46 resultados para electronic surveillance
Resumo:
A quantitative correlation between the glass forming ability and the electronic parameters of metallic alloys is presented. It is found that the critical cooling rate for glass formation (R(c)) correlates well with the average work function difference (Delta phi) and the average electron density difference (Delta n(ws)(1/3)) among the constituent elements of the investigated alloys. A correlation coefficient (R(2)) of 0.77 was found for 68 alloys in 30 metallic systems, which is better than the previous proposed correlation between the glass forming ability and the average Pauling electronegativity difference.
Resumo:
Thyristor-based onload tap-changing ac voltage stabilizers are cheap and robust. They have replaced most mechanical tap-changers in low voltage applications from 300 VA to 300 M. Nevertheless, this replacement hardily applies to tap-changers associated to transformers feeding medium-voltage lines (typically 69 kV primary, 34.5 kV line, 10 MVA) which need periodical maintenance of contacts and oil. The Electric Power Research Institute (EPRI) has studied the feasibility of this replacement. It detected economical problems derived from the need for series association of thyristors to manage the high voltages involved, and from the current overload developed under line fault. The paper reviews the configurations used in that field and proposes new solutions, using a compensating transformer in the main circuit and multi-winding coils in the commutating circuit, with reduced overload effect and no series association of thyristors, drastically decreasing their number and rating. The stabilizer can be installed at any point of the line and the electronic circuit can be fixed to ground. Subsequent works study and synthesize several commutating circuits in detail.
Resumo:
Every year, the number of discarded electro-electronic products is increasing. For this reason recycling is needed, to avoid wasting non-renewable natural resources. The objective of this work is to study the recycling of materials from parallel wire cable through Unit operations of mineral processing. Parallel wire cables are basically composed of polymer and copper. The following unit operations were tested: grinding, size classification, dense medium separation, electrostatic separation, scrubbing, panning, and elutriation. It was observed that the operations used obtained copper and PVC concentrates with a low degree of cross contamination. It was Concluded that total liberation of the materials was accomplished after grinding to less than 3 mm, using a cage mill. Separation using panning and elutriation presented the best results in terms of recovery and cross contamination. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
The goal of this work is to study and relate electrical and optical properties of diamond-like carbon (DLC) thin films for applications in electronic devices. DLC films were deposited in a reactive RF magnetron sputtering system on p-type silicon and glass substrates. The target was a 99.9999% pure, 6 in. diameter graphite plate and methane was used as processing gas. Eight DLC films were produced for each substrate, varying deposition time, the reactor pressure between 5 mTorr and 10 mTorr while the RF power was applied at 13.56 MHz and varied between 100, 150, 200 and 250W. After deposition, the films were analyzed by I-V and C-V measurements (Cheng et al. (2004) [1]) in order to determine the electric resistivity, photo-current response and dielectric constant, optical transmittance, used to find the optical gap by the Tauc method; and by photoluminescence analysis to determine the photoemission and confirm the optical band gap. These characteristics are compared and the influence of the deposition parameters is discussed. (C) 2011 Published by Elsevier B.V.
