6 resultados para Duhamel Convolution
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
A procedure is proposed for the determination of the residence time distribution (RTD) of curved tubes taking into account the non-ideal detection of the tracer. The procedure was applied to two holding tubes used for milk pasteurization in laboratory scale. Experimental data was obtained using an ionic tracer. The signal distortion caused by the detection system was considerable because of the short residence time. Four RTD models, namely axial dispersion, extended tanks in series, generalized convection and PER + CSTR association, were adjusted after convolution with the E-curve of the detection system. The generalized convection model provided the best fit because it could better represent the tail on the tracer concentration curve that is Caused by the laminar velocity profile and the recirculation regions. Adjusted model parameters were well cot-related with the now rate. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Purpose: Transanal endorectal pull-through (TEPT) has drastically changed the treatment of Hirschsprung`s disease (HD). A short follow-up of children Submitted to TEPT reveals results that are similar to the classic transabdominal pull-through procedures. However, few reports compare the late results of TEPT with transabdominal pull-through procedures with respect to complication rates and the fecal continence. The aims of the present work are to describe some technical refinements that we introduced in the procedure and to compare the short and long-term outcome of TEPT with the outcomes of a group of patients with HD who previously underwent the Duhamel procedure. Methods: Thirty-five patients who underwent TEPT were prospectively studied and compared to a group of 29 patients who were treated with colostomy followed by a classical Duhamel pull-through. The main modifications introduced in the TEPT group were no preoperative colon preparation, operation conducted under general anesthesia in addition to regional sacral anesthesia, use of only one purse-string Suture in the rectal mucosa before transanal submucosal dissection, and no use of retractors and electrocautery during file submucosal dissection. Results: The most frequent early complications of TEPT group were perineal dermatitis (22.8%) and anastomotic strictures (8.6%). The comparison with patients who underwent Duhamel procedure revealed no difference in the incidence of preoperative enterocolitis, the patients of the TEPT group were younger at the time of diagnosis and of surgery, they had shorter operating times, and they began oral feeding more quickly after the operation. The incidence of wound infection was lower in the TEPT group. Moreover, the TEPT and Duhamel groups showed no difference in the incidences of mortality, postoperative partial continence, and total incontinence. Although the incidences of complete continence and postoperative enterocolitis were not different, a tendency to the increased incidence in the TEPT group was observed. Conclusions: This study further supports the technical advantages, the simplicity, and the decreased incidence of complications of a primary TEPT procedure when compared to a classical form of pull-through. Sonic technical refinements are described, and no preoperative colon preparation was necessary for the patients studied here. The results show that the long-term outcomes of the modified TEPT procedure are generally better than those obtained with classical approaches. Published by Elsevier Inc.
Resumo:
The arguments for the usage of the names Gnathoplax, Roeboexodon, R. geryi, and R. guyanensis are revised. Based on the literature and museum specimens, we recommend that the neotype of Exodon guyanensis should be considered valid; that the genus Gnathoplax should be considered an objective junior synonym of Roeboexodon; and that Roeboexodon geryi should be considered an objective junior synonym of Exodonguyanensis.
Resumo:
The objective was to study the flow pattern in a plate heat exchanger (PHE) through residence time distribution (RTD) experiments. The tested PHE had flat plates and it was part of a laboratory scale pasteurization unit. Series flow and parallel flow configurations were tested with a variable number of passes and channels per pass. Owing to the small scale of the equipment and the short residence times, it was necessary to take into account the influence of the tracer detection unit on the RID data. Four theoretical RID models were adjusted: combined, series combined, generalized convection and axial dispersion. The combined model provided the best fit and it was useful to quantify the active and dead space volumes of the PHE and their dependence on its configuration. Results suggest that the axial dispersion model would present good results for a larger number of passes because of the turbulence associated with the changes of pass. This type of study can be useful to compare the hydraulic performance of different plates or to provide data for the evaluation of heat-induced changes that occur in the processing of heat-sensitive products. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
The classical approach for acoustic imaging consists of beamforming, and produces the source distribution of interest convolved with the array point spread function. This convolution smears the image of interest, significantly reducing its effective resolution. Deconvolution methods have been proposed to enhance acoustic images and have produced significant improvements. Other proposals involve covariance fitting techniques, which avoid deconvolution altogether. However, in their traditional presentation, these enhanced reconstruction methods have very high computational costs, mostly because they have no means of efficiently transforming back and forth between a hypothetical image and the measured data. In this paper, we propose the Kronecker Array Transform ( KAT), a fast separable transform for array imaging applications. Under the assumption of a separable array, it enables the acceleration of imaging techniques by several orders of magnitude with respect to the fastest previously available methods, and enables the use of state-of-the-art regularized least-squares solvers. Using the KAT, one can reconstruct images with higher resolutions than was previously possible and use more accurate reconstruction techniques, opening new and exciting possibilities for acoustic imaging.
Resumo:
A positive summability trigonometric kernel {K(n)(theta)}(infinity)(n=1) is generated through a sequence of univalent polynomials constructed by Suffridge. We prove that the convolution {K(n) * f} approximates every continuous 2 pi-periodic function f with the rate omega(f, 1/n), where omega(f, delta) denotes the modulus of continuity, and this provides a new proof of the classical Jackson`s theorem. Despite that it turns out that K(n)(theta) coincide with positive cosine polynomials generated by Fejer, our proof differs from others known in the literature.