82 resultados para Continuous functions


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The population structure, reproductive period, and juvenile recruitment of Panopeus americanus were studied in order to enhance knowledge of its life cycle and reproductive strategy and promote the maintenance of its natural stocks in an impacted region. Specimens were collected in the remnant human-impacted mangrove at Araca, state of Sao Paulo, Brazil, at two-month intervals from January to November 2005, at low tide, with a capture effort by three people. The crabs were measured (carapace width, CW) and sexed. The total catch was 275 animals, including 132 males (48.0%); 127 females (46.2%), of which 39 were ovigerous (14.2% of total catch); and 16 individuals whose sex could not be identified (5.8%). No correlation was observed between water temperature and the number of collected individuals; however, there was a significant, positive correlation with salinity. Males were significantly larger than females. The size-frequency distribution was bimodal, reflecting the occurrende of more than one recruitment pulse and the differential abundance of adults during the period of study. The overall sex ratio was 1:0.97 favoring males, and was not significantly different from the expected value, i.e., this population fits the anomalous pattern of sex occurrence in size classes. Ovigerous females were captured in all sampled months, which explain the continuous recruitment observed. Expected low levels of individuals of different size classes in the population were not confirmed. All population aspects found here allowed us to infer that this population of P. americanus is well established in the impacted mangrove by virtue of its reproductive strategy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A bounded continuous function it u : [0, infinity) -> X is said to be S-asymptotically omega-periodic if lim(t ->infinity)[u(t + omega) - u(t)] = 0. This paper is devoted to study the existence and qualitative properties of S-asymptotically omega-periodic mild solutions for some classes of abstract neutral functional differential equations with infinite delay, Furthermore, applications to partial differential equations are given.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A long-standing challenge of content-based image retrieval (CBIR) systems is the definition of a suitable distance function to measure the similarity between images in an application context which complies with the human perception of similarity. In this paper, we present a new family of distance functions, called attribute concurrence influence distances (AID), which serve to retrieve images by similarity. These distances address an important aspect of the psychophysical notion of similarity in comparisons of images: the effect of concurrent variations in the values of different image attributes. The AID functions allow for comparisons of feature vectors by choosing one of two parameterized expressions: one targeting weak attribute concurrence influence and the other for strong concurrence influence. This paper presents the mathematical definition and implementation of the AID family for a two-dimensional feature space and its extension to any dimension. The composition of the AID family with L (p) distance family is considered to propose a procedure to determine the best distance for a specific application. Experimental results involving several sets of medical images demonstrate that, taking as reference the perception of the specialist in the field (radiologist), the AID functions perform better than the general distance functions commonly used in CBIR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The objective of this study was to compare bleeding patterns of women using a contraceptive combination of 30 mcg ethinylestradiol (EE) and 3 mg drospirenone (DRSP) continuously or cyclically. Menstrual-related symptoms were also evaluated. Study Design: This open, prospective, randomized study evaluated 78 women using the EE/DRSP combination continuously for 168 days or for six 28-day cycles, each followed by a 7-day hormone-free interval. A diary with pre-established scales was used to assess the frequency and intensity of bleeding and menstrual-related symptoms. Results: Amenorrhea increased with continuous use; 62.2% of women with continuous use were amenorrheic at the end of treatment (95% CI: 46.6-77.8%). Dysmenorrhea, headache, acne, nausea, edema and increased appetite improved significantly in the continuous-use group, and mastalgia and edema in the cyclic-use group (p<.05). Six subjects in the continuous-use group (15.4%) and three in the cyclic-use group (7.7%) discontinued due to adverse events. Conclusions: Continuous use was associated with amenorrhea and fewer menstrual-related symptoms compared to cyclic use. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The objective of this study was to evaluate the effects of a contraceptive pill containing ethinylestradiol (30 mcg) and drospirenone (3 mg) in a continuous regimen on lipid, carbohydrate and coagulation parameters. Study Design: This open, prospective, randomized study included 78 participants (mean age 27.8 years) who were randomized into two groups to use the pill continuously for 168 days or for six 28-day cycles with a 7-day hormone-free interval between cycles. Markers of lipid, carbohydrate and coagulation profiles were measured prior to initiation and after the 6 months of pill use. Results: No statistically significant differences were found between the two contraceptive regimens with respect to carbohydrate or lipid profiles or in the parameters related to coagulation. Conclusions: The contraceptive combination of ethinylestradiol and drospirenone used in a continuous regimen was associated with metabolic alterations similar to those found during the traditional cyclic regimen of oral contraceptive use. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Obesity and obstructive sleep apnea (OSA) are both associated with the prevalence of major cardiovascular illnesses and certain common factors they are considered responsible for, such as stress oxidative increase, sympathetic tonus and resistance to insulin. Objective: The aim of the present study was to compare the effect of continuous positive airway pressure (CPAP) on oxidative stress and adiponectin levels in obese patients with and without OSA. Methods: Twenty-nine obese patients were categorized into 3 groups: group 1: 10 individuals without OSA (apnea-hypopnea index, AHI <= 5) who did not have OSA diagnosed at polysomnography; group 2: 10 patients with moderate to severe OSA (AHI >= 20) who did not use CPAP; group 3: 9 patients with moderate to severe OSA (AHI >= 20) who used CPAP. Results: Group 3 showed significant differences before and after the use of CPAP, in the variables of diminished production of superoxide, and increased nitrite and nitrate synthesis and adiponectin levels. Positive correlations were seen between the AHI and the superoxide production, between the nitrite and nitrate levels and the adiponectin levels, between superoxide production and the HOMA-IR, and between AHI and the HOMA-IR. Negative correlations were found between AHI and the nitrite and nitrate levels, between the superoxide production and that of nitric oxide, between the superoxide production and the adiponectin levels, between AHI and the adiponectin levels, and between the nitrite and nitrate levels and the HOMA-IR. Conclusions: This study demonstrates that the use of CPAP can reverse the increased superoxide production, the diminished serum nitrite, nitrate and plasma adiponectin levels, and the metabolic changes existing in obese patients with OSA. Copyright (C) 2009 S. Karger AG, Basel

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To describe current practice for the discontinuation of continuous renal replacement therapy in a multinational setting and to identify variables associated with successful discontinuation. The approach to discontinue continuous renal replacement therapy may affect patient outcomes. However, there is lack of information on how and under what conditions continuous renal replacement therapy is discontinued. Design: Post hoc analysis of a prospective observational study. Setting. Fifty-four intensive care units in 23 countries. Patients: Five hundred twenty-nine patients (52.6%) who survived initial therapy among 1006 patients treated with continuous renal replacement therapy. Interventions: None. Measurements and Main Results., Three hundred thirteen patients were removed successfully from continuous renal replacement therapy and did not require any renal replacement therapy for at least 7 days and were classified as the ""success"" group and the rest (216 patients) were classified as the ""repeat-RRT"" (renal replacement therapy) group. Patients in the ""success"" group had lower hospital mortality (28.5% vs. 42.7%, p < .0001) compared with patients in the ""repeat-RRT"" group. They also had lower creatinine and urea concentrations and a higher urine output at the time of stopping continuous renal replacement therapy. Multivariate logistic regression analysis for successful discontinuation of