18 resultados para Reliability in automation

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação para a obtenção do grau de Mestre em Engenharia Electrotécnica Ramo de Energia/Automação e Eletrónica Industrial

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper presents a comparison between proportional integral control approaches for variable speed wind turbines. Integer and fractional-order controllers are designed using linearized wind turbine model whilst fuzzy controller also takes into account system nonlinearities. These controllers operate in the full load region and the main objective is to extract maximum power from the wind turbine while ensuring the performance and reliability required to be integrated into an electric grid. The main contribution focuses on the use of fractional-order proportional integral (FOPI) controller which benefits from the introduction of one more tuning parameter, the integral fractional-order, taking advantage over integer order proportional integral (PI) controller. A comparison between proposed control approaches for the variable speed wind turbines is presented using a wind turbine benchmark model in the Matlab/Simulink environment. Results show that FOPI has improved system performance when compared with classical PI and fuzzy PI controller outperforms the integer and fractional-order control due to its capability to deal with system nonlinearities and uncertainties. © 2014 IEEE.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O trabalho apresentado nesta dissertação refere-se à concepção, projecto e realização experimental de um conversor estático de potência tolerante a falhas. Foram analisados trabalhos de investigação sobre modos de falha de conversores electrónicos de potência, topologias de conversores tolerantes a falhas, métodos de detecção de falhas, entre outros. Com vista à concepção de uma solução, foram nomeados e analisados os principais modos de falhas para três soluções propostas de conversores com topologias tolerantes a falhas onde existem elementos redundantes em modo de espera. Foram analisados os vários aspectos de natureza técnica dos circuitos de potência e guiamento de sinais onde se salientam a necessidade de tempos mortos entre os sinais de disparo de IGBT do mesmo ramo, o isolamento galvânico entre os vários andares de disparo, a necessidade de minimizar as auto-induções entre o condensador DC e os braços do conversor de potência. Com vista a melhorar a fiabilidade e segurança de funcionamento do conversor estático de potência tolerante a falhas, foi concebido um circuito electrónico permitindo a aceleração da actuação normal de contactores e outro circuito responsável pelo encaminhamento e inibição dos sinais de disparo. Para a aplicação do conversor estático de potência tolerante a falhas desenvolvido num accionamento com um motor de corrente contínua, foi implementado um algoritmo de controlo numa placa de processamento digital de sinais (DSP), sendo a supervisão e actuação do sistema realizados em tempo-real, para a detecção de falhas e actuação de contactores e controlo de corrente e velocidade do motor utilizando uma estratégia de comando PWM. Foram realizados ensaios que, mediante uma detecção adequada de falhas, realiza a comutação entre blocos de conversores de potência. São apresentados e discutidos resultados experimentais, obtidos usando o protótipo laboratorial.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Este trabalho ocorre face à necessidade da empresa Helisuporte ter uma perspectiva a nível de fiabilidade das suas aeronaves. Para isso, foram traçados como objectivos de estudo a criação de uma base de dados de anomalias; identificação de sistemas e componentes problemáticos; caracterização dos mesmos, avaliar a condição de falha e, com isto, apresentar soluções de controlo de anomalias. Assim, foi desenvolvida uma metodologia que proporciona tratamento de dados com recurso a uma análise não-paramétrica, tendo sido escolhida a estatística de amostra. Esta irá permitir a identificação dos sistemas problemáticos e seus componentes anómalos. Efectuado o tratamento de dados, passamos para a caracterização fiabilística desses componentes, assumindo o tempo de operação e a vida útil específica de cada um. Esta foi possível recorrendo ao cálculo do nível de fiabilidade, MTBF, MTBUR e taxa de avarias. De modo a identificar as diferentes anomalias e caracterizar o “know-how” da equipa de manutenção, implementou-se a análise de condição de falha, mais propriamente a análise dos modos e efeitos de falha. Tendo isso em atenção, foi construído um encadeamento lógico simples, claro e eficaz, face a uma frota complexa. Implementada essa metodologia e analisados os resultados podemos afirmar que os objectivos foram alcançados, concluindo-se que os valores de fiabilidade que caracterizam alguns dos componentes das aeronaves pertencentes à frota em estudo não correspondem ao esperado e idealizado como referência de desempenho dos mesmos. Assim, foram sugeridas alterações no manual de manutenção de forma a melhorar estes índices. Com isto conseguiu-se desenvolver, o que se poderá chamar de, “fiabilidade na óptica do utilizador”.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mestrado em Contabilidade

