118 resultados para Objective measurement
Resumo:
The objective of this research is to identify the benefits of ergonomic improvements in workstations and in planned parts supply in an automotive assembly line. Another aim is to verify to what extent it is possible to create competitive advantages in the manufacturing area with reduction in vehicle assembly time by using technological investments in ergonomics with benefits to the worker and to the company. The Methods Time Measurement (MTM) methodology is chosen to measure the process time differences. To ensure a reliable comparison, a company in Brazil that has two different types of assembly line installations in the same plant was observed, and both assembly lines were under the same influences in terms of human resources, wages, food, and educational level of the staff. In this article, the first assembly line is called ""new"" and was built 6 years ago, with high investments in ergonomic solutions, in the supply system, and in the process. The other is called ""traditional"" and was built 23 years ago with few investments in the area. (C) 2010 Wiley Periodicals, Inc.
Resumo:
Void fraction sensors are important instruments not only for monitoring two-phase flow, but for furnishing an important parameter for obtaining flow map pattern and two-phase flow heat transfer coefficient as well. This work presents the experimental results obtained with the analysis of two axially spaced multiple-electrode impedance sensors tested in an upward air-water two-phase flow in a vertical tube for void fraction measurements. An electronic circuit was developed for signal generation and post-treatment of each sensor signal. By phase shifting the electrodes supplying the signal, it was possible to establish a rotating electric field sweeping across the test section. The fundamental principle of using a multiple-electrode configuration is based on reducing signal sensitivity to the non-uniform cross-section void fraction distribution problem. Static calibration curves were obtained for both sensors, and dynamic signal analyses for bubbly, slug, and turbulent churn flows were carried out. Flow parameters such as Taylor bubble velocity and length were obtained by using cross-correlation techniques. As an application of the void fraction tested, vertical flow pattern identification could be established by using the probability density function technique for void fractions ranging from 0% to nearly 70%.
Resumo:
The elastic mechanical behavior of elastic materials is modeled by a pair of independent constants (Young`s modulus and Poisson`s coefficient). A precise measurement for both constants is necessary in some applications, such as the quality control of mechanical elements and standard materials used for the calibration of some equipment. Ultrasonic techniques have been used because wave velocity depends on the elastic properties of the propagation medium. The ultrasonic test shows better repeatability and accuracy than the tensile and indentation test. In this work, the theoretical and experimental aspects related to the ultrasonic through-transmission technique for the characterization of elastic solids is presented. Furthermore, an amorphous material and some polycrystalline materials were tested. Results have shown an excellent repeatability and numerical errors that are less than 3% in high-purity samples.
Resumo:
Three-dimensional modeling of piezoelectric devices requires a precise knowledge of piezoelectric material parameters. The commonly used piezoelectric materials belong to the 6mm symmetry class, which have ten independent constants. In this work, a methodology to obtain precise material constants over a wide frequency band through finite element analysis of a piezoceramic disk is presented. Given an experimental electrical impedance curve and a first estimate for the piezoelectric material properties, the objective is to find the material properties that minimize the difference between the electrical impedance calculated by the finite element method and that obtained experimentally by an electrical impedance analyzer. The methodology consists of four basic steps: experimental measurement, identification of vibration modes and their sensitivity to material constants, a preliminary identification algorithm, and final refinement of the material constants using an optimization algorithm. The application of the methodology is exemplified using a hard lead zirconate titanate piezoceramic. The same methodology is applied to a soft piezoceramic. The errors in the identification of each parameter are statistically estimated in both cases, and are less than 0.6% for elastic constants, and less than 6.3% for dielectric and piezoelectric constants.
