173 resultados para P(P)OVER-BAR COLLISIONS


Relevância:

50.00% 50.00%

Publicador:

Resumo:

In the title molecule, C(11)H(14)BrNO, there is twist between the mean plane of the amide group and the benzene ring [C(=O)-N-C...;C torsion angle = -31.2 (5)degrees]. In the crystal, intermolecular N-H...O and weak C-H...O hydrogen bonds link molecules into chains along [100]. The methyl group H atoms are disordered over two sets of sites with equal occupancy.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

A sensitive and reproducible stir bar-sorptive extraction and high-performance liquid chromatography-UV detection (SBSE/HPLC-UV) method for therapeutic drug monitoring of carbamazepine, carbamazepine-10,11-epoxide, phenytoin and phenobarbital in plasma samples is described and compared with a liquid:liquid extraction (LLE/HPLC-UV) method. Important factors in the optimization of SBSE efficiency such as pH, extraction time and desorption conditions (solvents, mode magnetic stir, mode ultrasonic stir, time and number of steps) assured recoveries ranging from 72 to 86%, except for phenytoin (62%). Separation was obtained using a reverse phase C-18 column with UV detection (210 nm). The mobile phase consisted of water: acetonitrile (78:22, v/v). The SBSE/HPLC-UV method was linear over a working range of 0.08-40.0 mu g mL(-1) for carbamazepine, carbamazepine-10,11-epoxide and phenobarbital and 0.125-40.0 mu g mL(-1) for phenytoin, The intra-assay and inter-assay precision and accuracy were studied at three concentrations (1.0, 4.0 and 20.0 mu g mL(-1)). The intra-assay coefficients of variation (CVs) for all compounds were less than 8.8% and all inter-CVs were less than 10%. Limits of quantification were 0.08 mu g mL(-1) for carbamazepine, carbamazepine-10,11-epoxide and phenobarbital and 0.125 mu g mL(-1) for phenytoin. No interference of the drugs normally associated with antiepileptic drugs was observed. Based on figures of merit results, the SBSE/HPLC-UV proved adequate for antiepileptic drugs analyses from therapeutic levels. This method was successfully applied to the analysis of real samples and was as effective as the LLE/HPLC-UV method. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

A sensitive and precise stir bar sorptive extraction (SBSE) combined with LC (SBSE/LC) analysis is described for simultaneous determination of methyl, ethyl, propyl, and butyl parabens in commercial cosmetic products in agreement with the European Union Cosmetics Directive 76/768/EEC. Important factors in the optimization of SB SE efficiency are discussed, such as time and temperature of extraction, pH, and ionic strength of the sample, matrix effects, and liquid desorption conditions by different modes (magnetic stirring, ultrasonic). The LOQs of the SBSE/LC method ranged from 30 to 200 ng/mg, with linear response over a dynamic range, from the LOQ to 2.5 mu g/mg, with a coefficient of determination higher than 0.993. The interday precision of the SBSE/LC method presented a coefficient of variation lower than 5%. The effectiveness of the proposed method was proven for analysis of commercial cosmetic products such as body creams, antiperspirant creams, and sunscreens.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

A sensitive and reproducible stir bar-sorptive extraction and high performance liquid chromatography-UV detection (SBSE/HPLC-UV) method for therapeutic drug monitoring of rifampicin in plasma samples is described and compared with a liquid:liquid extraction (LLE/HPLC-UV) method. This miniaturized method can result in faster analysis, higher sample throughput, lower solvent consumption and less workload per sample while maintaining or even improving sensitivity. Important factors in the optimization of SBSE efficiency such as pH, temperature, extraction time and desorption conditions (solvents, mode magnetic stir, mode ultrasonic stir, time and number of steps) were optimized recoveries ranging from 75 to 80%. Separation was obtained using a reverse phase C(8) column with UV detection (254 nm). The mobile phase consisted of methanol:0.25 N sodium acetate buffer, pH 5.0 (58:42, v/v). The SBSE/HPLC-UV method was linear over a working range of 0.125-50.0 mu g mL(-1). The intra-assay and inter-assay precision and accuracy were studied at three concentrations (1.25, 6.25 and 25.0 mu g mL(-1)). The intra-assay coefficients of variation (CVs) for all compounds were less than 10% and all inter-CVs were less than 10%. Limits of quantification were 0.125 mu g mL(-1). Stability studies showed rifampicin was stable in plasma for 12 h after thawing; the samples were also stable for 24 h after preparation. Based on the figures of merit results, the SBSE/HPLC-UV proved to be adequate to the rifampicin analyses from therapeutic to toxic levels. This method was successfully applied to the analysis of real samples and was as effective as the LLE/HPLC-UV method. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