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose – Quantitative instruments to assess patient safety culture have been developed recently and a few review articles have been published. Measuring safety culture enables healthcare managers and staff to improve safety behaviours and outcomes for patients and staff. The study aims to determine the AHRQ Hospital Survey on Patient Safety Culture (HSPSC) Portuguese version's validity and reliability. Design/methodology/approach – A missing-value analysis and item analysis was performed to identify problematic items. Reliability analysis, inter-item correlations and inter-scale correlations were done to check internal consistency, composite scores. Inter-correlations were examined to assess construct validity. A confirmatory factor analysis was performed to investigate the observed data's fit to the dimensional structure proposed in the AHRQ HSPSC Portuguese version. To analyse differences between hospitals concerning composites scores, an ANOVA analysis and multiple comparisons were done. Findings – Eight of 12 dimensions had Cronbach's alphas higher than 0.7. The instrument as a whole achieved a high Cronbach's alpha (0.91). Inter-correlations showed that there is no dimension with redundant items, however dimension 10 increased its internal consistency when one item is removed. Originality/value – This study is the first to evaluate an American patient safety culture survey using Portuguese data. The survey has satisfactory reliability and construct validity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Implementing monolithic DC-DC converters for low power portable applications with a standard low voltage CMOS technology leads to lower production costs and higher reliability. Moreover, it allows miniaturization by the integration of two units in the same die: the power management unit that regulates the supply voltage for the second unit, a dedicated signal processor, that performs the functions required. This paper presents original techniques that limit spikes in the internal supply voltage on a monolithic DC-DC converter, extending the use of the same technology for both units. These spikes are mainly caused by fast current variations in the path connecting the external power supply to the internal pads of the converter power block. This path includes two parasitic inductances inbuilt in bond wires and in package pins. Although these parasitic inductances present relative low values when compared with the typical external inductances of DC-DC converters, their effects can not be neglected when switching high currents at high switching frequency. The associated overvoltage frequently causes destruction, reliability problems and/or control malfunction. Different spike reduction techniques are presented and compared. The proposed techniques were used in the design of the gate driver of a DC-DC converter included in a power management unit implemented in a standard 0.35 mu m CMOS technology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes the efficient design of an improved and dedicated switched-capacitor (SC) circuit capable of linearizing CMOS switches to allow SC circuits to reach low distortion levels. The described circuit (SC linearization control circuit, SLC) has the advantage over conventional clock-bootstrapping circuits of exhibiting low-stress, since large gate voltages are avoided. This paper presents exhaustive corner simulation results of a SC sample-and-hold (S/H) circuit which employs the proposed and optimized circuits, together with the experimental evaluation of a complete 10-bit ADC utilizing the referred S/H circuit. These results show that the SLC circuits can reduce distortion and increase dynamic linearity above 12 bits for wide input signal bandwidths.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We are concerned with providing more empirical evidence on forecast failure, developing forecast models, and examining the impact of events such as audit reports. A joint consideration of classic financial ratios and relevant external indicators leads us to build a basic prediction model focused in non-financial Galician SMEs. Explanatory variables are relevant financial indicators from the viewpoint of the financial logic and financial failure theory. The paper explores three mathematical models: discriminant analysis, Logit, and linear multivariate regression. We conclude that, even though they both offer high explanatory and predictive abilities, Logit and MDA models should be used and interpreted jointly.