13 resultados para Computer Software
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
Introduction: Current advances in frame modeling and computer software allow stereotactic procedures to be performed with great accuracy and minimal risk of neural tissue or vascular injury. Case Report: In this report we associate a previously described minimally invasive stereotactic technique with state-of-the-art 3D computer guidance technology to successfully treat a 55-year-old patient with an arachnoidal cyst obstructing the aqueduct of Sylvius. We provide 1 detailed technical information and discuss how this technique deals with previous limitations for stereotactic manipulation of the aqueductal region. We further discuss current advances in neuroendoscopy for treating obstructive hydrocephalus and make comparisons with our proposed technique. Conclusion: We advocate that this technique is not only capable of treating this pathology but it also has the advantages to enable reestablishment of physiological CSF flow thus preventing future brainstem compression by cyst enlargement.
Resumo:
This study describes the normal morphology and morphometry of the dorsal cutaneous branch of the ulnar nerve (DCBU) in humans. Fourteen nerves of eight donors were prepared by conventional techniques for paraffin and epoxy resin embedding. Semiautomatic morphometric analysis was performed by means of specific computer software. Histograms of the myelinated and unmyelinated fiber population and the G-ratio distribution of fibers were plotted. Myelinated fiber density per nerve varied from 5,910 to 10,166 fibers/mm(2), with an average of 8,170 +/- 393 fibers/mm(2). The distribution was bimodal with peaks at 4.0 and 9.5 mu m. Unmyelinated fiber density per nerve varied from 50,985 to 127,108, with an average of 78,474 +/- 6, 610 fibers/mm(2), with a unimodal distribution displaying a peak at 0.8 mu m. This study thus adds information about the fascicles and myelinated and unmyelinated fibers of DCBU nerves in normal people, which may be useful in further studies concerning ulnar nerve neuropathies, mainly leprosy neuropathy.
Resumo:
Despite numerous literature reports on the morphometry of the myelinated fibers of phrenic nerves in rats, a systematic study of the longitudinal and lateral symmetry of the unmyelinated fibers morphometry is not available. In this study, we have undertaken ultrastructural and morphometric studies of the phrenic nerve in adult rats, assessing two different levels (proximal and distal) from both right and left sides. Phrenic nerves of adult male Wistar rats were prepared for epoxy resin embedding and transmission electron microscopy. Morphometric analysis was performed with the aid of computer software, which took into consideration the unmyelinated fiber number, density, area, and diameter, as well as ratio between myelinated and unmyelinated fibers, and the percentage of the fascicular area occupied by the myelinated and unmyelinated fibers. Comparison of data from proximal and distal segments on the same side and from the same levels between sides was performed. Differences were considered significant when P < 0.05. The most important finding is that morphometric parameters of the phrenic nerve unmyelinated fibers in adult rats are both longitudinally and laterally symmetric. This study adds important morphometric information about the unmyelinated fibers of the phrenic nerves in adult rats for proximal and distal levels on both sides of the animal. Anat Rec, 292:513-517, 2009. (C) 2008 Wiley-Liss, Inc.
