Resumo:

Thyristor-based onload tap-changing ac voltage stabilizers are cheap and robust. They have replaced most mechanical tap-changers in low voltage applications from 300 VA to 300 M. Nevertheless, this replacement hardily applies to tap-changers associated to transformers feeding medium-voltage lines (typically 69 kV primary, 34.5 kV line, 10 MVA) which need periodical maintenance of contacts and oil. The Electric Power Research Institute (EPRI) has studied the feasibility of this replacement. It detected economical problems derived from the need for series association of thyristors to manage the high voltages involved, and from the current overload developed under line fault. The paper reviews the configurations used in that field and proposes new solutions, using a compensating transformer in the main circuit and multi-winding coils in the commutating circuit, with reduced overload effect and no series association of thyristors, drastically decreasing their number and rating. The stabilizer can be installed at any point of the line and the electronic circuit can be fixed to ground. Subsequent works study and synthesize several commutating circuits in detail.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A photometric procedure for the determination of ClO(-) in tap water employing a miniaturized multicommuted flow analysis setup and an LED-based photometer is described. The analytical procedure was implemented using leucocrystal violet (LCV; 4,4', 4 ''-methylidynetris (N, N-dimethylaniline), C(25)H(31)N(3)) as a chromogenic reagent. Solenoid micropumps employed for solutions propelling were assembled together with the photometer in order to compose a compact unit of small dimensions. After control variables optimization, the system was applied for the determination of ClO(-) in samples of tap water, and aiming accuracy assessment samples were also analyzed using an independent method. Applying the paired t-test between results obtained using both methods, no significant difference at the 95% confidence level was observed. Other useful features include low reagent consumption, 2.4 mu g of LCV per determination, a linear response ranging from 0.02 up to 2.0 mg L(-1) ClO(-), a relative standard deviation of 1.0% (n = 11) for samples containing 0.2 mg L(-1) ClO(-), a detection limit of 6.0 mu g L(-1) ClO(-), a sampling throughput of 84 determinations per hour, and a waste generation of 432 mu L per determination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: In the tephritids Ceratitis, Bactrocera and Anastrepha, the gene transformer provides the memory device for sex determination via its auto-regulation; only in females is functional Tra protein produced. To date, the isolation and characterisation of the gene transformer-2 in the tephritids has only been undertaken in Ceratitis, and it has been shown that its function is required for the female-specific splicing of doublesex and transformer pre-mRNA. It therefore participates in transformer auto-regulatory function. In this work, the characterisation of this gene in eleven tephritid species belonging to the less extensively analysed genus Anastrepha was undertaken in order to throw light on the evolution of transformer-2. Results: The gene transformer-2 produces a protein of 249 amino acids in both sexes, which shows the features of the SR protein family. No significant partially spliced mRNA isoform specific to the male germ line was detected, unlike in Drosophila. It is transcribed in both sexes during development and in adult life, in both the soma and germ line. The injection of Anastrepha transformer-2 dsRNA into Anastrepha embryos caused a change in the splicing pattern of the endogenous transformer and doublesex pre-mRNA of XX females from the female to the male mode. Consequently, these XX females were transformed into pseudomales. The comparison of the eleven Anastrepha Transformer-2 proteins among themselves, and with the Transformer-2 proteins of other insects, suggests the existence of negative selection acting at the protein level to maintain Transformer-2 structural features. Conclusions: These results indicate that transformer-2 is required for sex determination in Anastrepha through its participation in the female-specific splicing of transformer and doublesex pre-mRNAs. It is therefore needed for the auto-regulation of the gene transformer. Thus, the transformer/transfomer-2 > doublesex elements at the bottom of the cascade, and their relationships, probably represent the ancestral state ( which still exists in the Tephritidae, Calliphoridae and Muscidae lineages) of the extant cascade found in the Drosophilidae lineage ( in which tra is just another component of the sex determination gene cascade regulated by Sex-lethal). In the phylogenetic lineage that gave rise to the drosophilids, evolution co-opted for Sex-lethal, modified it, and converted it into the key gene controlling sex determination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the current work a Green Analytical Chemistry (GAC) procedure for photometric determination of orthophosphate in river water at mu g L-1 concentration level is described. The flow system module and the LED-based photometer were assembled together to constitute a compact unit in order to allow that a flow cell with optical path-length of 100mm was coupled to them. The photometric procedure based on the molybdenum blue method was implemented employing the multicommuted flow injection analysis approach, which