59 resultados para Teste de função respiratória Avaliação
Resumo:
Mestrado em Interveno Scio-Organizacional na Sade - rea de especializao: Polticas de Administrao e Gesto de Servios de Sade.
Resumo:
Mestrado em Tecnologia de Diagnstico e Interveno Cardiovascular. rea de especializao: Interveno Cardiovascular.
Resumo:
Mestrado em Tecnologia de Diagnstico e Interveno Cardiovascular. rea de especializao - Ultrassonografia Cardiovascular
Resumo:
Mestrado em Radiaes Aplicadas s Tecnologias da Sade. rea de especializao: Proteco contra Radiaes
Resumo:
Introduo Na avaliação diagnstica em mamografia, o desempenho do radiologista pode estar sujeito a erros de diagnstico. Objetivo Descrever a importncia da perceo visual na anlise da mamografia, identificando os principais fatores que contribuem para a perceo visual do radiologista e que condicionam a acuidade diagnstica. Metodologia Estudo descritivo baseado numa reviso sistemtica de literatura atravs da PubMed e da Science Direct. Foram includos 42 artigos que respeitavam, pelo menos, um dos critrios de incluso no estudo. Para a seleo das referncias foi utilizada a metodologia PRISMA, constituda por 4 fases: identificao, seleo preliminar, elegibilidade e estudos includos. Resultados Na avaliação diagnstica em mamografia, a perceo visual est intimamente relacionada com: 1) diferentes parmetros visuais e da motilidade ocular (acuidade visual, sensibilidade ao contraste e luminncia e movimentos oculares); 2) com condies de visualizao de uma imagem (iluminncia da sala e luminncia do monitor); e 3) fadiga ocular provocada pela observao diria consecutiva de imagens. Concluses A perceo visual pode ser influenciada por 3 categorias de erros observados: erros de pesquisa (leses no so fixadas pela fvea), erros de reconhecimento (leses fixadas, mas no durante o tempo suficiente) e erros de deciso (leses fixadas, mas no identificadas como suspeitas). Os estudos analisados sobre perceo visual, ateno visual e estratgia visual, bem como os estudos sobre condies de visualizao no caracterizam a função visual dos observadores. Para uma avaliação correta da perceo visual em mamografia devero ser efetuados estudos que correlacionem a função visual com a qualidade diagnstica. ABSTRACT - Introduction Diagnostic evaluation in mammography could be influenced by the radiologist performance that could be under diagnostic errors. Aims To describe the importance of radiologist visual perception in mammographic diagnostic evaluation and to identify the main factors that contribute to diagnostic accuracy. Methods In this systematic review 42 references were included based on inclusion criteria (PubMed and Science Direct). PRISMA method was used to select the references following 4 steps: identification, screening, eligibility and included references. Results Visual perception in mammography diagnostic evaluation is related with: 1) visual parameters and ocular motility (visual acuity, contrast sensitivity and luminance and ocular movements); 2) image visualization environment (room iluminance and monitor luminance); and 3) eyestrain caused by image daily consecutive observation. Conclusions Visual perception can be influenced by three errors categories: search errors (lesions are never looked at with high-resolution foveal vision), recognition errors (lesions are looked at, but not long enough to detect or recognize) and decision errors (lesions are looked at for long periods of time but are still missed). The reviewed studies concerning visual perception, visual attention, visual strategies and image visualization environment do not describe observers visual function. An accurate evaluation of visual perception in mammography must include visual function analysis.
Resumo:
Objetivo Comparar a tcnica convencional, a tcnica de energias mistas e a tcnica field-in-field com energias mistas, verificando a dose recebida nos rgos de risco e no volume alvo. Metodologia Quinze doentes com carcinoma da mama esquerda classificadas de T1-T3N0M0 foram tratadas com cirurgia conservadora da mama, seguida de radioterapia ps-operatria. Para cada doente realizaram-se 3 planeamentos dosimtricos, sendo que cada um deles diz respeito a uma das diferentes tcnicas em estudo. Atravs dos HDV gerados avaliaram-se a Dmx, Dmed, Dmn, D95%, D3% e a homogeneidade da dose no volume alvo, bem como a dose nos rgos de risco. Utilizou-se o teste de Friedman para verificar a significncia do estudo, com um intervalo de confiana de 95%. Resultados Relativamente ao pulmo esquerdo e ao corao obtiveram-se, com a tcnica field-in-field com energias mistas, doses inferiores em comparao com as outras duas tcnicas. Para a Dmx e a homogeneidade de dose no PTV, a tcnica field-in-field com energias mistas revelou-se mais eficaz, comparativamente s outras tcnicas. No entanto, verificou-se uma melhor cobertura de dose no PTV com a tcnica convencional. Consideraes finais A tcnica field-in-field com energias mistas permite uma reduo da dose nos rgos de risco, uma reduo significativa da Dmx no PTV e melhora a homogeneidade da dose, comparativamente com as outras tcnicas. Os resultados obtidos com a tcnica field-in-field com energias mistas apontam para a reduo dos efeitos secundrios provocados pelo tratamento. ABSTRACT - Purpose To compare the conventional technique, the technique of mixed energies and the technique field-in-field with mixed energies, checking the received dose in organs at risk and target volume. Methods Fifteen patients with carcinoma of the left breast classified as T1-T3N0M0 were treated with breast-conserving surgery, followed by postoperative radiotherapy. For each patient were carried out three dosimetric plannings, each one of them concerns the different techniques under study. Through the DVH generated to evaluate Dmax, Dmed, Dmin, D95%, D3% and the homogeneity of the target volume dose, well as the dose in organs at risk. We used the Friedman test to assess the significance of the study, with a confidence interval of 95%. Results For the left lung and heart were obtained with the technique field-in-field with mixed energies, lower doses compared with the other two techniques. For the Dmax and the homogeneity of the PTV dose, the technique field-in-field with mixed energies was more effective compared to other techniques. However, there was a better coverage of the PTV dose with conventional technique. Conclusions The technique field-in-field with mixed energy allows a reduction in dose for organs at risk, a significant reduction Dmax in PTV and improves the homogeneity of the dose compared with other techniques. The results obtained with the technique field-in-field with mixed energy indicate to reduce the side effects caused by the treatment.
