica beads were amine-modified and linked to SMX via glutaraldehyde modification. Condensation polymerization was conducted around SMX to fill the vacant spaces. SMX was removed after, leaving behind imprinted sites of complementary shape. The obtained particles were used as ionophores in plasticized PVC membranes. The most suitable membrane composition was selected in steady-state assays. Its suitability to flow analysis was verified in flow-injection studies with regular tubular electrodes. The LTCC/μPOT device integrated a bidimensional mixer, an embedded reference electrode based on Ag/AgCl and an Ag-based contact screen-printed under a micromachined cavity of 600 μm depth. The sensing membranes were deposited over this contact and acted as indicating electrodes. Under optimum conditions, the SMX sensor displayed slopes of about −58.7 mV/decade in a range from 12.7 to 250 μg/mL, providing a detection limit of 3.85 μg/mL and a sampling throughput of 36 samples/h with a reagent consumption of 3.3 mL per sample. The system was adjusted later to multiple analyte detection by including a second potentiometric cell on the LTCC/μPOT device. No additional reference electrode was required. This concept was applied to Trimethoprim (TMP), always administered concomitantly with sulphonamide drugs, and tested in fish-farming waters. The biparametric microanalyzer displayed Nernstian behaviour, with average slopes −54.7 (SMX) and +57.8 (TMP) mV/decade. To demonstrate the microanalyzer capabilities for real applications, it was successfully applied to single and simultaneous determination of SMX and TMP in aquaculture waters.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sulfadiazine is an antibiotic of the sulfonamide group and is used as a veterinary drug in fish farming. Monitoring it in the tanks is fundamental to control the applied doses and avoid environmental dissemination. Pursuing this goal, we included a novel potentiometric design in a flow-injection assembly. The electrode body was a stainless steel needle veterinary syringe of 0.8-mm inner diameter. A selective membrane of PVC acted as a sensory surface. Its composition, the length of the electrode, and other flow variables were optimized. The best performance was obtained for sensors of 1.5-cm length and a membrane composition of 33% PVC, 66% onitrophenyloctyl ether, 1% ion exchanger, and a small amount of a cationic additive. It exhibited Nernstian slopes of 61.0 mV decade-1 down to 1.0×10-5 mol L-1, with a limit of detection of 3.1×10-6 mol L-1 in flowing media. All necessary pH/ionic strength adjustments were performed online by merging the sample plug with a buffer carrier of 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid, pH 4.9. The sensor exhibited the advantages of a fast response time (less than 15 s), long operational lifetime (60 days), and good selectivity for chloride, nitrite, acetate, tartrate, citrate, and ascorbate. The flow setup was successfully applied to the analysis of aquaculture waters. The analytical results were validated against those obtained with liquid chromatography–tandem mass spectrometry procedures. The sampling rate was about 84 samples per hour and recoveries ranged from 95.9 to 106.9%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work proposes different kind of solid-contact graphite-based electrodes for the selective determination of sulphonamides (SPHs) in pharmaceuticals, biological fluids and aquaculture waters. Sulfadiazine (SDZ) and sulfamethoxazole (SMX) were selected for this purpose for being the most representative compounds of this group. The template molecules were imprinted in sol–gel (ISG) and the resulting material was used as detecting element. This was made by employing it as either a sensing layer or an ionophore of PVC-based membranes and subsequent potentiometric transduction, a strategy never reported before. The corresponding non-imprinted sol–gel (NISG) membranes were used as blank. The effect of plasticizer and kind/charge of ionic lipophilic additive was also studied. The best performance in terms of slope, linearity ranges and signal reproducibility and repeatability was achieved by PVC membranes including a high dielectric constant plasticizer and 15 mg of ISG particles. The corresponding average slope was −51.4 and −52.4 mV/decade, linear responses were 9.0 × 10−6 and 1.7 × 10−5 M, and limits of detection were 0.74 and 1.3 μg/mL for SDZ and for SMX, respectively. Good selectivity with log Kpot < −0.3 was observed for carbonate, chloride, fluoride, hydrogenocarbonate, nitrate, nitrite, phosphate, cyanide, sulfate, borate, persulphate, citrate, tartrate, salicylate, tetracycline, ciprofloxacin, sulphamerazine, sulphatiazole, dopamine, glucose, galactose, cysteine and creatinine. The best sensors were successfully applied to the analysis of real samples with relative errors ranging from −6.8 to + 3.7%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Solid-contact sensors for the selective screening of sulfadiazine (SDZ) in aquaculture waters are reported. Sensor surfaces were made from PVC membranes doped with tetraphenylporphyrin-manganese(III) chloride, α-cyclodextrin, β-cyclodextrin, or γ-cyclodextrin ionophores that were dispersed in plasticizer. Some membranes also presented a positive or a negatively charged additive. Phorphyrin-based sensors relied on a charged carrier mechanism. They exhibited a near-Nernstian response with slopes of 52 mV decade−1 and detection limits of 3.91 × 10−5 mol L−1. The addition of cationic lipophilic compounds to the membrane originated Nernstian behaviours, with slopes ranging 59.7–62.0 mV decade−1 and wider linear ranges. Cyclodextrin-based sensors acted as neutral carriers. In general, sensors with positively charged additives showed an improved potentiometric performance when compared to those without additive. Some SDZ selective membranes displayed higher slopes and extended linear concentration ranges with an increasing amount of additive (always <100% ionophore). The sensors were independent from the pH of test solutions within 2–7. The sensors displayed fast response, always <15 s. In general, a good discriminating ability was found in real sample environment. The sensors were successfully applied to the fast screening of SDZ in real waters samples from aquaculture fish farms. The method offered the advantages of