128 resultados para mitral implantation


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate wavefront performance and modulation transfer function (MTF) in the human eye aft er the implantation of diffractive or refractive multifocal intraocular lenses (IOLs). Materials and Methods: This was a prospective, interventional, comparative, nonrandomized clinical study. Uncorrected distance and near visual acuity, and wavefront analysis including MTF curves (iTrace aberrometer, Tracey Technologies, Houston, TX, USA) were measured in 60 patients aft er bilateral IOL implantation with 6 months of follow-up. Forty eyes received the diffractive ReSTOR (Alcon), 40 eyes received the refractive ReZoom (Advanced Medical Optics) and 40 eyes, the Tecnis ZM900 (Advanced Medical Optics). The comparison of MTF and aberration between the intraocular lenses was performed using analysis of variance (ANOVA), followed by the Dunn test when necessary. Results: The mean uncorrected distance visual acuity was similar in all three groups of multifocal IOLs. The ReSTOR group provided better uncorrected near visual acuity than the ReZoom group (P < 0.001), but similar to the Tecnis group. Spherical aberration was significantly higher in the ReZoom group (P = 0.007). Similar MTF curves were found for the aspheric multifocal IOL Tecnis and the spheric multifocal IOL ReSTOR, and both performed better than the multifocal IOL ReZoom in a 5 mm pupil (P < 0.001 at all spatial frequencies). Conclusions: Diffractive IOLs studied presented similar MTF curves for a 5 mm pupil diameter. Both diffractive IOLs showed similar spherical aberration, which was significantly better with the full-diffractive IOL Tecnis than with the refractive IOL ReZoom.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: We tested two novel drug-eluting stents (DES), covered with a biodegradable-polymer carrier and releasing paclitaxel or sirolimus, which were compared against a bare metal stent (primary objective). The DES differed by the drug, but were identical otherwise, allowing to compare the anti-restenosis effects of sirolimus versus paclitaxel (secondary objective). Background: The efficacy of novel DES with biodegradable polymers should be tested in the context of randomized trials, even when using drugs known to be effective, such as sirolimus and paclitaxel. Methods: Overall, 274 patients with de novo coronary lesions in native vessels scheduled for stent implantation were randomly assigned (2:21 ratio) for the paclitaxel (n = 111), sirolimus (n = 106), or bare metal stent (n = 57) groups. Angiographic follow-up was obtained at 9 months and major cardiac adverse events up to 12 months. Results: Both paclitaxel and sirolimus stents reduced the 9-month in-stent late loss (0.54-0.44 mm, 0.32-0.43 mm, vs. 0.90-0.45 mm respectively), and 1-year risk of target vessel revascularization and combined major adverse cardiac events (P < 0.05 for both, in all comparisons), compared with controls. Sirolimus stents had lower late loss than paclitaxel stents (P < 0.01), but similar 1-year clinical outcomes. There were no differences in the risk of death, infarction, or stent thrombosis among the study groups. Conclusion: Both novel DES were effective in reducing neointimal hyperplasia and 1-year re-intervention, compared to bare metal stents. Our findings also suggest that sirolimus is more effective than paclitaxel in reducing angiographic neointima, although this effect was not associated with better clinical outcomes. (C) 2009 Wiley-Liss, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To describe a new suture technique for laryngeal microsurgery and to test its applicability in human cadaver larynges. The new technique was experimentally tested in freshly excised human larynges fixed to a larynx holder appropriate for the simulation of laryngeal microsurgery. A mucosal flap was created in the vocal fold for the fabrication of a pocket for subepithelial fat implantation, and the wound edges were then brought together and sutured using the proposed technique. The time necessary for suture was measured with a stopwatch for five successive sutures performed by one of the surgeons. The presence or absence of mucosal rupture was determined for five sutures performed by two