78 resultados para Complications: accidental injection

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim To report clinical complications (pain, necrotic gingival tissue and bone sequestration) resulting from accidental injection of sodium hypochlorite. Summary Root canal treatment is a routine clinical procedure with few reported complications. Sodium hypochlorite (NaOCl) is commonly used as an irrigant during the procedure because of its tissue-dissolving, antibacterial and lubricating properties. This paper presents a case in which accidental injection of sodium hypochlorite into the lingual gingiva of a female patient caused gingival and bone necrosis. Surgical intervention was required. Key learning points Sodium hypochlorite is dangerous if injected into the tissues. The presentation of sodium hypochlorite in glass, anaesthetic type cartridges is potentially dangerous, and should be condemned. All healthcare workers should check carefully the contents of any syringe before injecting into patients.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Sodium hypochlorite solution is toxic to vital tissues, causing severe effects if extruded during endodontic treatment. This paper presents a report on the tissue damage related to inadvertent extrusion of concentrated sodium hypochlorite solution during root canal treatment. A 65-year-old woman was referred with moderate pain, ecchymosis, and severe swelling of the right side of the face. These symptoms appeared immediately after a root canal treatment of the maxillary right canine, which had been started 21 hours earlier. It was diagnosed as air emphysema related to sodium hypochlorite solution extravasation during the endodontic treatment. To avoid this, an initial radiograph should be taken to determine the correct canal working length and confirm root canal integrity. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: e46-e49)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: During the past 15 years, polymethylmethacrylate has been used as a synthetic permanent filler for soft-tissue augmentation. Methods: This. article reports 32 cases of complications seen at Hospital das Clinicas, Faculty of Medicine, University of Sao Paulo, for procedures performed elsewhere. Results: The average age of the patients was 43.6 years (range, 22 to 70 years). Twenty-five patients were women. Sixteen injection procedures were performed by certified plastic surgeons, nine by dermatologists, two by urologists, and one by a nonphysician. Complications were classified into five groups according to main presentation as follows: tissue necrosis (five cases), an acute complication that can be related to technical mistakes but that can also be dependent on patient factors or caused by local infection; granuloma (10 cases), which usually presents as a subacute complication 6 to 12 months after the procedure; chronic inflammatory reactions (10 cases), which usually occur years later and can be related to a triggering event, Such as another operation or infection in the area that was injected (these reactions are immunogenic in origin and may have cyclic periods of activation and remission); chronic inflammatory reaction in the lips (six cases), which may be present with severe symptoms, especially with lymphedema, because of mobility of the lip; and infections (one case), which are rare but possible complications after filling procedures. Conclusions: Polymethylmethacrylate filler complications, despite being rare, are often permanent and difficult or even impossible to treat. Safety guidelines should be observed when considering use of polymethylmethacrylate for augmentation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction and objectives: Recurrent transplant pyelonephritis (RTP) secondary to vesico-ureteral reflux (VUR) to the transplant kidney (KTx) remains a significant cause of infectious complications with impact on patient and graft outcomes. Our objective was to verify the safety and efficacy of transurethral injection of Durasphere (R) to relieve RTP secondary to VUR after renal transplantation. Patients and methods: Between June 2004 and July 2008, eight patients with RTP (defined as two or more episodes of pyelonephritis after transplantation) and VUR to the KTx were treated with subureteral injections of Durasphere (R). The mean age at surgery was 38.8 +/- 13.8 yr (23-65). The patients were followed regularly every six months. The mean interval between the KTx and the treatment was 76 +/- 74.1 (10-238 months). The mean follow-up was 22.3 +/- 16.1 months (8-57 months). Results: Six patients (75%) were free of pyelonephritis during a mean period of follow-up of 23.2 +/- 17.1 months (8-57 months). Two of them had no VUR and four cases presented with G II VUR (pre-operative G IV three cases and one case G III). In one case, symptomatic recurrent cystitis made a second treatment necessary. This patient remained free of infections for three yr after the first treatment and for 18 months after the second treatment. Of the remaining two patients, one had six episodes of RTP before treatment in a period of three yr and only two episodes after treatment in two yr of follow-up. The last case had a new episode of pyelonephritis five months after treatment. Conclusions: Transurethral injection therapy with Durasphere (R) is a safe and effective minimally invasive treatment option for KTx patients with recurrent RTP. A second treatment seems to be necessary in some cases.