Resumo:
Real-time viscosity measurement remains a necessity for highly automated industry. To resolve this problem, many studies have been carried out using an ultrasonic shear wave reflectance method. This method is based on the determination of the complex reflection coefficient`s magnitude and phase at the solid-liquid interface. Although magnitude is a stable quantity and its measurement is relatively simple and precise, phase measurement is a difficult task because of strong temperature dependence. A simplified method that uses only the magnitude of the reflection coefficient and that is valid under the Newtonian regimen has been proposed by some authors, but the obtained viscosity values do not match conventional viscometry measurements. In this work, a mode conversion measurement cell was used to measure glycerin viscosity as a function of temperature (15 to 25 degrees C) and corn syrup-water mixtures as a function of concentration (70 to 100 wt% of corn syrup). Tests were carried out at 1 MHz. A novel signal processing technique that calculates the reflection coefficient magnitude in a frequency band, instead of a single frequency, was studied. The effects of the bandwidth on magnitude and viscosity were analyzed and the results were compared with the values predicted by the Newtonian liquid model. The frequency band technique improved the magnitude results. The obtained viscosity values came close to those measured by the rotational viscometer with percentage errors up to 14%, whereas errors up to 96% were found for the single frequency method.
Resumo:
This work presents the implementation of the ultrasonic shear reflectance method for viscosity measurement of Newtonian liquids using wave mode conversion from longitudinal to shear waves and vice versa. The method is based on the measurement of the complex reflection coefficient (magnitude and phase) at a solid-liquid interface. The implemented measurement cell is composed of an ultrasonic transducer, a water buffer, an aluminum prism, a PMMA buffer rod, and a sample chamber. Viscosity measurements were made in the range from 1 to 3.5 MHz for olive oil and for automotive oils (SAE 40, 90, and 250) at 15 and 22.5 degrees C, respectively. Moreover, olive oil and corn oil measurements were conducted in the range from 15 to 30 degrees C at 3.5 and 2.25 MHz, respectively. The ultrasonic measurements, in the case of the less viscous liquids, agree with the results provided by a rotational viscometer, showing Newtonian behavior. In the case of the more viscous liquids, a significant difference was obtained, showing a clear non-Newtonian behavior that cannot be described by the Kelvin-Voigt model.
Resumo:
Nanomaterials have triggered excitement in both fundamental science and technological applications in several fields However, the same characteristic high interface area that is responsible for their unique properties causes unconventional instability, often leading to local collapsing during application Thermodynamically, this can be attributed to an increased contribution of the interface to the free energy, activating phenomena such as sintering and grain growth The lack of reliable interface energy data has restricted the development of conceptual models to allow the control of nanoparticle stability on a thermodynamic basis. Here we introduce a novel and accessible methodology to measure interface energy of nanoparticles exploiting the heat released during sintering to establish a quantitative relation between the solid solid and solid vapor interface energies. We exploited this method in MgO and ZnO nanoparticles and determined that the ratio between the solid solid and solid vapor interface energy is 11 for MgO and 0.7 for ZnO. We then discuss that this ratio is responsible for a thermodynamic metastable state that may prevent collapsing of nanoparticles and, therefore, may be used as a tool to design long-term stable nanoparticles.
Resumo:
The cost of a new ship design heavily depends on the principal dimensions of the ship; however, dimensions minimization often conflicts with the minimum oil outflow (in the event of an accidental spill). This study demonstrates one rational methodology for selecting the optimal dimensions and coefficients of form of tankers via the use of a genetic algorithm. Therein, a multi-objective optimization problem was formulated by using two objective attributes in the evaluation of each design, specifically, total cost and mean oil outflow. In addition, a procedure that can be used to balance the designs in terms of weight and useful space is proposed. A genetic algorithm was implemented to search for optimal design parameters and to identify the nondominated Pareto frontier. At the end of this study, three real ships are used as case studies. [DOI:10.1115/1.4002740]
Resumo:
Aims: We aimed to evaluate if the co-localisation of calcium and necrosis in intravascular ultrasound virtual histology (IVUS-VH) is due to artefact, and whether this effect can be mathematically estimated. Methods and results: We hypothesised that, in case calcium induces an artefactual coding of necrosis, any addition in calcium content would generate an artificial increment in the necrotic tissue. Stent struts were used to simulate the ""added calcium"". The change in the amount and in the spatial localisation of necrotic tissue was evaluated before and after stenting (n=17 coronary lesions) by means of a especially developed imaging software. The area of ""calcium"" increased from a median of 0.04 mm(2) at baseline to 0.76 mm(2) after stenting (p<0.01). In parallel the median necrotic content increased from 0.19 mm(2) to 0.59 mm(2) (p<0.01). The ""added"" calcium strongly predicted a proportional increase in necrosis-coded tissue in the areas surrounding the calcium-like spots (model R(2)=0.70; p<0.001). Conclusions: Artificial addition of calcium-like elements to the atherosclerotic plaque led to an increase in necrotic tissue in virtual histology that is probably artefactual. The overestimation of necrotic tissue by calcium strictly followed a linear pattern, indicating that it may be amenable to mathematical correction.