surgeons, for a total of 10 sutures. The sutures were performed without the help of an assistant, with no laceration of the mucosa being observed in any of the attempts, and within a relatively short period of time even without previous training. The sutures performed permitted the implanted fat to remain stable under the mucosal flap. Conclusions: the new suture technique is an easy procedure, which can be performed by a single surgeon under microscopic vision, with a low risk of tissue rupture. The technique does not markedly prolong the duration of surgery and a single suture thread can be used for the fabrication of more than one stitch.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Radiofirequency ablation of the pulmonary veins has been used to treat patients with paroxysmal atrial fibrillation (AF), and atrial damage after ablation is an issue of concern. To evaluate left atrial function shortly and midterm after ablation, 33 consecutive patients with paroxysmal AF were studied at baseline, 24 hours, and >= 6 months after ablation. Patients in sinus rhythm with normal ventricular function were included in the study. Echocardiographic measurements of left atrial volumes (Simpson`s rule) and transmitral and tissue Doppler myocardial (A`) velocities at the septal and lateral mitral annulus were undertaken at each time. Left atrial emptying fraction (EF; maximal - minimal left atrial volume/maximal left atrial volume) was used to express left atrial function. After 8 +/- 2 months, 30 of 33 patients returned (23 men, age 53 +/- 13 years), and all except 2 were in sinus rhythm. Shortly after ablation, left atrial minimal volumes increased (from 30 +/- 15 to 35 +/- 15 ml; p = 0.02), with maximal volumes unchanged, resulting in decreased left atrial EF (from 47 +/- 8 to 40 +/- 7 ml; p <0.05). Tissue Doppler septal A` velocities also decreased (from 8.2 +/- 1.8 to 6.9 +/- 2.0 cm/s; p <0.05). However, after midterm follow-up, both left atrial EF and septal A` velocities had slightly increased compared with shortly after ablation, although left atrial volumes remained similar to baseline. Septal A` velocity changes paralleled left atrial EF both shortly (r = 0.46, p = 0.02) and at midterm after ablation (r = 0.47, p = 0.01). In conclusion, after radiofrequency ablation, patients with paroxysmal AF experienced an initial impairment in atrial function, with improvement at longer term follow-up. (C) 2009 Elsevier Inc. All rights reserved. (Am J Cardiol 2009;103: 395-398)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: There is a paucity of information describing the real-time 3-dimensional echocardiography (RT3DE) and dyssynchrony indexes (DIs) of a normal population. We evaluate the RT3DE DIs in a population with normal electrocardiograms and 2- and 3-dimensional echocardiographic analyses. This information is relevant for cardiac resynchronization therapy. Methods: We evaluated 131 healthy volunteers (73 were male, aged 46 +/- 14 years) who were referred for routine echocardiography; who presented normal cardiac structure on electrocardiography, 2-dimensional echocardiography, and RT3DE; and who had no history of cardiac diseases. We analyzed 3-dimensional left ventricular ejection fraction, left ventricle end-diastolic volume, left ventricle end-systolic volume, and left ventricular systolic DI% (6-, 12-, and 16-segment models). RT3DE data were analyzed by quantifying the statistical distribution (mean, median, standard deviation [SD], relative SD, coefficient of skewness, coefficient of kurtosis, Kolmogorov-Smirnov test, D`Agostino-Pearson test, percentiles, and 95% confidence interval). Results: Left ventricular ejection fraction ranged from 50% to 80% (66.1% +/- 7.1%); left ventricle end-diastolic volume ranged from 39.8 to 145 mL (79.1 +/- 24.9 mL); left ventricle end-systolic volume ranged from 12.9 to 66 mL (27 +/- 12.1 mL); 6-segment DI% ranged from 0.20% to 3.80% (1.21% +/- 0.66%), median: 1.06, relative SD: 0.5482, coefficient of skewness: 1.2620 (P < .0001), coefficient of Kurtosis: 1.9956 (P = .0039); percentile 2.5%: 0.2900, percentile 97.5%: 2.8300; 12-segment DI% ranged from 0.22% to 4.01% (1.29% +/- 0.71%), median: 1.14, relative SD: 0.95, coefficient of skewness: 1.1089 (P < .0001), coefficient