41 resultados para indoor management rule

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fungi are essential to the survival of our global ecology, but they might pose a significant threat to the health of occupants when they grow in our buildings. The exposure to fungi in homes is a significant risk factor for a number of respiratory symptoms. Well-known illnesses caused by fungi include allergy and hypersensitivity pneumonitis. Environmental monitoring for fungi and their disease agents are important aspects of exposure assessment, but few guidelines exist for interpreting their health impacts. This book answers the questions: How does one detect and measure the presence of indoor fungi? What is an acceptable level of indoor fungi? How do we relate this information to human health problems?

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fungal contamination of air in 10 gymnasiums with swimming pools was monitored. Fifty air samples of 200 L each were collected, using a Millipore air tester, from the area surrounding the pool, in training studios, in showers and changing rooms for both sexes, and also, outside premises, since these are the places regarded as reference. Simultaneously, environmental parameters – temperature and humidity – were also monitored. Some 25 different species of fungi were identified. The six most commonly isolated genera were the following: Cladosporium sp. (36.6%), Penicillium sp. (19.0%), Aspergillus sp. (10.2%), Mucor sp. (7%), Phoma sp. and Chrysonilia sp. (3.3%). For yeasts, three different genera were identified, namely, Rhodotorula sp. (70%), Trichosporon mucoides and Cryptococcus uniguttulattus (10%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Formaldehyde was the first air pollutant, which already in the 1970s emerged as a specifically non-industrial indoor air quality problem. Yet formaldehyde remained an indoor air quality issue and the formaldehyde level in residential indoor air is among the highest of any indoor air contaminant. Formaldehyde concentrations in 4 different indoor settings (schools, office buildings, new dwellings and occupied dwellings) in Portugal were measured using Photo Ionization Detection (PID) equipment (11,7 eV lamps). All the settings presented results higher than the reference value proposed by Portuguese legislation. Furthermore, occupied dwellings showed 3 units with results above the reference. We could conclude that formaldehyde presence is a reality in monitored indoor settings. Concentration levels are higher than the Portuguese reference value for indoor settings and these can indicate health problems for occupants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A biomonitoring study, using transplanted lichens Flavoparmelia caperata, was conducted to assess the indoor air quality in primary schools in urban (Lisbon) and rural (Ponte de Sor) Portuguese sites. The lichens exposure period occurred between April and June 2010 and two types of environments of the primary schools were studied: classrooms and outdoor/courtyard. Afterwards, the lichen samples were processed and analyzed by instrumental neutron activation analysis (INAA) to assess a total of 20 chemical elements. Accumulated elements in the exposed lichens were assessed and enrichment factors (EF) were determined. Indoor and outdoor biomonitoring results were compared to evaluate how biomonitors (as lichens) react at indoor environments and to assess the type of pollutants that are prevalent in those environments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Total particulate matter (TPM) was passively collected inside two classrooms of each of five elementary schools in Lisbon, Portugal. TPM was collected in polycarbonate filters with a 47 mm diameter, placed inside of uncovered plastic petri dishes. The sampling period was from 19 May to 22 June 2009 (35 days exposure) and the collected TPM masses varied between 0.2 mg and 0.8 mg. The major elements were Ca, Fe, Na, K, and Zn at μg level, while others were at ng level. Pearson′s correlation coefficients above 0.75 (a high degree of correlation) were found between several elements. Soil-related, traffic soil re-suspension and anthropogenic emission sources could be identified. Blackboard chalk was also identified through Ca large presence. Some of the determined chemical elements are potential carcinogenic. Quality control of the results showed good agreement as confirmed by the application of u-score test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clean air is a basic requirement of life. The Indoor Air Quality (IAQ) has been the object of several studies due to an increasing concern within the scientific community on the effects of indoor air quality upon health, especially as people tend to spend more time indoors than outdoors. The quality of air inside homes, offices, schools or other private and public buildings is an essential determinant of healthy life and people’s well-being. People can be exposed to contaminants by inhalation, ingestion and dermal contact. In the past, scientists have paid much attention to the study of exposure to outdoor air contaminants, because they have realised the seriousness of outdoor air pollution problems. However, each indoor microenvironment has unique characteristics, determined by the local outdoor air, specific building characteristics and indoor activities. Indeed, hazardous substances are emitted from buildings, construction materials and indoor equipment or due to human activities indoors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este relatório de estágio, que se realizou no Edifício Atrium Saldanha em Lisboa, tem por finalidade demonstrar as aptidões adquiridas no decorrer do Mestrado e que tornaram possíveis a participação num estágio que envolveu várias áreas da Engenharia Mecânica. Nos últimos anos, tem-se assistido a um crescente aumento do consumo e do custo da energia eléctrica. De acordo com análises realizadas pela União Europeia, uma percentagem significativa deste aumento de consumo está relacionado com edifícios e habitações. A manutenção preventiva