106 resultados para 63-472A

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Precise quasielastic and alpha-transfer excitation functions, at theta(lab) = 161 degrees, have been measured at energies near the Coulomb barrier for the (16)O + (63)Cu system. This is the first time reported quasielastic barrier distribution for a medium odd-A nucleus target deduced from the data. Additional elastic scattering angular distributions data available in the literature for this system were also used in the investigation of the role of several individual channels in the reaction dynamics, by comparing the data with free-parameter coupled-channels calculations. In order to do so, the nucleus-nucleus bare potential has a double-folding potential as the real component and only a very short-range imaginary potential. The quasielastic barrier distribution has been shown to be a powerful tool in this analysis at the barrier region. A high collectivity of the (63)Cu was observed, mainly due to the strong influence of its 5/2-and 7/2-states on all reaction channels investigated. A striking influence of the reorientation of the ground-state target-spin on the elastic cross sections, taken at backward angles, was also observed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: This study aimed to asses oral health conditions in a population aged 60 years and over living in Botucatu, Southeastern Brazil. A cross-sectional population-based study was carried out using a random sample (N=372) of the urban population aged 60 years and over from the city of Botucatu, in 2005. World Health Organization criteria and codes for oral health epidemiological surveys were used. Re-examination was carried out in 10% of individuals aiming to evaluate intra-examiner agreement. Statistical analysis was performed by one-way ANOVA or Kruskal-Wallis ANOVA, as applicable. Also, the t-test was used in the absence of homoscedasticity. Fisher's exact test was used for situations where the categories with less than five units were observed. Adjusted residuals and multiple-comparison analysis were conducted to identify associations between variable categories and subgroups. The intra-examiner agreement was 98% and Kappa statistics result was 0.95. Loss component represented 90.68% of DMF-T index, which was 29.85. The prevalence of edentulism was 63.17%. Upper and lower dentures were found in 80% and 58% respectively, with complete denture as the most commonly used. In those studied, 15% required upper and 38% lower dentures. There was more need for complete denture in both jaws. Approximately 20% had soft tissue alterations. For periodontal conditions, most sextants were excluded (81.81%). Periodontal pockets (4 - 5 mm) were seen in 11.29% of the examined individuals. The oral health status of the elderly population in Botucatu is poor, as well as in other Brazilian cities. The results of this study may help planning collective health actions, giving an accurate description of the oral problems among the elderly.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivou-se identificar fatores associados ao edentulismo e o seu risco espacial em idosos. Foi realizado um estudo transversal em uma amostra de 372 indivíduos de 60 anos e mais, no Município de Botucatu, São Paulo, Brasil, em 2005. Razões de prevalência brutas e ajustadas foram estimadas por meio de regressão de Poisson, com estimativa robusta da variância e procedimentos de modelagem hierárquica. A análise espacial foi realizada por estimativas de densidade de Kernel. A prevalência de edentulismo foi de 63,17%. Os fatores sociodemográficos associados ao edentulismo foram a baixa escolaridade, o aumento do número de pessoas por cômodo, não possuir automóvel e idade mais avançada, presença de comorbidades, ausência de um cirurgião-dentista regular e ter realizado a última consulta há três anos ou mais. A análise espacial mostrou maior risco nas áreas periféricas. Obteve-se uma melhor compreensão da perda dentária entre os idosos, subsidiando o planejamento de ações em saúde coletiva.