72 resultados para Standard reference
Resumo:
OBJECTIVE. Coronary MDCT angiography has been shown to be an accurate noninvasive tool for the diagnosis of obstructive coronary artery disease (CAD). Its sensitivity and negative predictive value for diagnosing percentage of stenosis are unsurpassed compared with those of other noninvasive testing methods. However, in its current form, it provides no information regarding the physiologic impact of CAD and is a poor predictor of myocardial ischemia. CORE320 is a multicenter multinational diagnostic study with the primary objective to evaluate the diagnostic accuracy of 320-MDCT for detecting coronary artery luminal stenosis and corresponding myocardial perfusion deficits in patients with suspected CAD compared with the reference standard of conventional coronary angiography and SPECT myocardial perfusion imaging. CONCLUSION. We aim to describe the CT acquisition, reconstruction, and analysis methods of the CORE320 study.
Resumo:
Background: The high missed occult small bowel injuries (SBI) associated with laparoscopy in trauma (LIT) is a major reason why some surgeons still preclude LIT today. No standardized laparoscopic examination for evaluation of the peritoneal cavity is described for trauma. The objective of this article is to verify if a systematic standardized laparoscopic approach could correctly identify SBI in the peritoneal cavity for penetrating abdominal trauma (PAT). Methods: Victims with PAT were evaluated in a prospective, nonrandomized study. A total of 75 hemodynamically stable patients with suspected abdominal injuries were operated by LIT and converted to laparotomy if criteria were met: SBI and lesions to blind spot zones-retroperitoneal hematoma, injuries to segments VI or VII of the liver, or injuries to the posterior area of the spleen. Inclusion criteria were equivocal evidence of abdominal injuries or peritonea] penetration; systolic blood pressure >90 mm Hg and <3 L of IV fluids in the first hour of admission; Glasgow Coma Scale score >12; and age >12 years. Exclusion criteria were back injuries; pregnancy; previous laparotomy; and chronic cardiorespiratory disease. Results: Sixty patients were males and there were 38 stab wounds and 37 gunshot wounds. No SBI was missed, but a pancreatic lesion was undiagnosed due to a retroperitoneal hematoma. Twenty patients (26.6%) were converted. Unnecessary laparotomies were avoided in 73.33%. Therapeutic LIT was possible in 22.7%. Accuracy was 98.66% with 97.61% sensitivity and 100% specificity. Conclusions: Standard systematic laparoscopic exploration was 100% effective to detect SBI in the peritoneal cavity. Conversion from LIT to laparotomy should be done if injuries to blind spot zones are found which are poorly evaluated by LIT. Therapeutic LIT is feasible in PAT.
Resumo:
To determine reference values for tissue Doppler imaging (TDI) and pulsed Doppler echocardiography for left ventricular diastolic function analysis in a healthy Brazilian adult population. Observations were based on a randomly selected healthy population from the city of Vitoria, Espirito Santo, Brazil. Healthy volunteers (n = 275, 61.7% women) without prior histories of cardiovascular disease underwent transthoracic echocardiography. We analyzed 175 individuals by TDI and evaluated mitral annulus E`- and A`-waves from the septum (S) and lateral wall (L) to calculate E`/A` ratios. Using pulsed Doppler echocardiography, we further analyzed the mitral E- and A-waves, E/A ratios, isovolumetric relaxation times (IRTs), and deceleration times (DTs) of 275 individuals. Pulsed Doppler mitral inflow mean values for men were as follows: E-wave: 71 +/- 16 cm/sec, A-wave: 68 +/- 15 cm/sec, IRT: 74.8 +/- 9.2 ms, DT: 206 +/- 32.3 ms, E/A ratio: 1.1 +/- 0.3. Pulsed Doppler mitral inflow mean values for women were as follows: E-wave: 76 +/- 17, A-wave: 69 +/- 14 cm/sec, IRT: 71.2 +/- 10.5 ms, DT: 197 +/- 33.3 ms, E/A ratio: 1.1 +/- 0.3. IRT and DT values were higher in men than in women (P = 0.04 and P = 0.007, respectively). TDI values in men were as follows: E`S: 11 +/- 3 cm/sec, A`S: 13 +/- 2 cm/sec, E`S/A`S: 0.89 +/- 0.2, E`L: 14 +/- 3 cm/sec, A`L: 14 +/- 2 cm/sec, E`L/A`L: 1.1 +/- 0.4. E-wave/ E`S ratio: 6.9 +/- 2.2; E-wave / E`L ratio: 4.9 +/- 1.7. In this study, we determined pulsed Doppler and TDI derived parameters for left ventricular diastolic function in a large sample of healthy Brazilian adults. (Echocardiography 2010;27:777-782).
