24 resultados para Error-Related Negativity
Resumo:
There is a growing socioeconomic recognition that clinical bone diseases such as bone infections, bone tumors and osteoporotic bone loss mainly associated with ageing, are major issues in today0s society. SPARC (secreted protein, acidic and rich in cysteine), a matricellular glycoprotein, may be a promising therapeutic target for preventing or treating bone‐related diseases. In fact, SPARC is associated with tissue remodeling, repair, development, cell turnover, bone mineralization and may also participate in growth and progression of tumors, namely cancer‐related bone metastasis. Yet, the function of SPARC in such biological processes is poorly understood and controversial. The main objective of this work is to review the current knowledge related to the activity of SPARC in bone remodeling, tumorigenesis, and bone metastasis. Progress in understanding SPARC biology may provide novel strategies for bone regeneration and the development of anti‐angiogenic, anti‐proliferative, or counter‐adhesive treatments specifically against bone metastasis.
Resumo:
Gamma radiations measurements were carried out in the vicinity of a coal-fired power plant located in the southwest coastline of Portugal. Two different gamma detectors were used to assess the environmental radiation within a circular area of 20 km centred in the coal plant: a scintillometer (SPP2 NF, Saphymo) and a high purity germanium detector (HPGe, Canberra). Fifty urban and suburban measurements locations were established within the defined area and two measurements campaigns were carried out. The results of the total gamma radiation ranged from 20.83 to 98.33 counts per second (c.p.s.) for both measurement campaigns and outdoor doses rates ranged from 77.65 to 366.51 Gy/h. Natural emitting nuclides from the U-238 and Th-232 decay series were identified as well as the natural emitting nuclide K-40. The radionuclide concentration from the uranium and thorium series determined by gamma spectrometry ranged from 0.93 to 73.68 Bq/kg, while for K-40 the concentration ranged from 84.14 to 904.38 Bq/kg. The obtained results were used primarily to define the variability in measured environmental radiation and to determine the coal plant’s influence in the measured radiation levels. The highest values were measured at two locations near the power plant and at locations between the distance of 6 and 20 km away from the stacks, mainly in the prevailing wind direction. The results showed an increase or at least an influence from the coal-fired plant operations, both qualitatively and quantitatively.
Resumo:
A exploração do meio subaquático utilizando visão computacional é ainda um processo complexo. Geralmente são utilizados sistemas de visão baseados em visão stereo, no entanto, esta abordagem apresenta limitações, é pouco precisa e é exigente em termos computacionais quando o meio de operação é o subaquático. Estas limitações surgem principalmente em dois cenários de aplicação: quando existe escassez de iluminação e em operações junto a infraestruturas subaquáticas. Consequentemente, a solução reside na utilização de fontes de informação sensorial alternativas ou complementares ao sistema de visão computacional. Neste trabalho propõe-se o desenvolvimento de um sistema de percepção subaquático que combina uma câmara e um projetor laser de um feixe em linha, onde o projetor de luz estruturada _e utilizado como fonte de informação. Em qualquer sistema de visão computacional, e ainda mais relevante em sistemas baseados em triangulação, a sua correta calibração toma um papel fulcral para a qualidade das medidas obtidas com o sistema. A calibração do sistema de visão laser foi dividida em duas etapas. A primeira etapa diz respeito à calibração da câmara, onde são definidos os parâmetros intrínsecos e os parâmetros extrínsecos relativos a este sensor. A segunda etapa define a relação entre a câmara e o laser, sendo esta etapa necessária para a obtenção de imagens tridimensionais. Assim, um dos principais desafios desta dissertação passou por resolver o problema da calibração inerente a este sistema. Desse modo, foi desenvolvida uma ferramenta que requer, pelo menos duas fotos do padrão de xadrez, com perspectivas diferentes. O método proposto foi caracterizado e validado em ambientes secos e subaquáticos. Os resultados obtidos mostram que o sistema _e preciso e os valores de profundidade obtidos apresentam um erro significativamente baixo (inferiores a 1 mm), mesmo com uma base-line (distância entre a centro óptico da câmara e o plano de incidência do laser) reduzida.
