210 resultados para Determination of sex


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The flavone C-glucoside, vicenin-2, in semi-purified extracts of the leaves of Lychnophora ericoides was quantified in rat plasma samples using a method based on reversed-phase high performance liquid chromatography coupled to tandem mass spectrometry. Vicenin-2 was analyzed on a LiChrospher (R) RP18 column using an isocratic mobile phase consisting of a mixture of methanol: water (30:70, v/v) plus 2.0% glacial acetic acid at a flow rate of 0.8 mL min(-1). Genistein was used as internal standard. The mass spectrometer was operated in positive ionization mode and analytes were quantified by multiple reaction monitoring at m/z 595 > 457 for vicenin-2 and m/z 271 > 153 for internal standard. Prior to the analysis, each rat plasma sample was acidified with 200 mu L of 50 mmol L(-1) acetic acid solution and extracted by solid-phase extraction using a C18 cartridge. The absolute recoveries were reproducible and the coefficients of variation values were lower than 5.2%. The method was linear over the 12.5 - 1500 ng mL(-1) concentration range and the quantification limit was 12.5 ng mL(-1). Within-day and between-day assay precision and accuracy were studied at three concentration levels (40, 400 and 800 ng mL(-1)) and were lower than 15%. The developed and validated method seems to be suitable for analysis of vicenin-2 in plasma samples obtained from rats that receive a single i.p. dose of 200 mg kg(-1) vicenin-2 extract.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A CE method was developed and validated for the stereoselective determination of midodrine and desglymidodrine in Czapek culture medium to be applied to a stereoselective biotransformation study employing endophytic fungi. The electrophoretic analyses were performed using an uncoated fused-silica capillary and 70 mmol/L sodium acetate buffer solution (pH 5.0) containing 30 mmol/L heptakis (2, 3, 6-tri-O-methyl)-beta-CD as running electrolyte. The applied voltage and temperature used were 15 kV and 15 C, respectively. The UV detector was set at 200 nm. The sample preparation was carried out by liquid-liquid extraction using ethyl acetate as extractor solvent. The method was linear over the concentration range of 0.1-12 mu g/mL for each enantiomer of midodrine and desglymidodrine (r >= 0.9975). Within-day and between-day precision and accuracy evaluated by RSDs and relative errors, respectively, were lower than 15% for all analytes. The method proved to be robust by a fractional factorial design evaluation. The validated method was used to assess the midodrine biotransformation to desglymidodrine by the fungus Phomopsis sp. (TD2), which biotransformed 1.1% of (-)-midodrine to (-)-desglymidodrine and 6.1% of (+)-midodrine to (+)-desglymidodrine.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method for simultaneous determination of seven benzodiazepines (BZPs) (flunitrazepam, clonazepam, oxazepam, lorazepam, chlordiazepoxide, nordiazepam and diazepam using N-desalkylflurazepam as internal standard) in human plasma using liquid-liquid and solid-phase extractions followed by high-performance liquid chromatography (HPLC) is described. The analytes were separated employing a LC-18 DB column (250 mm x 4.6 mm, 5 mu m) at 35 degrees C under isocratic conditions using 5 mM KH(2)PO(4) buffer solution pH 6.0: methanol: diethyl ether (55:40:5, v/v/v) as mobile phase at a flow rate of 0.8 mL min(-1). UV detection was carried out at 245 nm. Employing LLE, the best conditions were achieved with double extraction of 0.5 mL, plasma using ethyl acetate and Na(2)HPO(4) pH 9.5 for pH adjusting. Employing SPE, the best conditions were achieved with 0.5 mL plasma plus 3 mL 0.1 M borate buffer pH 9.5, which were then passed through a C18 cartridge previously conditioned, washed for 3 times with these solvents: 3 mL 0.1 M borate buffer pH 9.5,4 mL Milli-Q water and 1 mL acetonitrile 5%, finally the BZPs elution was carried with diethyl ether: n-hexane: methanol (50:30:20). In both methods the solvent was evaporated at 40 degrees C under nitrogen flow. The validation parameters obtained in LLE were linearity range of 50-1200 ng mL(-1) plasma (r >= 0.9927), limits of quantification of 50 ng mL(-1) plasma, within-day and between-day CV% and E% for precision and accuracy lower than 15%, and recovery above 65% for all BZPs. In SPE, the parameter obtained were linearity range of 30-1200 ng mL(-1) plasma (r >= 0.9900), limits of quantification of 30 ng mL(-1) plasma, within-day and between-day CV% and E% for precision and accuracy lower than 15% and recovery above 55% for all BZPs. These extracting procedures followed by HPLC analysis showed their suitable applicability in order to examine one or more BZPs in human plasma. Moreover, it could be suggested that these procedures might be employed in various analytical applications, in special for toxicological/forensic analysis. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A graphite furnace atomic absorption spectrometric method is proposed for the direct and simultaneous determination of Cd, Cu, and Se in human blood. Samples were diluted 1:10 (v/v) in 0.5% (v/v) HNO(3) + 0.5% (v/v) Triton X-100 solution. For 12 mu L injected sample volume + 5 mu L, of 1000 mg L(-1) Pd(NO(3))(2) + 3 mu L of 1000 mg L(-1) Mg(NO(3))(2), the calculated characteristic masses (mo) were 0.9 pg Cd, 16 pg Cu, and 39 pg Se, which are close to those mo values for single-element conditions for THGA furnace (1.3 pg Cd, 17 pg Cu, and 45 pg Se). Calibration curves with linear correlations better than 0.999 were obtained. The limits of detection (LOD) were 0.03 mu g L(-1) Cd, 0.075 mu g L(-1) Cu and 0.3 mu g L(-1) Se, and the relative standard deviations (n= 12) were 2.5%, 0.3%, and 1.5%, respectively. The method was applied for Cd, Cu, and Se determination in 10 human blood samples and the results were in agreement at the 95% confidence level with those obtained by inductively coupled plasma mass spectrometry. Concentrations of analytes in the selected blood samples varied from 1.7 to 3.2 mu g L(-1) Cd, 700 to 921.7 mu g L(-1) Cu, and from 68.6 to 350 mu g L(-1) Se. The accuracy of the proposed method was also evaluated by an addition-recovery experiment and recoveries of Cd, Cu, and Se added to blood samples ranged from 99-109%, 91-103%,and 93-103%, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple method with a fast sample preparation procedure for total and inorganic mercury determinations in blood samples is proposed based on flow injection cold vapor inductively coupled plasma mass spectrometry (FI-CVICP-MS). Aliquots of whole blood (500 mL) are diluted 1 + 1 v/v with 10.0% v/v tetramethylammonium hydroxide (TMAH) solution, incubated for 3 h at room temperature and then further diluted 1 + 4 v/v with 2.0% v/v HCl. The inorganic Hg was released by online addition of L-cysteine and then reduced to elemental Hg by SnCl(2). On the other hand, total mercury was determined by on-line addition of KMnO(4) and then reduced to elemental Hg by NaBH(4). Samples were calibrated against matrix-matching. The method detection limit was found to be 0.80 mu g L(-1) and 0.08 mu g L(-1) for inorganic and total mercury, respectively. Sample throughput is 20 samples h(-1). The method accuracy is traceable to Standard Reference Material (SRM) 966 Toxic Metals in Bovine Blood from the National Institute of Standards and Technology (NIST). For additional validation purposes, human whole blood samples were analyzed by the proposed method and by an established CV AAS method, with no statistical difference between the two techniques at 95% confidence level on applying the t-test.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes a simple method for mercury speciation in seafood samples by LC-ICP-MS with a fast sample preparation procedure. Prior to analysis, mercury species were extracted from food samples with a solution containing mercaptoethanol, L-cysteine and HCl and sonication for 15 min. Separation of mercury species was accomplished in less than 5 min on a C8 reverse phase column with a mobile phase containing 0.05%-v/v mercaptoethanol, 0.4% m/v L-cysteine and 0.06 mol L(-1) ammonium acetate. The method detection limits were found to be 0.25, 0.20 and 0.1 ng g(-1) for inorganic mercury, ethylmercury and methylmercury, respectively. Method accuracy is traceable to Certified Reference Materials (DOLT-3 and DORM-3) from the National Research Council Canada (NRCC). With the proposed method there is a considerable reduction of the time of sample preparation. Finally, the method was applied for the speciation of mercury in seafood samples purchased from the Brazilian market. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study used for the first time LC-MS/MS for the analysis of mitragynine (MIT), a mu-opioid agonist with antinociceptive and antitussive properties, in rat plasma. Mitragynine and the internal standard (amitriptyline) were extracted from plasma with hexane-isoamyl alcohol and resolved on a Lichrospher (R) RP-SelectB column (9.80 and 12.90 min, respectively). The quantification limit was 0.2 ng/mL within a linear range of 0.2-1000 ng/mL The method was applied to quantify mitragynine in plasma samples of rats (n = 8 per sampling time) treated with a single oral dose of 20 mg/kg. The following pharmacokinetic parameters were obtained (mean): maximum plasma concentration: 424 ng/mL; time to reach maximum plasma concentration: 1.26 h; elimination half-life: 3.85 h, apparent total clearance: 6.35 L/h/kg, and apparent volume of distribution: 37.90 L/kg. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A sensitive, selective, and reproducible in-tube polypyrrole-coated capillary (PPY) solid-phase microextraction and liquid chromatographic method for fluoxetine and norfluoxetine enantiomers analysis in plasma samples has been developed, validated, and further applied to the analysis of plasma samples from elderly patients undergoing therapy with antidepressants. Important factors in the optimization of in-tube SPME efficiency are discussed, including the sample draw/eject volume, draw/eject cycle number, draw/eject flow-rate, sample pH, and influence of plasma proteins. Separation of the analytes was achieved with a Chiralcel OD-R column and a mobile phase consisting of potassium hexafluorophosphate 7.5 mM and sodium phosphate 0.25 M solution, pH 3.0, and acetonitrile (75:25, v/v) in the isocratic mode, at a flow rate of 1.0 mL/min. Detection was carried out by fluorescence absorbance at Ex/Em 230/290 nm. The multifunctional porous surface structure of the PPY-coated film provided high precision and accuracy for enantiomers. Compared with other commercial capillaries, PPY-coated capillary showed better extraction efficiency for all the analytes. The quantification limits of the proposed method were 10 ng/mL for R- and S-fluoxetine, and 15 ng/mL for R- and S-norfluoxetine, with a coefficient of variation lower than 13%. The response of the method for enantiomers is linear over a dynamic range, from the limit of quantification to 700ng/mL, with correlation coefficients higher than 0.9940. The in-tube SPME/LC method can therefore be successfully used to analyze plasma samples from ageing patients undergoing therapy with fluoxetine. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, a fast, non destructive voltammetric method for cocaine detection in acetonitrile medium using a platinum disk electrode chemically modified with cobalt-hexacyanoferrate (CoHCFe) film is described. The deposition of CoHCFe film at platinum disk (working electrode) was carried out in aqueous solution containing NaClO(4) at 0.1 mol L(-1) as supporting electrolite. Stability studies of the film and subsequent voltammetric analysis of cocaine were made in acetonitrile medium with NaClO4 at 0.1 mol L(-1) as supporting electrolite. A reversible interaction between cocaine and CoHCFe at the film produces a proportional decrease of original peak current, due to the formation of a complex between cocaine and cobalt ions, with subsequent partial passivation of the film surface, being the intensity of current decrease used as analytical signal for cocaine. A linear dependence of cocaine detection was carried out in the range from 2.4 x 10 x 4 to 1.5 x 10(-3) mol L(-1), with a linear correlation coefficient of 0.994 and a detection limit of 1.4 x 10 x 4 mol L(-1). The analysis of confiscated samples by the proposed method indicated cocaine levels from 37% to 95% (m/m) and these results were validated by comparison to HPLC technique, being obtained good correlation between both methods. (C) 2009 Elsevier Ireland Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A sensitive and automated method is described for determination of rifampicin in plasma samples for therapeutic drug monitoring by in-tube solid-phase microextraction coupled with liquid chromatography (in-tube SPME/LC). Important factors in the optimization of in-tube SPME are discussed, such as coating type, sample pH, sample draw/eject volume, number of draw/eject cycles, and draw/eject flow rate. Analyte pre-concentrated in the polyethylene glycol phase was directly transferred to the liquid chromatographic column by percolation of the mobile phase, without carryover. The method was linear over the 0.1-100 mu g/mL range, with a linear coefficient value (r(2)) of 0.998. The inter-assay precision presented coefficient of variation <= 1.7%. The effectiveness and practicability of the proposed method are proven by analysis of plasma samples from ageing patients undergoing therapy with rifampicin. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

UV-VIS-Spectrophotometric and spectrofluorimetric methods have been developed and validated allowing the quantification of chloroaluminum phthalocyanine (CIAIPc) in nanocarriers. In order to validate the methods, the linearity, limit of detection (LOD), limit of quantification (LOQ), precision, accuracy, and selectivity were examined according to USP 30 and ICH guidelines. Linearities range were found between 0.50-3.00 mu g.mL(-1) (Y=0.3829 X [CIAIPc, mu g.mL(-1)] + 0.0126; r=0.9992) for spectrophotometry, and 0.05-1.00 mu g.mL(-1) (Y=2.24 x 10(6) X [CIAIPc, mu g.L(-1)] + 9.74 x 10(4); r=0.9978) for spectrofluorimetry. In addition, ANOVA and Lack-of-fit tests demonstrated that the regression equations were statistically significant (p<0.05), and the resulting linear model is fully adequate for both analytical methods. The LOD values were 0.09 and 0.01 mu g.mL(-1), while the LOCI were 0.27 and 0.04 mu g.mL(-1) for spectrophotometric and spectrofluorimetric methods, respectively. Repeatability and intermediate precision for proposed methods showed relative standard deviation (RSD) between 0.58% to 4.80%. The percent recovery ranged from 98.9% to 102.7% for spectrophotometric analyses and from 94.2% to 101.2% for spectrofluorimetry. No interferences from common excipients were detected and both methods were considered specific. Therefore, the methods are accurate, precise, specific, and reproducible and hence can be applied for quantification of CIAIPc in nanoemulsions (NE) and nanocapsules (NC).