We present the first measurement of photoproduction of J/psi and of two-photon production of high-mass e(+)e(-) pairs in electromagnetic (or ultra-peripheral) nucleus-nucleus interactions, using Au + Au data at root s(NN) = 200 GeV. The events are tagged with forward neutrons emitted following Coulomb excitation of one or both Au* nuclei. The event sample consists of 28 events with m(e+e-) > 2 GeV/c(2) with zero like-sign background. The measured cross sections at midrapidity of d sigma/dy (J/psi + Xn, y = 0) = 76 +/- 33 (stat) +/- 11 (syst) pb and d(2)sigma /dm dy (e(+) e(-) + Xn, y = 0) = 86 +/- 23(stat) +/- 16(syst) mu b/ (GeV/c(2)) for m(e+e-) epsilon vertical bar 2.0, 2.8 vertical bar GeV/c(2) have been compared and found to be consistent with models for photoproduction of J/psi and QED based calculations of two-photon production of e(+)e(-) pairs. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

We present measurements of the charge balance function, from the charged particles, for diverse pseudorapidity and transverse momentum ranges in Au + Au collisions at root S(NN) = 200 GeV using the STAR detector at RHIC. We observe that the balance function is boost-invariant within the pseudorapidity coverage vertical bar-1.3, 1.3 vertical bar. The balance function properly scaled by the width of the observed pseudorapidity window does not depend on the position or size of the pseudorapidity window. This scaling property also holds for particles in different transverse momentum ranges. In addition, we find that the width of the balance function decreases monotonically with increasing transverse momentum for all centrality classes. (c) 2010 Elsevier B.V. All rights reserved.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Combined fluid inclusion (FI) microthermometry, Raman spectroscopy, X-ray diffraction, C-O-H isotopes and oxygen fugacities of granulites from central Ribeira Fold Belt, SE Brazil, provided the following results: i) Magnetite-Hematite fO(2) estimates range from 10(-11.5) bar (QFM + 1) to 10(-18.3) bar (QFM - 1) for the temperature range of 896 degrees C-656 degrees C, implying fO(2) decrease from metamorphic peak temperatures to retrograde conditions; ii) 5 main types of fluid inclusions were observed: a) CO(2) and CO(2)-N(2) (0-11 mol%) high to medium density (1.01-0.59 g/cm(3)) FI; b) CO(2) and CO(2)-N(2) (0-36 mol%) low density (0.19-0.29 g/cm(3)) FI; c) CO(2) (94-95 mol%)-N(2) (3 mol%)-CH(4) (2-3 mol%)-H(2)O (water phi(v) (25 degrees C) = 0.1) FI; d) low-salinity H(2)O-CO(2) FI; and e) late low-salinity H(2)O FI; iii) Raman analyses evidence two graphite types in khondalites: an early highly ordered graphite (T similar to 450 degrees C) overgrown by a disordered kind (T similar to 330 degrees C); iv) delta(18)O quartz results of 10.3-10.7 parts per thousand, imply high-temperature CO(2) delta(18)O values of 14.4-14.8 parts per thousand, suggesting the involvement of a metamorphic fluid, whereas lower temperature biotite delta(18)O and delta D results of 7.5-8.5 parts per thousand and -54 to -67 parts per thousand respectively imply H(2)O delta(18)O values of 10-11 parts per thousand and delta D(H2O) of -23 to -36 parts per thousand suggesting delta(18)O depletion and increasing fluid/rock ratio from metamorphic peak to retrograde conditions. Isotopic results are compatible with low-temperature H(2)O influx and fO(2) decrease that promoted graphite deposition in retrograde granulites, simultaneous with low density CO(2), CO(2)-N(2) and CO(2)-N(2)-CH(4)-H(2)O fluid inclusions at T = 450-330 degrees C. Graphite delta(13)C results of -10.9 to -11.4 parts per thousand imply CO(2) delta(13)C values of -0.8 to -1.3 parts per thousand suggesting decarbonation of Cambrian marine carbonates with small admixture of lighter biogenic or mantle derived fluids. Based on these results, it is suggested that metamorphic fluids from the central segment of Ribeira Fold Belt evolved to CO(2)-N(2) fluids during granulitic metamorphism at high fO(2), followed by rapid pressure drop at T similar to 400-450 degrees C during late exhumation that caused fO(2) reduction induced by temperature decrease and water influx, turning carbonic fluids into CO(2)-H(2)O (depleting biotite delta(18)O and delta D values), and progressively into H(2)O. When fO(2) decreased substantially by mixture of carbonic and aqueous fluids, graphite deposited forming khondalites. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Let A be a finitely generated abelian group. We describe the automorphism group Aut(A) using the rank of A and its torsion part p-part A(p). For a finite abelian p-group A of type (k(1),..., k(n)), simple necessary and sufficient conditions for an n x n-matrix over integers to be associated with an automorphism of A are presented. Then, the automorphism group Aut(A) for a finite p-group A of type (k(1), k(2)) is analyzed. (C) 2008 Mathematical Institute Slovak Academy of Sciences.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

