60 resultados para reliability of supply
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
Secondary caries has been reported as the main reason for restoration replacement. The aim of this in vitro study was to evaluate the performance of different methods - visual inspection, laser fluorescence (DIAGNOdent), radiography and tactile examination - for secondary caries detection in primary molars restored with amalgam. Fifty-four primary molars were photographed and 73 suspect sites adjacent to amalgam restorations were selected. Two examiners evaluated independently these sites using all methods. Agreement between examiners was assessed by the Kappa test. To validate the methods, a caries-detector dye was used after restoration removal. The best cut-off points for the sample were found by a Receiver Operator Characteristic (ROC) analysis, and the area under the ROC curve (Az), and the sensitivity, specificity and accuracy of the methods were calculated for enamel (D2) and dentine (D3) thresholds. These parameters were found for each method and then compared by the McNemar test. The tactile examination and visual inspection presented the highest inter-examiner agreement for the D2 and D3 thresholds, respectively. The visual inspection also showed better performance than the other methods for both thresholds (Az = 0.861 and Az = 0.841, respectively). In conclusion, the visual inspection presented the best performance for detecting enamel and dentin secondary caries in primary teeth restored with amalgam.
Resumo:
OBJECTIVE: The aim of this study was to translate the Structured Clinical Interview for Mood Spectrum into Brazilian Portuguese, measuring its reliability, validity, and defining scores for bipolar disorders. METHOD: Questionnaire was translated (into Brazilian Portuguese) and back-translated into English. Sample consisted of 47 subjects with bipolar disorder, 47 with major depressive disorder, 18 with schizophrenia and 22 controls. Inter-rater reliability was tested in 20 subjects with bipolar disorder and MDD. Internal consistency was measured using the Kuder Richardson formula. Forward stepwise discriminant analysis was performed. Scores were compared between groups; manic (M), depressive (D) and total (T) threshold scores were calculated through receiver operating characteristic (ROC) curves. RESULTS: Kuder Richardson coefficients were between 0.86 and 0.94. Intraclass correlation coefficient was 0.96 (CI 95 % 0.93-0.97). Subjects with bipolar disorder had higher M and T, and similar D scores, when compared to major depressive disorder (ANOVA, p < 0.001). The sub-domains that best discriminated unipolar and bipolar subjects were manic energy and manic mood. M had the best area under the curve (0.909), and values of M equal to or greater than 30 yielded 91.5% sensitivity and 74.5% specificity. CONCLUSION: Structured Clinical Interview for Mood Spectrum has good reliability and validity. Cut-off of 30 best differentiates subjects with bipolar disorder vs. unipolar depression. A cutoff score of 30 or higher in the mania sub-domain is appropriate to help make a distinction between subjects with bipolar disorder and those with unipolar depression.
Resumo:
The aim of this study was to translate, validate and verify the reliability of the Body Area Scale (BAS). Participants were 386 teenagers, enrolled in a private school. Translation into Portuguese was conducted. The instrument was evaluated for internal consistency and construct validation analysis. Reproducibility was evaluated using the Wilcoxon test and the coefficient of interclass correlation. The BAS demonstrated good values for internal consistency (0.90 and 0.88) and was able to discriminate boys and girls according to nutritional state (p = 0.020 and p = 0.026, respectively). BAS scores correlated with adolescents' BMI (r = 0.14, p = 0.055; r = 0.23, p = 0.001) and WC (r =0.13, p = 0.083; r = 0.22, 0.002). Reliability was confirmed by the coefficient of inter-class correlation (0.35, p < 0.001; 0.60, p < 0.001) for boys and girls, respectively. The instrument performed well in terms of understanding and time of completion. BAS was successfully translated into Portuguese and presented good validity when applied to adolescents.
