6 resultados para City configuration
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
In MIMO systems the antenna array configuration in the BS and MS has a large influence on the available channel capacity. In this paper, we first introduce a new Frequency Selective (FS) MIMO framework for macro-cells in a realistic urban environment. The MIMO channel is built over a previously developed directional channel model, which considers the terrain and clutter information in the cluster, line-of-sight and link loss calculations. Next, MIMO configuration characteristics are investigated in order to maximize capacity, mainly the number of antennas, inter-antenna spacing and SNR impact. Channel and capacity simulation results are presented for the city of Lisbon, Portugal, using different antenna configurations. Two power allocations schemes are considered, uniform distribution and FS spatial water-filling. The results suggest optimized MIMO configurations, considering the antenna array size limitations, specially at the MS side.
Resumo:
Vários estudos demonstraram que os doentes com insuficiência cardíaca congestiva (ICC) têm um compromisso da qualidade de vida relacionada com a saúde (QVRS), tendo esta, nos últimos anos, vindo a tornar-se um endpoint primário quando se analisa o impacto do tratamento de situações crónicas como a ICC. Objectivos: Avaliar as propriedades psicométricas da versão portuguesa de um novo instrumento específico para medir a QVRS na ICC em doentes hospitalizados: o Kansas City Cardiomyopathy Questionnaire (KCCQ). População e Métodos: O KCCQ foi aplicado a uma amostra consecutiva de 193 doentes internados por ICC. Destes, 105 repetiram esta avaliação 3 meses após admissão hospitalar, não havendo eventos ocorridos durante este período de tempo. A idade era 64,4± 12,4 anos (entre 21 e 88), com 72,5% a pertencer ao sexo masculino, sendo a ICC de etiologia isquémica em 42%. Resultados: Esta versão do KCCQ foi sujeita a validação estatística semelhante à americana com a avaliação da fidelidade e validade. A fidelidade foi avaliada pela consistência interna dos domínios e dos somatórios, apresentando valores Alpha de Cronbach idênticos nos vários domínios e somatórios ( =0,50 a =0,94). A validade foi analisada pela convergência, pela sensibilidade às diferenças entre grupos e pela sensibilidade à alteração da condição clínica. Avaliou-se a validade convergente de todos os domínios relacionados com funcionalidade, pela relação verificada entre estes e uma medida de funcionalidade, a classificação da New York Heart Association (NYHA), tendo-se verificado correlações significativas (p<0,01), como medida para avaliar a funcionalidade em doentes com ICC. Efectuou-se uma análise de variância entre o domínio limitação física, os somatórios e as classes da NYHA, tendo-se encontrado diferenças estatisticamente significativas (F=23,4; F=36,4; F=37,4; p=0,0001), na capacidade de descriminação da gravidade da condição clínica. Foi realizada uma segunda avaliação em 105 doentes na consulta do 3º mês após a intervenção clínica, tendo-se observado alterações significativas nas médias dos domínios avaliados entre o internamento e a consulta (diferenças de 14,9 a 30,6 numa escala de 0-100), indicando que os domínios avaliados são sensíveis à mudança da condição clínica. A correlação interdimensões da qualidade de vida que compõe este instrumento é moderada, sugerindo dimensões independentes, apoiando a sua estrutura multifactorial e a adequabilidade desta medida para a sua avaliação. Conclusão: O KCCQ é um instrumento válido, sensível à mudança e específico para medir a QVRS numa população portuguesa com miocardiopatia dilatada e ICC. ABSTRACT - Several studies have shown that patients with congestive heart failure (CHF) have a compromised health-related quality of life (HRQL), and this, in recent years, has become a primary endpoint when considering the impact of treatment of chronic conditions such as CHF. Objectives: To evaluate the psychometric properties of the Portuguese version of a new specific instrument to measure HRQL in patients hospitalized for CHF: the Kansas City Cardiomyopathy Questionnaire (KCCQ). Methods: The KCCQ was applied to a sample of 193 consecutive patients hospitalized for CHF. Of these, 105 repeated the assessment 3 months after admission, with no events during this period. Mean age was 64.4±12.4 years (21-88), and 72.5% were 72.5% male. CHF was of ischemic etiology in 42% of cases. Results: This version of the KCCQ was subjected to statistical validation, with assessment of reliability and validity, similar to the American version. Reliability was assessed by the internal consistency of the domains and summary scores, which showed similar values of Cronbach alpha (0.50-0.94). Validity was assessed by convergence, sensitivity to differences between groups and sensitivity to changes in clinical condition. We evaluated the convergent validity of all domains related to functionality, through the relationship between them and a measure of functionality, the New York Heart Association (NYHA) classification. Significant correlations were found (p<0.01) for this measure of functionality in patients with CHF. Analysis of variance between the physical limitation domain, the summary scores and NYHA class was performed and statistically significant differences were found (F=23.4; F=36.4; F=37.4, p=0.0001) in the ability to discriminate severity of clinical condition. A second evaluation was performed on 105 patients at the 3-month follow-up outpatient appointment, and significant changes were observed in the mean scores of the domains assessed between hospital admission and the clinic appointment (differences from 14.9 to 30.6 on a scale of 0-100), indicating that the domains assessed are sensitive to changes in clinical condition. The correlation between dimensions of quality of life in the KCCQ is moderate, suggesting that the dimensions are independent, supporting the multifactorial nature of HRQL and the suitability of this measure for its evaluation. Conclusion: The KCCQ is a valid instrument, sensitive to change and a specific measure of HRQL in a population with dilated cardiomyopathy and CHF.
