58 resultados para equivalent web thickness method


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Medicina Nuclear.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The conventional methods used to evaluate chitin content in fungi, such as biochemical assessment of glucosamine release after acid hydrolysis or epifluorescence microscopy, are low throughput, laborious, time-consuming, and cannot evaluate a large number of cells. We developed a flow cytometric assay, efficient, and fast, based on Calcofluor White staining to measure chitin content in yeast cells. A staining index was defined, its value was directly related to chitin amount and taking into consideration the different levels of autofluorecence. Twenty-two Candida spp. and four Cryptococcus neoformans clinical isolates with distinct susceptibility profiles to caspofungin were evaluated. Candida albicans clinical isolate SC5314, and isogenic strains with deletions in chitin synthase 3 (chs3Δ/chs3Δ) and genes encoding predicted Glycosyl Phosphatidyl Inositol (GPI)-anchored proteins (pga31Δ/Δ and pga62Δ/Δ), were used as controls. As expected, the wild-type strain displayed a significant higher chitin content (P < 0.001) than chs3Δ/chs3Δ and pga31Δ/Δ especially in the presence of caspofungin. Ca. parapsilosis, Ca. tropicalis, and Ca. albicans showed higher cell wall chitin content. Although no relationship between chitin content and antifungal drug susceptibility phenotype was found, an association was established between the paradoxical growth effect in the presence of high caspofungin concentrations and the chitin content. This novel flow cytometry protocol revealed to be a simple and reliable assay to estimate cell wall chitin content of fungi.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to evaluate the capacity of laser scanning cytometry (LSC) to detect acid-fast bacilli directly on clinical samples, a comparison between Kinyoun-stained smears analyzed under light microscopy and propidium iodide-auramine-stained smears analyzed by LSC was performed. The results were compared with those for culture on BACTEC MGIT 960. LSC is a new, reliable methodology to detect Mycobacteria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Levels of risk for future disability can be assessed with grip strength. This assessment is of fundamental importance for establishing prevention strategies. It also allows verifying relationships with functional capacity of individuals. Most studies on grip strength use the JAMAR Hydraulic dynamometer that provides the value of isometric force obtained during the performance of grip movement and is considered the “gold standard” for measurement of grip strength. However, there are different dynamometers available commercially, such as portable computerized dynamometer E-Link (Biometrics), which provides the value of maximum force (peak force) in addition to other variables as the rate of fatigue for hand strength, among others. Of our knowledge, there are no studies that allow us to accept or not and compare values obtained with both devices and perhaps use them interchangeably. The aim of this study was to evaluate the absolute agreement between the measurements of grip strength (peak force or maximum force in kg) obtained from two different devices (portable dynamometers): a computerized (E-Link, Biometrics) and one hydraulic (JAMAR).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was carried out with the aim of modeling in 2D, in plain strain, the movement of a soft cohesive soil around a pile, in order to enable the determination of stresses resulting along the pile, per unit length. The problem in study fits into the large deformations problem and can be due to landslide, be close of depth excavations, to be near of zones where big loads are applied in the soil, etc. In this study is used an constitutive Elasto-Plastic model with the failure criterion of Mohr-Coulomb to model the soil behavior. The analysis is developed considering the soil in undrained conditions. To the modeling is used the finite element program PLAXIS, which use the Updated Lagrangian - Finite Element Method (UL-FEM). In this work, special attention is given to the soil-pile interaction, where is presented with some detail the formulation of the interface elements and some studies for a better understand of his behavior. It is developed a 2-D model that simulates the effect of depth allowing the study of his influence in the stress distribution around the pile. The results obtained give an important base about how behaves the movement of the soil around a pile, about how work the finite element program PLAXIS and how is the stress distribution around the pile. The analysis demonstrate that the soil-structure interaction modeled with the UL-FEM and interface elements is more appropriate to small deformations problems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Functionally graded materials are composite materials wherein the composition of the constituent phases can vary in a smooth continuous way with a gradation which is function of its spatial coordinates. This characteristic proves to be an important issue as it can minimize abrupt variations of the material properties which are usually responsible for localized high values of stresses, and simultaneously providing an effective thermal barrier in specific applications. In the present work, it is studied the static and free vibration behaviour of functionally graded sandwich plate type structures, using B-spline finite strip element models based on different shear deformation theories. The effective properties of functionally graded materials are estimated according to Mori-Tanaka homogenization scheme. These sandwich structures can also consider the existence of outer skins of piezoelectric materials, thus achieving them adaptive characteristics. The performance of the models, are illustrated through a set of test cases. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper addresses the problem of optimal positioning of surface bonded piezoelectric patches in sandwich plates with viscoelastic core and laminated face layers. The objective is to maximize a set of modal loss factors for a given frequency range using multiobjective topology optimization. Active damping is introduced through co-located negative velocity feedback control. The multiobjective topology optimization problem is solved using the Direct MultiSearch Method. An application to a simply supported sandwich plate is presented with results for the maximization of the first six modal loss factors. The influence of the finite element mesh is analyzed and the results are, to some extent, compared with those obtained using alternative single objective optimization. (C) 2013 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present measurements and numerical simulation of a-Si:H p-i-n detectors with a wide range of intrinsic layer thickness between 2 and 10 pm. Such a large active layer thickness is required in applications like elementary particle detectors or X-ray detectors. For large thickness and depending on the applied bias, we observe a sharp peak in the spectral response in the red region near 700 nm. Simulation results obtained with the program ASCA are in agreement with the measurement and permit the explanation of the experimental data. In thick samples holes recombine or are trapped before reaching the contacts, and the conduction mechanism is fully electron dominated. As a consequence, the peak position in the spectral response is located near the optical band gap of the a-Si:H i-layer. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monte Carlo (MC) dose calculation algorithms have been widely used to verify the accuracy of intensity-modulated radiotherapy (IMRT) dose distributions computed by conventional algorithms due to the ability to precisely account for the effects of tissue inhomogeneities and multileaf collimator characteristics. Both algorithms present, however, a particular difference in terms of dose calculation and report. Whereas dose from conventional methods is traditionally computed and reported as the water-equivalent dose (Dw), MC dose algorithms calculate and report dose to medium (Dm). In order to compare consistently both methods, the conversion of MC Dm into Dw is therefore necessary. This study aims to assess the effect of applying the conversion of MC-based Dm distributions to Dw for prostate IMRT plans generated for 6 MV photon beams. MC phantoms were created from the patient CT images using three different ramps to convert CT numbers into material and mass density: a conventional four material ramp (CTCREATE) and two simplified CT conversion ramps: (1) air and water with variable densities and (2) air and water with unit density. MC simulations were performed using the BEAMnrc code for the treatment head simulation and the DOSXYZnrc code for the patient dose calculation. The conversion of Dm to Dw by scaling with the stopping power ratios of water to medium was also performed in a post-MC calculation process. The comparison of MC dose distributions calculated in conventional and simplified (water with variable densities) phantoms showed that the effect of material composition on dose-volume histograms (DVH) was less than 1% for soft tissue and about 2.5% near and inside bone structures. The effect of material density on DVH was less than 1% for all tissues through the comparison of MC distributions performed in the two simplified phantoms considering water. Additionally, MC dose distributions were compared with the predictions from an Eclipse treatment planning system (TPS), which employed a pencil beam convolution (PBC) algorithm with Modified Batho Power Law heterogeneity correction. Eclipse PBC and MC calculations (conventional and simplified phantoms) agreed well (<1%) for soft tissues. For femoral heads, differences up to 3% were observed between the DVH for Eclipse PBC and MC calculated in conventional phantoms. The use of the CT conversion ramp of water with variable densities for MC simulations showed no dose discrepancies (0.5%) with the PBC algorithm. Moreover, converting Dm to Dw using mass stopping power ratios resulted in a significant shift (up to 6%) in the DVH for the femoral heads compared to the Eclipse PBC one. Our results show that, for prostate IMRT plans delivered with 6 MV photon beams, no conversion of MC dose from medium to water using stopping power ratio is needed. In contrast, MC dose calculations using water with variable density may be a simple way to solve the problem found using the dose conversion method based on the stopping power ratio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous Monte Carlo studies have investigated the multileaf collimator (MLC) contribution to the build-up region for fields in which the MLC leaves were fully blocking the openings defined by the collimation jaws. In the present work, we investigate the same effect but for symmetric and asymmetric MLC defined field sizes (2×2, 4×4, 10×10 and 3×7 cm2). A Varian 2100C/D accelerator with 120-leaf MLC is accurately modeled fora6MVphoton beam using the BEAMnrc/EGSnrc code. Our results indicate that particles scattered from accelerator head and MLC are responsible for the increase of about 7% on the surface dose when comparing 2×2 and 10×10 cm2 fields. We found that the MLC contribution to the total build-up dose is about 2% for the 2×2 cm2 field and less than 1% for the largest fields.