22 resultados para Determination of aluminium in water


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Phenol is a toxic compound present in a wide variety of foundry resins. Its quantification is important for the characterization of the resins as well as for the evaluation of free contaminants present in foundry wastes. Two chromatographic methods, liquid chromatography with ultraviolet detection (LC-UV) and gas chromatography with flame ionization detection (GC-FID), for the analysis of free phenol in several foundry resins, after a simple extraction procedure (30 min), were developed. Both chromatographic methods were suitable for the determination of phenol in the studied furanic and phenolic resins, showing good selectivity, accuracy (recovery 99–100%; relative deviations <5%), and precision (coefficients of variation <6%). The used ASTM reference method was only found to be useful in the analysis of phenolic resins, while the LC and GC methods were applicable for all the studied resins. The developed methods reduce the time of analysis from 3.5 hours to about 30 min and can readily be used in routine quality control laboratories.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cyanobacteria deteriorate the water quality and are responsible for emerging outbreaks and epidemics causing harmful diseases in Humans and animals because of their toxins. Microcystin-LR (MCT) is one of the most relevant cyanotoxin, being the most widely studied hepatotoxin. For safety purposes, the World Health Organization recommends a maximum value of 1 μg L−1 of MCT in drinking water. Therefore, there is a great demand for remote and real-time sensing techniques to detect and quantify MCT. In this work a Fabry–Pérot sensing probe based on an optical fibre tip coated with a MCT selective thin film is presented. The membranes were developed by imprinting MCT in a sol–gel matrix that was applied over the tip of the fibre by dip coating. The imprinting effect was obtained by curing the sol–gel membrane, prepared with (3-aminopropyl) trimethoxysilane (APTMS), diphenyl-dimethoxysilane (DPDMS), tetraethoxysilane (TEOS), in the presence of MCT. The imprinting effect was tested by preparing a similar membrane without template. In general, the fibre Fabry–Pérot with a Molecular Imprinted Polymer (MIP) sensor showed low thermal effect, thus avoiding the need of temperature control in field applications. It presented a linear response to MCT concentration within 0.3–1.4 μg L−1 with a sensitivity of −12.4 ± 0.7 nm L μg−1. The corresponding Non-Imprinted Polymer (NIP) displayed linear behaviour for the same MCT concentration range, but with much less sensitivity, of −5.9 ± 0.2 nm L μg−1. The method shows excellent selectivity for MCT against other species co-existing with the analyte in environmental waters. It was successfully applied to the determination of MCT in contaminated samples. The main advantages of the proposed optical sensor include high sensitivity and specificity, low-cost, robustness, easy preparation and preservation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The electrochemical behavior of the hydrolysis products of oxadiazon was studied by cyclic and square-wave voltammetry using a glassy carbon electrode. Maximum currents were obtained at pH 12.8 in an aqueous electrolyte solution containing 30% ethanol and the current did not decrease with time showing that there was little adsorption of the reaction products on the electrode surface. The hydrolysis products of oxadiazon were identi®ed, after isolation and puri®cation, as 1-trimethylacetyl-2-(2,4-dichloro-5-isopropoxyphenyl)-2-ethoxycarbonylhydrazine (Oxa1) and 1-trimethylacetyl-2-(2,4-dichloro-5-isopropoxyphenyl) hydrazine (Oxa2) with redox potentials 0.6Vand 70.1V (vs. Ag=AgCl), respectively. Based on the electrochemical behavior of 1-trimethylacetyl-2-(2,4-dichloro-5-isopropoxyphenyl) hydrazine (Oxa2) a simple electroanalytical procedure was developed for the determination of oxadiazon in commercial products used in the treatment of rice crops in Portugal that contain oxadiazon as the active ingredient. The detection limit was 161074 M, the mean content and relative standard deviation obtained for seven samples of two different commercial products by the electrochemical method were 28.4 0.8% (Ronstar) and 1.9 0.2% (Ronstar GR), and the recoveries were 100.3 5.4% and 101.1 5.3 %, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A square-wave voltammetric (SWV) method and a flow injection analysis system with amperometric detection were developed for the determination of tramadol hydrochloride. The SWV method enables the determination of tramadol over the concentration range of 15-75 µM with a detection