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to assess the salivary residual effect of fluoride dentifrice on human enamel subjected to an erosive challenge. This crossover in situ study was performed in two phases (A and B), involving ten volunteers. In each phase, they wore acrylic palatal appliances, each containing 3 human enamel blocks, during 7 days. The blocks were subjected to erosion by immersion of the appliances in a cola drink for 5 minutes, 4 times a day. Dentifrice was used to brush the volunteers’ teeth, 4 times a day, during 1 minute, before the appliance was replaced into the mouth. In phases A and B the dentifrices used had the same formulation, except for the absence (PD) or presence (FD) of fluoride, respectively. Enamel alterations were determined using profilometry, microhardness (%SMHC), acid- and alkali-soluble F analysis. The data were tested using ANOVA (p < 0.05). The concentrations (mean ± SD) of alkali- and acid-soluble F (µgF/cm²) were, respectively, PD: 1.27ª ± 0.70/2.24A ± 0.36 and FD: 1.49ª ± 0.44/2.24A ± 0.67 (p > 0.05). The mean wear values (± SD, µm) were PD: 3.63ª ± 1.54 and FD: 3.54ª ± 0.90 (p > 0.05). The mean %SMHC values (± SD) were PD: 89.63ª ± 4.73 and FD: 87.28ª ± 4.01 (p > 0.05). Thus, we concluded that the residual fluoride from the fluoride-containing dentifrice did not protect enamel against erosion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: esta pesquisa objetivou avaliar cefalometricamente as alterações dentoesqueléticas de jovens com Classe II dentária tratados com o distalizador Jones jig. METODOLOGIA: foram avaliados 30 pacientes, sendo 15 de cada gênero, com média de idades iniciais de 13,63 anos; brasileiros, naturais da cidade de Bauru/SP, caracterizados por má oclusão de Classe II, 1ª e 2ª divisões de Angle sem comprometimento esquelético. Os jovens foram tratados com aparelho Jones jig a fim de distalizar os molares superiores a uma relação molar de "super Classe I"; sendo que esse dispositivo permaneceu, em média, por 0,55 anos. Ao final da sobrecorreção, os molares distalizados receberam um botão de Nance e, como ancoragem extrabucal, o aparelho extrabucal (AEB) com tração média-alta, com o intuito de verticalizar e corrigir a angulação radicular dos molares distalizados. Foram realizadas telerradiografias em normal lateral inicial (T1) e pós-distalização (T2). As medidas cefalométricas foram submetidas ao teste t dependente de Student para avaliar as alterações de T1 para T2. RESULTADOS: com base nos resultados obtidos e a partir da metodologia empregada, observou-se alterações dentárias significativas, como a movimentação distal linear e angular, assim como a intrusão dos segundos e primeiros molares superiores no sentido vertical. Também se confirmou efeitos indesejáveis, como a perda de ancoragem refletida em mesialização, extrusão e angulação mesial dos segundos pré-molares, a protrusão dos incisivos superiores e o aumento do trespasse vertical e horizontal. Pode-se confirmar que certas movimentações dentárias promovem significativas alterações esqueléticas de estruturas localizadas à distância, ou seja, observou-se extrusão significativa dos segundos pré-molares superiores, o que resultou em rotação mandibular, aumento significativo da altura facial anteroinferior e protrusão do lábio inferior. CONCLUSÃO: pode-se concluir que o distalizador Jones jig promove, basicamente, alterações dentárias.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the response of the subcutaneous connective tissue of BALB/c mice to root filling materials indicated for primary teeth: zinc oxide/eugenol cement (ZOE), Calen paste thickened with zinc oxide (Calen/ZO) and Sealapex sealer. The mice (n=102) received polyethylene tube implants with the materials, thereby forming 11 groups, as follows: I, II, III: Calen/ZO for 7, 21 and 63 days, respectively; IV, V, VI: Sealapex for 7, 21 and 63 days, respectively; VII, VIII, IX: ZOE for 7, 21 and 63 days, respectively; X and XI: empty tube for 7 and 21 days, respectively. The biopsied tissues were submitted to histological analysis (descriptive analysis and semi-quantitative analysis using a scoring system for collagen fiber formation, tissue thickness and inflammatory infiltrate). A quantitative analysis was performed by measuring the area and thickness of the granulomatous reactionary tissue (GRT). Data were analyzed by Kruskal-Wallis, ANOVA and Tukey's post-hoc tests (?=0.05). There was no significant difference (p>0.05) among the materials with respect to collagen fiber formation or GRT thickness. However, Calen/ZO produced the least severe inflammatory infiltrate (p<0.05). The area of the GRT was significantly smaller (p<0.05) for Calen/ZO and Sealapex. In conclusion, Calen/ZO presented the best tissue reaction, followed by Sealapex and ZOE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the tissue compatibility of a silorane-based resin system (FiltekTM Silorane) and a methacrylate-based nanoparticle resin (FiltekTM Supreme XT) after implantation in the subcutaneous connective tissue of isogenic mice. One hundred and thirty five male isogenic BALB/c mice were randomly assigned to 12 experimental and 3 control groups, according to the implanted material and the experimental period of 7, 21 and 63 days. At the end of each period, the animals were killed and the tubes with the surrounding tissues were removed and processed for microscopic analysis. Samples were subjected to a descriptive and a semi-quantitative analyses using a 4-point scoring system (0-3) to evaluate the collagen fiber formation and inflammatory infiltrate. Data were statistically analyzed using the Kruskal Wallis test (?