104 resultados para Body Temperatures
Resumo:
In this work, we demonstrate field-induced Bose-Einstein condensation (BEC) in the organic compound NiCl(2)-4SC(NH(2))(2) using ac susceptibility measurements down to 1 mK. The Ni S=1 spins exhibit 3D XY antiferromagnetism between a lower critical field H(c1)similar to 2 T and a upper critical field H(c2)similar to 12 T. The results show a power-law temperature dependence of the phase transition line H(c1)(T)-H(c1)(0)=aT(alpha) with alpha=1.47 +/- 0.10 and H(c1)(0)=2.053 T, consistent with the 3D BEC universality class. Near H(c2), a kink was found in the phase boundary at approximately 150 mK.
Resumo:
The mapping, exact or approximate, of a many-body problem onto an effective single-body problem is one of the most widely used conceptual and computational tools of physics. Here, we propose and investigate the inverse map of effective approximate single-particle equations onto the corresponding many-particle system. This approach allows us to understand which interacting system a given single-particle approximation is actually describing, and how far this is from the original physical many-body system. We illustrate the resulting reverse engineering process by means of the Kohn-Sham equations of density-functional theory. In this application, our procedure sheds light on the nonlocality of the density-potential mapping of density-functional theory, and on the self-interaction error inherent in approximate density functionals.
Resumo:
GUALANO, B., M. NEVES JR, F. R. LIMA, A. L. PINTO, G. LAURENTINO, C. BORGES, L. BAPTISTA, G. G. ARTIOLI, M. S. AOKI, A. MORISCOT, A. H. LANCHA JR, E. BONFA, and C. UGRINOWITSCH. Resistance Training with Vascular Occlusion in Inclusion Body Myositis: A Case Study. Med Sci. Spot-is Exerc., Vol. 42, No. 2, pp. 250-254, 2010. Inclusion body myositis (IBM) is a rare idiopathic inflammatory myopathy that produces remarkable muscle weakness. Resistance training with vascular occlusion has been shown to improve muscle strength and cross-sectional area in other muscle wasting conditions. Purpose: We evaluated the efficacy of a moderate-intensity resistance training program combined with vascular occlusion by examining functional capacity, muscle morphology, and changes in the expression of genes related to muscle protein synthesis and proteolysis in a patient with IBM. Methods: A 65-yr-old man with IBM resistant to all proposed treatments underwent resistance training with vascular occlusion for 12 wk. Leg press one-repetition maximum; thigh cross-sectional area; balance, mobility, and muscle function; quality of life; and blood markers of inflammation and muscle damage were assessed at baseline and after the 12-wk program. The messenger RNA (mRNA) expression levels of mechanogrowth factor, mammalian target of rapamycin, atrogin-1, and muscle RING finger-1 were also quantified. Results: After the 12-wk training program, the patient`s leg press one-repetition maximum, balance and mobility function, and thigh cross-sectional area increased 15.9%, 60%, and 4.7%, respectively. All Short Form-36 Health Survey Questionnaire subscales demonstrated improvements as well, varying from 18% to 600%. mRNA expression of mechanogrowth factor increased 3.97-fold, whereas that of atrogin-1 decreased 0.62-fold. Muscle RING finger-1 and mammalian target of rapamycin mRNA levels were only slightly altered, 1.18- and 1.28-fold, respectively. Importantly, the exercise did not induce disease flare. Conclusions: We describe a novel, and likely the first, nonpharmacological therapeutic tool that might be able to counteract the muscle atrophy and the declining strength that usually occur in IBM.