das instalações técnicas é, entre outros aspectos, uma das ferramentas essenciais na redução desta factura energética. A questão que se coloca relaciona-se com a metodologia a aplicar para esse efeito. De que forma podem ou devem os planos de manutenção ser elaborados, qual a periodicidade das intervenções a considerar de modo a aumentar a eficiência energética dos edifícios, reduzir as emissões de dióxido de carbono e garantir uma maior protecção do utilizador? Numa fase inicial do estágio foi feita uma caracterização geral das principais instalações técnicas do edifício de modo a se analisarem, posteriormente, os procedimentos de manutenção adoptados pelas equipas de manutenção. Foram ainda sugeridas algumas periodicidades para os procedimentos de manutenção já existentes e algumas intervenções que não estavam incluídas no plano de manutenção do edifício e que podem contribuir para aumentar a fiabilidade dos equipamentos e consequentemente a eficiência energética e a qualidade do ar interior dos edifícios.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As redes de telecomunicações nos últimos anos têm sofrido um grande desenvolvimento a nível tecnológico. A prova disso é a revolução das redes sem fios, iniciada com a tecnologia GSM (Global System Mobile) nos anos 90, na qual eram apenas disponibilizados serviços de voz. Esta tendência continuou com o GPRS (General Packet Radio Service) onde se iniciaram os serviços de dados surgindo assim mais tarde, a tecnologia UMTS (Universal Mobile Telecommunications System). Com o aparecimento da nova tecnologia LTE (Long-Term Evolution), surgiu um novo paradigma consumista no mercado, facto que gerou um conflicto directo com as redes de banda larga (ADSL - Asymmetric Digital Subscriber Line) fornecidas anteriormente apenas pela rede fixa. A partir deste momento, estas duas tecnologias passaram a oferecer altos débitos de dados, eliminando assim esta diferenciação existente até então entre ambas. Esta foi a plataforma que despoletou o meu interesse em explorar a tecnologia LTE, mais precisamente, o planeamento de rádio em ambientes Indoor e Outdoor. Este planeamento requeria uma comparação prática e teórica, de forma a observar que a tecnologia reflectia os valores estipulados na norma LTE. Como método de comparação foi utilizada uma ferramenta de planeamento de redes móveis, gentilmente disponibilizada pela Alcatel-Lucent para o tipo de ambiente outdoor em estudo, para o indoor não foi efectuado simulação, por indisponibilidade da ferramenta. Após a configuração do sistema de rádio foi efectuada a recolha de dados no terreno através de drive-testes. Findo esta fase, procedeu-se ao pós-processamento e análise dos dados recolhidos, por forma a ser possível estabelecer a comparação entre o planeamento teórico efectuado através da ferramenta de planeamento e os dados capturados no terreno. Os resultados obtidos demonstram que a cobertura preconizada no caso Outdoor estavam de acordo com o planeamento efectuado, uma vez que os dados medidos no terreno coincidiram com os valores simulados, apenas com um desvio mínimo dentro da margem de tolerância. No que respeita ao indoor verificou-se que as medidas estavam de acordo com o estipulado na norma. Como conclusão, confirmou-se a validade das ferramentas e da metodologia utilizada.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this paper is concerned with the design and development of a functional framework for maritime mode integration in European automotive supply chain management when considering outbound distribution. Furthermore, it provides a readjustment of traditional concepts and terminology with findings that the role of ro-ro port terminals should be considered as decoupling points, poles and postponement platforms. Case studies examine relevant Western European ro-ro port terminals for cars and respective links to assembly/factories of vehicles localized in the hinterland and concludes that ro-ro port terminals reduce logistical friction and impedance, as well as promote space/time compression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A descriptive study was developed in order to compare indoor and outdoor air contamination caused by fungi and particles in seven poultry units. Twenty eight air samples of 25 litters were collected through the impaction method on malt extract agar. Air sampling and particles concentration measurement were done in the interior and also outside premises of the poultries’ pavilions. Regarding the fungal load in the air, indoor concentration of mold was higher than outside air in six poultry units. Twenty eight species / genera of fungi were identified indoor, being Scopulariopsis brevicaulis (40.5%) the most commonly isolated species and Rhizopus sp. (30.0%) the most commonly isolated genus. Concerning outdoor, eighteen species/genera of fungi were isolated, being Scopulariopsis brevicaulis (62.6%) also the most isolated. All the poultry farms analyzed presented indoor fungi different from the ones identified outdoors. Regarding particles’ contamination, PM2.5, PM5.0 and PM10 had a statistically significant difference (Mann-Whitney U test) between the inside and outside of the pavilions, with the inside more contaminated (p=.006; p=.005; p=.005, respectively). The analyzed poultry units are potential reservoirs of substantial amounts of fungi and particles and could therefore free them in the atmospheric air. The developed study showed that indoor air was more contaminated than outdoors, and this can result in emission of potentially pathogenic fungi and particles via aerosols from poultry units to the environment, which may post a considerable risk to public health and contribute to environmental pollution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the management of solid waste, pollutants over a wide range are released with different routes of exposure for workers. The potential for synergism among the pollutants raises concerns about potential adverse health effects, and there are still many uncertainties involved in exposure assessment. In this study, conventional (culture-based) and