31 resultados para X-RAYS: INDIVIDUALS: 1RXS J141256.0 792204

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The aim of this study was to evaluate the genotoxic effects of X-rays on epithelial gingival cells during panoramic dental radiography using a differentiated protocol for the micronucleus test. Methods: 40 healthy individuals who underwent this procedure for diagnostic purposes on request from their dentists agreed to participate in this study. All of them answered a questionnaire before the examination. Epithelial gingival cells were obtained from the keratinized mucosa of the upper dental arcade by gentle scraping with a cervical brush immediately before exposure and 10 days later. Cytological preparations were stained according to the Feulgen-Rossenbeck reaction, counterstained with fast green 1% for 1 min and analysed under a light microscope. Micronuclei, nuclear projections (broken eggs) and degenerative nuclear alterations (pyknosis, karyolysis, karyorrhexis and condensed chromatin) were scored. Results: The frequency of micronuclei was significantly higher after exposure (P < 0.05), as were frequencies of nuclear alterations indicate of apoptosis (P < 0.001). Conclusions: These results indicate that X-ray radiation emitted during panoramic dental radiography induces a genotoxic effect on epithelial gingival cells that increases the frequency of chromosomal damage and nuclear alterations indicative of apoptosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

[Ba(1-x)Y(2x/3)](Zr(0.25)Ti(0.75))O(3) powders with different yttrium concentrations (x = 0, 0.025 and 0.05) were prepared by solid state reaction. These powders were analyzed by X-ray diffraction (XRD). Fourier transform Raman scattering (FT-RS), Fourier transform infrared (FT-IR) and X-ray absorption near-edge (XANES) spectroscopies. The optical properties were investigated by means of ultraviolet-visible (UV-vis) absorption spectroscopy and photoluminescence (PL) measurements. Even with the addition of yttrium, the XRD patterns revealed that all powders crystallize in a perovskite-type cubic structure. FT-RS and FT-IR spectra indicated that the presence of [YO(6)] clusters is able to change the interaction forces between the O-Ti-O and O-Zr-O bonds. XANES spectra were used to obtain information on the off-center Ti displacements or distortion effects on the [TiO(6)] clusters. The different optical band gap values estimated from UV-vis spectra suggested the existence of intermediary energy levels (shallow or deep holes) within the band gap. The PL measurements carried out with a 350 nm wavelength at room temperature showed that all powders present typical broad band emissions in the blue region. (C) 2010 Elsevier Masson SAS. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Community-acquired pneumonia (CAP) is a leading cause of childhood death. There are few published reports of radiographic findings among children with severe CAP. Objective: To describe chest X-ray (CXR) findings and assess association between these radiographic findings and pneumococcal isolation in children with severe CAP. Methods: A prospective, multicenter, observational study was conducted in 12 centers in Argentina, Brazil, and the Dominican Republic. Children aged 3-59 months, hospitalized with severe pneumonia, were included. On admission, blood and pleural effusion cultures were performed. Streptococcus pneumoniae was identified according to standard procedures in the respective national reference laboratory. Chest X-rays were taken on admission and read before the culture results were reported. Results: Out of 2,536 enrolled patients, 283 (11.2%) had S. pneumoniae isolated, in 181 cases (7.1%) from blood. The follow radiographic patterns were observed: alveolar infiltrate (75.2%), pleural effusion (15.6%), and interstitial infiltrate (9.2%). Overall, pleural effusion was associated with pneumococcal isolation and pneumococcal bacteremia (P < 0.001). Infiltrates were unilateral (78.7%) or bilateral (21.3%), right-sided (76%) or left-sided (24%), in the lower lobe (53.6%) or the upper lobe (46.4%). Multivariate analysis including patients with affection of only one lobe showed that upper lobe affection and pleural effusion were associated with pneumococcal isolation (OR 1.8, 95% CI, 1.3-2.7; OR 11.0, 95% CI, 4.6-26.8, respectively) and with pneumococcal bacteremia (OR 1.7, 95% CI, 1.2-2.6; OR 3.1, 95% CI, 1.2-8.0, respectively). Conclusions: Three-quarters of the patients studied had alveolar infiltrates. Upper lobe compromising and pleural effusion were associated with pneumococcal invasive disease. Pediatr Pulmonol. 