In this article we prove that, if (U, ) is a finite dimensional baric algebra of (gamma, delta) type over a field F of characteristic not equal 2,3,5 such that gamma(2) - delta(2) + delta = 1 and 0,1, then rad(U) = R(U)boolean AND(bar(U))(2), where R(U) is the nilradical (maximal nil ideal) of U.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The analysis of the IR carbonyl band of the alpha-methylsulfonyl-alpha-diethoxyphosphoryl p-substituted acetophenones p-Y-Ph-C(O)CH(SO(2)Me)[P(O)(OEt)(2)] (Y = OMe 1, H 2, F 3, Cl 4, Br 5 and NO(2) 6) supported by HF/6-31G(d,p) ab initio calculations of the alpha-methylsulfonyl-alpha-diethoxyphosphoryl acetophenone 2, indicated the existence of a single stable cl conformer in gas phase and in solvents of increasing polarity, along with the presence of second less stable conformation in gas phase. The cl conformer present the (SO(2)Me) group and the [P(O)(OEt(2))] groups in a syn-clinal (gauche) geometry and is stabilised through of the 0(`60)... P(%), 01NO(owl Crco), ONO)... C(,C*.), 060)... S(`S`02.,) and 0(`S-02) q o) electronic interactions 08along with H(8S*o2M,). 0(660). HU(5C_H2)lP0Erl- 0(8so2m), H(6 +Ph)- - - (co) and H(8o+`-Ph). 0( `Po) intramolecular hydrogen bonds. The almost co nstant negative carbonyl frequency shifts (Av) for the title compounds 1-6 with respect to the parent acetophenones 7-14 corroborates the prevalence of the electronic interactions over the -l(y inductive effect of the ot-substituents for the title compounds and gives strong support for the existence of the crossed 0`(`C-O)... S`(1S+02m,) and 0(""S-02) C(`C+O) (charge transfer and electrostatic); 08-) (co P(`i o) and 01`M-OFt)l C(` o), (electrostatic) interactions. 0 2008 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This article reports the case of a 55-year-old female patient who presented with unsatisfactory temporary crowns in the right mandibular premolars and molars, and a premolar-to-molar fixed partial denture in the left side. The clinical and radiographic examinations revealed a fracture of the left first premolar that was a retainer of the fixed partial denture and required extraction. Initially, the acrylic resin crowns were replaced by new ones, and a provisional RPD was made using acrylic resin and orthodontic wire clasps to resolve the problem arising from the loss of the fixed partial denture. Considering the patient's high esthetic demands, the treatment options for the definitive prosthetic treatment were discussed with her and rehabilitation with implant-supported dentures was proposed because the clinical conditions of the residual alveolar ridge were suitable for implant installation, and the patient's general health was excellent. However, the patient did not agree because she knew of a failed case of implant-retained denture in a diabetic individual and was concerned. The patient was fully informed that implant installation was the best indication for her case, but the arguments were not sufficient to change her decision. The treatment possibilities were presented and the patient opted for a clasp-retained removable partial denture (RPD) associated with the placement of crowns in the pillar teeth. The temporary RPD was replaced by the definitive RPD constructed subsequently. Although RPD was not the first choice, satisfactory esthetic and functional outcomes were achieved, overcaming the patient's expectations. This case report illustrates that the dentist must be prepared to deal with situations where, for reasons that cannot be managed, the patient does not accept the treatment considered as the most indicated for his/her case. Alternatives must be proposed and the functional and esthetic requirements must be fulfilled in the best possible manner.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The objective of this study was to evaluate the retention force of T-bar clasps made from commercially pure titanium (CP Ti) and cobalt-chromium (Co-Cr) alloy by the insertion/removal test simulating 5 years use. Thirty-six frameworks were cast from CP Ti (n=18) and Co-Cr alloy (n=18) with identical prefabricated patterns on refractory casts from a distal extension mandibular hemi-arch segment. The castings were made on a vacuum-pressure machine, under vacuum and argon atmosphere. Each group was subdivided in three, corresponding to 0.25 mm, 0.50 mm and 0.75 mm undercuts, respectively. No polishing procedures were performed to ensure uniformity. The specimens were subjected to an insertion/removal test and data was analyzed statistically to compare CP Ti and Co-Cr alloy in the same undercut (Student's t-test for independent samples) and each material in different undercuts (one-way ANOVA) (p=0.05). Comparisons between materials revealed significant differences (p=0.017) only for the 0.50-mm undercut. No significant differences (p>0.05) were found when comparing the same material for the undercuts. It may be concluded that for different undercuts, both Co-Cr alloy and CP Ti had no significant differences for T-bar clasps; CP Ti showed the lowest retention force values when compared to Co-Cr alloy in each undercut, but with significant difference only for the 0.50-mm undercut; and both materials maintained the retentive capacity during the simulation test.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study evaluated the influence of a cola-type soft drink and a soy-based orange juice on the surface and subsurface erosion of primary enamel, as a function of the exposure time. Seventy-five primary incisors were divided for microhardness test (n=45) or scanning electron microscopy (SEM) analysis (n=30). The specimens were randomly assigned to 3 groups: 1 - artificial saliva (control); 2 - cola-type soft drink; and 3 - soy-based orange juice. Immersion cycles in the beverages were undertaken under agitation for 5 min, 3 times a day, during 60 days. Surface microhardness was measured at 7, 15, 30, 45 and 60 days. After 60 days, specimens were bisected and subsurface microhardness was measured at 30, 60, 90, 120, 150 and 200 µm from the surface exposed. Data were analyzed by ANOVA and Tukey’s test (a=0.05). Groups 2 and 3 presented similar decrease of surface microhardness. Regarding subsurface microhardness, group 2 presented the lowest values. SEM images revealed that after 60 days the surfaces clearly exhibited structural loss, unlike those immersed in artificial saliva. It may be concluded that erosion of the surfaces exposed to the cola-type soft drink was more accentuated and directly proportional to the exposure time.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study evaluated bone response to a Ca- and P- enriched titanium (Ti) surface treated by a multiphase anodic spark deposition coating (BSP-AK). Two mongrel dogs received bilateral implantation of 3 Ti cylinders (4.1 x 12 mm) in the humerus, being either BSP-AK treated or untreated (machined - control). At 8 weeks postimplantation, bone fragments containing the implants were harvested and processed for histologic and histomorphometric analyses. Bone formation was observed in cortical area and towards the medullary canal associated to approximately 1/3 of implant extension. In most cases, in the medullary area, collagen fiber bundles were detected adjacent and oriented parallel to Ti surfaces. Such connective tissue formation exhibited focal areas of mineralized matrix lined by active osteoblasts. The mean percentages of bone-to-implant contact were 2.3 (0.0-7.2 range) for BSP-AK and 0.4 (0.0-1.3 range) for control. Although the Mann-Whitney test did not detect statistically significant differences between groups, these results indicate a trend of BSP-AK treated surfaces to support contact osteogenesis in an experimental model that produces low bone-to-implant contact values.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