of Kurtosis: 1.6372 (P = .0100), percentile 2.5%: 0.2850, percentile 97.5%: 3.0700; and 16-segment DI% ranged from 0.29% to 4.88% (1.59 +/- 0.99), median: 1.39, relative SD: 0.56, coefficient of skewness: 1.0792 (P < .0001), coefficient of Kurtosis: 0.9248 (P = .07), percentile 2.5%: 0.3750, percentile 97.5%: 3.750. Conclusion: This study allows for the quantification of RT3DE DIs in normal subjects, providing a comparison for patients with heart failure who may be candidates for cardiac resynchronization therapy. (J Am Soc Echocardiogr 2008; 21: 1229-1235)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Contrast echocardiography has been demonstrated useful for left ventricular opacification and improvement of endocardial border delineation. Another important clinical application of this technique refers to the better characterization of cardiac tumors and masses. We here described an asymptomatic patient with cystic mass attached to submitral valve apparatus in which contrast echocardiography was performed after intravenous injection of lipid-encapsulated microbubbles. It resulted in enhancement of the cystic borders and allowed for better definition of its diagnosis. Multislice computed tomography confirmed the echocardiographic findings. This case illustrates the potential of contrast echocardiography to improve the anatomic evaluation of cardiac masses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To determine whether implantation of an intraocular lens (IOL) with an aspheric surface (Akreos AO, Bausch & Lomb Inc) results in reduced ocular aberrations (spherical aberration) and improved Strehl ratio and modulation transfer function (MTF) after cataract surgery. METHODS: In an intraindividual, randomized, double-masked, prospective study of 50 eyes (25 patients) with bilateral cataract, an IOL with modified anterior and posterior surfaces (Akreos AO) was implanted in one eye and a biconvex IOL with spherical surfaces (Akreos Fit, Bausch & Lomb Inc) implanted in the fellow eye. Ocular aberrations, Strehl ratio, and MTF curve with 4.5-, 5.0-, and 6.0-mm pupils were measured with a NIDEK OPD-Scan dynamic retinoscopy aberrometer 3 months after surgery. Uncorrected and corrected distance visual acuity (UDVA and CDVA, respectively) were also measured. RESULTS: No statistically significant difference was noted between eyes in postoperative UDVA and CDVA at 1 month. At 3 months, the Akreos AO IOL group obtained statistically significant lower values of higher order and spherical aberrations with 4.5-, 5.0-, and 6.0-mm pupil diameters than the Akreos Fit IOL group (P<.05). The value of Strehl ratio was statistically significantly higher in eyes with the Akreos AO IOL for 4.5- and 6.0-mm pupils (P<.05). The MTF curve was better in the Akreos AO IOL group in 4.5-, 5.0-, and 6.0-mm pupils (P<.05). CONCLUSIONS: The aspheric Akreos AO IOL induced significantly less spherical aberration than the Akreos Fit IOL for 4.5-, 5.0-, and 6.0-mm pupils. Modulation transfer function and Strehl ratio were also better in eyes implanted with the Akreos AO IOL than the Akreos Fit. [J Refract Surg. 2011;27(4):287-292.] doi:10.3928/1081597X-20100714-01

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background-The proximity to vascular structures is a limiting factor during radiofrequency ablation. However, little or no attention has been given to the atrial arterial circulation during the development of atrial fibrillation (AF) catheter ablation techniques. Methods and Results-We examined the atrial arterial circulation in areas involved in AF ablation in 24 heart specimens by colored resin injection and careful dissection. The sinus node artery (SNA) arose from the circumflex artery in 42% of case; proximal to the LA appendage in 29%, crossing the left atrium (LA) anterior wall; and after the LA appendage in the remaining 13%, crossing the mitral isthmus and passing close to the left pulmonary veins (PVs), the LA roof, and the right superior PV. In 58%, the SNA arose from the right coronary artery. Major arteries (>= 1 mm in external diameter) were found in the mitral isthmus in 54%, at the LA roof in 54%, and at the LA anterior wall in 29%. Around the left PV ostia, there were areas with major arteries in up to 37% (at the roof and inferior segments) and around the right PV ostia in up to 29% (at the roof segment). Conclusions-Major atrial coronary arteries, including the SNA, were commonly found in the areas involved in AF ablation and could cause difficulties in obtaining transmural lesions and electric isolation or even lead to ischemic sinus node or atrial dysfunction. (Circ Arrhythm Electrophysiol. 