=0.05). The results showed that there was no significant difference between the experimental and control groups considering the three evaluation periods (p>0.05). The silorane-based and the methacrylate-based nanoparticle resins presented similar tissue response to that of the empty tube (control group) after subcutaneous implantation in isogenic mice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated in vitro the shear bond strength of a resin-based pit-and-fissure sealant (Fluroshield - F) associated with either an ethanol-based (Adper Single Bond 2 - SB) or an acetone-based (Prime & Bond - PB) adhesive system under conditions of oil contamination. Mesial and distal enamel surfaces from 30 sound third molars were randomly assigned to 2 groups (n=30): I - no oil contamination; II - oil contamination. Contamination (0.25 mL during 10 s) was performed after 37% phosphoric acid etching with an air/oil spray. The specimens were randomly assigned to subgroups, according to the bonding protocol adopted: subgroup A - F was applied to enamel without an intermediate bonding agent layer; In subgroups B and C, SB and PB, respectively, were applied, light-cured, and then F was applied and light-cured. Shear bond strength was tested at a crosshead speed of 0.5 mm/min in a universal testing machine. Means (± SD) in MPa were: IA-11.28 (±1.84); IIA-12.02 (±1.15); IB-9.73 (±2.38); IIB-9.62 (±2.29); IC-28.30 (±1.63); and IIC-25.50 (±1.91). It may be concluded that the oil contamination affected negatively the sealant bonding to enamel and the acetone-based adhesive system (PB) layer applied underneath the sealant was able to prevent its deleterious effects to adhesion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study was evaluated the response of subcutaneous connective tissue of isogenic mice to calcium hydroxide-based pastes with chlorhexidine digluconate (CHX). Seventy isogenic male BALB/c mice aged 6-8 weeks and weighing 15-20 g were randomly assigned to 8 groups. The animals received polyethylene tube implants as follows: Groups I, II, and III (n=10) - Calen® paste mixed with 0.4% CHX (experimental paste; Calen/CHX) for 7, 21, and 63 days, respectively; Groups IV, V, and VI (n=10) - UltraCal™ paste mixed with 2% CHX (experimental paste supplied by Ultradent Products Inc.; Ultracal/CHX) for 7, 21, and 63 days, respectively; and Groups VII and VIII (n=5): empty tube for 7 and 21 days, respectively. At the end of the experimental periods, the implants were removed together with the surrounding tissues (skin and subcutaneous connective tissue). The biopsied tissues were subjected to routine processing for histological analysis. Using a descriptive analysis and a four-point (0-3) scoring system, the following criteria were considered for qualitative and quantitative analysis of the tissue around the implanted materials: collagen fiber formation, tissue thickness and inflammatory infiltrate. A quantitative analysis was performed by measuring the thickness (µm), area (µm²) and perimeter (µm) of the reactionary granulomatous tissue formed at the tube ends. Data were analyzed statistically by the Kruskal-Wallis test and Dunn's post-test (α=0.05). Calen/CHX showed biocompatibility with the subcutaneous and reactionary tissues, with areas of discrete fibrosis and normal conjunctive fibrous tissue, though without statistically significant difference (p>0.05) from the control groups. In Groups I to III, there was a predominance of score 1, while in Groups IV to VI scores 2 and 3 predominated for all analyzed parameters. UltraCal/CHX, on the other hand, induced the formation of an inflammatory infiltrate and abundant exudate, suggesting a persistent residual aggression from the material, even 63 days after implant placement. In conclusion, the Calen paste mixed with 0.4% CHX allowed an adequate tissue response, whereas the UltraCal paste mixed with 2% CHX showed unsatisfactory results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the metal-ceramic bond strength (MCBS) of 6 metal-ceramic pairs (2 Ni-Cr alloys and 1 Pd-Ag alloy with 2 dental ceramics) and correlate the MCBS values with the differences between the coefficients of linear thermal expansion (CTEs) of the metals and