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de natureza científica para obtenção do grau de Mestre em Engenharia Informática e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os sistemas Computer-Aided Diagnosis (CAD) auxiliam a deteção e diferenciação de lesões benignas e malignas, aumentando a performance no diagnóstico do cancro da mama. As lesões da mama estão fortemente correlacionadas com a forma do contorno: lesões benignas apresentam contornos regulares, enquanto as lesões malignas tendem a apresentar contornos irregulares. Desta forma, a utilização de medidas quantitativas, como a dimensão fractal (DF), pode ajudar na caracterização dos contornos regulares ou irregulares de uma lesão. O principal objetivo deste estudo é verificar se a utilização concomitante de 2 (ou mais) medidas de DF – uma tradicionalmente utilizada, a qual foi designada por “DF de contorno”; outra proposta por nós, designada por “DF de área” – e ainda 3 medidas obtidas a partir destas, por operações de dilatação/erosão e por normalização de uma das medidas anteriores, melhoram a capacidade de caracterização de acordo com a escala BIRADS (Breast Imaging Reporting and Data System) e o tipo de lesão. As medidas de DF (DF contorno e DF área) foram calculadas através da aplicação do método box-counting, diretamente em imagens de lesões segmentadas e após a aplicação de um algoritmo de dilatação/erosão. A última medida baseia-se na diferença normalizada entre as duas medidas DF de área antes e após a aplicação do algoritmo de dilatação/erosão. Os resultados demonstram que a medida DF de contorno é uma ferramenta útil na diferenciação de lesões, de acordo com a escala BIRADS e o tipo de lesão; no entanto, em algumas situações, ocorrem alguns erros. O uso combinado desta medida com as quatro medidas propostas pode melhorar a classificação das lesões.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The construction industry keeps on demanding huge quantities of natural resources, mainly minerals for mortars and concrete production. The depletion of many quarries and environmental concerns about reducing the dumping of construction and demolition waste in quarries have led to an increase in the procuring and use of recycled aggregates from this type of waste. If they are to be incorporated in concrete and mortars it is essential to know their properties to guarantee the adequate performance of the end products, in both mechanical and durability-related terms. Existing regulated tests were developed for natural aggregates, however, and several problems arise when they are applied to recycled aggregates, especially fine recycled aggregates (FRA). This paper describes the main problems encountered with these tests and proposes an alternative method to determine the density and water absorption of FRA that removes them. The use of sodium hexametaphosphate solutions in the water absorption test has proven to improve its efficiency, minimizing cohesion between particles and helping to release entrained air.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivos – Demonstrar o potencial da espetroscopia (1H) por ressonância magnética na doença degenerativa discal lombar e defender a integração desta técnica na rotina clínico‑imagiológica para a precisa classificação da involução vs degenerescência dos discos L4‑L5 e L5‑S1 em doentes com lombalgia não relacionável com causa mecânica. Material e métodos – O estudo incluiu 102 discos intervertebrais lombares de 123 doentes. Foram estudados 61 discos de L4‑L5, 41 discos de L5‑S1 e 34 discos de D12‑L1. Utilizou‑se um sistema de ressonância magnética de 1,5 T e técnica monovoxel. Obtiveram‑se os rácios [Lac/Nacetyl] e [Nacetyl/(Lac+Lípidos)] e aplicou‑se a ressonância de lípidos para avaliar a bioquímica do disco com o fim de conhecer o estado de involução vs degenerescência que o suscetibilizam para a instabilidade e sobrecarga. Avaliou‑se o comportamento dos rácios e do teor lipídico dos discos L4‑L5‑S1 e as diferenças apresentadas em relação a D12‑L1. Foi também realizada a comparação entre os discos L4‑L5, L5‑S1 e D12‑L1 na ponderação T2 (T2W), segundo a classificação ajustada (1‑4) de Pfirrmann. Resultados – Verificou‑se que os rácios e o valor dos lípidos dos discos L4‑L5‑S1 apresentaram diferenças estatisticamente significativas quando relacionados com os discos D12‑L1. O rácio [Lac/Nacetyl] em L4‑L5‑S1 mostrou‑se aumentado em relação a D12‑L1 (p=0,033 para os discos com grau de involução [1+2] e p=0,004 para os discos com grau [3+4]). Estes resultados sugerem que a involução vs degenerescência dos discos nos graus mais elevados condiciona um decréscimo do pico do Lactato. O rácio [Nacetyl/(Lac+Lip)] discrimina os graus de involução [1+2] do [3+4] no nível L4‑L5, apresentando os valores dos rácios (média 0,65 e 0,5 respetivamente com p=0,04). O rácio médio de [Nacetyl/(Lac+Lip)] dos discos L4‑L5 foi 1,8 vezes mais elevado do que em D12‑L1. O espetro lipídico em L4‑L5‑S1 nos graus mais elevados não mostrou ter uma prevalência constante quanto às frequências de ressonância. Conclusão – A espetroscopia (1H) dos discos intervertebrais poderá ter aplicação na discriminação dos graus de involução vs degenerescência e representar um contributo semiológico importante em suplemento à ponderação T2 convencional. As ressonâncias de lípidos dos discos L4‑L5 e L5‑S1, involuídos ou degenerados, devem ser avaliadas em relação a D12‑L1, utilizando este valor como referência, pois este último é o nível considerado estável e com baixa probabilidade de degenerescência.