continuous renal replacement therapy identified urine output (during the 24 hrs before stopping continuous renal replacement therapy: odds ratio, 1.078 per 100 mL/day increase) and creatinine (odds ratio, 0.996 per mu mol/L increase) as significant predictors of successful cessation. The area under the receiver operating characteristic curve to predict successful discontinuation of continuous renal replacement therapy was 0.808 for urine output and 0.635 for creatinine. The predictive ability of urine output was negatively affected by the use of diuretics (area under the receiver operating characteristic curve, 0.671 with diuretics and 0.845 without diuretics). Conclusions. We report on the current practice of discontinuing continuous renal replacement therapy in a multinational setting. Urine output at the time of initial cessation (if continuous renal replacement therapy was the most important predictor of successful discontinuation, especially if occurring without the administration of diuretics. (Crit Care Med 2009; 37:2576-2582)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose of review To perform an update review on thyroglobulin gene mutations associated with congenital hypothyroidism, thyroid cancer, and autoimmunity. Recent findings Forty-two thyroglobulin mutations have been identified in dyshormonogenetic congenital hypothyroidism. Clinical and laboratory criteria defining defective thyroglobulin synthesis are mostly related to thyroglobulin mutations, generally caused by intracellular thyroglobulin transport defects to the colloid rather than defects in thyroid hormones synthesis. Some mutated thyroglobulin may escape the rigorous chaperone control and reach the colloid, allowing a wide phenotypic spectrum that includes euthyroidism in an adequate iodine environment. In some patients, continuous levothyroxine treatment does not reduce elevated serum thyroid-stimulating hormone (TSH) levels that may lead to goiter development. Prenatally, inactive mutant thyroglobulin will not be able to synthesize thyroid hormones and may increase pituitary thyrotroph threshold for thyroid hormone feedback. Congenital goiter is a risk factor for thyroid cancer and some thyroglobulin variants may confer susceptibility to thyroid autoimmunity. Summary Advances in the understanding of thyroglobulin genetic defects and its severity should allow researchers to perform adequate molecular diagnosis, genetic counseling, and intrauterine treatment to prevent subtle deficits in central nervous system development. This knowledge should improve the understanding of physiological functions of the thyroid and influence of nutritional iodine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exercise is an effective intervention for treating hypertension and arterial stiffness, but little is known about which exercise modality is the most effective in reducing arterial stiffness and blood pressure in hypertensive subjects. Our purpose was to evaluate the effect of continuous vs. interval exercise training on arterial stiffness and blood pressure in hypertensive patients. Sixty-five patients with hypertension were randomized to 16 weeks of continuous exercise training (n=26), interval training (n=26) or a sedentary routine (n=13). The training was conducted in two 40-min sessions a week. Assessment of arterial stiffness by carotid-femoral pulse wave velocity (PWV) measurement and 24-h ambulatory blood pressure monitoring (ABPM) were performed before and after the 16 weeks of training. At the end of the study, ABPM blood pressure had declined significantly only in the subjects with higher basal values and was independent of training modality. PWV had declined significantly only after interval training from 9.44 +/- 0.91 to 8.90 +/- 0.96 m s(-1), P=0.009 (continuous from 10.15 +/- 1.66 to 9.98 +/- 1.81 m s(-1), P-ns; control from 10.23 +/- 1.82 to 10.53 +/- 1.97 m s(-1), P-ns). Continuous and interval exercise training were beneficial for blood pressure control, but only interval training reduced arterial stiffness in treated hypertensive subjects. Hypertension Research (2010) 33, 627-632; doi:10.1038/hr.2010.42; published online 9 April 2010