provided facilities to allow reduction of reagent consumption and as well as waste generation. Aiming to prove the usefulness of the system, orthophosphate in river and tap waters was determined. Accuracy was ascertained by spiking samples with orthophosphate solution yielding recoveries ranging from 96% up to 107%. Other profitable features such as a wide linear response range between 10 to 800 mu g L-1 [image omitted]; a detection limit (3 sigma criterion) of 2.4 mu g L-1 [image omitted]; a relative standard deviation (n=7) of 2% using a typical water sample with concentration of 120 mu g L-1 [image omitted]; reagent consumption of 3.0mg ammonium molybdate, 0.3mg hydrazine sulfate, and 0.03mg stannous chloride per determination; a waste generation of 2.4mL per determination; and a sampling throughput of 20 determination per hours were also achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A modular superconducting fault current limiter (SFCL) consisting of 16 elements was constructed and tested in a 220 V line for a fault current between 1 kA to 7.4 kA. The elements are made up of second generation (2G) YBCO-coated conductor tapes with stainless steel reinforcement. For each element four tapes were electrically connected in parallel with effective length of 0.4 m per element, totaling 16 elements connected in series. The evaluation of SFCL performance was carried out under DC and AC tests. The DC test was performed through pulsed current tests and its recovery characteristics under load current were analysed by changing the shunt resistor value. The AC test performed using a 3 MVA/220 V/60 Hz transformer has shown the current limiting ratio achieved a factor higher than 10 during fault of up to five cycles without conductor degradation. The measurement of the voltage for each element during the AC test showed that in this modular SFCL the quench is homogeneous and the transition occurs similarly in all the elements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The power transformer is a piece of electrical equipment that needs continuous monitoring and fast protection since it is very expensive and an essential element for a power system to perform effectively. The most common protection technique used is the percentage differential logic, which provides discrimination between an internal fault and different operating conditions. Unfortunately, there are some operating conditions of power transformers that can affect the protection behavior and the power system stability. This paper proposes the development of a new algorithm to improve the differential protection performance by using fuzzy logic and Clarke`s transform. An electrical power system was modeled using Alternative Transients Program (ATP) software to obtain the operational conditions and fault situations needed to test the algorithm developed. The results were compared to a commercial relay for validation, showing the advantages of the new method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An efficient expert system for the power transformer condition assessment is presented in this paper. Through the application of Duval`s triangle and the method of the gas ratios a first assessment of the transformer condition is obtained in the form of a dissolved gas analysis (DGA) diagnosis according IEC 60599. As a second step, a knowledge mining procedure is performed, by conducting surveys whose results are fed into a first Type-2 Fuzzy Logic System (T2-FLS), in order to initially evaluate the condition of the equipment taking only the results of dissolved gas analysis into account. The output of this first T2-FLS is used as the input of a second T2-FLS, which additionally weighs up the condition of the paper-oil system. The output of this last T2-FLS is given in terms of words easily understandable by the maintenance personnel. The proposed assessing methodology has been validated for several cases of transformers in service. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel methodology to assess the risk of power transformer failures caused by external faults, such as short-circuit, taking the paper insulation condition into account, is presented. The risk index is obtained by contrasting the insulation paper condition with the probability that the transformer withstands the short-circuit current flowing along the winding during an external fault. In order to assess the risk, this probability and the value of the degree of polymerization of the insulating paper are regarded as inputs of a type-2 fuzzy logic system (T2-FLS), which computes the fuzzy risk level. A Monte Carlo simulation has been used to find the survival function of the currents flowing through the transformer winding during a single-phase or a three-phase short-circuit. The Roy Billinton Test System and a real power system have been used to test the results. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Micro-tools offer significant promise in a wide range of applications Such as cell Manipulation, microsurgery, and micro/nanotechnology processes. Such special micro-tools consist of multi-flexible structures actuated by two or more piezoceramic devices that must generate output displacements and forces lit different specified points of the domain and at different directions. The micro-tool Structure acts as a mechanical transformer by amplifying and changing the direction of the piezoceramics Output displacements. The design of these micro-tools involves minimization of the coupling among movements generated by various piezoceramics. To obtain enhanced micro-tool performance, the concept of multifunctional and functionally graded materials is extended by, tailoring elastic and piezoelectric properties Of the piezoceramics while simultaneously optimizing the multi-flexible structural configuration using multiphysics topology optimization. The design process considers the influence of piezoceramic property gradation and also its polarization sign. The method is implemented considering continuum material distribution with special interpolation of fictitious densities in the design domain. As examples, designs of a single piezoactuator, an XY nano-positioner actuated by two graded piezoceramics, and a micro-gripper actuated by three graded piezoceramics are considered. The results show that material gradation plays an important role to improve actuator performance, which may also lead to optimal displacements and coupling ratios with reduced amount of piezoelectric material. The present examples are limited to two-dimensional models because many of the applications for Such micro-tools are planar devices. Copyright (c) 2008 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Differences between women and men have been documented for both diagnostic testing and treatment in cardiology. This analysis evaluates whether low-density lipoprotein cholesterol (LDL-C) success rates according to current guidelines and high-density lipoprotein cholesterol (HDL-C) levels differ by gender in the L-TAP 2 population. Methods Patients aged >= 20 years with dyslipidemia on stable lipid-lowering therapy were assessed in 9 countries between September 2006 and April 2007. Low-density lipoprotein cholesterol goal attainment by cardiovascular risk level and region and determinants of low HDL-C were compared between genders. Results Of 9,955 patients (45.3% women) evaluated, women had a significantly lower overall LDL-C success rate than men (71.5% vs 73.7%, P = .014), due entirely to the difference in the high-risk/coronary heart disease (CHD) group (LDL-C goal <100 mg/dL, 62.6% vs 70.6%, P < .0001) Among CHD patients with >= 2 additional risk factors, only 26.7% of women and 31.5% of men (P = .021) attained the optional LDL-C goal of <70 mg/dL. High-density lipoprotein cholesterol was <50 mg/dL in 32.2% of women and <40 mg/dL in 26.8% of men (P < .0001), including 38.2% of women and 29.8% of men in the high risk/CHD group (P < .0001). Predictors of low HDL-C in women included diabetes, smoking, waist circumference, and hypertension. Conclusions Cholesterol treatment has, improved substantially since the original L-TAP a decade ago, when only 39% of women attained their LDL-C goal. However, high-risk women are undertreated compared to men, and a substantial opportunity remains to reduce their cardiovascular risk. (Am Heart J 2009; 158:860-6.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the present substudy of the Lipid Treatment Assessment Project 2 was to assess dual C-reactive protein (CRP) and low-density lipoprotein (LDL) cholesterol goal attainment across a spectrum of low-, moderate-, and high-risk patients with dyslipidemia in 8 countries in North America, Latin America, Europe, and Asia. Of the 9,518 patients studied overall, 45% were women, 64% had hypertension, 31% had diabetes, 14% were current smokers, 60% were high risk, and 79% were taking a statin. The median CRP level was 1.5 mg/L (interquartile range 0.2 to 2.8). On multivariate analysis, higher CRP levels were associated with older age, female gender, hypertension, current smoking, greater body mass index, larger waist circumference, LDL cholesterol level, and triglyceride/high-density lipoprotein cholesterol ratio. In contrast, being from Asia or taking a statin was associated with lower levels. Across all risk groups, 59% of patients attained the CRP target of <2 mg/L, and 33% had <1 mg/L. Overall, 44% of patients attained both their National Cholesterol Education Program Adult Treatment Panel III LDL cholesterol target and a CRP level of <2 mg/L, but only 26% attained their LDL cholesterol target and a CRP level of <1 mg/L. In the very high-risk group with coronary heart disease and >= 2 risk factors, only 19% attained both their LDL cholesterol goal and a CRP level of <2 mg/L and 12% their LDL cholesterol goal and a CRP level of <1 mg/L. In conclusion, with current treatment, most dyslipidemic patients do not reach the dual CRP and LDL cholesterol goals. Smoking cessation, weight reduction, and the greater use of more potent statins at higher doses might be able to improve these outcomes. (C) 2011 Elsevier Inc. All rights reserved. (Am J Cardiol 2011;107:1639-1643)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: This analysis of the Lipid Treatment Assessment Project 2 population compared lipid goal attainment by diabetes and metabolic syndrome status. Research design and methods: Dyslipidaemic patients aged >= 20 years on stable lipid lowering therapy had their lipid levels determined once during enrolment at investigation sites in nine countries between September 2006 and April 2007. Achievement of low-density lipoprotein (LDL) cholesterol success, triglycerides < 150 mg/dl (1.7 mmol/l), and high-density lipoprotein (HDL) cholesterol success (> 40 mg/dl [1.0 mmol/l] in men or > 50 mg/dl [1.3 mmol/l] in women) was compared using logistic regression. Results: A total of 9955 patients were evaluated. Patients with diabetes, compared with those without diabetes, had