19 resultados para Caesium 137, standard deviation

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new approach to fabricate a disposable electronic tongue is reported. The fabrication of the disposable sensor aimed the integration of all electrodes necessary for measurement in the same device. The disposable device was constructed with gold CD-R and copper sheets substrates and the sensing elements were gold, copper and a gold surface modified with a layer of Prussian Blue. The relative standard deviation for signals obtained from 20 different disposable gold and 10 different disposable copper electrodes was below 3.5%. The performance, electrode materials and the capability of the device to differentiate samples were evaluated for taste substances model, milk with different pasteurization processes (homogenized/pasteurized, ultra high temperature (UHT) pasteurized and UHT pasteurized with low fat content) and adulterated with hydrogen peroxide. In all analysed cases, a good separation between different samples was noticed in the score plots obtained from the principal component analysis (PCA). Crown Copyright (C) 2008 Published by Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An inappropriate prosthetic fit could cause stress over the interface implant/bone. The objective of this study was to compare stresses transmitted to implants from frameworks cast using different materials and to investigate a possible correlation between vertical misfits and these stresses. Fifteen one-piece cast frameworks simulating bars for fixed prosthesis in a model with five implants were fabricated and arranged into three different groups according to the material used for casting: CP Ti (commercially pure titanium), Co-Cr (cobalt-chromium) or Ni-Cr-Ti (nickel-chromium-titanium) alloys. Each framework was installed over the metal model with all screws tightened to a 10 N cm torque and then, vertical misfits were measured using an optical microscope. The stresses transmitted to implants were measured using quantitative photoelastic analysis in values of maximum shear stress (T), when each framework was tightened to the photoelastic model to a 10 N cm standardized torque. Stress data were statistically analyzed using one-way ANOVA and Tukey`s test and correlation tests were performed using Pearson`s rank correlation (alpha = 0.05). Mean and standard deviation values of vertical misfit are presented for CP Ti (22.40 +/- 9.05 mu m), Co-Cr (66.41 +/- 35.47 mu m) and Ni-Cr-Ti (32.20 +/- 24.47 mu m). Stresses generated by Co-Cr alloy (tau = 7.70 +/- 2.16 kPa) were significantly higher than those generated by CP Ti (tau = 5.86 +/- 1.55 kPa, p = 0.018) and Ni-Cr-Ti alloy (tau =5.74 +/- 3.05 kPa, p = 0.011), which were similar (p = 0.982). Correlations between vertical misfits and stresses around the implants were not significant as for any evaluated materials. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: We investigated whether lifestyle-induced changes in dietary fat quality are related to Improvements on glucose metabolism disturbances in Japanese Brazilians at high risk of type 2 diabetes Methods: One hundred forty-eight first- and second-generation subjects with impaired glucose tolerance or impaired fasting glycemia who attended a lifestyle intervention program for 12 mo were studied in the city of Bauru. State of Sao Paulo, Brazil Dietary fatty acid intakes at baseline and after 12 mo were estimated using three 24-h recalls. The effect of dietary fat intake on glucose metabolism was investigated by multiple logistic regression models Results: At baseline, mean standard deviation age and body mass index were 60 II y and 25 5 4.2 kg/m2, respectively After 12 mo. 92 subjects had normal plasma glucose levels and 56 remained in prediabetic conditions. Using logistic regression models adjusted for age, gender, generation, basal intake of explanatory nutrient, energy intake, physical activity, and waist circumference, the odds ratios (95% confidence intervals) for reversion to normoglycemia were 3 14 (1 22-8 10) in the second wrote of total w-3 fatty acid, 4 26 (1.34-13 57) in the second tunic of eicosapentaenoic acid, and 280 (1 10-7.10) in the second tertile of linolenic acid. Similarly. subjects in the highest wrote of w-3.w-6 fatty acid ratio showed a higher chance of improving glucose disturbances (2 51, 1.01-6.37) Conclusions: Our findings support the evidence of an independent protective effect of omega-3 fatty acid and of a higher omega-3:omega-6 fatty acid ratio on the glucose metabolism of high-risk individuals (C) 2010 Elsevier Inc All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective Underreporting of energy intake is prevalent in food surveys, but there is controversy about which dietary assessment method provides greater underreporting rates. Our objective is to compare validity of self-reported energy intake obtained by three dietary assessment methods with total energy expenditure (TEE) obtained by doubly