45 resultados para system design for VANETs
Resumo:
Recently, the development of industrial processes brought on the outbreak of technologically complex systems. This development generated the necessity of research relative to the mathematical techniques that have the capacity to deal with project complexities and validation. Fuzzy models have been receiving particular attention in the area of nonlinear systems identification and analysis due to it is capacity to approximate nonlinear behavior and deal with uncertainty. A fuzzy rule-based model suitable for the approximation of many systems and functions is the Takagi-Sugeno (TS) fuzzy model. IS fuzzy models are nonlinear systems described by a set of if then rules which gives local linear representations of an underlying system. Such models can approximate a wide class of nonlinear systems. In this paper a performance analysis of a system based on IS fuzzy inference system for the calibration of electronic compass devices is considered. The contribution of the evaluated IS fuzzy inference system is to reduce the error obtained in data acquisition from a digital electronic compass. For the reliable operation of the TS fuzzy inference system, adequate error measurements must be taken. The error noise must be filtered before the application of the IS fuzzy inference system. The proposed method demonstrated an effectiveness of 57% at reducing the total error based on considered tests. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
A new concept and a preliminary study for a monocolumn floating unit are introduced, aimed at exploring and producing oil in ultradeep waters. This platform, which combines two relevant features-great oil storage capacity and dry tree production capability-comprises two bodies with relatively independent heave motions between them. A parametric model is used to define the main design characteristics of the floating units. A set of design alternatives is generated using this procedure. These solutions are evaluated in terms of stability requirements and dynamic response. A mathematical model is developed to estimate the first order heave and pitch motions of the platform. Experimental tests are carried out in order to calibrate this model. The response of each body alone is estimated numerically using the WAMIT (R) code. This paper also includes a preliminary study on the platform mooring system and appendages. The study of the heave plates presents the gain, in terms of decreasing the motions, achieved by the introduction of the appropriate appendages to the platform. [DOI: 10.1115/1.4001429]
Resumo:
An adequate supply of nitrogen is essential for high yield of common bean seeds; however, the responses to this nutrient in no-tillage systems can vary in function of the species and the amount of straw present. The aim of this research was to evaluate response of the common bean to N in no-tillage systems over maize, millet and Brachiaria brizantha crop residues. Three experiments were conducted, one for each gramineous species. The experimental design was a randomized block in a 5x2x2 factorial scheme, with five N doses (0, 30, 60, 90, 120 kg ha(-1)), in two distinct stadia during the vegetative development (3(rd) and 6(th) trifoliate leaf) and two common bean cultivars (IPR Juriti and Perola), with four replications. The IPR Juriti produced a greater number of pods per plant and showed lower mass per 100 seeds than Perola. It did not show variation in bean yield when the sidedressing N application was carried out in the 3(rd) or 6(th) trifoliate leaf stadia. Based on the obtained results, one concludes that the seed productivity of common beans increases linearly with N doses in a no-tillage system over maize residues.
Resumo:
Rutin, one of the major flavonoids found in an assortment of plants, was reported to act as a sun protection factor booster with high anti-UVA defense, antioxidant, antiaging, and anticellulite, by improvement of the cutaneous microcirculation. This research work aimed at evaluating the rutin in vitro release from semisolid systems, in vertical diffusion cells, containing urea, isopropanol and propylene glycol, associated or not, according to the factorial design with two levels with center point. Urea (alone and in association with isopropanol and propylene glycol) and isopropanol (alone and in association with propylene glycol) influenced significant and negatively rutin liberation in diverse parameters: flux (g/cm2.h); apparent permeability coefficient (cm/h); rutin amount released (g/cm2); and liberation enhancement factor. In accordance with the results, the presence of propylene glycol 5.0% (wt/wt) presented statistically favorable to promote rutin release from this semisolid system with flux = 105.12 8.59 g/cm2.h; apparent permeability coefficient = 7.01 0.572 cm/h; rutin amount released = 648.80 53.01 g/cm2; and liberation enhancement factor = 1.21 0.07.