2010;3:600-605.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims: There remains significant concern about the long-term safety of drug-eluting stents (DES). However, bare metal stents (BMS) have been used safely for over two decades. There is therefore a pressing need to explore alternative strategies for reducing restenosis with BMS. This study was designed to examine whether IVUS-guided cutting balloon angioplasty (CBA) with BMS could convey similar restenosis rates to DES. Methods and results: In the randomised REstenosis reDUction by Cutting balloon angioplasty Evaluation (REDUCE III) study, 521 patients were divided into four groups based on device and IVUS use before BMS (IVUS-CBA-BMS: 137 patients; Angio-CBA-BMS: 123; IVUS-BA-BMS: 142; and Angio-BA-BMS: 119). At follow-up, the IVUS-CBA-BMS group had a significantly lower restenosis rate (6.6%) than the other groups (p=0.016). We performed a quantitative coronary angiography (QCA) based matched comparison between an IVUS-guided CBA-BMS strategy (REDUCE III) and a DES strategy (Rapamycin-Eluting-Stent Evaluation At Rotterdam Cardiology. Hospital, the RESEARCH study). We matched the presence of diabetes, vessel size, and lesion severity by QCA. Restenosis (>50% diameter stenosis at follow-up) and target vessel revascularisation (TVR) were examined. QCA-matched comparison resulted in 120-paired lesions. While acute gain was significantly greater in IVUS-CBA-BMS than DES (1.65 +/- 0.41 mm vs. 1.28 +/- 0.57 mm, p=0.001), late loss was significantly less with DES than with IVUS-CBA-BMS (0.03 +/- 0.42 mm vs. 0.80 +/- 0.47 mm, p=0.001). However, no difference was found in restenosis rates (IVUS-CBA-BMS: 6.6% vs. DES: 5.0%, p=0.582) and TVR (6.6% and 6.6%, respectively). Conclusions: An IVUS-guided CBA-BMS strategy yielded restenosis rates similar to those achieved by DES and provided an effective alternative to the use of DES.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: During the past 15 years, polymethylmethacrylate has been used as a synthetic permanent filler for soft-tissue augmentation. Methods: This. article reports 32 cases of complications seen at Hospital das Clinicas, Faculty of Medicine, University of Sao Paulo, for procedures performed elsewhere. Results: The average age of the patients was 43.6 years (range, 22 to 70 years). Twenty-five patients were women. Sixteen injection procedures were performed by certified plastic surgeons, nine by dermatologists, two by urologists, and one by a nonphysician. Complications were classified into five groups according to main presentation as follows: tissue necrosis (five cases), an acute complication that can be related to technical mistakes but that can also be dependent on patient factors or caused by local infection; granuloma (10 cases), which usually presents as a subacute complication 6 to 12 months after the procedure; chronic inflammatory reactions (10 cases), which usually occur years later and can be related to a triggering event, Such as another operation or infection in the area that was injected (these reactions are immunogenic in origin and may have cyclic periods of activation and remission); chronic inflammatory reaction in the lips (six cases), which may be present with severe symptoms, especially with lymphedema, because of mobility of the lip; and infections (one case), which are rare but possible complications after filling procedures. Conclusions: Polymethylmethacrylate filler complications, despite being rare, are often permanent and difficult or even impossible to treat. Safety guidelines should be observed when considering use of polymethylmethacrylate for augmentation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To analyze in an experimental animal model the effect of 4 different levels of stents-graft oversizing on non-atherosclerotic aortas such as those found in young individuals