58 resultados para Quantities and measurements
Resumo:
BACKGROUND CONTEXT: The vertebral spine angle in the frontal plane is an important parameter in the assessment of scoliosis and may be obtained from panoramic X-ray images. Technological advances have allowed for an increased use of digital X-ray images in clinical practice. PURPOSE: In this context, the objective of this study is to assess the reliability of computer-assisted Cobb angle measurements taken from digital X-ray images. STUDY DESIGN/SETTING: Clinical investigation quantifying scoliotic deformity with Cobb method to evaluate the intra- and interobserver variability using manual and digital techniques. PATIENT SAMPLE: Forty-nine patients diagnosed with idiopathic scoliosis were chosen based on convenience, without predilection for gender, age, type, location, or magnitude of the curvature. OUTCOME MEASURES: Images were examined to evaluate Cobb angle variability, end plate selection, as well as intra- and interobserver errors. METHODS: Specific software was developed to digitally reproduce the Cobb method and calculate semiautomatically the degree of scoliotic deformity. During the study, three observers estimated the Cobb angle using both the digital and the traditional manual methods. RESULTS: The results showed that Cobb angle measurements may be reproduced in the computer as reliably as with the traditional manual method, in similar conditions to those found in clinical practice. CONCLUSIONS: The computer-assisted method (digital method) is clinically advantageous and appropriate to assess the scoliotic curvature in the frontal plane using Cobb method. (C) 2010 Elsevier Inc. All rights reserved.
Resumo:
Objective To investigate whether standardization of the multiplanar view (SMV) when evaluating the uterus using three-dimensional ultrasonography (3D-US) improves intra-and interobserver reliability and agreement with regard to endometrial measurement. Methods Two-dimensional (2D) and 3D-US was used to measure endometrial thickness by two observers in 30 women undergoing assisted reproduction treatment. Endometrial volume was measured with Virtual Organ Computer-aided AnaLysis (VOCAL (TM)) in the longitudinal (A) and coronal (C) planes using an unmodified multiplanar view (UMV) and a standardized multiplanar view (SMV). Measurement reliability was evaluated by intraclass correlation coefficient (ICC) and agreement was examined using Bland-Altman plots with limits of agreement (LoA). The ease of outlining the endometrial-myometrial interface was compared between the A-and C-planes using subjective assessment. Results Endometrial volume measurements using the SMV and A-plane were more reliable (intra-and interobserver ICCs, 0.979 and 0.975, respectively) than were measurements of endometrial thickness using 2D-US (intra-and interobserver ICCs, 0.742 and 0.702, respectively) or 3D-US (intra-and interobserver ICCs, 0.890 and 0.784, respectively). The LoAs were narrower for SMV than for UMV. Reliability and agreement were not much different between the A- and C-planes. However the observers agreed that delineating the endometrial-myometrial interface using the A-plane was easier (first and second observer, 50.0 and 46.7%, respectively) or `comparable` (50 and 53.3%, respectively), but never more difficult than using the C-plane. Conclusions Endometrial volume measurements are more reliable than endometrial thickness measurements and are best performed using SMV and the A-plane. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.
Resumo:
The objective was to evaluate the influence of dental metallic artefacts on implant sites using multislice and cone-beam computed tomography techniques. Ten dried human mandibles were scanned twice by each technique, with and without dental metallic artefacts. Metallic restorations were placed at the top of the alveolar ridge adjacent to the mental foramen region for the second scanning. Linear measurements (thickness and height) for each cross-section were performed by a single examiner using computer software. All mandibles were analysed at both the right and the left mental foramen regions. For the multislice technique, dental metallic artefact produced an increase of 5% in bone thickness and a reduction of 6% in bone height; no significant differences (p > 0.05) were detected when comparing measurements performed with and without metallic artefacts. With respect to the cone-beam technique, dental metallic artefact produced an increase of 6% in bone thickness and a reduction of 0.68% in bone height. No significant differences (p > 0.05) were observed when comparing measurements performed with and without metallic artefacts. The presence of dental metallic artefacts did not alter the linear measurements obtained with both techniques, although its presence made the location of the alveolar bone crest more difficult.