2010; 45:1009-1013. (C) 2010 Wiley-Liss, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The aim of the present study is to evaluate the use of anorganic bovine bone (ABB) associated with a collagen membrane (CM) for a sinus graft by means of clinical, histologic, and radiographic parameters in cases with bone availability <= 7 mm. A preliminary evaluation consisted of a clinical examination, computed tomography (CT), and a panoramic x-ray. Methods: Ninety-two patients requiring bilateral sinus grafts and 222 requiring unilateral procedures (total: 406 sinuses) participated in this study. A total of 1,025 implants were placed in the grafted sinuses. A total of 118 implants were placed simultaneously with the sinus graft (one stage), and 907 implants were placed in a subsequent surgery (two stages), 6 to 12 months after the graft was performed. In seven cases, a biopsy was harvested for histomorphometric analysis. Recall appointments were scheduled every 6 months, and panoramic and periapical x-rays were required every year for 3 years. Results: Among 1,025 implants, 19 were lost (survival rate: 98.1%). The difference in survival rates for implants placed in native bone: <= 3 mm (98.1%), >3 to <= 5 mm (98.6%), and >5 to <= 7 mm (97.0%) was not statistically significant (P = 0.3408). The survival rates for implants with rough and machined surfaces (98.6% and 97.0%, respectively) were not statistically significant (P = 0.0840). The histomorphometric analysis showed new bone formation (39.0% +/- 12%), marrow space (52.9% +/- 9.3%), and residual ABB (8% +/- 2.7%). Conclusion: Our results indicated that 1,025 implants placed in sinuses grafted exclusively with ABB combined with CM led to an excellent and predictable survival rate of 98.1%. J Periodontol 2009;80:1920-1927.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have analyzed XMM-Newton archive data for five clusters of galaxies (redshifts 0.223-0.313) covering a wide range of dynamical states, from relaxed objects to clusters undergoing several mergers. We present here temperature maps of the X-ray gas together with a preliminary interpretation of the formation history of these clusters. (c) 2007 COSPAR. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Extensive spectral observations of eta Carinae over the last cycle, and particularly around the 2003.5 low-excitation event, have been obtained. The variability of both narrow and broad lines, when combined with data taken from two earlier cycles, reveal a common and well-defined period. We have combined the cycle lengths derived from the many lines in the optical spectrum with those from broad-band X-rays, optical and near-infrared observations, and obtained a period length of P(pres) = 2022.7 +/- 1.3 d. Spectroscopic data collected during the last 60 yr yield an average period of P(avg) = 2020 +/- 4 d, consistent with the present-day period. The period cannot have changed by more than Delta P/P = 0.0007 since 1948. This confirms the previous claims of a true, stable periodicity, and gives strong support to the binary scenario. We have used the disappearance of the narrow component of He I 6678 to define the epoch of the Cycle 11 minimum, T(0) = JD 245 2819.8. The next event is predicted to occur on 2009 January 11 (+/- 2 d). The dates for the start of the minimum in other spectral features and broad-bands are very close to this date, and have well-determined time-delays from the He I epoch.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Primary beam spectra were obtained for an X-ray industrial equipment (40-150 kV), and for a clinical mammography apparatus (25-35 kV) from beams scattered at angles close to 90 degrees, measured with a CdTe Compton spectrometer. Actual scattering angles were determined from the Compton energy shift of characteristic X-rays or spectra end-point energy. Evaluated contribution of coherent scattering amounts to more than 15% of fluence in mammographic beams. This technique can be used in clinical environments. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study presents a comparison of the X-ray transmission through microsized and nanosized materials. For this purpose CuO nanoparticles, with 13.4 nm average grain size, and CuO microparticles, with a mean particle size of 56 mu m, were incorporated separately to beeswax in a concentration of 5%. Results show that the transmission through the above material plates with microsized and nanosized CuO was almost the same for X-ray beams generated at 60 and 102 kV tube voltages. However, for the radiation beams generated at 26 and 30 kV tube voltages the X-rays are more attenuated by the nanostructured CuO plates by a factor of at least 14%. Results suggest that the difference in the low energy range may be due to the higher number of particles/gram in the plates designed with CuO nanoparticles and due to the grain size effect on the X-ray transmission. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In order to validate the Geant4 toolkit for dosimetry applications, simulations were performed to calculate conversion coefficients h(10, alpha) from air kerma free-in-air to personal dose equivalent Hp(10, a). The simulations consisted of two parts: the production of X-rays with radiation qualities of narrow and wide spectra, and the interaction of radiation with ICRU tissue-equivalent and ISO water slab phantoms. The half-value layers of the X-ray spectra obtained by simulation were compared with experimental results. Mean energy, spectral resolution, half-value layers and conversion coefficients were compared with ISO reference values. The good agreement between results from simulation and reference data shows that the Geant4 is suitable for dosimetry applications which involve photons with energies in the range of ten to a few hundreds of keV. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Grossular is one of six members of silicate Garnet group. Two samples GI and GII have been investigated concerning their luminescence thermally stimulated (TL). EPR and optical absorption and the measurements were carried out to find out whether or not same point defects are responsible for all three properties. Although X-rays diffraction analysis has shown that both GI and GII have practically the same crystal structure of a standard grossular crystal, they presented different behavior in many aspects. The TL glow curve shape, TL response to radiation dose, the effect of annealing at high temperatures before irradiation, the dependence of UV bleaching parameters on peak temperature, all of them differ going from GI to GII. The EPR signals around g = 2.0 as well as at g = 4.3 and 6.0 have much larger intensity in GI than in GII. Very high temperature (> 800 degrees C annealing causes large increase in the bulk background absorption in GI, however, only very little in GII. In the cases of EPR and optical absorption, the difference in their behavior can be attributed to Fe3+ ions; however, in the TL case one cannot and the cause was not found as yet. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe how the method of detection of delayed K x-rays produced by the electron capture decay of the residual nuclei can be a powerful tool in the investigation of the effect of the breakup process on the complete fusion (CF) cross-section of weakly bound nuclei at energies close to the Coulomb barrier. This is presently one of the most interesting subjects under investigation in the field of low-energy nuclear reactions, and the difficult experimental task of separating CF from the incomplete fusion (ICF) of one of the breakup fragments can be achieved by the x-ray spectrometry method. We present results for the fusion of the (9)Be + (144)Sm system. Copyright (c) 2008 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Data collected by the Pierre Auger Observatory through 31 August 2007 showed evidence for anisotropy in the arrival directions of cosmic rays above the Greisen-Zatsepin-Kuz`min energy threshold, 6 x 10(19) eV. The anisotropy was measured by the fraction of arrival directions that are less than 3.1 degrees from the position of an active galactic nucleus within 75 Mpc (using the Veron-Cetty and Veron 12th catalog). An updated measurement of this fraction is reported here using the arrival directions of cosmic rays recorded above the same energy threshold through 31 December 2009. The number of arrival directions has increased from 27 to 69, allowing a more precise measurement. The correlating fraction is (38(-6)(+7))%, compared with 21% expected for isotropic cosmic rays. This is down from the early estimate of (69-(+11)(13))%. The enlarged set of arrival directions is examined also in relation to other populations of nearby extragalactic objects: galaxies in the 2 Microns All Sky Survey and active galactic nuclei detected in hard X-rays by the Swift Burst Alert Telescope. A celestial region around the position of the radiogalaxy Cen A has the largest excess of arrival directions relative to isotropic expectations. The 2-point autocorrelation function is shown for the enlarged set of arrival directions and compared to the isotropic expectation. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To evaluate the effect of monensin on the performance of growing cattle under different environmental temperatures, 24 male calves (81.9 +/- 7.7 kg mean weight and 100 days old) were distributed in a 2 x 2 factorial arrangement, contrasting 0 or 85 mg monensin/animal per day at 24.3 or 33.2 degrees C (environmental temperatures). Monensin supplementation increased weight gain (P=0.036), improved feed efficiency (P=0.040), increased ruminal concentrations of volatile fatty acids (VFA; P=0.003) and decreased the molar proportion of butyrate (P=0.034); all effects irrespective of environmental temperatures. A temperature-dependent monensin effect was detected on nitrogen retention (P=0.018) and N retained:N absorbed ratio (P=0.012). Animals fed monensin retained higher N amounts than those of the non-supplemented ones when the environmental temperature was 33.2 degrees C. Environmental temperature and monensin supplementation showed an interaction effect on urine N concentration (P=0.003). Temperature did not affect N excretion in monensin-fed animals, but increased N excretion in the non-supplemented ones. Monensin increased the crude protein (CP) digestibility (P=0.094) for

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To test the effect of monensin on the mineral balance of growing cattle under different environmental temperatures, 24 male steers were assigned in a 2 x 2 factorial arrangement, contrasting 0 and 85 mg monensin/animal per day at 24.3 and 33.2 degrees C (environmental temperatures). Monensin effect was directly modulated by the environmental temperature: it increased apparent retentions of P (P=0.066), Na (P=0.005) and K (P=0.003), at the higher temperature and decreased these apparent retentions at the lower temperature, as compared with non-supplemented animals. Monensin increased fecal Ca (P=0.037), and urinary P (P=0.002), Na (P=0.003), K (P=0.014), Mg (P=0.051) and Zn (P=0.091), with higher concentrations of these minerals in animals held at 24.3 degrees C and lower concentrations in those at 33.2 degrees C, as compared with non-supplemented animals. Monensin decreased serum Mg (P=0.001) and increased serum Zn (P=0.071) in animals at 33.2 degrees C and increased serum Mg and decreased serum Zn at 24.3 degrees C. Irrespective of temperature, monensin increased both apparent absorption (P=0.058) and apparent retention (P=0.093) of P, and also urine Cu (P=0.085). Environmental temperature modulated monensin effects on mineral balance. Monensin increased apparent retention of several minerals in animals under heat stress. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present results of a sensitive Chandra X-ray observation and Spitzer mid-infrared (mid-IR) observations of the IR cluster lying north of the NGC 2071 reflection nebula in the Orion B molecular cloud. We focus on the dense cluster core known as NGC 2071-IR, which contains at least nine IR sources within a 40 `` x 40 `` region. This region shows clear signs of active star formation including powerful molecular outflows, Herbig-Haro objects, and both OH and H(2)O masers. We use Spitzer Infrared Array Camera (IRAC) images to aid in X-ray source identification and to determine young stellar object (YSO) classes using mid-IR colors. Spitzer IRAC colors show that the luminous source IRS 1 is a class I protostar. IRS 1 is believed to be driving a powerful bipolar molecular outflow and may be an embedded B-type star or its progenitor. Its X-ray spectrum reveals a fluorescent Fe emission line at 6.4 keV, arising in cold material near the protostar. The line is present even in the absence of large flares, raising questions about the nature of the ionizing mechanism responsible for producing the 6.4 keV fluorescent line. Chandra also detects X-ray sources at or near the positions of IRS 2, IRS 3, IRS 4, and IRS 6 and a variable X-ray source coincident with the radio source VLA 1, located just 2 `` north of IRS 1. No IR data are yet available to determine a YSO classification for VLA 1, but its high X-ray absorption shows that it is even more deeply embedded than IRS 1, suggesting that it could be an even younger, less-evolved protostar.