Resumo:
Purpose: The purpose of this study was to evaluate the area and volume of bone available for grafting in a donor retromolar region using computed tomography (CT). Materials and Methods: Ten patients previously scanned by multislice CT were selected for evaluation. Images from partially and completely dentate patients at least 18 years of age were included in the study; those from patients with impacted or erupted third molars or intrabony lesions in the study area were not included. Computer software with appropriate tools was used to handle the images. Two calibrated observers made measurements separately. Safety margins in relation to the lingual cortex, the base of mandible, and the alveolar canal were established in each cross-section of the CTs. Measurements were done by using cross-sectional views, and the results were calculated after three-dimensional reconstruction, providing area and volume data. Results: The mean area of bone available for grafting was 8.12 cm(2) ( range, 0.00 to 13.60 cm(2)) and 8.32 cm(2) ( range, 0.00 to 14.30 cm(2)) for observers 1 and 2, respectively. Mean available bone volume for grafting was 0.79 cm(3) ( range, 0.00 to 1.50 cm(3)) for observer 1 and 0.85 cm(3) ( range, 0.00 to 1.60 cm(3)) for observer 2. Interobserver analysis showed substantial agreement. Conclusion: The retromolar region showed a wide variety of anatomic differences among patients. Three-dimensional multislice CT allows reproducible measurements of the area and volume of the retromolar region. Int J Oral Maxillofac Implants 2010; 25: 374-378
Resumo:
The objective was to evaluate the influence of dental metallic artefacts on implant sites using multislice and cone-beam computed tomography techniques. Ten dried human mandibles were scanned twice by each technique, with and without dental metallic artefacts. Metallic restorations were placed at the top of the alveolar ridge adjacent to the mental foramen region for the second scanning. Linear measurements (thickness and height) for each cross-section were performed by a single examiner using computer software. All mandibles were analysed at both the right and the left mental foramen regions. For the multislice technique, dental metallic artefact produced an increase of 5% in bone thickness and a reduction of 6% in bone height; no significant differences (p > 0.05) were detected when comparing measurements performed with and without metallic artefacts. With respect to the cone-beam technique, dental metallic artefact produced an increase of 6% in bone thickness and a reduction of 0.68% in bone height. No significant differences (p > 0.05) were observed when comparing measurements performed with and without metallic artefacts. The presence of dental metallic artefacts did not alter the linear measurements obtained with both techniques, although its presence made the location of the alveolar bone crest more difficult.
Resumo:
Objective. The aim of this study was to compare Profile .04 taper series 29 instruments and hand files for gutta-percha removal. Study design. Twenty maxillary central incisors with a single straight canal were instrumented and filled. The teeth were divided into 2 groups of 10 specimens each, according to gutta-percha removal techniques: Group 1- Profile series 29 and Group 2- hand files and solvent. The amount of time for gutta-percha removal and the number of fractured instruments were evaluated. Radiographs were taken and the teeth were grooved longitudinally and split. The area of residual debris was measured using computer software. Results. The time for filling material removal was significantly shorter when Profile series 29 was used (P = .00). Regarding cleanliness, there were no statistical differences in the teeth halves evaluations (P = .05). Hand instruments cleaned the canals significantly better than Profiles, in the radiographic analysis considering the whole canal. Overall, the radiographic analysis showed a smaller percentage of residual debris than the teeth halves analysis. Conclusion. The Profile series 29 instruments proved to be faster than hand instruments in removing root filling materials; however, hand instruments yielded better root canal cleanliness. Some residual debris was not visualized by radiographs. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: e46-e50)
Resumo:
Objective The purpose of this study was to evaluate the retention force of an O-ring attachment system in different inclinations to the ideal path of insertion, using devices to compensate angulations. Material and methods Two implants were inserted into an aluminum base, and ball attachments were screwed to implants. Cylinders with O-rings were placed on ball attachments and connected to the test device using positioners to compensate implant angulations (0 degrees, 7 degrees, and 14 degrees). Plexiglass bases were used to simulate implant angulations. The base and the test device were positioned in a testing apparatus, which simulated insertion/removal of an overdenture. A total of 2900 cycles, simulating 2 years of overdenture use, were performed and 36 O-rings were tested. The force required for each cycle was recorded with computer software. Longitudinal sections of ball attachment-positioner-cylinder with O-rings of each angulation were obtained to analyze the relationship among them, and O-ring sections tested in each angulation were compared with an unused counterpart. A mixed linear model was used to analyze the data, and the comparison was performed by orthogonal contrasts (alpha=0.05). Results At 0 degrees, the retention force decreased significantly over time, and the retention force was significantly different in all comparisons, except from 12 to 18 months. When the implants were positioned at 7 degrees, the retention force was statistically different at 0 and 24 months. At 14 degrees, significant differences were found from 6 and 12 to 24 months. Conclusions Within the limitations of this study, it was concluded that O-rings for implant/attachments perpendicular to the occlusal plane were adequately retentive over the first year and that the retentive capacity of O-ring was affected by implant inclinations despite the proposed positioners. To cite this article:Rodrigues RCS, Faria ACL, Macedo AP, Sartori IAM, de Mattos MGC, Ribeiro RF. An in vitro study of non-axial forces upon the retention of an O-ring attachment.Clin. Oral Impl. Res. 20, 2009; 1314-1319.doi: 10.1111/j.1600-0501.2009.01742.x.
