Standard Values for Real-Time Transthoracic Three-Dimensional Echocardiographic Dyssynchrony Indexes in a Normal Population
Contribuinte(s) |
UNIVERSIDADE DE SÃO PAULO |
---|---|
Data(s) |
19/10/2012
19/10/2012
2008
|
Resumo |
Background: There is a paucity of information describing the real-time 3-dimensional echocardiography (RT3DE) and dyssynchrony indexes (DIs) of a normal population. We evaluate the RT3DE DIs in a population with normal electrocardiograms and 2- and 3-dimensional echocardiographic analyses. This information is relevant for cardiac resynchronization therapy. Methods: We evaluated 131 healthy volunteers (73 were male, aged 46 +/- 14 years) who were referred for routine echocardiography; who presented normal cardiac structure on electrocardiography, 2-dimensional echocardiography, and RT3DE; and who had no history of cardiac diseases. We analyzed 3-dimensional left ventricular ejection fraction, left ventricle end-diastolic volume, left ventricle end-systolic volume, and left ventricular systolic DI% (6-, 12-, and 16-segment models). RT3DE data were analyzed by quantifying the statistical distribution (mean, median, standard deviation [SD], relative SD, coefficient of skewness, coefficient of kurtosis, Kolmogorov-Smirnov test, D`Agostino-Pearson test, percentiles, and 95% confidence interval). Results: Left ventricular ejection fraction ranged from 50% to 80% (66.1% +/- 7.1%); left ventricle end-diastolic volume ranged from 39.8 to 145 mL (79.1 +/- 24.9 mL); left ventricle end-systolic volume ranged from 12.9 to 66 mL (27 +/- 12.1 mL); 6-segment DI% ranged from 0.20% to 3.80% (1.21% +/- 0.66%), median: 1.06, relative SD: 0.5482, coefficient of skewness: 1.2620 (P < .0001), coefficient of Kurtosis: 1.9956 (P = .0039); percentile 2.5%: 0.2900, percentile 97.5%: 2.8300; 12-segment DI% ranged from 0.22% to 4.01% (1.29% +/- 0.71%), median: 1.14, relative SD: 0.95, coefficient of skewness: 1.1089 (P < .0001), coefficient of Kurtosis: 1.6372 (P = .0100), percentile 2.5%: 0.2850, percentile 97.5%: 3.0700; and 16-segment DI% ranged from 0.29% to 4.88% (1.59 +/- 0.99), median: 1.39, relative SD: 0.56, coefficient of skewness: 1.0792 (P < .0001), coefficient of Kurtosis: 0.9248 (P = .07), percentile 2.5%: 0.3750, percentile 97.5%: 3.750. Conclusion: This study allows for the quantification of RT3DE DIs in normal subjects, providing a comparison for patients with heart failure who may be candidates for cardiac resynchronization therapy. (J Am Soc Echocardiogr 2008; 21: 1229-1235) |
Identificador |
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, v.21, n.11, p.1229-1235, 2008 0894-7317 http://producao.usp.br/handle/BDPI/21308 10.1016/j.echo.2008.08.003 |
Idioma(s) |
eng |
Publicador |
MOSBY-ELSEVIER |
Relação |
Journal of the American Society of Echocardiography |
Direitos |
restrictedAccess Copyright MOSBY-ELSEVIER |
Palavras-Chave | #Cardiac synchronicity #Normal population #Standard values #Tridimensional echocardiography #CARDIAC RESYNCHRONIZATION THERAPY #LEFT-VENTRICULAR DYSSYNCHRONY #CHRONIC HEART-FAILURE #MYOCARDIAL-INFARCTION #CARDIOMYOPATHY #SYNCHRONICITY #BENEFIT #QUANTIFICATION #IMPLANTATION #STIMULATION #Cardiac & Cardiovascular Systems |
Tipo |
article original article publishedVersion |