Resumo:
Objective. The purpose of this research was to provide further evidence to demonstrate the precision and accuracy of maxillofacial linear and angular measurements obtained by cone-beam computed tomography (CBCT) images. Study design. The study population consisted of 15 dry human skulls that were submitted to CBCT, and 3-dimensional (3D) images were generated. Linear and angular measurements based on conventional craniometric anatomical landmarks, and were identified in 3D-CBCT images by 2 radiologists twice each independently. Subsequently, physical measurements were made by a third examiner using a digital caliper and a digital goniometer. Results. The results demonstrated no statistically significant difference between inter-and intra-examiner analysis. Regarding accuracy test, no statistically significant differences were found of the comparison between the physical and CBCT-based linear and angular measurements for both examiners (P = .968 and .915, P = .844 and .700, respectively). Conclusions. 3D-CBCT images can be used to obtain dimensionally accurate linear and angular measurements from bony maxillofacial structures and landmarks. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: 430-436)
Resumo:
The objective of this study was to test a device developed to improve the functionality, accuracy and precision of the original technique for sweating rate measurements proposed by Schleger and Turner [Schleger AV, Turner HG (1965) Aust J Agric Res 16:92-106]. A device was built for this purpose and tested against the original Schleger and Turner technique. Testing was performed by measuring sweating rates in an experiment involving six Mertolenga heifers subjected to four different thermal levels in a climatic chamber. The device exhibited no functional problems and the results obtained with its use were more consistent than with the Schleger and Turner technique. There was no difference in the reproducibility of the two techniques (same accuracy), but measurements performed with the new device had lower repeatability, corresponding to lower variability and, consequently, to higher precision. When utilizing this device, there is no need for physical contact between the operator and the animal to maintain the filter paper discs in position. This has important advantages: the animals stay quieter, and several animals can be evaluated simultaneously. This is a major advantage because it allows more measurements to be taken in a given period of time, increasing the precision of the observations and diminishing the error associated with temporal hiatus (e.g., the solar angle during field studies). The new device has higher functional versatility when taking measurements in large-scale studies (many animals) under field conditions. The results obtained in this study suggest that the technique using the device presented here could represent an advantageous alternative to the original technique described by Schleger and Turner.
Resumo:
This study analyzes and discusses data taken from oceanic and atmospheric measurements performed simultaneously at the Brazil-Malvinas Confluence (BMC) region in the southwestern Atlantic Ocean. This area is one of the most dynamical frontal regions of the world ocean. Data were collected during four research cruises in the region once a year in consecutive years between 2004 and 2007. Very few studies have addressed the importance of studying the air-sea coupling at the BMC region. Lateral temperature gradients at the study region were as high as 0.3 degrees C km(-1) at the surface and subsurface. In the oceanic boundary layer, the vertical temperature gradient reached 0.08 degrees C m(-1) at 500 m depth. Our results show that the marine atmospheric boundary layer (MABL) at the BMC region is modulated by the strong sea surface temperature (SST) gradients present at the sea surface. The mean MABL structure is thicker over the warmside of the BMC where Brazil Current (BC) waters predominate. The opposite occurs over the coldside of the confluence where waters from the Malvinas (Falkland) Current (MC) are found. The warmside of the confluence presented systematically higher MABL top height compared to the coldside. This type of modulation at the synoptic scale is consistent to what happens in other frontal regions of the world ocean, where the MABL adjusts itself to modifications along the SST gradients. Over warm waters at the BMC region, the MABL static instability and turbulence were increased while winds at the lower portion of the MABL were strong. Over the coldside of the BC/MC front an opposite behavior is found: the MABL is thinner and more stable. Our results suggest that the sea-level pressure (SLP) was also modulated locally, together with static stability vertical mixing mechanism, by the surface condition during all cruises. SST gradients at the BMC region modulate the synoptic atmospheric pressure gradient. Postfrontal and prefrontal conditions produce opposite thermal advections in the MABL that lead to different pressure intensification patterns across the confluence.