Resumo:
Dairy foods comprise a range of products with varying nutritional content. The intake of dairy products (DPs) has been shown to have beneficial effects on body weight and body fat. This study aimed to examine the independent association between DP intake, body mass index (BMI), and percentage body fat (%BF) in adolescents. A cross-sectional, school-based study was conducted with 1,001 adolescents (418 boys), ages 15–18 years, from the Azorean Archipelago, Portugal. Anthropometric measurements were recorded (weight and height), and %BF was assessed using bioelectric impedance analysis. Adolescent food intake was measured using a self-administered, semiquantitative food frequency questionnaire. Data were analyzed separately for girls and boys, and separate multiple linear regression analysis was used to estimate the association between total DP, milk, yogurt, and cheese intake, BMI, and %BF, adjusting for potential confounders. For boys and girls, respectively, total DP consumption was 2.6 ± 1.9 and 2.9 ± 2.5 servings/day (P = 0.004), while milk consumption was 1.7 ± 1.4 and 2.0 ± 1.7 servings/day (P = 0.001), yogurt consumption was 0.5 ± 0.6 and 0.4 ± 0.7 servings/day (P = 0.247), and cheese consumption was 0.4 ± 0.6 and 0.5 ± 0.8 servings/day (P = 0.081). After adjusting for age, birth weight, energy intake, protein, total fat, sugar, dietary fiber, total calcium intake, low-energy reporters, parental education, pubertal stage, and physical activity, only milk intake was negatively associated with BMI and %BF in girls (respectively, girls: β = −0.167, P = 0.013; boys: β = −0.019, P = 0.824 and girls: β = −0.143, P = 0.030; boys: β = −0.051, P = 0.548). Conclusion: We found an inverse association between milk intake and both BMI and %BF only in girls.
Resumo:
Low back problems are associated with decreased quality of life. Specific exercises can improve quality of life, resulting in better professional performance and functionality. The purpose of this study was to evaluate the effect of following a 21-month exercise program on the quality of life of warehouse workers. The population included 557 male warehouse workers from a food distribution company in Oporto, Portugal. Upon application of the selection criteria, 249 workers were deemed eligible, which were randomized into two groups (125 in the intervention group and 124 in the control group). Then, subjects were asked to volunteer for the study, the sample being formed by 229 workers (112 in the intervention group and 117 in the control group). All subjects completed the SF-36 questionnaire prior to beginning the program and on the 11th and 21st months following it. The exercises were executed in the company facilities once a day for 8 min. Data were analyzed using SPSS® 17.0 for Windows®. After 11 months of following the exercise program, there was an increase in all scores for the experimental group, with statistically significant differences in the dimensions physical functioning (0.019), bodily pain (0.010), general health (0.004), and rolephysical (0.037). The results obtained at the end of the study (21 months) showed significant improvements in the dimensions physical functioning (p = 0.002), rolephysical (p = 0.007), bodily pain (p = 0.001), social functioning (p = 0.015), role-emotional (p = 0.011), and mental health (p = 0.001). In the control group all dimensions showed a decrease in mean scores. It can be concluded that the implementation of a low back specific exercise program has changed positively the quality of life of warehouse workers.
Resumo:
Methamphetamine (METH) is a potent psychostimulant highly used worldwide. Recent studies evidenced the involvement of METH in the breakdown of the blood-brain-barrier (BBB) integrity leading to compromised function. The involvement of the matrix metalloproteinases (MMPs) in the degradation of the neurovascular matrix components and tight junctions (TJs) is one of the most recent findings in METH-induced toxicity. As BBB dysfunction is a pathological feature of many neurological conditions, unveiling new protective agents in this field is of major relevance. AcetylL-carnitine (ALC) has been described to protect the BBB function in different paradigms, but the mechanisms underling its action remain mostly unknown. Here, the immortalized bEnd.3 cell line was used to evaluate the neuroprotective features of ALC in METH-induced damage. Cells were exposed to ranging concentrations of METH, and the protective effect of ALC 1 mM was assessed 24 h after treatment. F-actin rearrangement, TJ expression and distribution, and MMPs activity were evaluated. Integrin-linked kinase (ILK) knockdown cells were used to assess role of ALC in ILK mediated METHtriggered MMPs’ activity. Our results show that METH led to disruption of the actin filaments concomitant with claudin-5 translocation to the cytoplasm. These events were mediated by MMP-9 activation in association with ILK overexpression. Pretreatment with ALC prevented METH-induced activation of MMP-9, preserving claudin-5 location and the structural arrangement of the actin filaments. The present results support the potential of ALC in preserving BBB integrity, highlighting ILK as a new target for the ALC therapeutic use.