Resumo:
Pires, FO, Hammond, J, Lima-Silva, AE, Bertuzzi, RCM, and Kiss, MAPDM. Ventilation behavior during upper-body incremental exercise. J Strength Cond Res 25(1): 225-230, 2011-This study tested the ventilation (V(E)) behavior during upper-body incremental exercise by mathematical models that calculate 1 or 2 thresholds and compared the thresholds identified by mathematical models with V-slope, ventilatory equivalent for oxygen uptake (V(E)/(V) over dotO(2)), and ventilatory equivalent for carbon dioxide uptake (V(E)/(V) over dotCO(2)). Fourteen rock climbers underwent an upper-body incremental test on a cycle ergometer with increases of approximately 20 W.min(-1) until exhaustion at a cranking frequency of approximately 90 rpm. The V(E) data were smoothed to 10-second averages for V(E) time plotting. The bisegmental and the 3-segmental linear regression models were calculated from 1 or 2 intercepts that best shared the V(E) curve in 2 or 3 linear segments. The ventilatory threshold(s) was determined mathematically by the intercept(s) obtained by bisegmental and 3-segmental models, by V-slope model, or visually by V(E)/(V) over dotO(2) and V(E)/(V) over dotCO(2). There was no difference between bisegmental (mean square error [MSE] = 35.3 +/- 32.7 l.min(-1)) and 3-segmental (MSE = 44.9 +/- 47.8 l.min(-1)) models in fitted data. There was no difference between ventilatory threshold identified by the bisegmental (28.2 +/- 6.8 ml.kg(-1).min(-1)) and second ventilatory threshold identified by the 3-segmental (30.0 +/- 5.1 ml.kg(-1).min(-1)), V(E)/(V) over dotO(2) (28.8 +/- 5.5 ml.kg(-1).min(-1)), or V-slope (28.5 +/- 5.6 ml.kg(-1).min(-1)). However, the first ventilatory threshold identified by 3-segmental (23.1 +/- 4.9 ml.kg(-1).min(-1)) or by VE/(V) over dotO(2) (24.9 +/- 4.4 ml.kg(-1).min(-1)) was different from these 4. The V(E) behavior during upper-body exercise tends to show only 1 ventilatory threshold. These findings have practical implications because this point is frequently used for aerobic training prescription in healthy subjects, athletes, and in elderly or diseased populations. The ventilatory threshold identified by V(E) curve should be used for aerobic training prescription in healthy subjects and athletes.
Resumo:
For percentage of body fat (%BF), there are no internationally accepted cutoffs. The primary function of body fat cutoffs should be to identify not only excessive body fatness, but also the increased risk of unhealthy outcomes, such as hypertension. The purpose of this study was to analyze the accuracy of different %BF and body mass index (BMI) cutoffs as screening measures for EBP in pediatric populations. It was a cross-sectional study with a sample of 358 male subjects from 8 to 18 years old. BP was measured by the oscilometric method, and body composition was measured by dual-energy X-ray absorptiometry (DXA). The accuracy of three reference tables used for body fat cutoffs was assessed. The three body fat reference tables were highly specific, but insensitive, for elevated BP screening. For elevated BP screening, all body fat cutoffs presented similar sensitivity (range=48.3-53.7%) and specificity (range=79.2-84.1%). The body fat cutoffs performed no better than BMI in screening of children and adolescents at risk of elevated BP (EBP). BMI seems a more attractive tool for this function, as it performed similarly and can be applied in large surveys and with lower costs. Hypertension Research (2011) 34, 963-967; doi:10.1038/hr.2011.61; published online 26 May 2011
Resumo:
The goal of this study was to examine the coupling between visual information and body sway with binocular and monocular vision at two distances from the front wall of a moving room. Ten participants stood as still as possible inside of a moving room facing the front wall in conditions that combined room movement with monocular/binocular vision and distance from the front wall (75 and 150cm). Visual information effect on body sway decreased with monocular vision and with increased distance from the front wall. In addition, the combination of monocular vision with the farther distance resulted in the smallest body sway response to the driving stimulus provided by the moving room. These results suggest that binocularvision near the front wall provides visual information of a better quality than the monocular vision far from the front wall. We discuss the results with respect to two modes of visual detection of body sway: ocular and extraocular. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