who undergo stent-graft repair for traumatic aortic injuries. Methods: The diameter of the porcine thoracic aorta is similar to the aorta of young adults (18-20 mm), so 25 pigs were randomized into 5 groups: 1 control (without stent-graft) and 4 oversizing groups (A: 10%-19%, B: 20%-29%, C: 30%-39%, and D: >40%). Two types of biomechanical tests were performed on all aortas 4 weeks after endoprosthesis deployment. Results: The results of the detachment test, which analyzed the strength necessary to remove the stent-graft from the aorta, were similar in the 4 groups (A: 42 N, B: 41 N, C: 46 N, and D: 46 N). However, 2 aortas ruptured during the tests (groups C and D). The second test was performed in 3 aortic segments. Maximum shear strength, maximum stress, and maximum tension supported by the aortic wall had a negative and linear correlation with oversizing. There were significant differences in all 4 groups when compared with the control group. Strain, which reflects the elastic properties of the aortic wall, was very similar in all 4 groups, but a great difference was found when compared with the control group (p<0.0001). Conclusion: The study showed an important subacute change in the biomechanical properties of the aortic wall after implantation of an oversized endoprosthesis. This weakness of the aortic wall was confirmed by 2 ruptures during the detachment test. These results partially explain the interaction of stent-grafts with non-atherosclerotic thoracic aortas and may serve as a basis for further studies and the development of specific material to be used in vascular trauma and young patients. J Endovasc Ther. 2011; 18: 576-584

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction. Advantages of the bicaval versus the biatrial technique have been reported, emphasizing atrial electrical stability and less tricuspid regurgitation. Objective. To analyze the impact of the surgical technique on long-term pulmonary pressures, contractility, and graft valvular behavior after heart transplantation. Methods. Among 400 orthotopic heart transplantation recipients from 1985 to 2010, we selected 30 consecutive patients who had survived beyond 3 years. The biatrial versus bicaval surgical technique groups included 15 patients each. Their preoperative clinical characteristics were similar. None of the patients displayed a pulmonary vascular resistance or pulmonary artery pressure over 6U Wood or 60 mm Hg, respectively. We evaluated invasive hemodynamic parameters during routine endomyocardial biopsies. Two-dimensional echocardiographic parameters were obtained from routine examinations. Results. There were no significant differences regarding right atrial pressure, systolic pulmonary artery pressure, pulmonary capillary wedge pressure, pulmonary vascular resistance, cardiac index, systolic blood pressure, left ventricular ejection fraction, and mitral regurgitation (P > .05). Tricuspid regurgitation increased significantly over the 3 years of observation only among the biatrial group (P = .0212). In both groups, the right atrial pressure, pulmonary wedge capillary pressure, transpulmonary gradient, and pulmonary vascular resistance decreased significantly (P < .05) from the pre- to the postoperative examination. In both groups cardiac index and systemic blood pressure increased significantly after transplantation (P < .05). Comparative analysis of the groups only showed significant differences regarding right atrial pressure and degree of tricuspid regurgitation; the bicaval group showing the best performance. Conclusions. Both surgical techniques ensure adequate left ventricular function in the long term; however, the bicaval technique provided better trends in hemodynamic performance, as well as a lower incidence and severity of tricuspid valve dysfunction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To determine reference values for tissue Doppler imaging (TDI) and pulsed Doppler echocardiography for left ventricular diastolic function analysis in a healthy Brazilian adult population. Observations were based on a randomly selected healthy population from the city of Vitoria, Espirito Santo, Brazil. Healthy volunteers (n = 275, 61.7% women) without prior histories of cardiovascular disease underwent