8 resultados para Simple bone cyst
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
We use the first and second laws of thermodynamics to analyze the behavior of an ideal jet engine. Simple analytical expressions for the thermal efficiency, the overall efficiency, and the reduced thrust are derived. We show that the thermal efficiency depends only on the compression ratio r and on the velocity of the aircraft. The other two performance measures depend also on the ratio of the temperature at the turbine to the inlet temperature in the engine, T-3/T-i. An analysis of these expressions shows that it is not possible to choose an optimal set of values of r and T-3/T-i that maximize both the overall efficiency and thrust. We study how irreversibilities in the compressor and the turbine decrease the overall efficiency of jet engines and show that this effect is more pronounced for smaller T-3/T-i.
Resumo:
The first examples of low temperature N-oxy-3-aza Cope rearrangements, leading to functionalised allenes are described, where the Z-configuration of the enaminic double bond in the rearranging system proves critical.
Resumo:
The main purpose of the present study is to determine if the circadian rhythms present in the human bone marrow are likely to influence 3’- deoxy- 3’-[18F] Fluorothymidine (18F-FLT) uptake in the same organ. The 18F-FLT is a Thymidine analogous proliferation agent. The relatively high physiological uptake of this tracer in the bone marrow diminishes the Tumor/Background (T/B) ratio, decreasing the detection accuracy of PET/CT and possibly affecting SUV quantifications.
Resumo:
Les temps du passé ont toujours constitué une pierre d’achoppement aussi bien dans l’enseignement du français aux étudiants lusophones que dans celui du portugais aux francophones. Le flot continu d’articles sur ce sujet attesterait, à lui seul, la difficulté du problème. Mais aussi étonnant que cela puisse paraître, il n’existe à ce jour aucune étude systématique qui aborde sur une base théorique le présent simple dans le passage du français vers le portugais et/ou vice-versa. Or, une telle étude nous paraît une voie de recherche intéressante et fructueuse qui ouvre de nombreuses perspectives de recherche, dont les possibilités d’application, que ce soit au domaine de l’enseignement des langues étrangères ou celui de la traduction, ne sont pas négligeables. Cette réflexion est d’autant plus urgente que l’emploi du présent simple pose de sérieux problèmes aux élèves lusophones plus inexpérimentés. En effet, ces derniers ont parfois beaucoup de peine à trouver les bonnes correspondances du présent simple en portugais. Afin d’aboutir à des conclusions fiables sur les similarités et les divergences entre le français et le portugais quant aux conditions d’apparition et au mode de fonctionnement du présent simple, nous nous attacherons, dans l’étude contrastive qui suit, à examiner des échantillons de textes littéraires français traduits en portugais et des extraits de textes littéraires portugais traduits en français1. Il s’agira essentiellement de montrer, en recourant à la Théorie des Opérations Énonciatives d’Antoine Culioli (Culioli, 1990; Campos & Xavier, 1991; Campos, 1997, 1998, entre autres), par quels moyens linguistiques le portugais exprime les valeurs aspectuo-temporelles associées au présent simple en français.
The use of non-standard CT conversion ramps for Monte Carlo verification of 6 MV prostate IMRT plans
Resumo:
Monte Carlo (MC) dose calculation algorithms have been widely used to verify the accuracy of intensity-modulated radiotherapy (IMRT) dose distributions computed by conventional algorithms due to the ability to precisely account for the effects of tissue inhomogeneities and multileaf collimator characteristics. Both algorithms present, however, a particular difference in terms of dose calculation and report. Whereas dose from conventional methods is traditionally computed and reported as the water-equivalent dose (Dw), MC dose algorithms calculate and report dose to medium (Dm). In order to compare consistently both methods, the conversion of MC Dm into Dw is therefore necessary. This study aims to assess the effect of applying the conversion of MC-based Dm distributions to Dw for prostate IMRT plans generated for 6 MV photon beams. MC phantoms were created from the patient CT images using three different ramps to convert CT numbers into material and mass density: a conventional four material ramp (CTCREATE) and two simplified CT conversion ramps: (1) air and water with variable densities and (2) air and water with unit density. MC simulations were performed using the BEAMnrc code for the treatment head simulation and the DOSXYZnrc code for the patient dose calculation. The conversion of Dm to Dw by scaling with the stopping power ratios of water to medium was also performed in a post-MC calculation process. The comparison of MC dose distributions calculated in conventional and simplified (water with variable densities) phantoms showed that the effect of material composition on dose-volume histograms (DVH) was less than 1% for soft tissue and about 2.5% near and inside bone structures. The effect of material density on DVH was less than 1% for all tissues through the comparison of MC distributions performed in the two simplified phantoms considering water. Additionally, MC dose distributions were compared with the predictions from an Eclipse treatment planning system (TPS), which employed a pencil beam convolution (PBC) algorithm with Modified Batho Power Law heterogeneity correction. Eclipse PBC and MC calculations (conventional and simplified phantoms) agreed well (<1%) for soft tissues. For femoral heads, differences up to 3% were observed between the DVH for Eclipse PBC and MC calculated in conventional phantoms. The use of the CT conversion ramp of water with variable densities for MC simulations showed no dose discrepancies (0.5%) with the PBC algorithm. Moreover, converting Dm to Dw using mass stopping power ratios resulted in a significant shift (up to 6%) in the DVH for the femoral heads compared to the Eclipse PBC one. Our results show that, for prostate IMRT plans delivered with 6 MV photon beams, no conversion of MC dose from medium to water using stopping power ratio is needed. In contrast, MC dose calculations using water with variable density may be a simple way to solve the problem found using the dose conversion method based on the stopping power ratio.
Resumo:
Background: The aim was to evaluate the presence of metabolic bone disease (MBD) in patients with Crohn’s disease (CD) and to identify potential etiologic factors. Methods: The case–control study included 99 patients with CD and 56 controls with a similar age and gender distribution. Both groups had dual-energy x-ray absorptionmetry and a nutritional evaluation. Single nucleotide polymorphisms at the IL1, TNF-a, LTa, and IL-6 genes were analyzed in patients only. Statistical analysis was performed using SPSS software. Results: The prevalence of MBD was significantly higher in patients (P ¼ 0.006). CD patients with osteoporosis were older (P < 0.005), small bowel involvement and surgical resections were more frequent (P < 0.005), they more often exhibited a penetrating or stricturing phenotype (P < 0.05), duration of disease over 15 years (P < 0.005), and body mass index (BMI) under 18.5 kg/m2 (P < 0.01) were more often found. No association was found with steroid use. Patients with a Z-score < 2.0 more frequently had chronic active disease (P < 0.05). With regard to diet, low vitamin K intake was more frequent (P ¼ 0.03) and intake of total, monounsaturated, and polyunsaturated fat was higher in patients with Z-score < 2.0 (P < 0.05). With respect to genetics, carriage of the polymorphic allele for LTa252 A/G was associated with a higher risk of osteoporosis (P ¼ 0.02). Regression analysis showed that age over 40 years, chronic active disease, and previous colonic resections were independently associated with the risk of developing MBD. Conclusions: The prevalence of MBD was significantly higher in CD patients. Besides the usual risk factors, we observed that factors related to chronic active and long-lasting disease increased the risk of MBD.
Resumo:
Mestrado em Radioterapia
Resumo:
We compare the period of oscillation of an ideal simple pendulum with the period of a more 'real' pendulum constituted of a rigid sphere and a rigid slender rod. We determine the relative error in the calculation of the local acceleration of gravity if the period of the ideal pendulum is use?d instead of the period of this real pendulum. © 2014 IOP Publishing Ltd..