Resumo:
The assembling of a system for field sampling and activity concentration measurement of radon dissolved in groundwater is described. Special attention is given in presenting the calibration procedure to obtain the radon activity concentration in groundwater from the raw counting rate registered in a portable scintillation detector and in establishing the precision of the activity concentration measurements. A field procedure was established and the system tested during one year of monthly observations of (222)Rn activity concentration in groundwater drawn from two wells drilled on metamorphic rocks exposed at Eastern Sao Paulo State, Brazil. The observed mean (222)Rn activity concentrations are 374 Bq/dm(3) in one well and about 1275 Bq/dm(3) in the other one. In both wells the (222)Rn activity concentrations showed a seasonal variation similar to variations previously reported in the literature for the same region. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
[1] Iron is hypothesized to be an important micronutrient for ocean biota, thus modulating carbon dioxide uptake by the ocean biological pump. Studies have assumed that atmospheric deposition of iron to the open ocean is predominantly from mineral aerosols. For the first time we model the source, transport, and deposition of iron from combustion sources. Iron is produced in small quantities during fossil fuel burning, incinerator use, and biomass burning. The sources of combustion iron are concentrated in the industrialized regions and biomass burning regions, largely in the tropics. Model results suggest that combustion iron can represent up to 50% of the total iron deposited, but over open ocean regions it is usually less than 5% of the total iron, with the highest values (< 30%) close to the East Asian continent in the North Pacific. For ocean biogeochemistry the bioavailability of the iron is important, and this is often estimated by the fraction which is soluble ( Fe(II)). Previous studies have argued that atmospheric processing of the relatively insoluble Fe(III) occurs to make it more soluble ( Fe( II)). Modeled estimates of soluble iron amounts based solely on atmospheric processing as simulated here cannot match the variability in daily averaged in situ concentration measurements in Korea, which is located close to both combustion and dust sources. The best match to the observations is that there are substantial direct emissions of soluble iron from combustion processes. If we assume observed soluble Fe/black carbon ratios in Korea are representative of the whole globe, we obtain the result that deposition of soluble iron from combustion contributes 20-100% of the soluble iron deposition over many ocean regions. This implies that more work should be done refining the emissions and deposition of combustion sources of soluble iron globally.
Resumo:
The quadrupolar hyperfine interactions of in-diffused (111)In -> (111)Cd probes in polycrystalline isostructural Zr(4)Al(3) and Hf(4)Al(3) samples containing small admixtures of the phases (Zr/Hf)(3)Al(2) were investigated. A strong preference of (111)In solutes for the contaminant (Zr/Hf)(3)Al(2) minority phases was observed. Detailed calculations of the electric field gradient (EFG) at the Cd nucleus using the full-potential augmented plane wave + local orbital formalism allowed us to assign the observed EFG fractions to the various lattice sites in the (Zr/Hf)(3)Al(2) compounds and to understand the preferential site occupation of the minority phases by the (111)In atoms. The effects of the size of the supercell and relaxation around the oversized In and Cd probe atoms were investigated in detail.
Resumo:
Polycrystalline La(0.86)Sr(0.14)Mn(1-x)Cu(x)O(3+delta) (x = 0, 0.05, 0.10, 0.15, 0.20) manganites were investigated by means of magnetic measurements and zero-field (139)La and (55)Mn nuclear magnetic resonance (NMR) spectroscopy. Magnetization versus temperature measurements revealed a paramagnetic to ferromagnetic transition in most samples, with lower Curie temperatures and broader transitions for samples with higher Cu contents. The details of the magnetization measurements suggested a phase-separated scenario, with ferromagnetic clusters embedded in an antiferromagnetic matrix, especially for the samples with large Cu contents (x = 0.15 and 0.20). Zero-field (139)La NMR measurements confirmed this finding, since the spectral features remained almost unchanged for all Cu-doped samples, whereas the bulk magnetization was drastically reduced with increasing Cu content. (55)Mn NMR spectra were again typical of ferromagnetic regions, with a broadening of the resonance line caused by the disorder introduced by the Cu doping. The results indicate a coexistence of different magnetic phases in the manganites studied, with the addition of Cu contributing to the weakening of the double-exchange interaction in most parts of the material.