transthoracic echocardiography. We analyzed 175 individuals by TDI and evaluated mitral annulus E`- and A`-waves from the septum (S) and lateral wall (L) to calculate E`/A` ratios. Using pulsed Doppler echocardiography, we further analyzed the mitral E- and A-waves, E/A ratios, isovolumetric relaxation times (IRTs), and deceleration times (DTs) of 275 individuals. Pulsed Doppler mitral inflow mean values for men were as follows: E-wave: 71 +/- 16 cm/sec, A-wave: 68 +/- 15 cm/sec, IRT: 74.8 +/- 9.2 ms, DT: 206 +/- 32.3 ms, E/A ratio: 1.1 +/- 0.3. Pulsed Doppler mitral inflow mean values for women were as follows: E-wave: 76 +/- 17, A-wave: 69 +/- 14 cm/sec, IRT: 71.2 +/- 10.5 ms, DT: 197 +/- 33.3 ms, E/A ratio: 1.1 +/- 0.3. IRT and DT values were higher in men than in women (P = 0.04 and P = 0.007, respectively). TDI values in men were as follows: E`S: 11 +/- 3 cm/sec, A`S: 13 +/- 2 cm/sec, E`S/A`S: 0.89 +/- 0.2, E`L: 14 +/- 3 cm/sec, A`L: 14 +/- 2 cm/sec, E`L/A`L: 1.1 +/- 0.4. E-wave/ E`S ratio: 6.9 +/- 2.2; E-wave / E`L ratio: 4.9 +/- 1.7. In this study, we determined pulsed Doppler and TDI derived parameters for left ventricular diastolic function in a large sample of healthy Brazilian adults. (Echocardiography 2010;27:777-782).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Worsening in clinical and cardiac status has been noted after chronic right ventricular pacing, but it is uncertain whether atriobiventricular (BiVP) is preferable to atrio-right ventricular pacing (RVP). Conventional versus Multisite Pacing for BradyArrhythmia Therapy study (COMBAT) sought to compare BiVP versus RVP in patients with symptomatic heart failure (HF) and atrioventricular (AV) block. Methods and Results: COMBAT is a prospective multicenter randomized double blind crossover study. Patients with New York Heart Association functional class (FC) II-IV, left ventricular ejection fraction (LVEF) <40%, and AV block as an indication for pacing were enrolled. All patients underwent biventricular system implantation and then were randomized to receive successively (group A) RVP-BiVP-RVP, or (group B) BiVP-RVP-BiVP. At the end of each 3-month crossover period, patients were evaluated according to Quality of Life (QoL), FC, echocardiographic parameters, 6-Minute Walk Test (6MWT), and peak oxygen consumption (VO(2max)). Sixty patients were enrolled, and the mean follow-up period was 17.5 +/- 10.7 months. There were significant improvements in QoL, FC, LVEF, and left ventricular end-systolic volume with BiVP compared with RVP. The effects of pacing mode on 6MWT and VO(2max) were not significantly different. Death occurred more frequently with RVP. Conclusion: In patients with systolic HF and AV block requiring permanent ventricular pacing, BiVP is superior to RVP and should be considered the preferred pacing mode. (J Cardiac Fail 2010;16:293-300)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Endomyocardial fibrosis (EMF) is a restrictive cardiomyopathy manifested mainly by diastolic heart failure. It is recognized that diastole is an important determinant of exercise capacity. The purpose of this study was to determine whether resting echocardiographic parameters might predict oxygen consumption (VO(2p)) by ergoespirometry and the prognostic role of functional capacity in EMF patients. A total of 32 patients with biventricular EMF (29 women, 55.3 +/- 11.4 years) were studied by echocardiography and ergoespirometry. The relationship between the echocardiographic indexes and the percentage of predicted VO(2p) (%VO(2p)) was investigated by the `stepwise` linear regression analysis. The median VO(2p) was 11 +/- 3 mL/kg/min and the %VO(2p) was 53 +/- 9%. There was a correlation of %VO(2p) with an average of A` at four sites of the mitral annulus (A` peak, r = 0.471, P = 0.023), E`/A` of the inferior mitral annulus (r = -0.433, P = 0.044), and myocardial performance index (r = -0.352, P = 0.048). On multiple regression analysis, only A` peak was an independent predictor of %VO(2p) (%VO(2p)= 26.34 + 332.44 x A` peak). EMF patients with %VO(2p)< 53% had an increased mortality rate with a relative risk of 8.47. In EMF patients, diastolic function plays an important role in determining the limitations to exercise and %VO(2p) has a prognostic value.