Resumo:
This paper presents SMarty, a variability management approach for UML-based software product lines (PL). SMarty is supported by a UML profile, the SMartyProfile, and a process for managing variabilities, the SMartyProcess. SMartyProfile aims at representing variabilities, variation points, and variants in UML models by applying a set of stereotypes. SMartyProcess consists of a set of activities that is systematically executed to trace, identify, and control variabilities in a PL based on SMarty. It also identifies variability implementation mechanisms and analyzes specific product configurations. In addition, a more comprehensive application of SMarty is presented using SEI's Arcade Game Maker PL. An evaluation of SMarty and related work are discussed.
Resumo:
Support for interoperability and interchangeability of software components which are part of a fieldbus automation system relies on the definition of open architectures, most of them involving proprietary technologies. Concurrently, standard, open and non-proprietary technologies, such as XML, SOAP, Web Services and the like, have greatly evolved and been diffused in the computing area. This article presents a FOUNDATION fieldbus (TM) device description technology named Open-EDD, based on XML and other related technologies (XLST, DOM using Xerces implementation, OO, XMIL Schema), proposing an open and nonproprietary alternative to the EDD (Electronic Device Description). This initial proposal includes defining Open-EDDML as the programming language of the technology in the FOUNDATION fieldbus (TM) protocol, implementing a compiler and a parser, and finally, integrating and testing the new technology using field devices and a commercial fieldbus configurator. This study attests that this new technology is feasible and can be applied to other configurators or HMI applications used in fieldbus automation systems. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
This paper presents the proposal for a reference model for developing software aimed at small companies. Despite the importance of that represent the small software companies in Latin America, the fact of not having its own standards, and able to meet their specific, has created serious difficulties in improving their process and also in quality certification. In this sense and as a contribution to better understanding of the subject they propose a reference model and as a means to validate the proposal, presents a report of its application in a small Brazilian company, committed to certification of the quality model MPS.BR.
Resumo:
Axial vertebral rotation, an important parameter in the assessment of scoliosis may be identified on X-ray images. In line with the advances in the field of digital radiography, hospitals have been increasingly using this technique. The objective of the present study was to evaluate the reliability of computer-processed rotation measurements obtained from digital radiographs. A software program was therefore developed, which is able to digitally reproduce the methods of Perdriolle and Raimondi and to calculate semi-automatically the rotation degree of vertebra on digital radiographs. Three independent observers estimated vertebral rotation employing both the digital and the traditional manual methods. Compared to the traditional method, the digital assessment showed a 43% smaller error and a stronger correlation. In conclusion, the digital method seems to be reliable and enhance the accuracy and precision of vertebral rotation measurements.
Resumo:
Purpose: The aim of this research was to assess the dimensional accuracy of orbital prostheses based on reversed images generated by computer-aided design/computer-assisted manufacturing (CAD/CAM) using computed tomography (CT) scans. Materials and Methods: CT scans of the faces of 15 adults, men and women older than 25 years of age not bearing any congenital or acquired craniofacial defects, were processed using CAD software to produce 30 reversed three-dimensional models of the orbital region. These models were then processed using the CAM system by means of selective laser sintering to generate surface prototypes of the volunteers` orbital regions. Two moulage impressions of the faces of each volunteer were taken to manufacture 15 pairs of casts. Orbital defects were created on the right or left side of each cast. The surface prototypes were adapted to the casts and then flasked to fabricate silicone prostheses. The establishment of anthropometric landmarks on the orbital region and facial midline allowed for the data collection of 31 linear measurements, used to assess the dimensional accuracy of the orbital prostheses and their location on the face. Results: The comparative analyses of the linear measurements taken from the orbital prostheses and the opposite sides that originated the surface prototypes demonstrated that the orbital prostheses presented similar vertical, transversal, and oblique dimensions, as well as similar depth. There was no transverse or oblique displacement of the prostheses. Conclusion: From a clinical perspective, the small differences observed after analyzing all 31 linear measurements did not indicate facial asymmetry. The dimensional accuracy of the orbital prostheses suggested that the CAD/CAM system assessed herein may be applicable for clinical purposes. Int J Prosthodont 2010;23:271-276.