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Methods. Data from the Beginning and Ending Supportive Therapy for the Kidney (BEST Kidney) study, a prospective observational study from 54 ICUs in 23 countries of critically ill patients with severe AKI, were analysed. The RIFLE class was determined by using observed (o) pre-morbid and estimated (e) baseline SCr values. Agreement was evaluated by correlation coefficients and Bland-Altman plots. Sensitivity analysis by chronic kidney disease (CKD) status was performed. Results. Seventy-six percent of patients (n = 1327) had a pre-morbid baseline SCr, and 1314 had complete data for evaluation. Forty-six percent had CKD. The median (IQR) values were 97 mu mol/L (79-150) for oSCr and 88 mu mol/L (71-97) for eSCr. The oSCr and eSCr determined at ICU admission and at study enrolment showed only a modest correlation (r = 0.49, r = 0.39). At ICU admission and study enrolment, eSCr misclassified 18.8% and 11.7% of patients as having AKI compared with oSCr. Exclusion of CKD patients improved the correlation between oSCr and eSCr at ICU admission and study enrolment (r = 0.90, r = 0.84) resulting in 6.6% and 4.0% being misclassified, respectively. Conclusions. While limited, estimating baseline SCr by the MDRD equation when pre-morbid SCr is unavailable would appear to perform reasonably well for determining the RIFLE categories only if and when pre-morbid GFR was near normal. However, in patients with suspected CKD, the use of MDRD to estimate baseline SCr overestimates the incidence of AKI and should not likely be used. Improved methods to estimate baseline SCr are needed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The potential involvement of SRY in abnormal gonadal development in 45,X/46,X,der(Y) patients was proposed following the identification of SRY mutations in a few patients with Turner syndrome (TS). However, its exact etiological role in gonadal dysgenesis in patients with Y chromosome mosaicisms has not yet been clarified. Aims: It was the aim of this study to screen for allelic variation in SRY in a large cohort of patients with disorders of sex development due to chromosomal abnormalities with 45, X/46, X, der(Y) karyotype. Patients: Twenty-seven patients, 14 with TS and 13 with mixed gonadal dysgenesis (MGD), harboring 45, X/46, X, der(Y) karyotypes were selected. Methods: Genomic DNA was extracted from peripheral blood leukocytes of all patients and from gonadal tissue in 4 cases. The SRY coding region was PCR amplified and sequenced. Results: We identified only 1 polymorphism (c.561C -> T) in a 45,X/46,XY MGD patient, which was detected in blood and in gonadal tissue. Conclusion: Our results indicate that mutations in SRY are rare findings in patients with Y chromosome mosaicisms. Therefore, a significant role of mutated SRY in the etiology of gonadal dysgenesis in patients harboring 45, X/46, XY karyotype and variants seems very unlikely. Copyright (C) 2010 S. Karger AG, Basel

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Neutron activation analysis was applied to assess trace elements concentrations in head hair from healthy elderly people living in the Sao Paulo metropolitan area. Concentrations of As, Br, Ca, Cl, Co, Cr, Cu, Fe, K, La, Mn, Na, Sb, Se and, Zn were determined. Comparisons were made between the results obtained for dyed and non-dyed hair as well as for hair from females and males of two different age groups. The results were also compared with range values established by clinical laboratories and published data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Human biomonitoring (HBM) of environmental contaminants plays an important role in estimating exposure and evaluating risk, and thus it has been increasingly applied in the environmental field. The results of HBM must be compared with reference values ( RV). The term ""reference values"" has always been related to the interpretation of clinical laboratory tests. For physicians, RV indicate ""normal values"" or ""limits of normal""; in turn, toxicologists prefer the terms ""background values"" or ""baseline values"" to refer to the presence of contaminants in biological fluids. This discrepancy leads to the discussion concerning which should be the population selected to determine RV. Whereas clinical chemistry employs an altered health state as the main exclusion criterion to select a reference population ( that is, a ""healthy"" population would be selected), in environmental toxicology the exclusion criterion is the abnormal exposure to xenobiotics. Therefore, the choice of population to determine RV is based on the very purpose of the RV to be determined. The present paper discusses the concepts and methodology used to determine RV for biomarkers of chemical environmental contaminants.