Resumo:
Recently, the development of industrial processes brought on the outbreak of technologically complex systems. This development generated the necessity of research relative to the mathematical techniques that have the capacity to deal with project complexities and validation. Fuzzy models have been receiving particular attention in the area of nonlinear systems identification and analysis due to it is capacity to approximate nonlinear behavior and deal with uncertainty. A fuzzy rule-based model suitable for the approximation of many systems and functions is the Takagi-Sugeno (TS) fuzzy model. IS fuzzy models are nonlinear systems described by a set of if then rules which gives local linear representations of an underlying system. Such models can approximate a wide class of nonlinear systems. In this paper a performance analysis of a system based on IS fuzzy inference system for the calibration of electronic compass devices is considered. The contribution of the evaluated IS fuzzy inference system is to reduce the error obtained in data acquisition from a digital electronic compass. For the reliable operation of the TS fuzzy inference system, adequate error measurements must be taken. The error noise must be filtered before the application of the IS fuzzy inference system. The proposed method demonstrated an effectiveness of 57% at reducing the total error based on considered tests. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
[Ru(3)O(CH(3)COO)(6)(pz)(CO)](6) is a cyclic hexamer species encompassing six triangular ruthenium cluster centers bridged by pyrazine ligands. The electronic communication among the cluster units strongly depends on their oxidation states, and has been successfully probed by means of cyclic voltammetry and UV-vis spectroelectrochemistry. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Background Stroke mortality rates in Brazil are the highest in the Americas. Deaths from cerebrovascular disease surpass coronary heart disease. Aim To verify stroke mortality rates and morbidity in an area of Sao Paulo, Brazil, using the World Health Organization Stepwise Approach to Stroke Surveillance. Methods We used the World Health Organization Stepwise Approach to Stroke Surveillance structure of stroke surveillance. The hospital-based data comprised fatal and nonfatal stroke (Step 1). We gathered stroke-related mortality data in the community using World Health Organization questionnaires (Step 2). The questionnaire determining stroke prevalence was activated door to door in a family-health-programme neighbourhood (Step 3). Results A total of 682 patients 18 years and above, including 472 incident cases, presented with cerebrovascular disease and were enrolled in Step 1 during April-May 2009. Cerebral infarction (84 center dot 3%) and first-ever stroke (85 center dot 2%) were the most frequent. In Step 2, 256 deaths from stroke were identified during 2006-2007. Forty-four per cent of deaths were classified as unspecified stroke, 1/3 as ischaemic stroke, and 1/4 due to haemorrhagic subtype. In Step 3, 577 subjects over 35 years old were evaluated at home, and 244 cases of stroke survival were diagnosed via a questionnaire, validated by a board-certified neurologist. The population demographic characteristics were similar in the three steps, except in terms of age and gender. Conclusion By including data from all settings, World Health Organization stroke surveillance can provide data to help plan future resources that meet the needs of the public-health system.
Resumo:
To describe the effect of active surveillance to control vancomycin-resistant enterococci (VRE) after an outbreak, 549 surveillance rectal cultures were performed in 308 patients (35% positive). An educational intervention to prevent transmission was implemented. Infection and colonization by VR-Enterococcus faecalis decreased, but Enterococcus faecium persisted despite control measures. Infections by VR-E faecalis fell to zero in 2008. We observed difficulties in controlling colonization with measures directed mainly by surveillance cultures and differences between responses of E faecium and E faecalis.
Resumo:
Dopamine agonists are the treatment of choice for prolactinomas. However, there are still controversies concerning dose, treatment duration and criteria for drug withdrawal in different clinical situations. The aim of this study was to assess diagnostic and therapeutic approaches to prolactinomas among members of the Brazilian Society of Endocrinology and Metabolism (SBEM). SBEM members answered a questionnaire sent by e-mail that included 18 questions related to controversial issues about the management of prolactinomas. Among SBEM members, 721 (approximately 24% of total) answered the questionnaire. Concerning the diagnosis, 38% of the respondents stated that prolactin levels < 100 ng/ml would exclude the presence of a prolactinoma. Most of them favored the screening for macroprolactin in asymptomatic individuals instead of a routine screening (74% vs. 26%). Regarding the treatment, 70% of the respondents chose cabergoline as the drug of choice to treat macroprolactinomas whereas similar proportions advised cabergoline or bromocriptine as the best treatment for microprolactinomas (52% vs. 48%). Only 20% and 34% of respondents favored treatment withdrawal 2-3 years after prolactin normalization in patients with macroprolactinomas and microprolactinomas, respectively. In case of pregnancy, only 58 and 70% of respondents advocated discontinuation of treatment with dopamine agonists in patients with macroprolactinomas and microprolactinomas, respectively. Finally, only 36% would allow breast-feeding without restriction, 44% would restrict it to patients with microprolactinomas and 20% would not recommend it for women with prolactinomas There are several points of disagreement among SBEM members regarding the management of prolactinomas.