O domínio do Cerrado compreende uma área contínua nos estados centrais do Brasil e áreas disjuntas em outros estados, incluindo São Paulo. Essa vegetação ocupava originalmente 21% do território brasileiro, restando atualmente apenas 21,6% de sua extensão original. A área recoberta por essa vegetação em São Paulo cobria 14% de sua área total e seus remanescentes recobrem menos de 1% da ocorrência original dessa vegetação. Estudos recentes indicam que o valor da produtividade líquida no Cerrado Pé-de-Gigante (SP) constitui um pequeno dreno de carbono e indicou que a sazonalidade foi o fator determinante do valor observado. Os estudos dos fluxos de carbono em ecossistemas terrestres são raramente acompanhados de abordagens ecofisiológicas de modo a explorar a relação funcional das espécies que compõem o ecossistema e os valores líquidos obtidos para o mesmo. Assim, o objetivo deste trabalho foi caracterizar estruturalmente a vegetação presente na área de maior influência da torre de fluxo instalada no Cerrado Pé-de-Gigante, visando possibilitar estudos relacionados à quantificação em longo prazo da dinâmica dos fluxos de água, energia e CO2 na vegetação de Cerrado. Para isso foram levantadas 20 parcelas (10 x 10 m) em 0,2 ha de Cerrado, e amostraram-se todas as plantas com perímetro ao nível do solo >6 cm (exceto lianas e árvores mortas). A distribuição das classes de diâmetro e estrutura vertical, assim como os parâmetros fitossociológicos foram analisados. Encontramos 1451 indivíduos, distribuídos em 85 espécies, 52 gêneros e 31 famílias. A densidade absoluta e área basal foram de 7255 ind. ha-1 e de 7,9 m².ha-1, respectivamente. A família Leguminosae apresentou o maior número de espécies (13). O Índice de diversidade de Shannon (H') foi 3,27 nats.ind-1. A distribuição em classes de diâmetro mostrou uma curva de "J" invertido, estando a maioria dos indivíduos na primeira classe. Concluímos que a área deve ser classificada como Cerrado denso, devido principalmente à dominância pela espécie arbórea Anadenanthera falcata, cuja ocorrência no estado foi relatada apenas em locais com solos ricos em saturação de bases na região das Cuestas Basálticas, devido também à maior área basal dos indivíduos, comparando com outros fragmentos de Cerrado. Além da espécie citada, Myrcia lingua e Xylopia aromatica, apresentaram os maiores IVI (Valor de importância).