Green Chemistry-Sensitive Analytical Procedure for Photometric Determination of Orthophosphate in River and Tap Water by Use of a Simple LED-Based Photometer


Autoria(s): SILVA, Milton B.; BORGES, Sivanildo S.; PERDIGAO, Sheila R. W.; REIS, Boaventura F.
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

18/10/2012

18/10/2012

2009

Resumo

In the current work a Green Analytical Chemistry (GAC) procedure for photometric determination of orthophosphate in river water at mu g L-1 concentration level is described. The flow system module and the LED-based photometer were assembled together to constitute a compact unit in order to allow that a flow cell with optical path-length of 100mm was coupled to them. The photometric procedure based on the molybdenum blue method was implemented employing the multicommuted flow injection analysis approach, which provided facilities to allow reduction of reagent consumption and as well as waste generation. Aiming to prove the usefulness of the system, orthophosphate in river and tap waters was determined. Accuracy was ascertained by spiking samples with orthophosphate solution yielding recoveries ranging from 96% up to 107%. Other profitable features such as a wide linear response range between 10 to 800 mu g L-1 [image omitted]; a detection limit (3 sigma criterion) of 2.4 mu g L-1 [image omitted]; a relative standard deviation (n=7) of 2% using a typical water sample with concentration of 120 mu g L-1 [image omitted]; reagent consumption of 3.0mg ammonium molybdate, 0.3mg hydrazine sulfate, and 0.03mg stannous chloride per determination; a waste generation of 2.4mL per determination; and a sampling throughput of 20 determination per hours were also achieved.

CNPq (Conselho Nacional de Desenvolvimento Cientifico e Tecnologico do Brasil)

CAPES (Coordenadenacao de Aperfeicoamento de Pessoal de Nivel Superior)

Identificador

SPECTROSCOPY LETTERS, v.42, n.6/Jul, p.356-362, 2009

0038-7010

http://producao.usp.br/handle/BDPI/17033

10.1080/00387010903185744

http://dx.doi.org/10.1080/00387010903185744

Idioma(s)

eng

Publicador

TAYLOR & FRANCIS INC

Relação

Spectroscopy Letters

Direitos

restrictedAccess

Copyright TAYLOR & FRANCIS INC

Palavras-Chave #LED-based photometer #long pathlength flow cell #multicommuted flow injection analysis #orthophosphate and water #spectrophotometry #NATURAL-WATERS #FLOW-INJECTION #EXPLOITING MULTICOMMUTATION #SPECTROPHOTOMETRIC DETERMINATION #SYSTEM #CELL #PHOSPHATE #SEWAGE #STATE #TOOL #Spectroscopy
Tipo

article

original article

publishedVersion