Resumo:
Group C rotavirus (GpCRV) has a worldwide distribution; however, its epidemiology and ecology are still unclear. Evidence for a possible zoonotic role has been postulated recently for Brazilian children strains. The aim of this study was to monitor GpCRV in children <= 15 years with acute gastroenteritis during the 2007-2010 national Brazilian rotavirus surveillance, and to undertake the molecular characterization of the major VP6 capsid protein. A total of 3,019 fecal samples were first screened for Group A rotavirus (GpARV). A total of 2,205 GpARV ELISA negative samples were tested further for the presence of GpCRV by SDS-PAGE, electronic microscopy, and RT-PCR for the VP6 gene. The genetic diversity of GpCRV was carried out by sequencing the VP6 gene. GpARV and GpCRV infections were detected in 24.6% (742/3,019) and 0.3% (8/3,019), respectively. The GpCRV detection rate increased from 0.2% (1/422) in 2007 to 1% (7/708) in 2008, and GpCRV cases were not detected in 2009 and 2010. The phylogenetic analysis indicated that the strains belonged to the human lineage, and showed a genetic relationship with the GpCRV strain from Japan isolated in 2009. None of the study sequences was related closely to animal GpCRV strains. This study provides further evidence that GpCRV is a minor cause of acute childhood gastroenteritis in Brazil, and does not suggest that GpCRV may assume epidemiological importance in the future, even after the introduction of a GpARV vaccine. In addition, the molecular analyses of the GpCRV samples in this study do not support the zoonotic hypothesis. J. Med. Virol. 83: 1631-1636, 2011. (C) 2011 Wiley-Liss, Inc.
Resumo:
Objective: To propose an electronic method for sensitivity evaluation in leprosy and to compare it to the Semmes-Weinstein monofilaments. Methods:Thirty patients attending the Dermatology outpatient clinic of HCFMRP-USP were consecutively evaluated by both the electronic aesthesiometer and Semmes-Weinstein monofilaments on hand and foot test points. The intraclass correlation coefficient (ICC) was calculated to determine the variability of the electronic measures and the Kappa coefficient was calculated to determine the agreement between methods according to their categories (altered and non-altered tactile sensitivity). Results: The ICC was approximately 1, demonstrating repeatability. The Kappa coefficient showed more than 75 and 63% agreement on the hand and foot points, respectively. The mean agreement between the 2 methods for the 7 points of the right and left hand was 77.14 and 75.71%, respectively. The mean agreement for all 10 points was 74.33 and 63.66% on the right and left foot, respectively. In cases of disagreement the detection of altered tactile sensitivity by the electronic esthesiometer on the right and left foot was 90.91 and 84.25%, respectively, with no detection by the monofilaments. Conclusion: The results suggest that the electronic esthesiometer is a reliable and easy application, capable of evaluating alterations of tactile sensitivity in leprosy patients. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Introduction. Capybaras (Hydrochoerus hydrochaeris) are considered amplifying hosts of Rickettsia sp. These rodents are usually parasitized by the tick vector, Amblyomma cajennense, the main vector of rickettsioses in humans and animals in South America. Capybaras can be used as sentinels in detection of circulation of rickettsiae. Objective. Antibodies to rickettsiae of spotted fever group were detected in capybaras in a rural area of Cordoba Province, northern Colombia. Materials and methods. Sera were analyzed from 36 capybaras in a rural area of Monteria (village of San Jeronimo) in Cordoba. For the detection of IgG antibodies, indirect immunofluorescence was performed. The antigens were derived from R. rickettsia strain Taiacu isolated in Brazil. Capybara sera were diluted 1:64 for IFA analysis. Ticks were collected from each capybara (also known as chiguiro) and identified to species. Results. The seroprevalence of spotted fever group Rickettsia was 22% (8 capybaras). Four sera had a titer of 1:64, 3 had a titer of 1:128 and one serum had a titer of 1:512. All ticks removed from the capybaras (n=933) were taxonomically identified as Amblyomma cajennense. Conclusion. Colombia has areas endemic for rickettsioses, as indicated by confirmed annual outbreaks. The current study reports the first evidence of natural rickettsial infection of the spotted fever group in capybaras from Colombia. The findings suggest that capybaras can be used as sentinels for the circulation of rickettsiae and can identify endemic areas for the transmission of rickettsial diseases.