Resumo:
A simplex-lattice statistical project was employed to study an optimization method for a preservative system in an ophthalmic suspension of dexametasone and polymyxin B. The assay matrix generated 17 formulas which were differentiated by the preservatives and EDTA (disodium ethylene diamine-tetraacetate), being the independent variable: X-1 = chlorhexidine digluconate (0.010 % w/v); X-2 = phenylethanol (0.500 % w/v); X-3 = EDTA (0.100 % w/v). The dependent variable was the Dvalue obtained from the microbial challenge of the formulas and calculated when the microbial killing process was modeled by an exponential function. The analysis of the dependent variable, performed using the software Design Expert/W, originated cubic equations with terms derived from stepwise adjustment method for the challenging microorganisms: Pseudomonas aeruginosa, Burkholderia cepacia, Staphylococcus aureus, Candida albicans and Aspergillus niger. Besides the mathematical expressions, the response surfaces and the contour graphics were obtained for each assay. The contour graphs obtained were overlaid in order to permit the identification of a region containing the most adequate formulas (graphic strategy), having as representatives: X-1 = 0.10 ( 0.001 % w/v); X-2 = 0.80 (0.400 % w/v); X-3 = 0.10 (0.010 % w/v). Additionally, in order to minimize responses (Dvalue), a numerical strategy corresponding to the use of the desirability function was used, which resulted in the following independent variables combinations: X-1 = 0.25 (0.0025 % w/v); X-2 = 0.75 (0.375 % w/v); X-3 = 0. These formulas, derived from the two strategies (graphic and numerical), were submitted to microbial challenge, and the experimental Dvalue obtained was compared to the theoretical Dvalue calculated from the cubic equation. Both Dvalues were similar to all the assays except that related to Staphylococcus aureus. This microorganism, as well as Pseudomonas aeruginosa, presented intense susceptibility to the formulas independently from the preservative and EDTA concentrations. Both formulas derived from graphic and numerical strategies attained the recommended criteria adopted by the official method. It was concluded that the model proposed allowed the optimization of the formulas in their preservation aspect.
Resumo:
The influence of four variables, specifically PEG molar mass (400, 1,000, and 8,000 g/mol), concentrations of PEG and phosphate salts (15, 20, and 25% for both), and agitation intensity (110, 150, and 200 rpm), on clavulanic acid (CA) extraction by extractive fermentation with PEG/phosphate salts aqueous two-phase system was investigated in shaken flasks using a 2(4-1)-fractional factorial design. After selection of the two most significant variables (agitation intensity and PEG molar mass), an optimization study conducted according to a 2(2)-central composite design revealed that 25% PEG 8,000 g/mol and phosphate salts at 240 rpm (run 6) were the best conditions for the extractive fermentation, leading to the best results in terms of partition coefficient (k = 8.2), yield of CA in the PEG-rich phase (eta(T) = 93%) and productivity (P = 5.3 mg/Lh). As a first attempt to make a scale-up of these results, the effectiveness of the extractive fermentation was then checked in a bench-scale bioreactor under conditions as close as possible to the optimum ones determined in flasks. The highest CA concentration obtained in the PEG-rich phase (691 mg/L) was 30% higher than in flasks, thus demonstrating the potential of such a new process, integrating the production and extraction steps, as a promising, low-cost tool to obtain high yields of this and similar products. (C) 2010 American Institute of Chemical Engineers Biotechnol. Prog., 27: 95-103, 2011
Resumo:
A 2(3-1) factorial experimental design was used to evaluate the performance of a perforated rotating disc contactor to extract alpha-toxin from the fermented broth of Clostridium perfringens Type A by aqueous two-phase system of polyethylene glycol-phosphate salts. The influence of three independent variables, specifically the dispersed phase flowrate, the continuous phase flowrate and the disc rotational speed, was investigated on the hold up, the mass transfer coefficient, the separation efficiency and the purification factor, taken as the response variables. The optimum dispersed phase flowrate was 3.0 mL/min for all these responses. Besides, maximum values of hold up (0.80), separation efficiency (0. 10) and purification factor (2.4) were obtained at this flowrate using the lowest disc rotational speed (35 rpm), while the optimum mass transfer coefficient (0. 165 h(-1)) was achieved at the highest agitation level (140 rpm). The results of this study demonstrated that the dispersed phase flowrate strongly influenced the performance of PRDC, in that both the mass transfer coefficient and hold up increased with this parameter. (c) 2007 Elsevier B. V. All rights reserved.