ceramics. Verabond (VB) Ni-Cr-Be alloy, Verabond II (VB2), Ni-Cr alloy, Pors-on 4 (P), Pd-Ag alloy, and IPS (I) and Duceram (D) ceramics were used for the MCBS test and dilatometric test. Forty-eight ceramic rings were built around metallic rods (3.0 mm in diameter and 70.0 mm in length) made from the evaluated alloys. The rods were subsequently embedded in gypsum cast in order to perform a tensile load test, which enabled calculating the CMBS. Five specimens (2.0 mm in diameter and 12.0 mm in length) of each material were made for the dilatometric test. The chromel-alumel thermocouple required for the test was welded into the metal test specimens and inserted into the ceramics. ANOVA and Tukey's test revealed significant differences (p=0.01) for the MCBS test results (MPa), with PI showing higher MCBS (67.72) than the other pairs, which did not present any significant differences. The CTE (10-6 oC-1) differences were: VBI (0.54), VBD (1.33), VB2I (-0.14), VB2D (0.63), PI (1.84) and PD (2.62). Pearson's correlation test (r=0.17) was performed to evaluate of correlation between MCBS and CTE differences. Within the limitations of this study and based on the obtained results, there was no correlation between MCBS and CTE differences for the evaluated metal-ceramic pairs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study, a questionnaire was applied to patients from Ribeirão Preto Dental School, University of São Paulo, Brazil, to evaluate the hygiene methods and habits concerning the use of complete dentures, the age of dentures, and whether patients have been instructed on how to clean their dentures. The mean age of patients was 63.35 years, and most of them were females (82.08%). The results showed that 62.26% of the respondents had been using the same maxillary complete denture for more than 5 years, and 49.06% used the same mandible complete denture for more than 5 years. Of the patients interviewed, 58.49% slept with the dentures. Mechanical brushing was the most used cleaning method by the patients (100%), using water, dentifrice and toothbrush (84.91%). Most patients (51.89%) reported never having been instructed by their dentists as to how to clean their dentures. Based on the limitations of this study, it was concluded that the patients interviewed had limited knowledge about prosthetic hygiene and oral care. The method more used by patients was the mechanical method of brushing, most patients used the same complete dentures for more than 5 years and slept with the dentures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate the color stability and hardness of two denture liners obtained by direct and indirect techniques, after thermal cycling and immersion in beverages that can cause staining of teeth. MATERIAL AND METHODS: Seventy disc-shaped specimens (18 x 3 mm) processed by direct (DT) and indirect techniques (IT) were made from Elite soft (n=35) and Kooliner (n=35) denture liners. For each material and technique, 10 specimens were subjected to thermal cycling (3,000 cycles) and 25 specimens were stored in water, coffee, tea, soda and red wine for 36 days. The values of color change, Shore A hardness (Elite soft) and Knoop hardness (Kooliner) were obtained. The data were subjected to ANOVA, Tukey's multiple-comparison test, and Kruskal-Wallis test (P<0.05). RESULTS: The thermal cycling promoted a decrease on hardness of Kooliner regardless of the technique used (Initial: 9.09± 1.61; Thermal cycling: 7.77± 1.47) and promoted an increase in the hardness in the DT for Elite Soft (Initial: 40.63± 1.07; Thermal cycling: 43.53± 1.03); hardness of Kooliner (DT: 8.76± 0.95; IT: 7.70± 1.62) and Elite Soft (DT: 42.75± 1.54; IT=39.30± 2.31) from the DT suffered an increase after the immersion in the beverages. The thermal cycling promoted color change only for Kooliner in the IT. Immersion in the beverages did not promote color change for Elite in both techniques. The control group of the DT of Kooliner showed a significant color change. Wine and coffee produced the greatest color change in the DT only for Elite Soft when compared to the other beverages. CONCLUSION: The three variation factors promoted alteration on hardness and color of the tested denture lining materials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: avaliar características clínicas, patológicas e moleculares de carcinomas mamários em mulheres muito jovens em comparação a tumores de mulheres na pós-menopausa. MÉTODOS: foram selecionados 106 casos de câncer de mama de mulheres jovens e 130 casos de mulheres pós-menopausa. Foram analisados dados clínicos (idade ao diagnóstico, estadiamento, ocorrência de