Resumo:
Objectives. The objectives of this study were to assess the accuracy of working length determination using 3 electronic apex locators and direct digital radiography and to compare the results with those obtained using the visual method (control measurement). Study design. Twenty extracted human maxillary premolars were selected: 17 two-rooted and 3 single-rooted (total of 37 canals). Working length was measured using electronic apex locators Elements Diagnostic, Root ZX, and Just II. Subsequently, teeth were positioned in the alveolar bone of a dry skull and submitted to direct digital radiography. A variation of +/- 1 mm was considered as acceptable. Results were analyzed using the Wilcoxon and the chi(2) tests. Results. Results presented an accuracy of 94.6% for Elements Diagnostic, 91.9% for Root ZX, 73.0% for Just II, and 64.9% for direct digital radiography when considering the margin of +/- 1 mm in relation to the control measurement. Comparisons with the actual control measurements resulted in accuracy results of 13.51%, 13.51%, 10.10%, and 2.70%, respectively. Conclusions. Root ZX and Elements Diagnostic are more accurate in determining working length when compared with Just II and Schick direct digital radiography. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011;111:e44-e49)
Resumo:
Objective. The aim of this study was to evaluate the precision of working length determination of 3 electronic apex locators (EALs): Root ZX, RomiApex D-30, and Ipex at 0.0 mm, at the apical foramen (AF), and at 1.0 mm short of the AF. Methodology. Thirty-eight mandibular premolars had their real lengths previously determined. Electronic measurements were determined at 1.0 mm, followed by measurements at 0.0 mm, performed in triplicate. Results. Precision of devices at 1.0 mm and 0.0 mm were: 94.7% and 97.4%, respectively (Root ZX); 78.9% and 97.4% (RomiApex D-30); and 76.3% and 97.4% (Ipex). Although no statistical differences were observed between the EALs at 0.0, at 1.0 mm Root ZX performed significantly better than the others. Conclusion. The EALs had acceptable precision when measuring the working length at the AF. However, when used at levels short of the AF, only Root ZX did not suffer a significant negative effect on precision. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010;110:e57-e61)
Resumo:
Introduction: The aim of this study was to compare the influence of preflaring on the accuracy of 4 electronic apex locators (EALs): Root ZX, Elements Diagnostic Unit and Apex Locator, Mini Apex Locator, and Apex DSP. Methods: Forty extracted teeth were preflared by using S1 and SX ProTaper instruments. The working length was established by reducing 1 mm from the total length (TL). The ability of the EALs to detect precise (-1 mm from TL) and acceptable (-1+/-0.5 mm from TL) measurements in unflared and preflared canals was determined. Results: The precise and acceptable (P/A) readings in unflared canals for Root ZX, Elements Diagnostic Unit and Apex Locator, Mini Apex and Apex DSP were 50%/97.5%, 47.5%/95%, 50%/97.5%, and 45%/67.5%, respectively. For preflared canals, the readings were 75%/97.5%, 55%/95%, 75%/97.5%, and 60%/87.5%, respectively. For precise criteria, the preflared procedure increased the percentage of accurate electronic readings for the Root ZX and the Mini Apex Locator (P < .05). For acceptable criteria, no differences were found among Root ZX, Elements Diagnostic Unit and Apex Locator, and Mini Apex Locator (P > .05). Fisher test indicated the lower accuracy for Apex DSP (P < .05). Conclusions: The Root ZX and the Mini Apex Locator devices increased significantly the precision to determine the real working length after the preflaring procedure. All the EALs showed an acceptable determination of the working length between the ranges of+/-0.5mm except for the Apex DSP device, which had the lowest accuracy. (J Endod 2009;35:1300-1302)