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Despite modern reanimation surgical techniques, facial paralysis presents with functional and aesthetic deficits. We evaluated facial symmetry after treating with botulinum toxin the healthy side of the face of 25 patients with long-standing facial paralysis who had previously been treated by surgical methods, with 6 months follow-up. Evaluation consisted of a clinical score, the two subscales of the Facial Disability Index, and surface electromyography. The mean botulinum toxin dose was 38 +/- A 5 U (range = 15-69 U). The clinical score showed significant reduction of asymmetry of 48.4% at 1 month and 16.8% after 6 months. The initial result was a consequence of reduced motion on the treated side combined with better motion on the paralyzed side. At 6 months, the treated side returned to basal scores. The residual effect seen in symmetry was due to an increase (18%) of motion in the paralyzed side. There was a significant decrease in the action potential of muscles on the nonparalyzed side 1 month post injection but completely reverted after 6 months. The Physical Function Index increased, but not significantly. The Social/Well-Being Function Index showed a significant increase at 6 months compared to pretreatment. The proposed treatment improved facial symmetry for up to 6 months. Even after the end of the clinical effect of the drug, the paralyzed side`s clinical score was 18% higher than pretreatment, with an increased quality of life.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: The use of Onyx in the treatment of intracranial AVMs has increased the cure rate of endovascular embolization compared with the use of liquid adhesive agents. Inadvertent occlusion of the draining veins before the complete exclusion of the nidus constitutes a major risk of bleeding. We report a case series using the technique of double simultaneous arterial catheterization as an approach to achieve the complete, exclusion of the nidus before reaching the venous drainage, through a more controlled hemodynamic filling. MATERIALS AND METHODS: Between April 2008 and November 2009, 17 patients with brain AVMs were treated by the DACT. The mean age of the patients was 32.7 years (range, 6-54 years), with 9 females and 8 males. The clinical onset was characterized by intracranial hemorrhage in 8 patients and by seizures in 7. The size of the AVMs ranged from 13 to 54 mm (average, 26.2 mm). The DACT was always used with the objective of curing the AVM. RESULTS: All 17 patients completed the EVT. The average number of sessions conducted was 1.4 (range, 1-3 sessions), with the average injection amount of 6.9 mL of Onyx (range, 2-25.2 mL). Sixteen AVMs (94.1%) were angiographically cured by embolization. Clinical complications occurred in 2 patients (11.7%); 1 of these was permanent (5.9%). No deaths were registered. CONCLUSIONS: This preliminary series shows that the DACT presents satisfactory results when used with curative intent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, the development and evaluation of a hyphenated flow injection-capillary electrophoresis system with on-line pre-concentration is described. Preliminary tests were performed to investigate the influence of flow rates over the analytical signals. Results revealed losses in terms of sensitivity of the FIA-CE system when compared to the conventional CE system. To overcome signal decrease and to make the system more efficient, a lower flow rate was set and an anionic resin column was added to the flow manifold in order to pre-concentrate the analyte. The pre-concentration FIA-CE system presented a sensitivity improvement of about 660% and there was only a small increase of 8% in total peak dispersion. These results have confirmed the great potential of the proposed system for many analytical tasks especially for low concentration samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a sequential injection chromatography procedure for determination of picloram in waters exploring the low backpressure of a 2.5 cm long monolithic C18 column. Separation of the analyte