Resumo:
OBJECTIVES: to produce evidence of the validity and reliability of the Body Shape Questionnaire (BSQ) - a tool for measuring an individual's attitude towards his or her body image. METHODS: the study covered 386 young people of both sexes aged between 10 and 18 from a private school and used self-applied questionnaires and anthropometric evaluation. It evaluated the internal consistency, the discriminant validity for differences from the means, according to nutritional status (underweight, eutrophic, overweight and obese), the concurrent validity by way of Spearman's correlation coefficient between the scale and the Body Mass Index (BMI), the waist-hip circumference ratio (WHR) and the waist circumference (WC). Reliability was tested using Wilcoxon's Test, the intraclass correlation coefficient and the Bland-Altman figures. RESULTS: the BSQ displayed good internal consistency (±=0.96) and was capable of discriminating among the total population, boys and girls, according to nutritional status (p<0.001). It correlated with the BMI (r=0.41; p<0.001), WHR (r=-0.10; p=0.043) and WC (r=0.24; p<0.001) and its reliability was confirmed by intraclass correlation (r=0.91; p<0.001) for the total population. The questionnaire was easy to understand and could be completed quickly. CONCLUSIONS: the BSQ presented good results, thereby providing evidence of its validity and reliability. It is therefore recommended for evaluation of body image attitudes among adolescents.
Resumo:
OBJETIVO: Avaliar a validade do peso, estatura e Índice de Massa Corporal (IMC) referidos e sua confiabilidade para o diagnóstico do estado nutricional de adolescentes de Piracicaba. MÉTODOS: Participaram do estudo 360 adolescentes de ambos os sexos, de escolas públicas de Piracicaba, com idade entre 10 e 15 anos. Os adolescentes auto-relataram seu peso e estatura, sendo esses valores obtidos por medidas diretas, logo em seguida, pelos entrevistadores. A validade do IMC referido foi calculada segundo índices de sensibilidade, especificidade e valor preditivo positivo (VPP). Avaliou-se a concordância entre as categorias de IMC obtido por meio das medidas referidas e aferidas a partir do coeficiente kappa ponderado, coeficiente de correlação de Lin. e gráficos de Bland e Altman e Lin. RESULTADOS: Verificou-se que tanto os meninos quanto as meninas subestimaram o peso (-1,0 meninas e meninos) e a estatura (meninas -1,2 e meninos -0,8) (p < 0,001). Os valores de IMC aferidos e referidos apresentaram uma concordância moderada. A sensibilidade do IMC referido para classificar os indivíduos obesos foi maior para os meninos (87,5%), enquanto a especificidade foi maior para as meninas (92,7%). O VPP foi elevado somente para a classificação da eutrofia. CONCLUSÕES: As medidas referidas de peso e estatura de adolescentes não representam medidas válidas e, portanto, não devem ser usadas em substituição aos valores mensurados. Além disso, verificou-se que 10% dos meninos obesos e 40% das meninas obesas poderiam permanecer não identificados utilizando-se as medidas auto-referidas, confirmando a baixa validade das medidas auto-referidas.
Resumo:
We evaluated the reliability and validity of a Brazilian-Portuguese version of the Epilepsy Medication Treatment Complexity Index (EMTCI). Interrater reliability was evaluated with the intraclass correlation coefficient (ICC), and validity was evaluated by correlation of mean EMTCI scores with the following variables: number of antiepileptic drugs (AEDs), seizure control, patients` perception of seizure control, and adherence to the therapeutic regimen as measured with the Morisky scale. We studied patients with epilepsy followed in a tertiary university-based hospital outpatient clinic setting, aged 18 years or older, independent in daily living activities, and without cognitive impairment or active psychiatric disease. ICCs ranged from 0.721 to 0.999. Mean EMTCI scores were significantly correlated with the variables assessed. Higher EMTCI scores were associated with an increasing number of AEDs, uncontrolled seizures, patients` perception of lack of seizure control, and poorer adherence to the therapeutic regimen. The results indicate that the Brazilian-Portuguese EMTCI is reliable and valid to be applied clinically in the country. The Brazilian-Portuguese EMTCI version may be a useful tool in developing strategies to minimize treatment complexity, possibly improving seizure control and quality of life in people with epilepsy in our milieu. (C) 2011 Elsevier Inc. All rights reserved.