Resumo:
BACKGROUND: Musicians are a prone group to suffer from working-related musculoskeletal disorder (WRMD). Conventional solutions to control musculoskeletal pain include pharmacological treatment and rehabilitation programs but their efficiency is sometimes disappointing. OBJECTIVE: The aim of this research is to study the immediate effects of Tuina techniques on WRMD of professional orchestra musicians from the north of Portugal. DESIGN, SETTING, PARTICIPANTS AND INTERVENTIONS: We performed a prospective, controlled, single-blinded, randomized study. Professional orchestra musicians with a diagnosis of WRMD were randomly distributed into the experimental group (n=39) and the control group (n=30). During an individual interview, Chinese diagnosis took place and treatment points were chosen. Real acupoints were treated by Tuina techniques into the experimental group and non-specific skin points were treated into the control group. Pain was measured by verbal numerical scale before and immediately after intervention. RESULTS: After one treatment session, pain was reduced in 91.8% of the cases for the experimental group and 7.9% for the control group. CONCLUSION: Although results showed that Tuina techniques are effectively reducing WRMD in professional orchestra musicians of the north of Portugal, further investigations with stronger measurements, double-blinding designs and bigger simple sizes are needed.
Resumo:
Este documento apresenta uma avaliação sobre o uso dos simuladores fisiológicos como padrão para avaliação metrológica dos esfigmomanómetros automáticos na estimação da pressão sanguínea pelo método não invasivo (PNI). O presente estudo procurou avaliar o enquadramento destes equipamentos com os procedimentos das normas e recomendações usadas para apreciação metrológica dos esfigmomanómetros digitais. No contexto da prática metrológica existente determinou-se a existência de uma oportunidade de melhoria nos processos relacionados. O trabalho procurou obter resposta a diversas questões, relacionando a medição da pressão pelo método não invasivo, com o uso dos simuladores fisiológicos, o contexto em que estes podem ser usados, as formas de simulação, as medições e os resultados, procurando a perspetiva metrológica como enquadramento. As recomendações existentes [1] [2] [3] [4] [5] [6] [7] [8], são muito claras nos procedimentos, validação e nos desvios permitidos para os monitores da tensão arterial (MTA), equipamento que permite a avaliação dos parâmetros fisiológicos do paciente, no entanto, quando se pretende avançar para outro domínio, como o do uso dos simuladores, em particular para a simulação da PNI, não existem recomendações ou normas tão claras, e não existe sobretudo um padrão de referência que imite a natureza dinâmica que caracteriza a pressão sanguínea. O trabalho procurou ainda estabelecer a ligação entre o método clássico de auscultação (o principio de determinação da PS), a técnica digital de medição e os simuladores, para uma melhor compreensão do que é a pressão sanguínea, e como relacionar a problemática da simulação e a de um padrão de referência. Neste trabalho estão ainda presentes abordagens a diversos tópicos, como as validações clínicas, acessórios, ou a metrologia e que influenciam no final os equipamentos e o contexto que se pretende avaliar. Os diversos equipamentos testados procuraram conter amostras diversificadas, quer para os MTA de uso profissional ou doméstico, assim como para os simuladores. A avaliação dos simuladores foi realizada contra um grupo de MTAs. Foi testada a influência na medição, causada pela mudança de acessórios, ou seja, nos resultados, merecendo consideração pela perspetiva metrológica. No resumo dos testes e do estudo sobre este tema, verificou-se que esta tipologia de equipamentos pode contribuir como complemento do processo de calibração típico (estático). Não constitui por si só um método alternativo, mas permitiu estimar possíveis limites de erro e desvio padrão a partir da observação dos resultados práticos, limites esses inferiores aos processos de validação clínica. Atendendo às particularidades, estimou-se como desvio aceitável um erro mais desvio padrão de 5 + 3 mmHg para o processo de simulação. Contudo considera-se ainda importante os testes adicionais em que o simulador permite, ao verificar as medidas de segurança implementadas no equipamento e a condição dos acessórios, que como verificado afetam os resultados. No entanto nem todos os simuladores se mostram adequados a este processo pelo que a qualidade da seleção do equipamento para este fim pode eventualmente reduzir ainda mais os possíveis limites.
Resumo:
Dissertação de Mestrado apresentado ao Instituto Superior de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Auditoria, sob orientação de Doutora Alcina de Sena Portugal Dias Esta versão contém as críticas e sugestões de elementos do júri