Resumo:
The air fluorescence detector of the Pierre Auger Observatory is designed to perforin calorimetric measurements of extensive air showers created by Cosmic rays of above 10(18) eV. To correct these measurements for the effects introduced by atmospheric fluctuations, the Observatory contains a group Of monitoring instruments to record atmospheric conditions across the detector site, ail area exceeding 3000 km(2). The atmospheric data are used extensively in the reconstruction of air showers, and are particularly important for the correct determination of shower energies and the depths of shower maxima. This paper contains a summary of the molecular and aerosol conditions measured at the Pierre Auger Observatory since the start of regular operations in 2004, and includes a discussion of the impact of these measurements oil air shower reconstructions. Between 10(18) and 10(20) eV, the systematic Uncertainties due to all atmospheric effects increase from 4% to 8% in measurements of shower energy, and 4 g cm(-2) to 8 g cm(-2) in measurements of the shower maximum. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
We developed an analytical method and constrained procedural boundary conditions that enable accurate and precise Zn isotope ratio measurements in urban aerosols. We also demonstrate the potential of this new isotope system for air pollutant source tracing. The procedural blank is around 5 ng and significantly lower than published methods due to a tailored ion chromatographic separation. Accurate mass bias correction using external correction with Cu is limited to Zn sample content of approximately 50 ng due to the combined effect of blank contribution of Cu and Zn from the ion exchange procedure and the need to maintain a Cu/Zn ratio of approximately 1. Mass bias is corrected for by applying the common analyte internal standardization method approach. Comparison with other mass bias correction methods demonstrates the accuracy of the method. The average precision of delta(66)Zn determinations in aerosols is around 0.05% per atomic mass unit. The method was tested on aerosols collected in Sin Paulo City, Brazil. The measurements reveal significant variations in delta(66)Zn(Imperial) ranging between -0.96 and -0.37% in coarse and between -1.04 and 0.02% in fine particular matter. This variability suggests that Zn isotopic compositions distinguish atmospheric sources. The isotopic light signature suggests traffic as the main source. We present further delta(66)Zn(Imperial) data for the standard reference material NIST SRM 2783 (delta 66Z(Imperial) = 0.26 +/- 0.10%).
Resumo:
Proteins have been considered important targets for reactive oxygen species. Indeed, tryptophan (W) has been shown to be a highly susceptible amino acid to many oxidizing agents, including singlet molecular oxygen [O-2 ((1)Delta(g))]. In this study, two cis- and trans-tryptophan hydroperoxide (WOOH) isomers were completely characterized by HPLC/mass spectrometry and NMR analyses as the major W-oxidation photoproducts. These photoproducts underwent thermal decay into the corresponding alcohols. Additionally, WOOHs were shown to decompose under heating or basification, leading to the formation of N-formylkynurenine (FMK). Using O-18-labeled hydroperoxides ((WOOH)-O-18-O-18), it was possible to confirm the formation of two oxygen-labeled FMK molecules derived from (WOOH)-O-18-O-18 decomposition. This result demonstrates that both oxygen atoms in FMK are derived from the hydroperoxide group. In addition, these reactions are chemiluminescent (CL), indicating a dioxetane cleavage pathway. This mechanism was confirmed since the CL spectrum of the WOOH decomposition matched the FMK fluorescence spectrum, unequivocally identifying FMK as the emitting species.