37 resultados para KNOWLEDGE ACQUISITION
Resumo:
Dissertação apresentada à Escola Superior de Educação de Lisboa para a obtenção de grau de Mestre em Didática da Língua Portuguesa no 1.º e 2.º Ciclos do Ensino Básico
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Electrónica e Telecomunicações
Resumo:
International Conference with Peer Review 2012 IEEE International Conference in Geoscience and Remote Sensing Symposium (IGARSS), 22-27 July 2012, Munich, Germany
Resumo:
Relatório Final de Estágio apresentado à Escola Superior de Dança com vista à obtenção do grau de Mestre em Ensino de Dança.
Resumo:
Purpose - To compare the image quality and effective dose applying the 10 kVp rule with manual mode acquisition and AEC mode in PA chest X-ray. Method - 68 images (with and without lesions) were acquired using an anthropomorphic chest phantom using a Wolverson Arcoma X-ray unit. These images were compared against a reference image using the 2 alternative forced choice (2AFC) method. The effective dose (E) was calculated using PCXMC software using the exposure parameters and the DAP. The exposure index (lgM provided by Agfa systems) was recorded. Results - Exposure time decreases more when applying the 10 kVp rule with manual mode (50%–28%) when compared with automatic mode (36%–23%). Statistical differences for E between several ionization chambers' combinations for AEC mode were found (p = 0.002). E is lower when using only the right AEC ionization chamber. Considering the image quality there are no statistical differences (p = 0.348) between the different ionization chambers' combinations for AEC mode for images with no lesions. Considering lgM values, it was demonstrated that they were higher when the AEC mode was used compared to the manual mode. It was also observed that lgM values obtained with AEC mode increased as kVp value went up. The image quality scores did not demonstrate statistical significant differences (p = 0.343) for the images with lesions comparing manual with AEC mode. Conclusion - In general the E is lower when manual mode is used. By using the right AEC ionising chamber under the lung the E will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the visibility of the lesions or image quality.
Resumo:
Relatório de Estágio apresentado à Escola Superior de Educação de Lisboa para obtenção de grau de mestre em Ensino do 1.º e do 2.º Ciclo do Ensino Básico
Resumo:
Relatório de Estágio apresentado à Escola Superior de Educação de Lisboa para obtenção de grau de mestre em Ensino de 1.º e 2.º Ciclos do Ensino Básico
Resumo:
Resumo I - O projecto “Piano e outros Instrumentos/orquestra” consiste na implementação do formato Piano e Orquestra em complemento às aulas individuais e aos ensaios de conjunto. O trabalho foi dirigido a um grupo de três alunos com idades de 9, 12 e 16 anos, do curso de Iniciação, Básico e Secundário da EMNSC (Escola de Música de Nossa Senhora do Cabo). Foram criados momentos distintos em cada fase. Estimulou-se o desenvolvimento de competências musicais e de estratégias metacognitivas visando a evolução dos alunos e a eficácia na realização do estudo individual. O Projecto foi criado com o objectivo de desenvolver as competências musicais, a motivação para realização do estudo individual e de grupo, o espírito e a audição crítica, o controlo dos factores psicológicos, a ansiedade, o aumento da autoconfiança, a aprendizagem, a melhoria da atitude positiva no momento da execução pública e o incremento do interesse pelas actividades relacionadas com a prática musical. A realização deste projecto visou analisar o grau de motivação, o desenvolvimento e a aquisição de competências musicais dos alunos de piano que frequentaram semanalmente aulas individuais, aulas extra de preparação, ensaios com Orquestra “Da Capo”, ensaios com a Orquestra Maior, duos com violoncelo e com canto. Um dos objectivos era comparar o grau de motivação e desenvolvimento dos alunos quando estudam obras nas aulas individuais que constituem o programa curricular e, por outro lado, quando o fazem em peças seleccionadas especificamente para este Projecto. Esta experiência visou proporcionar um conhecimento nos diversos domínios da música, uma visão diferente da funcionalidade do piano em conjunto com os outros instrumentos, a descoberta das sonoridades do piano contrastante e ao mesmo tempo, integrante com outros instrumentos, as formas de funcionamento dos instrumentos de corda, de sopro, dos assuntos relacionados com a afinação e pretendendo-se assim apurar o sentido de fazer parte integrante de um todo.