labeled water (DLW) among Brazilian women. Design We used a cross-sectional study. Subjects/setting Sixty-five females aged 18 to 57 years (28 normal-weight, 10 over-weight, and 27 obese) were recruited from two universities to participate. Main outcome measures TEE determined by DLW, energy intake estimated by three 24-hour recalls, 3-day food record, and a food frequency questionnaire (FFQ). Statistical analyses performed Regression and analysis of variance with repeated measures compared TEE and energy intake values, and energy intake-to-TEE ratios and energy intake-TEE values between dietary assessment methods. Bland and Altman plots were provided for each method. chi(2) test compared proportion of underreporters between the methods. Results Mean TEE was 2,622 kcal (standard deviation [SD] =490 kcal), while mean energy intake was 2,078 kcal (SD=430 kcal) for the diet recalls; 2,044 kcal (SD=479 kcal) for the food record and 1,984 kcal (SD=832 kcal) for the FFQ (all energy intake values significantly differed from TEE; P<0.0001). Bland and Altman plots indicated great dispersion, negative mean differences between measurements, and wide limits of agreement. Obese subjects underreported more than normal-weight subjects in the diet recalls and in the food records, but not in the FFQ. Years of education, income and ethnicity were associated with reporting accuracy. Conclusions The FFQ produced greater under- and overestimation of energy intake. Underreporting of energy intake is a serious and prevalent error in dietary self-reports provided by Brazilian women, as has been described in studies conducted in developed countries.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study aimed at verifying the associated factors of self-perceived body changes in adults living with HIV in highly-active antiretroviral therapy (HAART) in the city of Sao Paulo, Brazil. This cross-sectional study was conducted among people living with HIV on HAART for at least three months. A standardized questionnaire was used for assessing self-perceived body changes. Associated factors relating to self-reported body changes in people living with HIV (PLHIV) were assessed with Student`s t-test and chi-square test. In total, 507 patients were evaluated. The mean time since diagnosis was 6.6 years [standard deviation (SD)+/-4.1], and the mean duration of HAART was 5.1 years (SD+/-3.3). Self-perceived body changes were reported by 79.5% of the participants and were associated with viral load and duration of HAART. Fibre intake was lower among males who gained in abdominal fat (p=0.035). HAART-related body changes were reported by the large majority of the population and were associated with demographic and clinical variables.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to investigate the effect of 830 nm low-level laser therapy (LLLT) on skeletal muscle fatigue. Ten healthy male professional volleyball players entered a crossover randomized double-blinded placebo-controlled trial. Active LLLT (830 nm wavelength, 100 mW output, spot size 0.0028 cm(2), 200 s total irradiation time) or an identical placebo LLLT was delivered to four points on the biceps humeri muscle immediately before exercises. All subjects performed voluntary biceps humeri contractions with a load of 75% of the maximum voluntary contraction (MVC) force until exhaustion. After active LLLT the mean number of repetitions was significantly higher than after placebo irradiation [mean difference 4.5, standard deviation (SD) +/- 6.0, P = 0.042], the blood lactate levels increased after exercises, but there was no significant difference between the treatments. We concluded that 830 nm LLLT can delay the onset of skeletal muscle fatigue in high-intensity exercises, in spite of increased blood lactate levels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To describe corneal graft survival and visual outcome after therapeutic penetrating keratoplasty in patients with Acanthamoeba keratitis (AK) that is unresponsive to clinical treatment. Methods: Retrospective study. Thirty-two patients with AK who underwent therapeutic penetrating keratoplasty (tPK) from August 1996 to August 2005 were included. Data relating to clinical features, visual acuity, surgical technique, graft survival and complications were collected. Graft survival was evaluated by the Kaplan-Meier method and comparisons were performed using the Log-rank test. Results: Most patients (62.5%) were female. Mean age [+/- standard deviation (SD)] was 35 (+/- 13) years (range 15-68 years). All patients were contact lens wearers. Eighteen patients (56%) presented paralytic mydriasis and glaucoma during the treatment. Thirteen patients (40%) developed glaucoma after surgery; eight of them (61%) required a second PK because of graft failure. Of the 32 keratoplasty eyes, 56.2% presented graft failure at any follow-up point. Forty-five per cent of graft failures occurred before the 12 month follow-up, so 55% remained clear in the first year after surgery. Twelve patients underwent a second PK; seven of them failed and 45% were clear at 1 year. Two patients presented graft recurrence of amoebic infection. There was no significant difference in graft survival when eyes with or without mydriasis were compared (P = 0.40). Eyes with glaucoma presented a significantly shorter graft survival (P = 0.01). Conclusion: Penetrating keratoplasty is a treatment option for eyes that are unresponsive to clinical treatment infections. However, graft survival is poor; postoperative glaucoma is frequent and is associated with shorter graft survival.