simplicity, accuracy, and automation feasibility. The sensing membrane may contribute to the development of small devices allowing in locus measurements of sulfadiazine or parent-drugs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work proposes a new biomimetic sensor material for trimethoprim. It is prepared by means of radical polymerization, having trimethylolpropane trimethacrylate as cross-linker, benzoyl peroxide as radicalar iniciator, chloroform as porogenic solvent, and methacrylic acid and 2-vinyl pyridine as monomers. Different percentages of sensor in a range between 1 and 6% were studied. Their behavior was compared to that obtained with ion-exchanger quaternary ammonium salt (additive tetrakis(p-chlorophenyl)borate or tetraphenylborate). The effect of an anionic additive in the sensing membrane was also tested. Trimethoprim sensors with 1% of imprinted particles from methacrylic acid monomers showed the best response in terms of slope (59.7 mV/decade) and detection limit (4.01 × 10− 7 mol/L). These electrodes displayed also a good selectivity towards nickel, manganese aluminium, ammonium, lead, potassium, sodium, iron, chromium, sulfadiazine, alanine, cysteine, tryptophan, valine and glycine. The sensors were not affected by pH changes from 2 to 6. They were successfully applied to the analysis of water from aquaculture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Descrevemos a “ferradura de Smale”, um sistema dinâmico bem conhecido que apresenta um conjunto de propriedades muito importantes em Sistemas Dinâmicos. O estudo da dinâmica da “ferradura de Smale” permitenos entender a importância do conceito de dinâmica simbólica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O e-mail é atualmente a principal forma de comunicação das organizações. A informação existente nos e-mails representa uma elevada dimensão do capital não tangível das empresas, o Conhecimento. Na realidade, a gestão do e-mail dentro da organização é realizada por cada colaborador individualmente. Contudo, e tendo em conta o volume de informação criada, a forma como o e-mail é gerido levanta algumas questões. O objetivo geral deste estudo é conhecer como é feita a gestão de e-mail nos Serviços do Instituto Politécnico de Viana do Castelo (IPVC), analisando a forma de utilização do e-mail, de modo a obter elementos que permitam desenvolver normas/orientações para melhoria desta gestão. A metodologia utilizada para a elaboração deste trabalho de investigação recaiu sobre o Método Quadripolar, através do estudo de caso, para analisar a gestão do e-mail nos Serviços do IPVC. Foi elaborado um inquérito por questionário numa primeira fase, dirigido a todas as Instituições Públicas de Ensino Superior em Portugal sobre a existência de politicas de gestão de e-mail e, posteriormente, um questionário dirigido a todos os funcionários de todos os Serviços do IPVC no sentido de perceber de que forma se lida com o e-mail e com a sua gestão no contexto laboral de uma organização. A análise de dados foi efetuada através do estabelecimento da relação/associação entre variáveis com recurso à estatística descritiva. Os resultados demonstram que ainda há um longo caminho a percorrer uma vez que ainda não há uma consciencialização permanente para a importância do e-mail, bem como da sua gestão, no sentido de conseguir recuperar a informação de uma forma célere e garantir a preservação do e-mail a longo prazo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This research focuses on the influence of company sector and size on the level of utilization of Basic and Advanced Quality Tools. The paper starts with a literature review and then presents the methodology used for the survey. Based on the responses from 202 managers of Portuguese ISO 9001:2008 Quality Management System certified organizations, statistical tests were performed. Results show, with 95% confidence level, that industry and services have a similar proportion of use of Basic and Advanced Quality Tools. Concerning size, bigger companies show a higher trend to use Advanced Quality Tools than smaller ones. For Basic Quality Tools, there was no statistical significant difference at a 95% confidence level for different company sizes. The three basic Quality tools with higher utilization were Check sheets, Flow charts and Histograms (for Services) or Control Charts/ (for Industry), however 22% of the surveyed organizations reported not using Basic Quality Tools, which highlights a major improvement opportunity for these companies. Additional studies addressing motivations, benefits and barriers for Quality Tools application should be undertaken for further validation and understanding of these results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We consider two Cournot firms, one located in the home country and the other in the foreign country, producing substitute goods for consumption in a third country. We suppose that neither the home government nor the foreign firm know the costs of the home firm, while the foreign firm cost is common knowledge. We determine the separating sequential equilibrium outputs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We consider a symmetric Stackelberg model in which there is asymmetric demand information owned by first and second movers. We analyse the advantages of leadership and flexibility, and prove that when the leading firm faces demand uncertainty, but the follower does not, the first mover does not necessarily have advantage over the second mover. Moreover, we show that the advantage of one firm over the other depends upon the demand fluctuation and also upon the degree of substitutability of the products.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We consider a price competition in a duopoly with substitutable goods, linear and symmetric demand. There is a firm (F 1) that chooses first the price p 1 of its good; the other firm (F 2) observes p 1 and then chooses the price p 2 of its good. The conclusions of this price-setting dynamical duopoly are substantially altered by the presence of either differentiated goods or asymmetric information about rival’s production costs. In this paper, we consider asymmetric information about rival’s production costs. We do ex-ante and ex-post analyses of firms’ profits and market prices. We compare the ex-ante firms’ expected profits with the ex-post firms’ profits.