Resumo:
The effects of different tempering temperatures (300-600 degrees C) on abrasive wear resistance of mottled cast iron were studied. Abrasive wear tests were carried out using the rubber-wheel test on quartz sand and the pin test on Al(2)O(3) abrasive cloths. The retained austenite content of the matrix was determined by X-ray diffraction. The wear surface of the specimens was examined by scanning electron microscopy for identifying the wear micromechanism. Bulk hardness and matrix hardness before and after the tests were measured. The results showed that in the two-body (pin-on-disc test) system, the main wear mechanism was microcutting and high matrix hardening was presented. The wear rates presented higher correlation with the retained austenite than with the bulk and matrix hardness. In the three-body system (sand-rubber wheel), the wear surfaces presented indentations due to abrasive rolling. The wear rates had better correlation with both the bulk and matrix hardness (before and after the wear test) than with the retained austenite content. There are two groups of results, high and low wear rates corresponding to each tribosystem, two-body abrasive wear and three-body abrasive wear, respectively. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
The objective of this work is to develop an improved model of the human thermal system. The features included are important to solve real problems: 3D heat conduction, the use of elliptical cylinders to adequately approximate body geometry, the careful representation of tissues and important organs, and the flexibility of the computational implementation. Focus is on the passive system, which is composed by 15 cylindrical elements and it includes heat transfer between large arteries and veins. The results of thermal neutrality and transient simulations are in excellent agreement with experimental data, indicating that the model represents adequately the behavior of the human thermal system. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
In the unlubricated sliding wear of steels the mild-severe and severe-mild wear transitions have long been investigated. The effect of system inputs such as normal load, sliding speed, environment humidity and temperature, material properties, among others, on those transitions have also been studied. Although transitions seem to be caused by microstructural changes, surfaces oxidation and work-hardening, some questions remain regarding the way each aspect is involved. Since the early studies in sliding wear, it has usually been assumed that only the material properties of the softer body influence the wear behavior of contacting surfaces. For example, the Archard equation involves only the hardness of the softer body, without considering the hardness of the harder body. This work aims to discuss the importance of the harder body hardness in determining the wear regime operation. For this, pin-on-disk wear tests were carried out, in which the disk material was always harder than the pin material. Variations of the friction force and vertical displacement of the pin were registered during the tests. A material characterization before and after tests was conducted using stereoscopy and scanning electron microscopy (SEM) methods, in addition to mass loss, surface roughness and microhardness measurements. The wear results confirmed the occurrence of a mild-severe wear transition when the disk hardness was decreased. The disk hardness to pin hardness ratio (H(d)/H(p)) was used as a criterion to establish the nature of surface contact deformation and to determine the wear regime transition. A predominantly elastic or plastic contact, characterized by H(d)/H(p) values higher or lower than one, results in a mild or severe wear regime operation, respectively. (c) 2009 Elsevier B.V. All rights reserved.