limit of 2.2 µM. Tramadol could be determined in concentrations between 9 and 50 µM at a sampling rate of 90 h-1, with a detection limit of 1.7 µM using the flow injection system. The electrochemical methods developed were successfully applied to the determination of tramadol in pharmaceutical dosage forms, without any pre-treatment of the samples. Recovery trials were performed to assess the accuracy of the results; the values were between 97 and 102% for both methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Trihalomethanes (THMs) are widely referred and studied as disinfection by-products (DBPs). The THMs that are most commonly detected are chloroform (TCM), bromodichloromethane (BDCM), chlorodibromomethane (CDBM), and bromoform (TBM). Several studies regarding the determination of THMs in swimming pool water and air samples have been published. This paper reviews the most recent work in this field, with a special focus on water and air sampling, sample preparation and analytical determination methods. An experimental study has been developed in order to optimize the headspace solid-phasemicroextraction (HS-SPME) conditions of TCM, BDCM, CDBM and TBM from water samples using a 23 factorial design. An extraction temperature of 45 °C, for 25min, and a desorption time of 5 min were found to be the best conditions. Analysis was performed by gas chromatography with an electron capture detector (GC-ECD). The method was successfully applied to a set of 27 swimming pool water samples collected in the Oporto area (Portugal). TCM was the only THM detected with levels between 4.5 and 406.5 μg L−1. Four of the samples exceeded the guideline value for total THMs in swimming pool water (100 μgL−1) indicated by the Portuguese Health Authority.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The immobilization and electro-oxidation of guanine and adenine asDNA bases on glassy carbon electrode are evaluated by square wave voltammetric analysis. The influence of electrochemical pretreatments, nature of supporting electrolyte, pH, accumulation time and composition of DNA nucleotides on the immobilization effect and the electrochemical mechanism are discussed. Trace levels of either guanine or adenine can be readily detected following short accumulation time with detection limits of 35 and 40 ngmL−1 for guanine and adenine, respectively. The biosensors of guanine and adenine were employed for the voltammetric detection of antioxidant capacity in flavored water samples. The method relies on monitoring the changes of the intrinsic anodic response of the surface-confined guanine and adenine species, resulting from its interaction with free radicals from Fenton-type reaction in absence and presence of antioxidant. Ascorbic acid was used as standard to evaluate antioxidant capacities of samples. Analytical data was compared with that of FRAP method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main objective of this work was to develop an application capable of determining the diffusion times and diffusion coefficients of optical clearing agents and water inside a known type of muscle. Different types of chemical agents can also be used with the method implemented, such as medications or metabolic products. Since the diffusion times can be calculated, it is possible to describe the dehydration mechanism that occurs in the muscle. The calculation of the diffusion time of an optical clearing agent allows to characterize the refractive index matching mechanism of optical clearing. By using both the diffusion times and diffusion of water and clearing agents not only the optical clearing mechanisms are characterized, but also information about optical clearing effect duration and magnitude is obtained. Such information is crucial to plan a clinical intervention in cooperation with optical clearing. The experimental method and equations implemented in the developed application are described in throughout this document, demonstrating its effectiveness. The application was developed in MATLAB code, but the method was personalized so it better fits the application needs. This process significantly improved the processing efficiency, reduced the time to obtain he results, multiple validations prevents common errors and some extra functionalities were added such as saving application progress or export information in different formats. Tests were made using glucose measurements in muscle. Some of the data, for testing purposes, was also intentionally changed in order to obtain different simulations and results from the application. The entire project was validated by comparing the calculated results with the ones found in literature, which are also described in this document.