Resumo:
The objective was to determine the reliability of isokinetic strength and endurance testing in the ankle joints of patients with intermittent claudication. Twenty-three patients with peripheral artery disease (PAD) and symptoms of intermittent claudication participated in the study. Isokinetic strength and endurance testing of the ankle joint were performed in symptomatic and asymptomatic legs on 3 separate days. Intraclass coefficient correlation of peak torque (PT) and total work (TW) ranged from 0.77 to 0.92 and 0.89 to 0.96, respectively. PT and TW increased significantly and similarly in both legs from day 1 to day 2 (PT: +42 +/- 84% in the symptomatic leg and +33 +/- 51% in the asymptomatic leg, p < 0.05;TW: +38 +/- 26% in the symptomatic leg and +26 +/- 50% in the asymptomatic leg, p < 0.05). In conclusion, isokinetic strength and endurance testing in the ankle joints of patients with PAD presents reliability coefficients ranging from 0.77 to 0.96. However, strength and endurance increased between the first and the other test sessions performed on separate days, suggesting that two test sessions are necessary for the accurate evaluation of strength and endurance in patients with PAD.
Resumo:
The aim was to investigate inter-tester and intra-tester reliability and parallel reliability between a visual assessment method and a method using a pachymeter for locating the mid-point of the patella in determining the medial/lateral patella orientation. Fifteen asymptomatic subjects were assessed and the mid-point of the patella was determined by both methods on two separate occasions two weeks apart. Inter-tester reliability was obtained by ANOVA and by intraclass correlation coefficient (ICC); intra-tester reliability was obtained by a paired t-test and ICC; and parallel reliability was obtained by Pearson`s Correlation and ICC, for the measurement on the first and second evaluations. There was acceptable inter-tester agreement (p = 0.490) and reliability for the visual inspection (ICC = 0.747) and for the pachymeter (ICC = 0.716) at the second evaluation. The inter-tester reliability in the first evaluation was unacceptable (visual ICC = 0.604; pachymeter ICC = 0.612). Although there was statistical similarity between measurements for the first and second evaluations for all testers, intra-tester reliability was not acceptable for both methods: visual (examiner 1 ICC = 0.175; examiner 2 ICC = 0.189; examiner 3 ICC = 0.155) and pachymeter (examiner 1 ICC = 0.214; examiner 2 ICC = 0.246; examiner 3 ICC = 0.069). Parallel reliability gave a perfect correlation at the first evaluation (r=0.828; p<0.001) and at the second (r=0.756; p<0.001) and reliability was between acceptable and very good (ICC = [0.748-0.813]). Both visual and pachymeter methods provide reliable and similar medial/lateral patella orientation and are reliable between different examiners, but the results between the two assessments at 2 weeks` interval demonstrated an unacceptable reliability. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Purpose: Intervertebral cervical disc herniation (CDH) is a relatively common disorder that can coexist with degenerative changes to worsen cervicogenic myelopathy. Despite the frequent disc abnormalities found in asymptomatic populations, magnetic resonance imaging (MRI) is considered excellent at detecting cervical spine myelopathy (CSM) associated with disc abnormality. The objective of this study was to investigate the intra- and inter-observer reliability of MRI detection of CSM in subjects who also had co-existing intervertebral disc abnormalities. Materials and methods: Seven experienced radiologists reviewed twice the MRI of 10 patients with clinically and/or imaging determined myelopathy. MRI assessment was performed individually, with and without operational guidelines. A Fleiss Kappa statistic was used to evaluate the intra- and inter-observer agreement. Results: The study found high intra-observer percent agreement but relatively low Kappa values on selected variables. Inter-observer reliability was also low and neither observation was improved with operational guidelines. We believe that those low values may be associated with the base rate problem of Kappa. Conclusion: In conclusion, this study demonstrated high intra-observer percent agreement in MR examination for intervertebral disc abnormalities in patients with underlying cervical myelopathy, but differing levels of intra- and inter-observer Kappa agreement among seven radiologists. (c) 2007 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Axial vertebral rotation, an important parameter in the assessment of scoliosis may be identified on X-ray images. In line with the advances in the field of digital radiography, hospitals have been increasingly using this technique. The objective of the present study was to evaluate the reliability of computer-processed rotation measurements obtained from digital radiographs. A software program was therefore developed, which is able to digitally reproduce the methods of Perdriolle and Raimondi and to calculate semi-automatically the rotation degree of vertebra on digital radiographs. Three independent observers estimated vertebral rotation employing both the digital and the traditional manual methods. Compared to the traditional method, the digital assessment showed a 43% smaller error and a stronger correlation. In conclusion, the digital method seems to be reliable and enhance the accuracy and precision of vertebral rotation measurements.