Resumo:
Projeto de Interveno apresentado Escola Superior de Educao de Lisboa para obteno do grau de Mestre em Didtica da Lngua Portuguesa no 1. e 2. Ciclo do Ensino Bsico
Resumo:
Mestrado em Tecnologia de Diagnstico e Interveno Cardiovascular. rea de especializao: Ultrassonografia Cardiovascular.
Resumo:
Dissertao apresentada Escola Superior de Educao de Lisboa para obteno do grau de Mestre em Cincias da Educao - Especializao em Superviso em Educao
Resumo:
Dissertao apresentada Escola Superior de Educao de Lisboa no mbito do Mestrado em Ensino Especial
Resumo:
Os indivduos com idade 50 anos representam entre 65% a 82% dos casos de baixa viso e cegueira. Cerca de metade dos casos de baixa de acuidade visual so corrigveis e cerca de 1/4 so prevenveis. As causas mais frequentes so os erros de refrao (43%) e as cataratas (33%). Os idosos podem no reportar informao relacionada com queixas do foro visual, uma vez que, podem estar mais focados noutros sintomas. Objectivos: identificar a prevalncia de alteraes da função visual; identificar a prevalncia de alteraes da acuidade visual para longe e perto; identificar as alteraes da acuidade visual para longe causadas por erros refrativos atravs do buraco estenopeico; identificar alteraes da sensibilidade ao contraste, estereopsia e viso cromtica; identificar a periodicidade da avaliação oftalmolgica.
Resumo:
RESUMO: Objetivos Determinar a sensibilidade e especificidade das ponderaes Difuso (DWI) e T2 Fluid-Attenuated Inversion Recovery (FLAIR) na avaliação de leses da substncia branca (SB) e verificar em que medida se complementam, por forma a criar um conjunto de boas prticas na RM cranioenceflica de rotina. Metodologia Recorrendo-se a uma metodologia quantitativa, efetuou-se uma anlise retrospetiva da qual foram selecionados 30 pacientes, 10 sem patologia e 20 com patologia (2 com EM, 7 com Leucoencefalopatia, 6 com doena microangioptica e 5 com patologia da substncia branca indefinida). Obteve-se uma amostra de 60 imagens, nomeadamente: 30 imagens ponderadas em DWI e 30 em T2 FLAIR. Recorrendo ao programa Viewdex, trs observadores avaliaram um conjunto de imagens segundo sete critrios: visibilidade, deteo, homogeneidade, localizao, margens e dimenses da leso e capacidade de diagnstico. Com os resultados obtidos recorreu-se ao clculo de sensibilidade e especificidade pelas Curvas ROC, bem como anlise estatstica, nomeadamente, Teste-T, ndice de Concordncia Kappa e coeficiente de correlao de Pearson entre as variveis em estudo. Resultados Os resultados de sensibilidade e de especificidade obtidos para a ponderao T2 FLAIR foram superiores (0,915 e 0,038, respetivamente) aos da ponderao DWI (0,08 e 0,100, respetivamente). No se verificaram varincias populacionais significativas. Obteve-se uma elevada correlao linear entre as variveis com um valor r situado entre 0,8 e 0,99. Verificou-se tambm uma variabilidade considervel entre os observadores. Concluses Dados os baixos valores de sensibilidade e especificidade obtidos para a DWI, sugere-se que esta deva ser includa no protocolo de rotina de crnio como auxiliar no diagnstico diferencial com outras patologias.
Resumo:
Mestrado em Tecnologia de Diagnstico e Interveno Cardiovascular - rea de especializao: Ultrassonografia Cardiovascular.
Resumo:
Mestrado em Fisioterapia.
Resumo:
Introduo As funes a desempenhar pelos tcnicos de radiologia (TR) envolvem exposio ocupacional s radiaes ionizantes, podendo acarretar potenciais efeitos biolgicos. Metodologia De modo a avaliar a dose efetiva recebida pelo TR nos diferentes mtodos de estudo radiolgico em que este trabalha, procedeu-se realizao de um estudo exploratrio-descritivo. Efetuaram-se medies com dosmetros termoluminescentes em cinco valncias radiolgicas e foram aplicados questionrios aos TR para determinar o tempo total de trabalho, bem como as medidas gerais de proteo radiolgica utilizadas durante o perodo de medies. Resultados Verificou-se que as doses efetivas, calculadas por hora, foram mais elevadas na valncia de radiologia de interveno, com os dados obtidos sobre a proteo plumbnea, sendo que a valncia com menor dose efetiva calculada por hora foi a de mamografia, que apresentou um valor de medio igual a zero. Concluses Com o presente estudo conclui-se que existem diferenas de dose efetiva recebida de acordo com a função desempenhada pelo TR. Pela extrapolao dos valores calculados para doses efetivas anuais, verificou-se que os valores correspondentes a cada valncia se encontram muito abaixo do limite anual legal de 20mSv.