Resumo:
A partial pseudo-ternary phase diagram has been studied for the cethyltrimethylammonium bromide/isooctane:hexanol:butanol/potassium phosphate buffer system, where the two-phase diagram consisting of the reverse micelle phase (L-2) in equilibrium with the solvent is indicated. Based on these diagrams two-phase systems of reverse micelles were prepared with different compositions of the compounds and used for extraction and recovery of two enzymes, and the percentage of enzyme recovery yield monitored. The enzymes glucose-6-phosphate dehydrogenase (G6PD) and xylose redutase (XR) obtained from Candida guilliermondii yeast were used in the extraction procedures. The recovery yield data indicate that micelles having different composition give selective extraction of enzymes. The method can thus be used to optimize enzyme extraction processes. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
Background: Perioperative complications following robotic-assisted radical prostatectomy (RARP) have been previously reported in recent series. Few studies, however, have used standardized systems to classify surgical complications, and that inconsistency has hampered accurate comparisons between different series or surgical approaches. Objective: To assess trends in the incidence and to classify perioperative surgical complications following RARP in 2500 consecutive patients. Design, setting, and participants: We analyzed 2500 patients who underwent RARP for treatment of clinically localized prostate cancer (PCa) from August 2002 to February 2009. Data were prospectively collected in a customized database and retrospectively analyzed. Intervention: All patients underwent RARP performed by a single surgeon. Measurements: The data were collected prospectively in a customized database. Complications were classified using the Clavien grading system. To evaluate trends regarding complications and radiologic anastomotic leaks, we compared eight groups of 300 patients each, categorized according the surgeon`s experience (number of cases). Results and limitations: Our median operative time was 90 min (interquartile range [IQR]: 75-100 min). The median estimated blood loss was 100 ml (IQR: 100-150 ml). Our conversion rate was 0.08%, comprising two procedures converted to standard laparoscopy due to robot malfunction. One hundred and forty complications were observed in 127 patients (5.08%). The following percentages of patients presented graded complications: grade 1, 2.24%; grade 2, 1.8%; grade 3a, 0.08%; grade 3b, 0.48%; grade 4a, 0.40%. There were no cases of multiple organ dysfunction or death (grades 4b and 5). There were significant decreases in the overall complication rates (p = 0.0034) and in the number of anastomotic leaks (p < 0.001) as the surgeon`s experience increased. Conclusions: RARP is a safe option for treatment of clinically localized PCa, presenting low complication rates in experienced hands. Although the robotic system provides the surgeon with enhanced vision and dexterity, proficiency is only accomplished with consistent surgical volume; complication rates demonstrated a tendency to decrease as the surgeon`s experience increased. (C) 2010 European Association of Urology. Published by Elsevier B. V. All rights reserved.
Resumo:
Objective: To develop a model to predict the bleeding source and identify the cohort amongst patients with acute gastrointestinal bleeding (GIB) who require urgent intervention, including endoscopy. Patients with acute GIB, an unpredictable event, are most commonly evaluated and managed by non-gastroenterologists. Rapid and consistently reliable risk stratification of patients with acute GIB for urgent endoscopy may potentially improve outcomes amongst such patients by targeting scarce health-care resources to those who need it the most. Design and methods: Using ICD-9 codes for acute GIB, 189 patients with acute GIB and all. available data variables required to develop and test models were identified from a hospital medical records database. Data on 122 patients was utilized for development of the model and on 67 patients utilized to perform comparative analysis of the models. Clinical data such as presenting signs and symptoms, demographic data, presence of co-morbidities, laboratory data and corresponding endoscopic diagnosis and outcomes were collected. Clinical data and endoscopic diagnosis collected for each patient was utilized to retrospectively ascertain optimal management for each patient. Clinical presentations and corresponding treatment was utilized as training examples. Eight mathematical models including artificial neural network (ANN), support vector machine (SVM), k-nearest neighbor, linear discriminant analysis (LDA), shrunken centroid (SC), random forest (RF), logistic regression, and boosting were trained and tested. The performance of