Resumo:
Instrumented indentation has been used to investigate the mechanical properties of BETAMATE 1496 (R) Epoxy adhesive. The properties of the adhesive were analyzed by measuring its hardness and its Young`s modulus in samples extracted from six different positions of the front door of a commercial passenger vehicle in two phases of processing: after application of the adhesive in the door assembling (""pre-cured"" state) and after final cure in the painting oven (""cured"" state). Special attention was given to setting the optimal parameters (""creep"" time and unloading time step) for the instrumented indentation testing for the present application. Young`s modulus values around 1.1 +/- 0.2 GPa and hardness values around 0.15 +/- 0.05 GPa were obtained for all samples, irrespective of the variation of the indentation parameters in the testing procedure and of the relative position of the adhesive in the door frame in both states. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Thermodynamic properties of bread dough (fusion enthalpy, apparent specific heat, initial freezing point and unfreezable water) were measured at temperatures from -40 degrees C to 35 degrees C using differential scanning calorimetry. The initial freezing point was also calculated based on the water activity of dough. The apparent specific heat varied as a function of temperature: specific heat in the freezing region varied from (1.7-23.1) J g(-1) degrees C(-1), and was constant at temperatures above freezing (2.7 J g(-1) degrees C(-1)). Unfreezable water content varied from (0.174-0.182) g/g of total product. Values of heat capacity as a function of temperature were correlated using thermodynamic models. A modification for low-moisture foodstuffs (such as bread dough) was successfully applied to the experimental data. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
A modified cyclone washer was designed, fabricated, and its collection efficiency evaluated. This equipment consists of an American-type cyclone separator with a triple cone and a spray nozzle was introduced into its cylindrical body. The study consisted of an experimental evaluation of the operating conditions at ambient and higher than ambient temperatures, varying chimney height and water flow rate, with the purpose of humidifying the dust. The collection efficiency of the cyclone washer was evaluated particles of micronized quartz with an average diameter of 7.48 mu m and a density of 2.650 g/cm(3). The amount of particles varied from 20-100 mg/m(3) of air. An average efficiency of 97.07 +/- 1.03 % was obtained with four spray nozzles, a chimney height of 0.645 m and 0.358 m(3)/s of gas.
Resumo:
The temperature influence on the gate-induced floating body effect (GIFBE) in fully depleted (FD) silicon-on-insulator (SOI) nMOSFETs is investigated, based on experimental results and two-dimensional numerical simulations. The GIFBE behavior will be evaluated taking into account the impact of carrier recombination and of the effective electric field mobility degradation on the second peak in the transconductance (gm). This floating body effect is also analyzed as a function of temperature. It is shown that the variation of the studied parameters with temperature results in a ""C"" shape of the threshold voltage corresponding with the second peak in the gm curve. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Bovine bone ash is the main raw material for fabrication of bone china, a special kind of porcelain that has visual and mechanical advantages when compared to usual porcelains. The properties of bone china are highly dependent on the characteristics of the bone ash. However, despite a relatively common product, the science behind formulations and accepted fabrication procedures for bone china is not completely understood and deserves attention for future processing optimizations. In this paper, the influence of the preparation steps (firing, milling, and washing of the bones) on the physicochemical properties of bone ash particles was investigated. Bone powders heat-treated at temperatures varying from 700 to 1000 degrees C were washed and milled. The obtained materials were analyzed in terms of particle size distribution, chemical composition, density, specific surface area, FTIR spectroscopy, dynamic electrophoretic mobility, crystalline phases and scanning electron microscopy. The results indicated that bone ash does not significantly change in terms of chemistry and physical features at calcination temperatures above 700 degrees C. After washing in special conditions, one could only observe hydroxyapatite in the diffraction pattern. By FTIR it was observed that carbonate seems to be mainly concentrated on the surface of the powders. Since this compound can influence in the dispersion stability, and consequently in the quality of the final bone china product, and considering optimal washing parameters based on the dynamic electrophoretic mobility results, we describe a procedure for surface cleaning. (c) 2009 Elsevier Ltd and Techna Group S.r.l. All rights reserved.
Resumo:
This work studies the operation of source-follower buffers implemented with standard and graded-channel (GC) fully depleted (FD) SCI nMOSFETs at low temperatures. The analysis is performed by comparing the voltage gain of buffers implemented with GC and standard SOI nMOS transistors considering devices with the same mask channel length and same effective channel length. It is shown that the use of GC devices allows for achieving improved gain in all inversion levels in a wide range of temperatures. In addition, this improvement increases as temperature is reduced. It is shown that GC transistors can provide virtually constant gain, while for standard devices, the gain departs from the maximum value depending on the temperature and inversion level imposed by the bias current and input voltage. Two-dimensional numerical simulations were performed in order to study the reasons for the enhanced gain of GC MOSFETs at low temperatures. (C) 2009 Elsevier Ltd. All rights reserved.