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Low-density lipoprotein (LDL) particles are the major cholesterol-carrying lipoprotein in the human circulation from the liver to peripheral tissues. High levels of LDL-Cholesterol (LDL-C) are known risk factor for the development of coronary artery disease (CAD). The most common approach to determine the LDLC in the clinical laboratory involves the Friedewald formula. However, in certain situations, this approach is inadequate. In this paper we report on the enhancement on the Europium emission band of Europium chlortetracycline complex (CTEu) in the presence of LDL. The emission intensity at 615 nm of the CTEu increases with increasing amounts of LDL. This phenomenon allowed us to propose a method to determine the LDL concentration in a sample composed by an aqueous solution of LDL. With this result we obtained LDL calibration curve, LOD (limit of detection) of 0.49 mg/mL and SD (standard deviation) of 0.003. We observed that CTEu complex provides a wider dynamic concentration-range for LDL determination than that from Eu-tetracycline previously. The averaged emission lifetimes of the CTEu and CTEu with LDL (1.5 mg/mL) complexes were measured as 15 and 46 Its, respectively. Study with some metallic interferents is presented. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Potassium content in tea brew was determined by gamma-ray spectroscopy, Using the 1461 keV gamma-ray fro M (40)K, the naturally occurring radioactive isotope of potassium. We measured radiation with a shielded HPGe detector from individual test samples of tea leaves, before and after infusion preparation, and from commercial instant tea powder. The correction factor for the gamma-ray self-absorption in the extended source was determined with the help of Monte-Carlo simulations. This gamma-ray spectroscopy technique enabled the absolute determination of potassium content with a relative uncertainty smaller than 4%, at the one standard deviation confidence level, showing the feasibility of this method. An experiment to evaluate a possible systematic Uncertainty due to K distribution heterogeneity in the sample was performed, with file result that the corresponding relative standard deviation is smaller than 2% at 95% confidence level. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The count intercept is a robust method for the numerical analysis of fabrics Launeau and Robin (1996). It counts the number of intersections between a set of parallel scan lines and a mineral phase, which must be identified on a digital image. However, the method is only sensitive to boundaries and therefore supposes the user has some knowledge about their significance. The aim of this paper is to show that a proper grey level detection of boundaries along scan lines is sufficient to calculate the two-dimensional anisotropy of grain or crystal distributions without any particular image processing. Populations of grains and crystals usually display elliptical anisotropies in rocks. When confirmed by the intercept analysis, a combination of a minimum of 3 mean length intercept roses, taken on 3 more or less perpendicular sections, allows the calculation of 3-dimensional ellipsoids and the determination of their standard deviation with direction and intensity in 3 dimensions as well. The feasibility of this quick method is attested by numerous examples on theoretical objects deformed by active and passive deformation, on BSE images of synthetic magma flow, on drawing or direct analysis of thin section pictures of sandstones and on digital images of granites directly taken and measured in the field. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Surface roughness is an important geomorphological variable which has been used in the Earth and planetary sciences to infer material properties, current/past processes, and the time elapsed since formation. No single definition exists; however, within the context of geomorphometry, we use surface roughness as an expression of the variability of a topographic surface at a given scale, where the scale of analysis is determined by the size of the landforms or geomorphic features of interest. Six techniques for the calculation of surface roughness were selected for an assessment of the parameter`s behavior at different spatial scales and data-set resolutions. Area ratio operated independently of scale, providing consistent results across spatial resolutions. Vector dispersion produced results with increasing roughness and homogenization of terrain at coarser resolutions and larger window sizes. Standard deviation of residual topography highlighted local features and did not detect regional relief. Standard deviation of elevation correctly identified breaks of slope and was good at detecting regional relief. Standard deviation of slope (SD(slope)) also correctly identified smooth sloping areas and breaks of slope, providing the best results for geomorphological analysis. Standard deviation of profile curvature identified the breaks of slope, although not as strongly as SD(slope), and it is sensitive to noise and spurious data. In general, SD(slope) offered good performance at a variety of scales, while the simplicity of calculation is perhaps its single greatest benefit.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel approach of using a gold disc microelectrode to analyze sweat samples for copper ions by anodic square wave stripping voltammetry (SW stripping voltammetry) is described Sweat was collected from the lower back of four subjects after physical exercise and the sample volume required for the determinations was 100 mu L. Under the optimized conditions the calibration plot was linear over the range 1-100 mu mol L(-1) Cu(II) with a limit of detection of 0 25 mu mol L(-1) The precision was evaluated by carrying out five replicate measurements in a 1 mu mol L(-1) Cu(II) solution and the standard deviation was found to be 1 5% Measurements were performed by inserting the microelectrode into sweat drops and Cu(II) concentrations in the analyzed samples ranged from 09 to 28 mu mol L(-1) Values obtained by the proposed voltammetric method agreed well with those found using graphite furnace atomic absorption spectroscopy (GFAAS) (C) 2010 Elsevier B V All rights reserved

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In situ fusion on the boat-type graphite platform has been used as a sample pretreatment for the direct determination of Co, Cr and Mn in Portland cement by solid sampling graphite furnace atomic absorption spectrometry (SS-GF AAS). The 3-field Zeeman technique was adopted for background correction to decrease the sensitivity during measurements. This strategy allowed working with up to 200 mu g of sample. The in situ fusion was accomplished using 10 mu L of a flux mixture 4.0% m/v Na(2)CO(3) + 4.0% m/v ZnO + 0.1% m/v Triton (R) X-100 added over the cement sample and heated at 800 degrees C for 20 s. The resulting mould was completely dissolved with 10 mu L of 0.1% m/v HNO(3). Limits of detection were 0.11 mu g g(-1) for Co, 1.1 mu g g(-1) for Cr and 1.9 mu g g(-1) for Mn. The accuracy of the proposed method has been evaluated by the analysis of certified reference materials. The values found presented no statistically significant differences compared to the certified values (Student`s t-test, p<0.05). In general, the relative standard deviation was lower than 12% (n = 5). (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electrodeposition of bismuth on gold microelectrodes for determination of Pb(II) by square wave anodic stripping voltammetry (SWASV) was accomplished by an in situ procedure in alkaline solution. A linear calibration plot for Pb(II) in the concentration range 40 to 6700 nmol L(-1) (r=0.998) was obtained, the detection limit was found to be 12.5 nmol L(-1) (S/N = 3) and the relative standard deviation in Solutions containing 1 mu mol L(-1) Pb(II) was 4% (n = 12). The analytical performance of the proposed sensor wits tested by measuring the Pb(II) concentration in a wine sample. The result Was in good agreement with the one obtained by GFAAS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new compact system encompassing in flow gas diffusion unit and a wall-jet amperometric FIA detector, coated with a supramolecular porphyrin film, was specially designed as an alternative to the time-consuming Monier-Williams method, allowing fast, reproducible and accurate analyses of free sulphite species in fruit juices. In fact, a linear response between 0.64 and 6.4 ppm of sodium sulphite. LOD = 0.043 ppm, relative standard deviation of +/- 1.5% (n = 10) and analytical frequency of 85 analyses/h were obtained utilising optimised conditions. That superior analytical performance allows the precise evaluation of the amount of free sulphite present in foods, providing an important comparison between the standard addition and the standard injection methods. Although the first one is most frequently used, it was strongly influenced by matrix effects because of the unexpected reactivity of sulphite ions with the juice matrixes, leading to its partial consumption soon after addition. In contrast, the last method was not susceptible to matrix effects yielding accurate results, being more reliable for analytical purposes. (C) 2011 Elsevier Ltd. All rights reserved.