Resumo:
This paper analyzes the complexity-performance trade-off of several heuristic near-optimum multiuser detection (MuD) approaches applied to the uplink of synchronous single/multiple-input multiple-output multicarrier code division multiple access (S/MIMO MC-CDMA) systems. Genetic algorithm (GA), short term tabu search (STTS) and reactive tabu search (RTS), simulated annealing (SA), particle swarm optimization (PSO), and 1-opt local search (1-LS) heuristic multiuser detection algorithms (Heur-MuDs) are analyzed in details, using a single-objective antenna-diversity-aided optimization approach. Monte- Carlo simulations show that, after convergence, the performances reached by all near-optimum Heur-MuDs are similar. However, the computational complexities may differ substantially, depending on the system operation conditions. Their complexities are carefully analyzed in order to obtain a general complexity-performance framework comparison and to show that unitary Hamming distance search MuD (uH-ds) approaches (1-LS, SA, RTS and STTS) reach the best convergence rates, and among them, the 1-LS-MuD provides the best trade-off between implementation complexity and bit error rate (BER) performance.
Resumo:
The objective of this study was to evaluate the effects of dietary addition of ground oilseed sources on the quality, fatty acid profile, and CLA content of meat from zebu steers. Thirty-one zebu steers with an initial average age of 23 mo and an initial BW of 365 kg were used in this study. The experimental period was 84 d, which was preceded by an adaption period of 28 d. The diet was provided ad libitum with a forage: concentrate ratio of 40:60. Corn silage was used as the forage source. Four different concentrates were formulated for each treatment: without additional lipids (control) or with ground soybeans (SB), ground cottonseed (CS), or ground linseed (LS). The SB, CS, and LS diets were formulated to have 6.5% ether extract on a total dietary DM basis. The experiment was set up as a completely randomized design. After slaughter, samples were taken from the longissimus thoracis muscle for the measurement of fatty acid concentration and the evaluation of meat quality. The luminosity index was greater in the control and LS diets (P < 0.01). The greatest percentages of myristic acid (C14:0), palmitic acid (C16:0), trans octadecenoic acid (C18:1 trans-10, trans-11, or trans-12), and SFA in the subcutaneous fat were observed in the CS treatment (P < 0.01). Moreover, the least percentages of oleic acid (C18:1 cis-9) and total unsaturated fatty acids in the subcutaneous fat were observed in the CS diet (P < 0.01). The meat linoleic acid and a-linolenic acid percentages were greatest in the SB and LS treatments, respectively (P < 0.001). The unsaturated fatty acid: SFA ratio was smallest for the CS diet (P < 0.01). A gradual increase in oxidation was observed as a function of storage time; however, the diets did not affect the rancidity of the meat (P > 0.05). The fatty acid profile of subcutaneous fat was impaired by the addition of CS. Supplying ground oilseeds did not increase the content of CLA in the meat.