lower achievement of LDL cholesterol goals (according to National Cholesterol Education Program Adult Treatment Panel [NCEP ATP] III guidelines; 67% vs. 75%), triglycerides < 150 mg/dl (55% vs. 64%), and HDL cholesterol success (61% vs. 74%; p < 0.0001 for all comparisons). The significantly lower lipid goal attainment in patients with diabetes was consistent across participating world regions. Patients with metabolic syndrome, compared with those without metabolic syndrome, had lower achievement of NCEP ATP III LDL cholesterol goals (69% vs. 76%), triglycerides < 150 mg/dl (36% vs. 83%), and HDL cholesterol success (49% vs. 89%; p < 0.0001 for all comparisons). As the number of metabolic syndrome components increased, lipid success rates progressively decreased (p < 0.0001 for LDL cholesterol success, triglycerides < 150 mg/dl, and HDL cholesterol success). Conclusions: This analysis indicates that despite their increased cardiovascular risk, patients with diabetes or metabolic syndrome remain undertreated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: There is only limited knowledge on how the quantification of valvular regurgitation by color Doppler is affected by changing blood viscosity. This study was designed to evaluate the effect of changing blood viscosity on the vena contracta width using an in vitro model of valvular insufficiency capable of providing ample variation in the rate and stroke volume. Methods: We constructed a pulsatile flow model filled with human blood at varying hematocrit (15%, 35%, and 55%) and corresponding blood viscosity (blood/water viscosity: 2.6, 4.8, 9.1) levels in which jets were driven through a known orifice (7 mm(2)) into a 110 mL compliant receiving chamber (compliance: 2.2 mL/mmHg) by a pulsatile pump. In addition, we used variable pump stroke volumes (5, 7.5, and 10 mL) and rates (40, 60, and 80 ppm). Vena contracta region was imaged using a 3.5 MHz transducer. Pressure and volume in the flow model were kept constant during each experimental condition, as well as ultrasound settings. Results: Blood viscosity variation in the experimental range did not induce significant changes in vena contracta dimensions. Also, vena contracta width did not change from normal to low hematocrit and viscosity levels. A very modest increase only in vena contracta dimension was observed at very high level of blood viscosity when hematocrit was set to 55% . Pump rate, in the evaluated range, did not influence vena contracta width. These results in controlled experimental settings suggest that the vena contracta is an accurate quantitative method for quantifying valvular regurgitation even when this condition is associated with anemia, a frequent finding in patients with valvular heart disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The Gow-Gates technique is said to have several advantages over traditional techniques to achieve mandibular nerve anesthesia; however, its routine use is quite limited, mainly due to complications during visual alignment of reference landmarks. The purpose of this study was to verify the validity and accuracy of a new method to reach the injection site. Material and Methods: Fifteen magnetic resonance images were captured. Distances from the ideal injection point in the condylar neck (puncture ideal) to the injection points located in the a and 0 plane intersection (Puncture Gow-Gates and puncture modified) were measured and compared. Results: Positive and significant (P <= .003) Pearson correlations between landmarks and injection points confirmed the validity of the modified technique. Paired t test showed that the segment line puncture ideal-puncture modified, 5.17 mm, was 3 times shorter (P < .001) than the segment line puncture ideal-puncture Gow-Gates, 17.91 mm. As calculated by linear regression, establishing the injection point of the modified technique depended only on the anteroposterior and lateromedial condyle positions. Conclusions: The modified technique proved to be valid and precise and has a determined and an effective injection site. (C) 2009 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 67:2609-2616, 2009

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eating attitudes are defined as beliefs. thoughts, feelings and behaviors towards food. Bulimia nervosa (BN) is ail eating disorder, in which the eating, attitudes are Seriously disturbed. Studies that evaluated nutritional aspects of BN focus mainly oil food intake, dietary restriction and binge eating. while the follow-up Studies evaluate mainly clinical symptoms. The objective of this study was to evaluate eating attitudes of patients with BN. during and after cognitive-behavioral intervention. Thirty nine (39) BN female patients received cognitive behavioral treatment with a Multidisciplinary team and had eating attitudes assessed by a questionnaire developed for this research. Frequencies of the attitudes assessed were compared at baseline. after 12 weeks and 24 weeks of treatment. After treatment, patients had less distorted beliefs about food, less guilty after eating ""forbidden"" foods and they felt more tranquil while caring outside home. Other negative behaviors, as dietary restriction, the desire of not cat, being angry when feeling hungry and using the food to relive stress. persisted. Eating attitudes of patients with BN are hard to be changed in a short-term. More attention to this disease`s component and new approaches to treatment are needed in order to have a better recovery.