from the matrix was achieved in less than 60 s using a mobile phase composed by 20:80 (v v-1) acetonitrile:5.0 mmol L-1 H3PO4 and flow rate of 30 μL s-1. Detection was made at 223 nm with a 40 mm optical path length cell. The limits of detection and quantification were 33 and 137 μg L-1, respectively. The proposed method is sensitive enough to monitor the maximum concentration level for picloram in drinking water (500 μg L-1). The sampling frequency is 60 analyses per hour, consuming only 300 μL of acetonitrile per analysis. The proposed methodology was applied to spiked river water samples and no statistically significant differences were observed in comparison to a conventional HPLC-UV method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes a photo-reactor to perform in line degradation of organic compounds by photo-Fenton reaction using Sequential Injection Analysis (SIA) system. A copper phthalocyanine-3,4',4²,4²¢-tetrasulfonic acid tetrasodium salt dye solution was used as a model compound for the phthalocyanine family, whose pigments have a large use in automotive coatings industry. Based on preliminary tests, 97% of color removal was obtained from a solution containing 20 µmol L-1 of this dye.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate prospectively the actual bladder perforation incidence during transurethral resection of bladder tumor (TURB) performed by residents and to identify possible predisposing factors to such condition. Patients and Methods: Thirty-four patients with bladder tumor were submitted to TURB in our academic institution in April 2006, and were prospectively studied. Procedures were all done by senior residents under an attending direct supervision. All patients had a cystograms performed after the procedure by the injection of 400 mL of saline-diluted contrast solution with low-pressure infusion through the Foley catheter. The cystograms were evaluated blindly by a single radiologist. All patients were examined by cystoscopy and/or CT every 3 months for the first 2 years postoperatively. Results: The cystogram showed contrast leaking compatible with bladder perforation in 17 (50%) cases. None of the perforations were recognized intraoperatively by the surgeon. All perforations were extraperitoneal and managed conservatively. There was no significant correlation between the incidence of bladder perforation and the patient age (p = 0.508), the tumor stage (p = 0.998), the tumor grade (p = 0.833), the number of lesions (p = 0.394), and the tumor size (p = 0.651). The only factor that had impact on the development of bladder perforation was tumor localization at the bottom of the bladder (p = 0.035; OR, 6750; 95% CI, 1.14, 39.8). Conclusion: Asymptomatic perforations of the bladder wall occur very frequently after a TURB procedure performed by residents in training and, most of the time, are not noticed by the surgeon. Localization of the tumor at bladder dome was the only factor that negatively influenced perforation rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Cell therapy approaches for biologic cardiac repair hold great promises, although basic fundamental issues remain poorly understood. In the present study we examined the effects of timing and routes of administration of bone marrow cells (BMC) post-myocardial infarction (MI) and the efficacy of an injectable biopolymer scaffold to improve cardiac cell retention and function. Methodology/Principal Findings: (99m)Tc-labeled BMC (6x10(6) cells) were injected by 4 different routes in adult rats: intravenous (IV), left ventricular cavity (LV), left ventricular cavity with temporal aorta occlusion (LV(+)) to mimic coronary injection, and intramyocardial (IM). The injections were performed 1, 2, 3, or 7 days post-MI and cell retention was estimated by gamma-emission counting of the organs excised 24 hs after cell injection. IM injection improved cell retention and attenuated cardiac dysfunction, whereas IV, LV or LV* routes were somewhat inefficient (< 1%). Cardiac BMC retention was not influenced by timing except for the IM injection that showed greater cell retention at 7 (16%) vs. 1, 2 or 3 (average of 7%) days post-MI. Cardiac cell retention was further improved by an injectable fibrin scaffold at day 3 post-MI (17 vs. 7%), even though morphometric and function parameters evaluated 4 weeks later displayed similar improvements. Conclusions/Significance: These results show that cells injected post-MI display comparable tissue distribution profile regardless of the route of injection and that there is no time effect for cardiac cell accumulation for injections performed 1 to 3 days post-MI. As expected the IM injection is the most efficient for cardiac cell retention, it can be further improved by co-injection with a fibrin scaffold and it