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A replicate evaluation of increased micronucleus (MN) frequencies in peripheral lymphocytes of workers occupationally exposed to formaldehyde (FA) was undertaken to verify the observed effect and to determine scoring variability. May–Grünwald–Giemsa-stained slides were obtained from a previously performed cytokinesis-block micronucleus test (CBMNT) with 56 workers in anatomy and pathology laboratories and 85 controls. The first evaluation by one scorer (scorer 1) had led to a highly significant difference between workers and controls (3.96 vs 0.81 MN per 1000 cells). The slides were coded before re-evaluation and the code was broken after the complete re-evaluation of the study. A total of 1000 binucleated cells (BNC) were analysed per subject and the frequency of MN (in ‰) was determined. Slides were distributed equally and randomly between two scorers, so that the scorers had no knowledge of the exposure status. Scorer 2 (32 exposed, 36 controls) measured increased MN frequencies in exposed workers (9.88 vs 6.81). Statistical analysis with the two-sample Wilcoxon test indicated that this difference was not significant (p = 0.17). Scorer 3 (20 exposed, 46 controls) obtained a similar result, but slightly higher values for the comparison of exposed and controls (19.0 vs 12.89; p = 0.089). Combining the results of the two scorers (13.38 vs 10.22), a significant difference between exposed and controls (p = 0.028) was obtained when the stratified Wilcoxon test with the scorers as strata was applied. Interestingly, the re-evaluation of the slides led to clearly higher MN frequencies for exposed and controls compared with the first evaluation. Bland–Altman plots indicated that the agreement between the measurements of the different scorers was very poor, as shown by mean differences of 5.9 between scorer 1 and scorer 2 and 13.0 between scorer 1 and scorer 3. Calculation of the intra-class correlation coefficient (ICC) revealed that all scorer comparisons in this study were far from acceptable for the reliability of this assay. Possible implications for the use of the CBMNT in human biomonitoring studies are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper focus on a demand response model analysis in a smart grid context considering a contingency scenario. A fuzzy clustering technique is applied on the developed demand response model and an analysis is performed for the contingency scenario. Model considerations and architecture are described. The demand response developed model aims to support consumers decisions regarding their consumption needs and possible economic benefits.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper focuses on a novel formalization for assessing the five parameter modeling of a photovoltaic cell. An optimization procedure is used as a feasibility problem to find the parameters tuned at the open circuit, maximum power, and short circuit points in order to assess the data needed for plotting the I-V curve. A comparison with experimental results is presented for two monocrystalline PV modules.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper focuses on a novel formalization for assessing the five parameter modeling of a photovoltaic cell. An optimization procedure is used as a feasibility problem to find the parameters tuned at the open circuit, maximum power, and short circuit points in order to assess the data needed for plotting the I-V curve. A comparison with experimental results is presented for two monocrystalline PV modules.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the new internet remote laboratory (IRL), constructed at Mechanical Engineering Department (MED), Instituto Superior de Engenharia de Lisboa (ISEL), to teach Industrial Automation, namely electropneumatic cycles. The aim of this work was the development and implementation of a remote laboratory that was simple and effective from the user point of view, allowing access to all its functionalities through a web browser without having to install any other program and giving access to all the features that the students can find at the physical laboratory. With this goal in mind, it has been implemented a simple architecture with the new programmable logic controller (PLC) SIEMENS S7-1200, and with the aid of several free programs, programming technologies such as JavaScript, PHP and databases, it was possible to have a remote laboratory, with a simple interface, to teach industrial automation students.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

3D laser scanning is becoming a standard technology to generate building models of a facility's as-is condition. Since most constructions are constructed upon planar surfaces, recognition of them paves the way for automation of generating building models. This paper introduces a new logarithmically proportional objective function that can be used in both heuristic and metaheuristic (MH) algorithms to discover planar surfaces in a point cloud without exploiting any prior knowledge about those surfaces. It can also adopt itself to the structural density of a scanned construction. In this paper, a metaheuristic method, genetic algorithm (GA), is used to test this introduced objective function on a synthetic point cloud. The results obtained show the proposed method is capable to find all plane configurations of planar surfaces (with a wide variety of sizes) in the point cloud with a minor distance to the actual configurations. © 2014 IEEE.