541 resultados para Metals -- Analysis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work characterized the population structure of the hermit crab Loxopagurus loxochelis (Moreira, 1901) in terms of size frequency distribution and sex ratio. Specimens were collected monthly, over a period of one year (from July 2002 to June 2003), in seven transects (from 5 to 35 m of depth) using fishing boat equipped with two double-rig trawl nets, in Caraguatatuba and Ubatuba regions (state of Sao Paulo, Brazil). A total of 366 hermit crabs were collected in Caraguatatuba [222 males (60.65%), 114 non-ovigerous females (31.15%) and 30 ovigerous females (8.20%)] and 126 hermit crabs in Ubatuba [81 males (64.28%), 38 non-ovigerous females (30.16%) and seven ovigerous females (5.56%)]. In Caraguatatuba the highest incidence of ovigerous females occurred during winter (July 2002), whereas in Ubatuba, the number was incipient. The cephalothoracic shield length ranged from 2.0 to 7.9mm (5.29 +/- 0.96mm) in Caraguatatuba, and from 2.7 to 7.5mm (5.32 +/- 0.95mm) in Ubatuba. The mean size of males was significantly larger than the mean size of females in both regions. Overall sex ratio was in favor of males (1.54:1 in Caraguatatuba and 1.9:1 in Ubatuba). Sexual dimorphism was recorded to L. loxochelis by the presence of males in the largest size classes, following the standard pattern observed in Decapoda. There was an unimodal size distribution for both sexes, with normal distributions in both regions. The higher number of males in relation to females may indicate the existence of different growth and mortality rates between the sexes. Despite of the different geomorphologic characteristics between Caraguatatuba and Ubatuba regions, the dynamics of development was similar for both populations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current taxonomy of two poorly known hermit crab species Pagurus forceps H. Milne Edwards, 1836 and Pagurus comptus White, 1847 from temperate Pacific and Atlantic coastlines of South America is based only on adult morphology. Past studies have questioned the separation of these two very similar species, which occur sympatrically. We included specimens morphologically assignable to P. forceps and P. comptus in a phylogenetic analysis, along with other selected anomuran decapods, based on 16S ribosomal gene sequences. Differences between samples putatively assigned to either P. forceps and P. comptus were moderate, with sequence similarity ranging from 98.2 to 99.4% for the fragments analyzed. Our comparison of mitochondrial DNA sequences (16S rRNA) revealed diagnostic differences between the two putative species, suggesting that P. forceps and P. comptus are indeed phylogenetically close but different species, with no genetic justification to support their synonymization. The polyphyly of Pagurus is not corroborated here among the represented Atlantic species, despite obviously complex relationships among the members of the genus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poly(pyrrole) (PPY) coating was prepared on a stainless-steel (SS) wire for solid-phase microextraction (SPME) by electrochemical deposition (cyclic voltammetric). The PPY was evaluated by analyzing new-generation antidepressants (mirtazapine, citalopram, paroxetine, duloxetine, fluoxetine, and sertraline) in plasma sample by SPME and liquid chromatography with UV detection (LC-UV). The effect of electrolyte Solution (lithium perchlorate or tetrabutylammonium perchlorate) and the number of cycles (50, 100 or 200) applied during the polymerization process on the SPME performance was evaluated. Important factors in the optimization of SPME efficiency such as extraction time, temperature, pH, influence of plasma proteins on sorption mechanisms, and desorption conditions are discussed. The SPME-PPY/LC method showed to be linear in concentrations ranging from the limit of quantification (LOQ) to 1200 ng mL(-1). The LOQ values range from 16 to 25 ng mL-1. The inter-day precision of the SPME-PPY/LC method presented coefficient of variation (CV) lower than 15%. Based on analytical validation results, the SPME-PPY/LC methodology showed to be adequate for antidepressant analysis, from therapeutic to toxic levels. In order to evaluate the proposed method for clinical use, the SPME-PPY/LC method was applied to the analysis of plasma samples from elderly depressed patients. (c) 2009 Elsevier B.V. All rights reserved,