these models was compared using standard statistical analysis and ROC curves. Results: Overall the random forest model best predicted the source, need for resuscitation, and disposition with accuracies of approximately 80% or higher (accuracy for endoscopy was greater than 75%). The area under ROC curve for RF was greater than 0.85, indicating excellent performance by the random forest model Conclusion: While most mathematical models are effective as a decision support system for evaluation and management of patients with acute GIB, in our testing, the RF model consistently demonstrated the best performance. Amongst patients presenting with acute GIB, mathematical models may facilitate the identification of the source of GIB, need for intervention and allow optimization of care and healthcare resource allocation; these however require further validation. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
Study Design. In vitro biomechanical investigation of the screw-holding capacity. Objective. To evaluate the effect of repetitive screw-hole use on the insertional torque and retentive strength of vertebral system screws. Summary and Background Data. Placement and removal of vertebral system screws is sometimes necessary during the surgical procedures in order to assess the walls of the pilot hole. This procedure may compromise the holding capacity of the implant. Methods. Screws with outer diameter measuring 5, 6, and 7 mm were inserted into wood, polyurethane, polyethylene, and cancellous bone cylindrical blocks. The pilot holes were made with drills of a smaller, equal, or wider diameter than the inner screw diameter. Three experimental groups were established based on the number of insertions and reinsertions of the screws and subgroups were created according to the outer diameter of the screw and the diameter of the pilot hole used. Results. A reduction of screw-holding capacity was observed between the first and the following insertions regardless the anchorage material. The pattern of reduction of retentive strength was not similar to the pattern of torque reduction. The pullout strength was more pronounced between the first and the last insertions, while the torque decreased more proportionally from the first to the last insertions. Conclusion. Insertion and reinsertion of the screws of the vertebral fixation system used in the present study reduced the insertion torque and screw purchase.
Resumo:
Background: The study was conducted to evaluate the cardiovascular risk markers associated with endometriosis and the influence of the levonorgestrel intrauterine system (LNG-TUS) compared with the GnRH analogue (GnRHa) leuprolide acetate on these risk markers after 6 months of treatment. Study Design: This was a randomized, prospective, open clinical Study, with 44 patients with laparoscopically and histologically confirmed endometriosis. Patients were randomized into two groups: the LNG-IUS group, composed of 22 patients who underwent LNG-IUS insertion., and the GnRHa group, composed of 22 patients who received a monthly GnRHa injection for 6 months. Body mass index systolic and diastolic arterial blood pressure; heart rate; and laboratory cardiovascular risk markers such as interlelikin-6 (IL-6), tumor necrosis factor-alpha (TNF-alpha), C-reactive protein (CRP), homocysteine (HMC), lipid profile, total leukocytes and vascular cell adhesion molecule (VCAM) were measured before and 6 months after treatment. Results: After 6 months of treatment, a significant reduction in pain score occurred in both groups with no significant difference in improvement between the two medications evaluated. In the LNG-IUS group, from pretreatment to posttreatment period, there was a significant reduction in the levels (mean +/- SD) of VCAM (92.8 +/- 4.2 to 91.2 +/- 2.7 ng/mL, p=.04), CRP (0.38 +/- 0.30 to 0.28 +/- 0.21 mg/dL, p=.03), total cholesterol (247.0 +/- 85.0 to 180.0 +/- 31.0 mg/dL, p=.0002), triglycerides (118.0 +/- 76.0 to 86.5 +/- 41.5 mg/dL, p=.003), low-density lipoprotein cholesterol (160.5 +/- 66.0 to 114.5 +/- 25.5 mg/dL, p=.0005) and high-density lipoprotein cholesterol (63.0 +/- 20.5 to 48.5 +/- 10.5 mg/dL, p=.002). The GnRHa group showed an increase in HMC levels (11.5 +/- 2.9 to 13.0 +/- 2.7 mu mol/L, p=.04) and a reduction in IL-6 levels (4.3 +/- 3.9 to 2.3 +/- 0.8 pg/mL, p=.005), VCAM (94.0 +/- 3.8 to 92.0 +/- 1.6 ng/mL, p=.03) and total leukocytes (7330 +/- 2554 to 6350 +/- 1778, p=.01). In the GnRH group, the remaining variables, including lipid profile, did not show any statistical difference. Conclusions: This study shows that some cardiovascular risk markers are influenced by both GnRHa and the LNG-TUS, but the latter had a greater positive impact on the lipid profile, which could lead to a favorable effect during long-term treatment. (C) 2010 Elsevier Inc. All rights reserved.