Resumo:
Left ventricular hypertrophy is an important predictor of cardiovascular risk and sudden death. This study explored the ability of four obesity indexes (body mass index, waist circumference, waist-hip ratio and waist-stature ratio) to identify left ventricular hypertrophy. A sample of the general population (n=682; 43.5% men) was surveyed to assess cardiovascular risk factors. Biochemical, anthropometric and blood pressure values were obtained in a clinic visit according to standard methods. Left ventricular mass was obtained from transthoracic echocardiogram. Left ventricular hypertrophy was defined using population-specific cutoff values for left ventricular mass indexed to height(2.7). The waist-stature ratio showed the strongest positive association with left ventricular mass. This correlation was stronger in women, even after controlling for age and systolic blood pressure. By multivariate analysis, the main predictors of left ventricular hypertrophy were waist-stature ratio (23%), systolic blood pressure (9%) and age (2%) in men, and waist-stature ratio (40%), age (6%) and systolic blood pressure (2%) in women. Receiver-operating characteristic curves showed the optimal cutoff values of the different anthropometric indexes associated with left ventricular hypertrophy. The waist-stature ratio was a significantly better predictor than the other indexes (except for the waist-hip ratio), independent of gender. It is noteworthy that a waist-stature ratio cutoff of 0.56 showed the highest combined sensitivity and specificity to detect left ventricular hypertrophy. Abdominal obesity identified by waist-stature ratio instead of overall obesity identified by body mass index is the simplest and best obesity index for assessing the risk of left ventricular hypertrophy, is a better predictor in women and has an optimal cutoff ratio of 0.56. Hypertension Research (2010) 33, 83-87; doi: 10.1038/hr.2009.188; published online 13 November 2009
Resumo:
Background: In Brazil hospital malnutrition is highly prevalent. physician awareness of malnutrition is low, and nutrition therapy is underprescribed. One alternative to approach this problem is to educate health care providers in clinical nutrition. The present study aims to evaluate the effect of an intensive education course given to health care professionals and students on the diagnosis ability concerning to hospital malnutrition. Materials and methods: An intervention study based on a clinical nutrition educational program, offered to medical and nursing students and professionals, was held in a hospital of the Amazon region. Participants were evaluated through improvement of diagnostic ability, according to agreement of malnutrition diagnosis using Subjective Global Assessment before and after the workshop, as compared to independent evaluations (Kappa Index, k). To evaluate the impact of the educational intervention on the hospital malnutrition diagnosis, medical records were reviewed for documentation of parameters associated with nutritional status of in-patients. The SPSS statistical software package was used for data analysis. Results: A total of 165 participants concluded the program. The majority (76.4%) were medical and nursing students. Malnutrition diagnosis improved after the course (before k = 0.5; after k = 0.64; p < 0.05). A reduction of false negatives from 50% to 33.3% was observed. During the course, concern of nutritional diagnosis was increased W = 17.57; p < 0.001) and even after the course, improvement on the height measurement was detected chi(2) 12.87;p < 0.001). Conclusions: Clinical nutrition education improved the ability of diagnosing malnutrition; however the primary impact was on medical and nursing students. To sustain diagnostic capacity a clinical nutrition program should be part of health professional curricula and be coupled with continuing education for health care providers.
Resumo:
The treatment of sensorineural hearing loss is based on hearing aids, also known as individual sound amplification devices. The hearing aids purchased by the Brazilian Government, aiming at fulfilling public policies, are based on dedicated components, which bring about benefits, but also render them expensive and may impair repair services after manufacture`s warranty expires. Aim: to design digital behind-the-ear hearing aids built from standardized components coming from the very supply chain of these manufacturers. Study design: experimental. Materials and Methods: to identify the supply chain of these manufacturers, request samples and set up hearing aids in the laboratory. Results: The developed hearing aids did not show lesser electroacoustic characteristics when compared to those acquired by the Government, also being tested by the same reference international technical standard. Conclusion: It is possible to develop digital behind-the-ear hearing aids based on off-the-shelf components from hearing aid manufacturers` supply chain. Their advantages include low operational costs - for acquisition (with clear advantages for the Government) and service (advantage for the patient).