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Despite antihypertensive therapy, it is difficult to maintain optimal systemic blood pressure (BP) values in hypertensive patients (HPT). Exercise may reduce BP in untreated HPT. However, evidence regarding its effect in long-term antihypertensive therapy is lacking. Our purpose was to evaluate the acute effects of 40-minute continuous (CE) or interval exercise (IE) using cycle ergometers on BP in long-term treated HPT. Methods: Fifty-two treated HPT were randomized to CE (n=26) or IE (n=26) protocols. CE was performed at 60% of reserve heart rate (HR). IE alternated consecutively 2 min at 50% reserve HR with 1 min at 80%. Two 24-h ambulatory BP monitoring were made after exercise (postexercise) or a nonexercise control period (control) in random order. Results: CE reduced mean 24-h systolic (S) BP (2.6 +/- 6.6 mm Hg, p-0.05) and diastolic (D) BP (2.3 +/- 4.6, p-0.01), and nighttime SBP (4.8 +/- 6.4, p < 0.001) and DBP (4.6 +/- 5.2 mm Hg, p-0.001). IE reduced 24-h SBP (2.8 +/- 6.5, p-0.03) and nighttime SBP (3.4 +/- 7.2, p-0.02), and tended to reduce nighttime DBP (p=0.06). Greater reductions occurred in higher BP levels. Percentage of normal ambulatory BP values increased after CE (24-h: 42% to 54%; daytime: 42% to 61%; nighttime: 61% to 69%) and IE (24-h: 31% to 46%; daytime: 54% to 61%; nighttime: 46% to 69%). Conclusion: CE and IE reduced ambulatory BP in treated HPT, increasing the number of patients reaching normal ambulatory BP values. These effects suggest that continuous and interval aerobic exercise may have a role in BP management in treated HPT. (c) 2008 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and objective: Hyperinflation with a decrease in inspiratory capacity (IC) is a common presentation for both unstable and stable COPD patients. As CPAP can reduce inspiratory load, possibly secondary to a reduction in hyperinflation, this study examined whether CPAP would increase IC in stable COPD patients. Methods: Twenty-one stable COPD patients (nine emphysema, 12 chronic bronchitis) received a trial of CPAP for 5 min at 4, 7 and 11 cmH(2)O. Fast and slow VC (SVC) were measured before and after each CPAP trial. In patients in whom all three CPAP levels resulted in a decreased IC, an additional trial of CPAP at 2 cmH(2)O was conducted. For each patient, a `best CPAP` level was defined as the one associated with the greatest IC. This pressure was then applied for an additional 10 min followed by spirometry. Results: Following application of the `best CPAP`, the IC and SVC increased in 15 patients (nine emphysema, six chronic bronchitis). The mean change in IC was 159 mL (95% CI: 80-237 mL) and the mean change in SVC was 240 mL (95% CI: 97-386 mL). Among these patients, those with emphysema demonstrated a mean increase in IC of 216 mL (95% CI: 94-337 mL). Six patients (all with chronic bronchitis) did not demonstrate any improvement in IC. Conclusions: The best individualized CPAP can increase inspiratory capacity in patients with stable COPD, especially in those with emphysema.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Simultaneous acquisition of electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) aims to disentangle the description of brain processes by exploiting the advantages of each technique. Most studies in this field focus on exploring the relationships between fMRI signals and the power spectrum at some specific frequency bands (alpha, beta, etc.). On the other hand, brain mapping of EEG signals (e.g., interictal spikes in epileptic patients) usually assumes an haemodynamic response function for a parametric analysis applying the GLM, as a rough approximation. The integration of the information provided by the high spatial resolution of MR images and the high temporal resolution of EEG may be improved by referencing them by transfer functions, which allows the identification of neural driven areas without strong assumptions about haemodynamic response shapes or brain haemodynamic`s homogeneity. The difference on sampling rate is the first obstacle for a full integration of EEG and fMRI information. Moreover, a parametric specification of a function representing the commonalities of both signals is not established. In this study, we introduce a new data-driven method for estimating the transfer function from EEG signal to fMRI signal at EEG sampling rate. This approach avoids EEG subsampling to fMRI time resolution and naturally provides a test for EEG predictive power over BOLD signal fluctuations, in a well-established statistical framework. We illustrate this concept in resting state (eyes closed) and visual simultaneous fMRI-EEG experiments. The results point out that it is possible to predict the BOLD fluctuations in occipital cortex by using EEG measurements. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: This study evaluated the impact of 2 models of educational intervention on rates of central venous catheter-associated bloodstream infections (CVC-BSIs). Methods: This was a prospective observational study conducted between January 2005 and June 2007 in 2 medical intensive care units (designated ICU A and ICU B) in a large teaching hospital. The study was divided into in 3 periods: baseline (only rates were evaluated), preintervention (questionnaire to evaluate knowledge of health care workers [HCWs] and observation of CVC care in both ICUs), and intervention (in ICU A, tailored, continuous intervention; in ICU B, a single lecture). The preintervention and intervention periods for each ICU were compared. Results: During the preintervention period, 940 CVC-days were evaluated in ICUA and 843 CVC-days were evaluated in ICU B. During the intervention period, 2175 CVC-days were evaluated in ICUA and 1694 CVC-days were evaluated in ICU B. Questions regarding CVC insertion, disinfection during catheter manipulation, and use of an alcohol-based product during dressing application were answered correctly by 70%-100% HCWs. Nevertheless, HCWs` adherence to these practices in the preintervention period was low for CVC handling and dressing, hand hygiene (6%-35%), and catheter hub disinfection (45%-68%). During the intervention period, HCWs` adherence to hand hygiene was 48%-98%, and adherence to hub disinfection was 82%-97%. CVC-BSI rates declined in both units. In ICUA, this decrease was progressive and sustained, from 12CVC-BSIs/1000 CVC-days at baseline to 0 after 9 months. In ICU B, the rate initially dropped from 16.2 to 0 CVC-BSIs/1000 CVC-days, but then increased to 13.7 CVC-BSIs/1000 CVC-days. Conclusion: Personal customized, continuous intervention seems to develop a ""culture of prevention"" and is more effective than single intervention, leading to a sustained reduction of infection rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Obstructive sleep apnea and hypertension are common conditions that frequently coexist. Continuous positive airway pressure (CPAP) reduces blood pressure in patients with obstructive sleep apnea and sustained hypertension. However, the impact of CPAP on patients with obstructive sleep apnea and prehypertension and masked hypertension, conditions associated with increased cardiovascular risk, is unknown. Thirty-six male patients (age, 43 +/- 7 years; body mass index, 28.8 +/- 3.0 kg/m(2)) with untreated severe obstructive sleep apnea (apnea-hypopnea index, 56 +/- 22 events/hr on polysomnography) with diagnostic criteria for prehypertension and/or masked hypertension, based on office and 24-hour ambulatory blood pressure monitoring, respectively, were studied. The patients randomized to no treatment (control; n=18) or CPAP (n=18) for 3 months had similar frequency of prehypertension and masked hypertension at study entry. There were no significant changes in blood pressure in patients randomized to the control group. In contrast, patients randomized to CPAP presented significant reduction in office systolic (from 126 +/- 5 to 121 +/- 7 mm Hg; P=0.001) and a trend for diastolic blood pressure (from 75 +/- 7 to 73 +/- 8 mm Hg; P=0.08) as well as a significant decrease in daytime and nighttime systolic and diastolic blood pressure (P < 0.05 for each comparison). There was a significant reduction in the frequency of prehypertension (from 94% to 55%; P=0.02) and masked hypertension (from 39% to 5%; P=0.04) only in the CPAP group. In conclusion, effective CPAP therapy promotes significant reduction in the frequency of prehypertension and masked hypertension by promoting significant blood pressure reductions in patients with severe obstructive sleep apnea. (Hypertension. 2011;57[part 2]:549-555.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Obstructive sleep apnoea-hypopnoea syndrome (OSAHS) is a respiratory disorder with high morbidity and mortality. Continuous positive airway pressure (CPAP) is the most commonly prescribed conservative treatment for adults with OSAHS. CPAP therapy normalises or decreases OSAHS symptoms and can reduce and prevent OSAHS complications. Aims: To evaluate adherence to nasal CPAP treatment and CPAP impact on daytime drowsiness. Method: A sample of 20 patients evaluated for daytime drowsiness using the Epworth sleepiness scale and interviewed for adherence to nasal CPAP use. Results: There was a significant decrease in the level of daytime sleepiness of the patients users of nasal CPAP (p=0.017); patients not using nasal CPAP experienced a decrease without statistical significance (p=0.162). 100% of CPAP users reported benefits and 50% of these reported related discomforts. Conclusions: Patients with OSAHS that use CPAP have a greater reduced level of sleepiness than those who do not use it.