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A multilayer organic film containing poly(acrylic acid) and chitosan was fabricated on a metallic support by means of the layer-by-layer technique. This film was used as a template for calcium carbonate crystallization and presents two possible binding sites where the nucleation may be initiated, either calcium ions acting as counterions of the polyelectrolyte or those trapped in the template gel network formed by the polyelectrolyte chains. Calcium carbonate formation was carried out by carbon dioxide diffusion, where CO, was generated from ammonium carbonate decomposition. The CaCO3 nanocrystals obtained, formed a dense, homogeneous, and continuous film. Vaterite and calcite CaCO3 crystalline forms were detected. (c) 2007 Elsevier B.V All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive, selective, and reproducible in-tube solid-phase microextraction and liquid chromatographic (in-tube SPME/LC-UV) method for simultaneous determination of mirrazapine, citalopram, paroxetine, duloxetine, fluoxetine, and sertraline in human plasma was developed, validated and further applied to the analysis of plasma samples from elderly patients undergoing therapy with antidepressants. Important factors in the optimization of in-tube SPME efficiency are discussed, including the sample draw/eject volume, draw/eject cycle number, draw/eject flow-rate, sample pH, and influence of plasma proteins. The quantification limits of the in-tube SPME/LC method varied between 20 and 50 ng/mL, with a coefficient of variation lower than 10%. The response of the in-tube SPME/LC method for most of the drugs was linear over a dynamic range from 50 to 500 ng/mL, with correlation coefficients higher than 0.9985. The in-tube SPME/LC can be successfully used to analyze plasma samples from ageing patients undergoing therapy with nontricyclic antidepressants. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Techniques applying digital images increasingly have been used in biology, medicine, physics, and other research areas. The image coordinates can represent light intensities values to be detected by a CCD. Based on this concept, a photometric system composed of a LED source and a digital camera as a detector was used for optical density measurements. Standards for permanganate, glucose, and protein solutions were detemined by colorimetric methods using our device. Samples of protein of Pasteurella mutocida bacteria membrane and, also, fractions of rabbit kidney membrane, rich in Na, K-ATPase, with unknown concentrations were dosed through the Hartree method using our photometric system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive and reproducible method by microextraction packed sorbent and liquid chromatography with UV detection (MEPS/LC-UV) is described for the determination of new generation antidepressants (sertraline, mirtazapine, fluoxetine, citalopram and paroxetine) in human plasma samples. The MEPS variables, such as sample volume, pH, number of extraction cycles (draw-eject), and desorption conditions (solvent and solvent volume of elution) influenced the MEPS/LC efficiency significantly. Important factors in the optimization of MEPS efficiency, as well as washing steps and carryover effect are discussed. The analyses were carried out using small sample volumes (400 mu L.), and in a short time period (3 min for the entire sample preparation step). The MEPS/LC-UV method was shown to be linear at concentrations ranging from the limit of quantification (LOQ) to 1000 ng mL(-1). The LOQ values ranged from 10 to 25 ng mL(-1). The inter-day precision of the method presented coefficient of the variation ranging from 1.3% to 8.7%. On the basis of analytical validation, it is shown that the MEPS/LC-UV methodology is adequate for antidepressant analysis, from therapeutic to toxic levels. In order to evaluate the proposed method for clinical use, the MEPS/LC-UV method was applied to analysis of plasma samples from elderly depressed patients. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive and precise stir bar sorptive extraction (SBSE) combined with LC (SBSE/LC) analysis is described for simultaneous determination of methyl, ethyl, propyl, and butyl parabens in commercial cosmetic products in agreement with the European Union Cosmetics Directive 76/768/EEC. Important factors in the optimization of SB SE efficiency are discussed, such as time and temperature of extraction, pH, and ionic strength of the sample, matrix effects, and liquid desorption conditions by different modes (magnetic stirring, ultrasonic). The LOQs of the SBSE/LC method ranged from 30 to 200 ng/mg, with linear response over a dynamic range, from the LOQ to 2.5 mu g/mg, with a coefficient of determination higher than 0.993. The interday precision of the SBSE/LC method presented a coefficient of variation lower than 5%. The effectiveness of the proposed method was proven for analysis of commercial cosmetic products such as body creams, antiperspirant creams, and sunscreens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

2D DOSY (1)H NMR has proved to be a useful technique in the identification of the molecular skeleton of the four major compounds of ethyl acetate extract of aerial parts of Bidens sulphurea (Asteraceae). The combination of this technique with HPLC, mass spectrometry and other NMR techniques enabled the identification of four flavonoid glycosides: quercetin-3-O-beta-D-galactopyranoside, quercetin-3-O-beta-D-glycopyranoside, quercetin-3-O-alpha-L-arabinofuranoside and quercetin-3-O-beta-D-rhamnopyranoside. Copyright (C) 2009 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The title compound, C(8)H(14)N(2)O(5)S 2(H(2)O), 2-amino-3-(N-oxipiridin-4-ilsulfanil)-propionic acid dihydrate, is obtained by the reaction of cysteine and 4-nitropyridine N-oxide in dimethylformamide, removing the NO(2) group from the benzene ring and releasing nitrous acid into the solution. The molecule exists as a Zwitterion. Hydrogen bond interactions involving the title molecule and water molecules allow the formation of R(5)(5)(23) edge fused rings parallel to (010). Water molecules are connected independently, forming infinite chains (wires), in square wave form, along the b-axis. The chirality of the cysteine molecule used in the synthesis is retained in the title molecule. A density functional theory (DFT) optimized structure at the B3LYP/6-311G(3df,2p) level allows comparison of calculated and experimental IR spectra.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gasteruptiinae is the largest Gasteruptiidae subfamily, with circa 400 species that have been grouped into the worldwide Gasteruption Latreille. Based on a cladistic analysis with 43 morphological characters, 40 ingroup taxa representing all biogeographic regions, and seven outgroups (four Hyptiogastrinae, two Aulacidae and one Evaniidae), I confirm the monophyly of Gasteruptiinae and Gasteruption and recognize three exclusively Neotropical small genera: Plutofoenus Kieffer (revalidated) (southern South America), Spinolafoenus Macedo n. gen. (Chile) and Trilobitofoenus Macedo n. gen. (Central and South America). Gasteruption, supported by four synapomorphies, remains the most speciose genus in the subfamily. The four Gasteruptiinae genera are keyed and described. Seven species are keyed and described or redescribed: Plutofoenus chaeturus (Schletterer) n. comb., P. edwardsi Turner, P. paraguayensis (Schrottky), Spinolafoenus ruficornis (Spinola) n. comb., Trilobitofoenus alvarengai Macedo n. sp., T. plaumanni Macedo n. sp. and T. sericeus (Cameron) n. comb. (lectotype designated).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To describe homicide mortality in the municipality of Sao Paulo according to type of weapon, sex, race or skin color, age, and areas of socioeconomic inequalities, between 1996 and 2008. Method. For this ecological time-series study, data about deaths in the municipality of Sao Paulo were collected from the municipal program for improvement of mortality information, using International Classification of Diseases, 10th revision (ICD-10) codes. Homicide mortality rates (HMR) were calculated for the overall population and specifically for each sex, race or skin color, age range, type of weapon, and occurrence in social deprivation/affluence areas. HMR were adjusted for age using the direct method. The percentage age of variation in HMR was calculated for the study period. For areas of socioeconomic inequalities, the relative risk of death from homicide was calculated. Results. HMR fell 73.7% between 2001 and 2008. A reduction in HMR was observed in all groups, especially males (-74.5%), young men between 15 and 24 years of age (-78.0%), and residents in areas of extreme socioeconomic deprivation (-79.3%). The reduction occurred mostly in firearm homicide rates (-74.1%). The relative risk of death from homicide in areas of extreme socioeconomic deprivation, as compared to areas with some degree of socioeconomic deprivation, was 2.77 in 1996, 3.9 in 2001, and 2.13 in 2008. In areas of high socioeconomic deprivation, the relative risk was 2.07 in 1996 and 1.96 in 2008. Conclusions. To understand the reduction in homicide rates in the municipality of Sao Paulo, it is important to take into consideration macrodeterminants that affect the entire municipality and all population subgroups, as well as micro/local determinants that have special impact on homicides committed with firearms and on subgroups such as the young, males, and residents of areas of high socioeconomic deprivation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate wavefront performance and modulation transfer function (MTF) in the human eye aft er the implantation of diffractive or refractive multifocal intraocular lenses (IOLs). Materials and Methods: This was a prospective, interventional, comparative, nonrandomized clinical study. Uncorrected distance and near visual acuity, and wavefront analysis including MTF curves (iTrace aberrometer, Tracey Technologies, Houston, TX, USA) were measured in 60 patients aft er bilateral IOL implantation with 6 months of follow-up. Forty eyes received the diffractive ReSTOR (Alcon), 40 eyes received the refractive ReZoom (Advanced Medical Optics) and 40 eyes, the Tecnis ZM900 (Advanced Medical Optics). The comparison of MTF and aberration between the intraocular lenses was performed using analysis of variance (ANOVA), followed by the Dunn test when necessary. Results: The mean uncorrected distance visual acuity was similar in all three groups of multifocal IOLs. The ReSTOR group provided better uncorrected near visual acuity than the ReZoom group (P < 0.001), but similar to the Tecnis group. Spherical aberration was significantly higher in the ReZoom group (P = 0.007). Similar MTF curves were found for the aspheric multifocal IOL Tecnis and the spheric multifocal IOL ReSTOR, and both performed better than the multifocal IOL ReZoom in a 5 mm pupil (P < 0.001 at all spatial frequencies). Conclusions: Diffractive IOLs studied presented similar MTF curves for a 5 mm pupil diameter. Both diffractive IOLs showed similar spherical aberration, which was significantly better with the full-diffractive IOL Tecnis than with the refractive IOL ReZoom.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine whether implantation of an aspherical intraocular lens (IOL) results in reduced ocular aberrations and improved contrast sensitivity after cataract surgery without critical reduction of depth of focus. DESIGN: Double-blinded, randomized, prospective study. METHODS: In an intraindividual study of 25 patients with bilateral cataract, an aspherical IOL (Akreos Advanced Optic [AO]; Bausch & Lomb, Inc., Rochester, New York, USA) was implanted in one eye and a spherical IOL (Akreos Fit; Bausch & Lomb, Inc) in the fellow eye. Higher-order aberrations with a 5- and 6-mm pupil were measured with a dynamic retinoscopy aberrometer at 1 and 3 months after surgery. Uncorrected and best-corrected visual acuity and contrast sensitivity under mesopic and photopic conditions also were measured. Distance-corrected near and intermediate visual acuity were studied as a measurement of depth of focus. RESULTS: There was no statistically significant difference between eyes in uncorrected and best-corrected visual acuity at I and 3 months after surgery. There was a statistically significant between-group difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. The Akreos AO group obtained statistically significant lower values of higher-order aberrations and spherical aberration with 5- and 6-mm pupils compared with the Akreos Fit group (P < .05). There was no significant difference in distance-corrected near and intermediate visual acuity between both groups. CONCLUSIONS: Aspherical aberration-free Akreos AO IOL induced significantly less higher-order aberrations and spherical aberration than the Akreos Fit. Contrast sensitivity was better under mesopic conditions with the Akreos AO with similar results of depth of focus. (Am J Ophthalmol 2010;149:383-389. (C) 2010 by Elsevier Inc. All rights reserved.)