Concepts and determination of reference values for human biomonitoring of environmental contaminants
Resumo:
Human biomonitoring (HBM) of environmental contaminants plays an important role in estimating exposure and evaluating risk, and thus it has been increasingly applied in the environmental field. The results of HBM must be compared with reference values ( RV). The term ""reference values"" has always been related to the interpretation of clinical laboratory tests. For physicians, RV indicate ""normal values"" or ""limits of normal""; in turn, toxicologists prefer the terms ""background values"" or ""baseline values"" to refer to the presence of contaminants in biological fluids. This discrepancy leads to the discussion concerning which should be the population selected to determine RV. Whereas clinical chemistry employs an altered health state as the main exclusion criterion to select a reference population ( that is, a ""healthy"" population would be selected), in environmental toxicology the exclusion criterion is the abnormal exposure to xenobiotics. Therefore, the choice of population to determine RV is based on the very purpose of the RV to be determined. The present paper discusses the concepts and methodology used to determine RV for biomarkers of chemical environmental contaminants.
Resumo:
This was a longitudinal study carried out during a period over 2 years with a cohort of 946 individuals of both sexes, aged 1 year and older, from an endemic area of American visceral leishmaniasis (AVL) in Para State, Brazil. The object was to analyze the transmission dynamics of human Leishmania (Leishmania) infantum chagasi infection based principally on the prevalence and incidence. For diagnosis of the infection, the indirect fluorescent antibody test (IFAT) and leishmanin skin test (LST) were performed with amastigote and promastigote antigens of the parasite, respectively. The prevalence by LST (11.2%) was higher (p < 0.0001) than that (3.4%) by IFAT, and the combined prevalence by both tests was 12.6%. The incidences by LST were also higher (p < 0.05) than those by IFAT at 6 (4.7% A- 0.6%), 12 (4.7% A- 2.7%), and 24 months (2.9% A- 0.3%). Moreover, there were no differences (p > 0.05) between the combined incidences by both tests on the same point surveys, 5.2%, 6.3%, and 3.6%. During the study, 12 infected persons showed high IFAT IgG titers with no LST reactions: five children and two adults developed AVL (2,560-10,120), and two children and three adults developed subclinical oligosymptomatic infection (1,280-2,560). The combined tests diagnosed a total of 231 cases of infection leading to an accumulated prevalence of 24.4%.
Resumo:
Breast cancer accounts for approximately one quarter of all cancers in females. HER2 gene amplification or HER2 protein overexpression, detected in about 20% of breast carcinomas, predicts a more aggressive clinical course and determines eligibility for targeted therapy with trastuzumab. HER2 testing has become an essential part of the clinical evaluation of all breast carcinoma patients, and accurate HER2 results are critical in identifying patients who may be benefited from targeted therapy. This study investigated the concordance in the results of HER2 immunohistochemistry assays performed in 500 invasive breast carcinomas between a reference laboratory and 149 local laboratories from all geographic regions of Brazil. Our results showed an overall poor concordance (171 of 500 cases, 34.2%) regarding HER2 results between local and reference laboratories, which may be related to the low-volume load of HER2 assays, inexperience with HER2 scoring system, and/or technical issues related to immunohistochemistry in local laboratories. Standardization of HER2 testing with rigorous quality control measures by local laboratories is highly recommended to avoid erroneous treatment of breast cancer patients.
Resumo:
Despite the growing evidence of poor psychosocial adjustment, at present there is no formal method of assessment of social adjustment in patients with temporal lobe epilepsy (TLE). First, we assessed social adjustment in patients with TLE using a self-report questionnaire and compared the results with those from quality-of-life (QOL) scales. Second, we verified the influence of cognitive performance and clinical variables of epilepsy on social adjustment and QOL We evaluated 35 people with TLE and 38 healthy controls. Patients had worse social adjustment, and it was correlated with worse perception of cognitive function. Attention and verbal memory dysfunctions were negatively correlated with social adjustment. However, there was no significant correlation between cognitive performance and QOL Regarding clinical variables, persons with left TLE showed worse social adjustment and patients with frequent seizures showed worse QOL These findings indicate the relevance of evaluating social adjustment and emphasize the importance of cognitive rehabilitation to improved social adjustment. (c) 2010 Elsevier Inc. All rights reserved.