metástases, tempo de sobrevida global e livre de doença), anátomo-patológicos (tamanho do tumor, tipo e grau histológico do tumor primário) e marcadores moleculares (receptores de estrógeno e progesterona, HER2, p53, p63, citoqueratinas 5 e 14 e EGFR) com uso da imunoistoquímica empregando microarranjo de tecido. Foi analisada a relação entre as características clínico-patológicas, imunoistoquímicas e de sobrevidas global e livre de doença. RESULTADOS: as pacientes muito jovens apresentaram maior frequência de nuliparidade (p=0,03), maior diâmetro dos tumores (p<0,000), estadiamento clínico mais avançado (p=0,01), maior número de linfonodos positivos (p=0,001) e tumores pouco diferenciados (p=0,004). A maioria das pacientes jovens recebeu tratamento com quimioterapia (90,8%) e radioterapia (85,2%) e em menor proporção com tamoxifeno (31,5%), comparado às mulheres na pós-menopausa. Observamos baixa positividade para o receptor de estrógeno (49,1%; p=0,01) e alta positividade para a proteína HER2 (28,7%; p=0,03) nas mulheres jovens. O fenótipo triplo-negativo foi observado em 29,6% no grupo jovem e em 20% nas mulheres na pós-menopausa. Os tumores de fenótipo basal foram mais frequentes nas mulheres jovens (50%). As metástases sistêmicas ocorreram em 55,3% dos casos nas jovens e em 39,2% nas idosas. As sobrevidas global e livre de doença em cinco anos foram, respectivamente, 63 e 39% para as mulheres jovens e 75 e 67% para o grupo de mulheres na pós-menopausa. CONCLUSÕES: carcinomas mamários de mulheres muito jovens têm características clínicas, patológicas e moleculares mais agressivas quando comparadas às mulheres acima de 50 anos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Oral carcinogenesis is a multi-step process. One possible step is the development of potentially malignant disorders known as leukoplakia and erytroplakia. The objective of this study was to use immunohistochemistry to analyze the patterns of expression of the cell-cycle regulatory proteins p53 and p16INK4a in potentially malignant disorders (PMD) of the oral mucosa (with varying degrees of dysplasia) and in oral squamous cell carcinomas (OSCC) to correlate them with the expression of telomerase (hTERT). Fifteen PMD and 30 OSCC tissue samples were analyzed. Additionally, 5 cases of oral epithelial hyperplasia (OEH) were added to analyze clinically altered mucosa presenting as histological hyperplasia without dysplasia. p53 positivity was observed in 93.3% of PMD, in 63.3% of OSCC and in 80% of OEH. Although there was no correlation between p53 expression and the grade of dysplasia, all cases with severe dysplasia presented p53 suprabasal immunoexpression. p16INK4a expression was observed in 26.7% of PMD, in 43.3% of OSCC and in 2 cases of OEH. The p16INK4a expression in OEH, PMD and OSCC was unable to differentiate non-dysplastic from dysplastic oral epithelium. hTERT positivity was observed in all samples of OEH and PMD and in 90% of OSCC. The high hTERT immunoexpression in all three lesions indicates that telomerase is present in clinically altered oral mucosa but does not differentiate hyperplastic from dysplastic oral epithelium. In PMD of the oral mucosa, the p53 immunoexpression changes according to the degree of dysplasia by mechanisms independent of p16INK4a and hTERT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the effect of specimens' design and manufacturing process on microtensile bond strength, internal stress distributions (Finite Element Analysis - FEA) and specimens' integrity by means of Scanning Electron Microscopy (SEM) and Laser Scanning Confocal Microscopy (LCM). Excite was applied to flat enamel surface and a resin composite build-ups were made incrementally with 1-mm increments of Tetric Ceram. Teeth were cut using a diamond disc or a diamond wire, obtaining 0.8 mm² stick-shaped specimens, or were shaped with a Micro Specimen Former, obtaining dumbbell-shaped specimens (n = 10). Samples were randomly selected for SEM and LCM analysis. Remaining samples underwent microtensile test, and results were analyzed with ANOVA and Tukey test. FEA dumbbell-shaped model resulted in a more homogeneous stress distribution. Nonetheless, they failed under lower bond strengths (21.83 ± 5.44 MPa)c than stick-shaped specimens (sectioned with wire: 42.93 ± 4.77 MPaª; sectioned with disc: 36.62 ± 3.63 MPa b), due to geometric irregularities related to manufacturing process, as noted in microscopic analyzes. It could be concluded that stick-shaped, nontrimmed specimens, sectioned with diamond wire, are preferred for enamel specimens as they can be prepared in a less destructive, easier, and more precise way.