Resumo:
The present study aimed to assess the reliability of intra and inter-examiner subacromial impingement index (SII) measures obtained from radiographs. Thirty-six individuals were enrolled and divided into two groups: control group, composed of 18 volunteers in good general health without shoulder problems, and a group of 18 patients with subacromial impingement syndrome (SIS). Radiographic images were taken with the dominant upper limb in neutral rotation, while the volunteers held their arm at 90A degrees of abduction in the frontal plane. The beam of radiation at 30A degrees craniocaudal inclination was used to provide an antero-posterior image view. Three blinded examiners each performed three measurements from the subacromial space (SS) and the anatomical neck of the humerus (NH). The SII was calculated as the ratio of the SS and the NH measures. The mean values of SII were compared using t-tests. The intra-class correlation coefficient (ICC) was used to assess intra- and inter-examiner reliability of the measures. The mean values of SII were greater for the control group (0.12) than for the SIS group (0.08; p = 0.0071). SII measurements showed excellent intra (0.96-0.99) and inter-examiner reliability (0.94) for both the control and SIS group. The results of this study show the potential use of the SII; a greater mean value for the control group compared to the SIS group and excellent reliability for intra- and inter-examiner measurement. Validation studies of the index should be conducted to correlate the index with clinical findings from subacromial impingement syndrome.
Resumo:
The purpose of the present study was to evaluate the intra and interday reliability of surface electromyographic amplitude values of the scapular girdle muscles and upper limbs during 3 isometric closed kinetic chain exercises, involving upper limbs with the fixed distal segment extremity on stable base of support and on a Swiss ball (relatively unstable). Twenty healthy adults performed the exercises push-up, bench-press and wall-press with different effort levels (80% and 100% maximal load). Subjects performed three maximal voluntary contractions (MVC) in muscular testing position of each muscle to obtain a reference value for root mean square (RMS) normalization. Individuals were instructed to randomly perform three isometric contraction series, in which each exercise lasted 6 s with a 2-min resting-period between series and exercises. Intra and interday reliabilities were calculated through the intraclass correlation coefficient (ICC 2.1), standard error of the measurement (SEM). Results indicated an excellent intraday reliability of electromyographic amplitude values (ICC >= 0.75). The interday reliability of normalized RMS values ranged between good and excellent (ICC 0.52-0.98). Finally, it is suggested that the reliability of normalized electromyographic amplitude values of the analyzed muscles present better values during exercises on a stable surface. However, load levels used during the exercises do not seem to have any influence on variability levels, possibly because the loads were quite similar. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
Objective To investigate whether standardization of the multiplanar view (SMV) when evaluating the uterus using three-dimensional ultrasonography (3D-US) improves intra-and interobserver reliability and agreement with regard to endometrial measurement. Methods Two-dimensional (2D) and 3D-US was used to measure endometrial thickness by two observers in 30 women undergoing assisted reproduction treatment. Endometrial volume was measured with Virtual Organ Computer-aided AnaLysis (VOCAL (TM)) in the longitudinal (A) and coronal (C) planes using an unmodified multiplanar view (UMV) and a standardized multiplanar view (SMV). Measurement reliability was evaluated by intraclass correlation coefficient (ICC) and agreement was examined using