Resumo:
The first examples of low temperature N-oxy-3-aza Cope rearrangements, leading to functionalised allenes are described, where the Z-configuration of the enaminic double bond in the rearranging system proves critical.
Resumo:
Opposite enantiomers exhibit different NMR properties in the presence of an external common chiral element, and a chiral molecule exhibits different NMR properties in the presence of external enantiomeric chiral elements. Automatic prediction of such differences, and comparison with experimental values, leads to the assignment of the absolute configuration. Here two cases are reported, one using a dataset of 80 chiral secondary alcohols esterified with (R)-MTPA and the corresponding 1H NMR chemical shifts and the other with 94 13C NMR chemical shifts of chiral secondary alcohols in two enantiomeric chiral solvents. For the first application, counterpropagation neural networks were trained to predict the sign of the difference between chemical shifts of opposite stereoisomers. The neural networks were trained to process the chirality code of the alcohol as the input, and to give the NMR property as the output. In the second application, similar neural networks were employed, but the property to predict was the difference of chemical shifts in the two enantiomeric solvents. For independent test sets of 20 objects, 100% correct predictions were obtained in both applications concerning the sign of the chemical shifts differences. Additionally, with the second dataset, the difference of chemical shifts in the two enantiomeric solvents was quantitatively predicted, yielding r2 0.936 for the test set between the predicted and experimental values.
Resumo:
Amorphous glass/ZnO-Al/p(a-Si:H)/i(a-Si:H)/n(a-Si1-xCx:H)/Al imagers with different n-layer resistivities were produced by plasma enhanced chemical vapour deposition technique (PE-CVD). An image is projected onto the sensing element and leads to spatially confined depletion regions that can be readout by scanning the photodiode with a low-power modulated laser beam. The essence of the scheme is the analog readout, and the absence of semiconductor arrays or electrode potential manipulations to transfer the information coming from the transducer. The influence of the intensity of the optical image projected onto the sensor surface is correlated with the sensor output characteristics (sensitivity, linearity blooming, resolution and signal-to-noise ratio) are analysed for different material compositions (0.5 < x < 1). The results show that the responsivity and the spatial resolution are limited by the conductivity of the doped layers. An enhancement of one order of magnitude in the image intensity signal and on the spatial resolution are achieved at 0.2 mW cm(-2) light flux by decreasing the n-layer conductivity by the same amount. A physical model supported by electrical simulation gives insight into the image-sensing technique used.
Resumo:
A new inherently chiral calix[4]arene ICC 1 has been disclosed. The dissymmetry of 1 is generated from a chirality plane in the quinol moiety of a 1,3-bridged bicyclic calix[4]arene. ICC 1 has been resolved by enantioselective HPLC, and the chiroptical properties of both isolated antipodes (pS)-1 and (pR)-1 confirm their enantiomeric nature. The absolute configuration of the (pS)-1/(pR)-1 enantiomeric pair was established through time-dependent density functional theory (TDDFT) calculations of electronic circular dichroism (CD) spectra. (C) 2014 Elsevier Ltd. All rights reserved.