Resumo:
Relatório final apresentado à Escola Superior de Educação de Lisboa para obtenção de grau de mestre em Ensino do 1.º e 2.º Ciclos do Ensino Básico
Resumo:
Relatório de Estágio para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização em Edificações
Resumo:
Coronary artery disease (CAD) is currently one of the most prevalent diseases in the world population and calcium deposits in coronary arteries are one direct risk factor. These can be assessed by the calcium score (CS) application, available via a computed tomography (CT) scan, which gives an accurate indication of the development of the disease. However, the ionising radiation applied to patients is high. This study aimed to optimise the protocol acquisition in order to reduce the radiation dose and explain the flow of procedures to quantify CAD. The main differences in the clinical results, when automated or semiautomated post-processing is used, will be shown, and the epidemiology, imaging, risk factors and prognosis of the disease described. The software steps and the values that allow the risk of developingCADto be predicted will be presented. A64-row multidetector CT scan with dual source and two phantoms (pig hearts) were used to demonstrate the advantages and disadvantages of the Agatston method. The tube energy was balanced. Two measurements were obtained in each of the three experimental protocols (64, 128, 256 mAs). Considerable changes appeared between the values of CS relating to the protocol variation. The predefined standard protocol provided the lowest dose of radiation (0.43 mGy). This study found that the variation in the radiation dose between protocols, taking into consideration the dose control systems attached to the CT equipment and image quality, was not sufficient to justify changing the default protocol provided by the manufacturer.
Resumo:
A aquisição de competências ao nível da compreensão na leitura apresenta-se, cada vez mais, como o caminho para chegar ao conhecimento. O tipo de texto que se assume como o meio privilegiado de acesso ao conhecimento é o texto expositivo. Como tal, é importante que os textos a que os alunos têm acesso diariamente na sala de aula (nomeadamente, os textos dos manuais) sejam adequados ao desenvolvimento dessas competências. Neste estudo,analisaram-se os textos expositivos do manual de Estudo do Meio do 4.º ano mais adotado em Portugal no ano letivo 2010/2011. Em concreto, apurou-se a percentagem de textos expositivos existentes no manual, analisou-se a sua estrutura (Meyer, 1985), o tipo de questões que os acompanham, bem como as relações entre as perguntas e as respostas (Raphael, 1986, cit. em Giasson, 2000). O manual foi ainda analisado à luz do que é preconizado pelos documentos oficiais do Ministério da Educação.
Resumo:
Dissertação apresentada à Escola Superior de Comunicação Social como parte dos requisitos para obtenção de grau de mestre em Publicidade e Marketing.
Resumo:
Purpose: To compare image quality and effective dose when the 10 kVp rule is applied with manual and AEC mode in PA chest X-ray. Methods and Materials: A total of 68 images (with and without lesions) were acquired of an anthropomorphic chest phantom in a Wolverson Arcoma X-ray unit. The images were evaluated against a reference image using image quality criteria and the 2 alternative forced choice (2 AFC) method by five radiographers. The effective dose was calculated using PCXMC software using the exposure parameters and DAP. The exposure index (lgM) was recorded. Results: Exposure time decreases considerably when applying the 10 kVp rule in manual mode (50%-28%) compared to AEC mode (36%-23%). Statistical differences for effective dose between several AEC modes were found (p=0.002). The effective dose is lower when using only the right AEC ionization chamber. Considering image quality, there are no statistical differences (p=0.348) between the different AEC modes for images with no lesions. Using a higher kVp value the lgM values will also increase. The lgM values showed significant statistical differences (p=0.000). The image quality scores did not present statistically significant differences (p=0.043) for the images with lesions when comparing manual with AEC modes. Conclusion: In general, the dose is lower in the manual mode. By using the right AEC ionising chamber the effective dose will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the detectability of the lesions.
Resumo:
Applications involving biosignals, such as Electrocardiography (ECG), are becoming more pervasive with the extension towards non-intrusive scenarios helping targeting ambulatory healthcare monitoring, emotion assessment, among many others. In this study we introduce a new type of silver/silver chloride (Ag/AgCl) electrodes based on a paper substrate and produced using an inkjet printing technique. This type of electrodes can increase the potential applications of biosignal acquisition technologies for everyday life use, given that there are several advantages, such as cost reduction and easier recycling, resultant from the approach explored in our work. We performed a comparison study to assess the quality of this new electrode type, in which ECG data was collected with three types of Ag/AgCl electrodes: i) gelled; ii) dry iii) paper-based inkjet printed. We also compared the performance of each electrode when acquired using a professional-grade gold standard device, and a low cost platform. Experimental results showed that data acquired using our proposed inkjet printed electrode is highly correlated with data obtained through conventional electrodes. Moreover, the electrodes are robust to high-end and low-end data acquisition devices. Copyright © 2014 SCITEPRESS - Science and Technology Publications. All rights reserved.