Bland-Altman plots with limits of agreement (LoA). The ease of outlining the endometrial-myometrial interface was compared between the A-and C-planes using subjective assessment. Results Endometrial volume measurements using the SMV and A-plane were more reliable (intra-and interobserver ICCs, 0.979 and 0.975, respectively) than were measurements of endometrial thickness using 2D-US (intra-and interobserver ICCs, 0.742 and 0.702, respectively) or 3D-US (intra-and interobserver ICCs, 0.890 and 0.784, respectively). The LoAs were narrower for SMV than for UMV. Reliability and agreement were not much different between the A- and C-planes. However the observers agreed that delineating the endometrial-myometrial interface using the A-plane was easier (first and second observer, 50.0 and 46.7%, respectively) or `comparable` (50 and 53.3%, respectively), but never more difficult than using the C-plane. Conclusions Endometrial volume measurements are more reliable than endometrial thickness measurements and are best performed using SMV and the A-plane. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.
Resumo:
Background. Play is an indication of a children`s development. Purpose. Organize a culturally adapt the Child-Initiated Pretend Play Assessment to Brazilian population. Method. Translation and cultural adaptation procedures consisted of translation, synthesis, back translation, author`s approval, and pretest of the assessment. For the pretest, 14 typically developing children were assessed. Was evaluated the use of play materials, duration of the assessment, and reliability. Findings. Play materials and duration of the assessment were appropriate for Brazilian children. Analysis of intra-rater reliability showed good agreement ranging from 0.90 to 1.00. Inter-rater reliability showed good to moderate agreement for five items ranging from 0.76 to 0.59. Four items showed chance to poor agreement (rho = -0.13 to 0.50). Implications. Results of the pretest indicate the Brazilian version of the ChIPPA is potentially useful for Brazilian children. ChIPPA training in Portuguese in Brazil with play observation feedback is recommended to improve inter-rater reliability.
Resumo:
BACKGROUND: Comparative genomic hybridization (CGH) is a valuable alternative to fluorescence in situ hybridization (FISH) for preimplantation genetic screening (PGS) because it allows full karyotype analysis. However, this approach requires the cryopreservation of biopsied embryos until results are available. The aim of this study is to reduce the hybridization period of CGH, in order to make this short-CGH technique suitable for PGS of Day-3 embryos, avoiding the cryopreservation step. METHODS: Thirty-two fibroblasts from six aneuploid cell lines (Coriell) and 48 blastomeres from 10 Day-4 embryos, discarded after PGS by FISH with 9 probes (9-chr-FISH), were analysed by short-CGH. A reanalysis by the standard 72 h-CGH and FISH using telomeric probes was performed when no concordant results between short-CGH and FISH diagnosis were observed. The short-CGH was subsequently applied in a clinical case of advanced maternal age. RESULTS: In 100% of the fibroblasts analysed, the characteristic aneuploidies of each cell line were detected by short-CGH. The results of the 48 blastomeres screened by short-CGH were supported by both 72 h-CGH results and FISH reanalysis. The chromosomes most frequently involved in aneuploidy were 22 and 16, but aneuploidies for the other chromosomes, excepting 1, 10 and 13, were also detected. Forty-one of the 94 aneuploid events observed (43.6%) corresponded to chromosomes which are not analysed by 9-chr-FISH. CONCLUSIONS: We have performed a preliminary validation of the short-CGH technique, including one clinical case, suggesting this approach may be applied to Day-3 aneuploidy analysis, thereby avoiding embryo cryopreservation and perhaps helping to improve implantation rate after PGS.