Resumo:
Immunological systems have been an abundant inspiration to contemporary computer scientists. Problem solving strategies, stemming from known immune system phenomena, have been successfully applied to chall enging problems of modem computing. Simulation systems and mathematical modeling are also beginning use to answer more complex immunological questions as immune memory process and duration of vaccines, where the regulation mechanisms are not still known sufficiently (Lundegaard, Lund, Kesmir, Brunak, Nielsen, 2007). In this article we studied in machina a approach to simulate the process of antigenic mutation and its implications for the process of memory. Our results have suggested that the durability of the immune memory is affected by the process of antigenic mutation.and by populations of soluble antibodies in the blood. The results also strongly suggest that the decrease of the production of antibodies favors the global maintenance of immune memory.
Resumo:
Purpose: The aim of this research was to assess the dimensional accuracy of orbital prostheses based on reversed images generated by computer-aided design/computer-assisted manufacturing (CAD/CAM) using computed tomography (CT) scans. Materials and Methods: CT scans of the faces of 15 adults, men and women older than 25 years of age not bearing any congenital or acquired craniofacial defects, were processed using CAD software to produce 30 reversed three-dimensional models of the orbital region. These models were then processed using the CAM system by means of selective laser sintering to generate surface prototypes of the volunteers` orbital regions. Two moulage impressions of the faces of each volunteer were taken to manufacture 15 pairs of casts. Orbital defects were created on the right or left side of each cast. The surface prototypes were adapted to the casts and then flasked to fabricate silicone prostheses. The establishment of anthropometric landmarks on the orbital region and facial midline allowed for the data collection of 31 linear measurements, used to assess the dimensional accuracy of the orbital prostheses and their location on the face. Results: The comparative analyses of the linear measurements taken from the orbital prostheses and the opposite sides that originated the surface prototypes demonstrated that the orbital prostheses presented similar vertical, transversal, and oblique dimensions, as well as similar depth. There was no transverse or oblique displacement of the prostheses. Conclusion: From a clinical perspective, the small differences observed after analyzing all 31 linear measurements did not indicate facial asymmetry. The dimensional accuracy of the orbital prostheses suggested that the CAD/CAM system assessed herein may be applicable for clinical purposes. Int J Prosthodont 2010;23:271-276.
Resumo:
Objectives: To evaluate the effect of framework design on the fatigue life and failure modes of metal ceramic (MC, Ni-Cr alloy core, VMK 95 porcelain veneer), glass-infiltrated alumina (ICA, In-Ceram Alumina/VM7), and veneered yttria-stabilized tetragonal zirconia polycrystals (Y-TZP, IPSe.max ZirCAD/IPS e.max,) crowns. Methods: Sixty composite resin tooth replicas of a prepared maxillary first molar were produced to receive crowns systems of a standard (MCs, ICAs, and Y-TZPs, n = 10 each) or a modified framework design (MCm, ICAm, and Y-TZPm, n = 10 each). Fatigue loading was delivered with a spherical steel indenter (3.18 mm radius) on the center of the occlusal surface using r-ratio fatigue (30-300 N) until completion of 10(6) cycles or failure. Fatigue was interrupted every 125,000 cycles for damage evaluation. Weibull distribution fits and contour plots were used for examining differences between groups. Failure mode was evaluated by light polarized and SEM microscopy. Results: Weibull analysis showed the highest fatigue life for MC crowns regardless of framework design. No significant difference (confidence bound overlaps) was observed between ICA and Y-TZP with or without framework design modification. Y-TZPm crowns presented fatigue life in the range of MC crowns. No porcelain veneer fracture was observed in the MC groups, whereas ICAs presented bulk fracture and ICAm failed mainly through the veneer. Y-TZP crowns failed through chipping within the veneer, without core fractures. Conclusions: Framework design modification did not improve the fatigue life of the crown systems investigated. Y-TZPm crowns showed comparable fatigue life to MC groups. Failure mode varied according to crown system. (C) 2010 Elsevier Ltd. All rights reserved.