molecular real-time polymerase chain reaction (RTPCR) methodologies were used to assess fungal air contamination in a waste-sorting plant which focused on the presence of three potential pathogenic/toxigenic fungal species: Aspergillus flavus, A. fumigatus, and Stachybotrys chartarum. In addition, microbial volatile organic compounds (MVOC) were measured by photoionization detection. For all analysis, samplings were performed at five different workstations inside the facilities and also outdoors as a reference. Penicillium sp. were the most common species found at all plant locations. Pathogenic/toxigenic species (A. fumigatus and S. chartarum) were detected at two different workstations by RTPCR but not by culture-based techniques. MVOC concentration indoors ranged between 0 and 8.9 ppm (average 5.3 ± 3.16 ppm). Our results illustrated the advantage of combining both conventional and molecular methodologies in fungal exposure assessment. Together with MVOC analyses in indoor air, data obtained allow for a more precise evaluation of potential health risks associated with bioaerosol exposure. Consequently, with this knowledge, strategies may be developed for effective protection of the workers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Indoor air quality recently entered legislation in Portugal. Several parameters must be evaluated and kept within limits in order to obtain a certification for air quality and energy consumption. Certification parameters were analyzed in two Portuguese archives in order to assess indoor air quality both for people attending or working on these premises and for maintenance of a written heritage that must be retained for future generations. Carbon monoxide (CO) and carbon dioxide (CO2), formaldehyde, and fungal counts were kept within stipulated limits. Relative humidity (RH), volatile organic compounds (VOC), particulate matter (PM10), and ozone (O3) showed values above legislated levels and justified the implementation of corrective measures. In terms of conservation, studies on the limit values are still needed, but according to the available international guidelines, some of the analyzed parameters such as PM10, O3, and RH were also above desirable values. Corrective measures were proposed to these institutions. Although this study was only of a short duration, it proved valuable in assessing potential eventual problems and constitutes the first Portuguese indoor air quality assessment taking into consideration both aspects of an archive such as human health and heritage safekeeping.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Indoor localization systems in nowadays is a huge area of interest not only at academic but also at industry and commercial level. The correct location in these systems is strongly influenced by antennas performance which can provide several gains, bandwidths, polarizations and radiation patterns, due to large variety of antennas types and formats. This paper presents the design, manufacture and measurement of a compact microstrip antenna, for a 2.4 GHZ frequency band, enhanced with the use of Electromagnetic Band-Gap (EBG) structures, which improve the electromagnetic behavior of the conventional antennas. The microstrip antenna with an EBG structure integrated allows an improvement of the location system performance in about 25% to 30% relatively to a conventional microstrip antenna.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, a novel mixed-integer nonlinear approach is proposed to solve the short-term hydro scheduling problem in the day-ahead electricity market, considering not only head-dependency, but also start/stop of units, discontinuous operating regions and discharge ramping constraints. Results from a case study based on one of the main Portuguese cascaded hydro energy systems are presented, showing that the proposedmixed-integer nonlinear approach is proficient. Conclusions are duly drawn. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sendo os desperdícios “Waste” associados à atividade industrial em Portugal e nos mercados globais e os seus custos inerentes, uma das maiores preocupações a todos os níveis de gestão empresarial, a filosofia “Lean” nasce como ajuda e encaminhamento na solução desta problemática. O conceito “Lean”, no que se refere à indústria, desde sempre e até aos dias de hoje, tem uma enorme ênfase, com a adoção deste conceito.Verificam-se bons resultados ao nível da redução de custos, melhoria da qualidade geral dos artigos produzidos, no controlo da produção em geral e é uma poderosa ferramenta no estreitamento da relação entre os diferentes intervenientes da cadeia de valor de determinado produto, sobretudo com fornecedores e com clientes. Com “Lean Management” e “Glass Wall Management”, em ambientes onde as empresas mais avançadas estão a procurar melhorar a sua competitividade através de uma gestão transparente (“Glass Wall Management”), a partir da qual, “toda informação relevante é compartilhada de maneira a que todos entendam a situação”(Suzaki, K, 1993), ganha cada vez mais importância a existência de uma estrutura organizacional que permita esta transparência e a consequente maturidade das empresas. Neste trabalho foram descritos alguns processos de gestão transparente desenvolvidos nos últimos dois anos numa PME portuguesa, aprofundando o processo de gestão transparente vigente e as ferramentas que ajudam a empresa e que na sua globalidade poderão ser extrapoladas a outras PME Portuguesas de modo que a informação importante e relevante seja partilhada por todos os intervenientes na estrutura empresarial, sendo entendida e desenvolvida por todos através de Edições e Revisões aos documentos mais importantes da empresa. Neste estudo foram contactadas vinte e uma PME’S portuguesas de tipologia de produção MTO (Make to Order) do sector dos estofos/mobiliário, e solicitado o preenchimento de um Questionário, tendo como fim em vista, a verificação do uso desta metodologia “Glass Wall Management” à escala empresarial portuguesa e a interpretação do Conceito Geral “Lean” como filosofia de redução de materiais, tempos e custos.