Resumo:
Objective: Fat-free mass (FFM) reduction and the tendency for a reduction in surrounding fatty issue and increase in the middle are a natural consequence of growing old and should be studied in order to gain a better understanding of the aging process. This study set out to find the FFM differences between active elderly women in two age groups (60-69 and 70-80 years) and to determine which of the anthropometric measurements, body weight (BW), abdominal circumference (AC), or body mass index (BMI) are the best predictors of FFM variation within the group. Methods: Eighty-one (n = 81) active elderly women of the Third Age willingly signed up to participate in the research during the activities at the University of the Third Age (UTA) in Brazil. The research was approved by the Research Ethics Committee of the Faculty of Medical Sciences of the State University of Campinas (UNICAMP). Body weight (BW), height (H) and the BMI were measured according to the international standards. The AC was measured in centimetres at the H of the navel and body composition was ascertained using bioimpedance analysis. The SAS program was used to perform the statistical analysis of independent samples and parametric data. Results: The results showed FFM values with significant differences between the two groups, with the lowest values occurring among the women who were over 70 years of age. In the analysis, the Pearson`s Correlation Coefficient for each measured independent variable was ascertained, with the BW measurement showing the highest ratio (0.900). Conclusions: The BW measurement was regarded as reliable, low-cost and easy to use for monitoring FFM in elderly women who engage in physical activities. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Discussion opposing the Theory of the Firm to the Theory of Stakeholders are contemporaneous and polemical. One focal point of such debates refers to which objective-function companies, should choose, whether that of the shareholders or that of the stakeholders, and whether it is possible to opt for both simultaneously. Several empirical studies. have attempted-to test a possible correlation between both functions, and there has not been any consensus-so far. The objective of the present research is to examine a gap in such discussions: is there (or not) a subordination of the stakeholders` objective-function to that of the shareholders? The research is empirical,and analytical and employs quantitative methods. Hypotheses were tested and data analyzed by using non-parametrical (chi-square test) and parametrical procedures (frequency. correlation `coefficient). Secondary data was collected from he Economitica database and from the Brazilian Institute of Social and-Economic Analyses (IBASE) website, relative to public companies that have published their Social Balance Statements following the IBASE model from 1999 to 2006, whose sample amounted to 65 companies; In order to assess the objective-function of shareholders a proxy was created based on the following three indices: ROE (return on equity), EnterpriseValue and Tobin`s Q. In order to assess the objective-function of stakeholders a proxy was created by employing the following IBASE social balance indices: internal ones (ISI), external ones (ISE), and environmental ones (IAM). The results have shown no evidence of subordination of stakeholders` objective-function to that of the shareholders in analyzed companies, negating initial expectations and calling for deeper investigation of results. Its main conclusion, which states that the attempted subordination does not take place, is limited to the sample herein investigated and calls for ongoing research aiming at improvements which may lead to sample enlargement and, as a consequence, may make feasible the application of other statistical techniques which may yield a more thorough, analysis of the studied phenomehon.
Resumo:
BACKGROUND AND OBJECTIVE: To compare the analgesic effectiveness and aesthetic appearance associated with topical, subconjunctival, and peribulbar anesthesia for intravitreal bevacizumab injection. PATIENTS AND METHODS: Sixty consecutive patients undergoing their first intravitreal bevacizumab injection were randomized to receive one of three forms of anesthesia: proxymetacaine eye drops, subconjunctival injection of 2% xylocaine, and peribulbar injection of 2% xylocaine. Pain associated with the intravitreal injection and with the entire procedure (including anesthesia administration) was recorded using a Visual Analog Scale 15 minutes after intravitreal injection. Anterior segment evaluation was performed 24 hours after injection to measure the number of clock hours of subconjunctival hemorrhage. RESULTS: Median injection-related pain score was significantly lower in the peribulbar group compared with the topical and subconjunctival groups (P < .05). Median entire procedure pain score was significantly higher In the peribulbar group compared with the topical and subconjunctival groups (P < .05). The median extent of subconjunctival hemorrhage was significantly lower in the topical group compared with the other groups (P < .05). CONCLUSION: Among the three anesthetic techniques, peribulbar anesthesia was associated with greater effectiveness in controlling injection-related pain but was least effective in controlling entire procedure pain. There was no significant difference in pain scores between the topical and subconjunctival groups, and topical anesthesia was associated with less subconjunctival hemorrhage.