significantly attenuates cardiac dysfunction evaluated 4 weeks post myocardial infarction. These pharmacokinetic data obtained under similar experimental conditions are essential for further development of these novel approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The T cell immunoglobulin mucin 3 (Tim-3) receptor is highly expressed on HIV-1-specific T cells, rendering them partially ""exhausted'' and unable to contribute to the effective immune mediated control of viral replication. To elucidate novel mechanisms contributing to the HTLV-1 neurological complex and its classic neurological presentation called HAM/TSP (HTLV-1 associated myelopathy/tropical spastic paraparesis), we investigated the expression of the Tim-3 receptor on CD8(+) T cells from a cohort of HTLV-1 seropositive asymptomatic and symptomatic patients. Patients diagnosed with HAM/TSP down-regulated Tim-3 expression on both CD8(+) and CD4(+) T cells compared to asymptomatic patients and HTLV-1 seronegative controls. HTLV-1 Tax-specific, HLA-A*02 restricted CD8(+) T cells among HAM/TSP individuals expressed markedly lower levels of Tim-3. We observed Tax expressing cells in both Tim-3(+) and Tim-3(-) fractions. Taken together, these data indicate that there is a systematic downregulation of Tim-3 levels on T cells in HTLV-1 infection, sustaining a profoundly highly active population of potentially pathogenic T cells that may allow for the development of HTLV-1 complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes the coupling of a biomimetic sensor to a flow injection system for the sensitive determination of paracetamol. The sensor was prepared as previously described in the literature (M. D. P. T. Sotomayor, A. Sigoli, M. R. V. Lanza, A. A. Tanaka and L. T. Kubota, J. Braz. Chem. Soc., 2008, 19, 734) by modifying a glassy carbon electrode surface with a Nafion (R) membrane doped with iron tetrapyridinoporphyrazine (FeTPyPz), a biomimetic catalyst of the P450 enzyme. The performance of the sensor for paracetamol detection was investigated and optimized in a flow injection system (FIA) using a wall jet electrochemical cell. Under optimized conditions a wide linear response range (1.0 x 10(-5) to 5.0 x 10(-2) mol L(-1)) was obtained, with a sensitivity of 2579 (+/- 129) mu A L mu mol(-1). The detection and quantification limits of the sensor for paracetamol in the FIA system were 1.0 and 3.5 mu mol L(-1), respectively. The analytical frequency was 51 samples h(-1), and over a period of five days (320 determinations) the biosensor maintained practically the same response. The system was successfully applied to paracetamol quantification in seven pharmaceutical formulations and in water samples from six rivers in Sao Paulo State, Brazil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow system designed with solenoid micro-pumps is proposed for fast and greener spectrophotometric determination of free glycerol in biodiesel. Glycerol was extracted from samples without using organic solvents. The determination involves glycerol oxidation by periodate, yielding formaldehyde followed by formation of the colored (3,5-diacetil-1,4-dihidrolutidine) product upon reaction with acetylacetone. The coefficient of variation, sampling rate and detection limit were estimated as 1.5% (20.0 mg L(-1) glycerol, n =10), 34 h(-1), and 1.0 mg L(-1) (99.7% confidence level), respectively. A linear response was observed from 5 to 50 mg L(-1), with reagent consumption estimated as 345 mu g of KIO(4) and 15 mg of acetylacetone per determination. The procedure was successfully applied to the analysis of biodiesel samples and the results agreed with the batch reference method at the 95% confidence level. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work a downscaled multicommuted flow injection analysis setup for photometric determination is described. The setup consists of a flow system module and a LED based photometer, with a total internal volume of about 170 mu L The system was tested by developing an analytical procedure for the photometric determination of iodate in table salt using N,N-diethyl-henylenediamine (DPD) as the chromogenic reagent. Accuracy was accessed by applying the paired r-test between results obtained using the proposed procedure and a reference method, and no significant difference at the 95% confidence level was observed. Other profitable features, such as a low reagent consumption of 7.3 mu g DPD per determination: a linear response ranging from 0.1 up to 3.0 m IO(3)(-), a relative standard deviation of 0.9% (n = 11) for samples containing 0.5 m IO(3)(-), a detection limit of 17 mu g L(-1) IO(3)(-), a sampling throughput of 117 determination per hour, and a waste generation 600 mu L per determination, were also achieved. (C) 2010 Elsevier B.V. All rights reserved.