Resumo:
Objective: To investigate clinical and MRI findings that are predictive of both visual loss in patients with pituitary adenomas and visual recovery after treatment. Design: Cohort study. Participants: Thirty patients (60 eyes) with pituitary adenoma. Methods: Patients underwent neuro-ophthalmic examination and MRI before and after optic chiasm decompression. Visual field (VF) was assessed using the mean deviation in standard automated perimetry (SAP) and temporal mean defect, the average of 22 temporal values of the total deviation plot. Tumour size was measured on sagittal and coronal cuts. Results: Visual loss was found in 47 eyes; 35 had optic atrophy (subtle in 9, moderate in 14, and severe in 12). Before treatment, the average SAP mean deviation and temporal mean defect were -11.78 (SD 8.56) dB and -18.66 (SD 11.20) dB, respectively. The chiasm was 17.3 (SD 6.2, range 10-34) mm above the reference line on the sagittal and 21.8 (SD 8.3, range 12-39) mm on the coronal images. Tumour size correlated with the severity of VF defect. VF improvement occurred in 80% of eyes after treatment. The degree of optic atrophy, visual loss, and tumour size were significantly associated with improvement after treatment. Conclusions: The best predictive factor for visual loss was tumour size, and factors related to visual recovery were the degree of optic atrophy, the severity of VF defect, and the tumour size. Diagnosing pituitary adenomas before optic atrophy becomes severe may be related to a better prognosis in such patients.
Resumo:
Objective To determine normal blood flow velocities across the fetal tricuspid valve (TV) at 11-13 weeks and 6 days of gestation and to examine the reproducibility of these measurements. Methods A prospective study involving 166 normal singleton pregnancies examined at 11-13 weeks and 6 days was carried out. Descriptive analysis of E- and A-waves` maximum velocities, E/A ratio, duration of the cardiac cycle (C) and diastole (D) and D/C ratio were calculated. Intraobserver and interobserver agreement analysis was performed in a subgroup of 12 cases. Results Average (+/- SD) flow velocities were: E-wave, 25.0 (+/- 4.6) cm/s; A-wave. 42.9 (+/- 5.9) cm/s; E/A, 0.58 (+/- 0.07); cardiac cycle, 390 (+/- 21.1) ms; diastole, 147 (+/- 18) ms and D/C, 0.38 (+/- 0.04). Significant correlation was observed between all parameters (except A-wave) and gestational age but not with nuchal translucency (NT). Intraclass correlation coefficients (interobserver, intraobsever examiner I and intraobserver examiner 2) were: E-wave, 0.53, 0.53 and 0.64; A-wave, 0.45, 0.46 and 0.49; cardiac cycle, 0.70, 0.79 and 0.84 and diastole, 0.63, 0.85 and 0.82, respectively. Conclusions The present study establishes normal Doppler parameters for blood flow across the TV at 11 - 13 weeks and 6 days and demonstrates that these parameters do not correlate with NT measurement and have good/moderate reproducibility. Copyright (C) 2010 John Wiley & Sons, Ltd.
Resumo:
Introduction: Two hundred ten patients with newly diagnosed Hodgkin`s lymphoma (HL) were consecutively enrolled in this prospective trial to evaluate the cost-effectiveness of fluorine-18 ((18)F)-fluoro-2-deoxy-D-glucose-positron emission tomography (FDG-PET) scan in initial staging of patients with HL. Methods: All 210 patients were staged with conventional clinical staging (CCS) methods, including computed tomography (CT), bone marrow biopsy (BMB), and laboratory tests. Patients were also submitted to metabolic staging (MS) with whole-body FDG-PET scan before the beginning of treatment. A standard of reference for staging was determined with all staging procedures, histologic examination, and follow-up examinations. The accuracy of the CCS was compared with the MS. Local unit costs of procedures and tests were evaluated. Incremental cost-effectiveness ratio (ICER) was calculated for both strategies. Results: In the 210 patients with HL, the sensitivity for initial staging of FDG-PET was higher than that of CT and BMB in initial staging (97.9% vs. 87.3%; P < .001 and 94.2% vs. 71.4%, P < 0.003, respectively). The incorporation of FDG-PET in the staging procedure upstaged disease in 50 (24%) patients and downstaged disease in 17 (8%) patients. Changes in treatment would be seen in 32 (15%) patients. Cumulative cost for staging procedures was $3751/patient for CCS compared to $5081 for CCS + PET and $4588 for PET/CT. The ICER of PET/CT strategy was $16,215 per patient with modified treatment. PET/CT costs at the beginning and end of treatment would increase total costs of HL staging and first-line treatment by only 2%. Conclusion: FDG-PET is more accurate than CT and BMB in HL staging. Given observed probabilities, FDG-PET is highly cost-effective in the public health care program in Brazil.
Resumo:
Purpose: To evaluate the ability of the GDx Variable Corneal Compensation (VCC) Guided Progression Analysis (GPA) software for detecting glaucomatous progression. Design: Observational cohort study. Participants: The study included 453 eyes from 252 individuals followed for an average of 46 +/- 14 months as part of the Diagnostic Innovations in Glaucoma Study. At baseline, 29% of the eyes were classified as glaucomatous, 67% of the eyes were classified as suspects, and 5% of the eyes were classified as healthy. Methods: Images were obtained annually with the GDx VCC and analyzed for progression using the Fast Mode of the GDx GPA software. Progression using conventional methods was determined by the GPA software for standard automated achromatic perimetry (SAP) and by masked assessment of optic disc stereophotographs by expert graders. Main Outcome Measures: Sensitivity, specificity, and likelihood ratios (LRs) for detection of glaucoma progression using the GDx GPA were calculated with SAP and optic disc stereophotographs used as reference standards. Agreement among the different methods was reported using the AC(1) coefficient. Results: Thirty-four of the 431 glaucoma and glaucoma suspect eyes (8%) showed progression by SAP or optic disc stereophotographs. The GDx GPA detected 17 of these eyes for a sensitivity of 50%. Fourteen eyes showed progression only by the GDx GPA with a specificity of 96%. Positive and negative LRs were 12.5 and 0.5, respectively. None of the healthy eyes showed progression by the GDx GPA, with a specificity of 100% in this group. Inter-method agreement (AC1 coefficient and 95% confidence intervals) for non-progressing and progressing eyes was 0.96 (0.94-0.97) and 0.44 (0.28-0.61), respectively. Conclusions: The GDx GPA detected glaucoma progression in a significant number of cases showing progression by conventional methods, with high specificity and high positive LRs. Estimates of the accuracy for detecting progression suggest that the GDx GPA could be used to complement clinical evaluation in the detection of longitudinal change in glaucoma. Financial Disclosure(s): Proprietary or commercial disclosure may be found after the references. Ophthalmology 2010; 117: 462-470 (C) 2010 by the American Academy of Ophthalmology.
Resumo:
Purpose: The aim of this study was to investigate the impact of acute PaCO(2) temporal variation on the standard base excess (SBE) value in critically ill patients. Methods: A total of 265 patients were prospectively observed; 158 were allocated to the modeling group, and 107 were allocated to the validation group. Two models were developed in the modeling group (one including and one excluding PaCO(2) as a variable determinant of SBE), and both were tested in the validation group. Results: In the modeling group, the mathematical model including SIDai, SIG, L-lactate, albumin, phosphate, and PaCO(2) had a predictive superiority in comparison with the model without PaCO(2) (R(2) = 0.978 and 0.916, respectively). In the validation group, the results were confirmed with significant F change statistics (R(2) change = 0.059, P < .001) between the model with and without PaCO(2). A high correlation (R = 0.99, P < .001) and agreement (bias = -0.25 mEq/L, limits of agreement 95% = -0.72 to 0.22 mEq/L) were found between the model-predicted SBE value and the SBE calculated using the Van Slyke equation. Conclusions: Acute PaCO(2), temporal variation is related to SBE changes in critically ill patients. (C) 2009 Elsevier Inc. All rights reserved.