317 resultados para Flow function
Resumo:
Synthetic type II pyrethroids induce anxiety, immunosuppresion or, alternatively, immunostimulatory effects in laboratory animals. Macrophages and neutrophils are known to be key elements in cellular immune responses. The present study was designed to investigate the in vivo effects of cyhalothrin (1.0 and 3.0 mg/kg/once daily for 7 days) on macrophage and neutrophil activities, using a flow cytometry method. Results showed that cyhalothrin treatment decreased the percentage and intensity of phagocytosis performed by macrophages, but did not alter these parameters in neutrophils: and also decreased basal neutrophil oxidative burst and increased S. aureus-induced neutrophil oxidative burst, but did not alter these responses in macrophages. The present results are discussed in the light of a possible indirect action of cyhalothrin on macrophage and neutrophil activities via hypothalamic pituitary adrenal (HPA) axis activation. A possible direct effect of cyhalothrin on macrophage and neutrophil activities is also considered. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Maternal recognition of pregnancy in the cow requires successful signaling by the conceptus to block luteolysis. Conceptus Growth and function depend on an optimal uterine environment, regulated by luteal progesterone. The objective of this study was to test strategies to optimize luteal function, as well as prevent a dominant follicle from initiating luteolysis. Nelore (Bos taurus indicus) beef cows (n = 40) were submitted to a GnRH/PGF(2 alpha)/GnRH protocol. Cows that ovulated from a dominant ovarian follicle (ovulation = Day 0) were allocated to receive: no additional treatment (Gc; n = 7); 3000 IU of hCG on Day 5 (G(hCG); n = 5); 5 mg of estradiol-17 beta on Day 12 (G(E2); n = 6); or 3000 IU of hCG on Day 5 and 5 mg of estradiol-17 beta on Day 12 (G(hCG/E2); n = 5). Ultrasonographic imaging of the ovaries, assessment of plasma progesterone concentration, and detection of estrus were done daily from Day 5 to the day of subsequent ovulation. Treatment with hCG induced an accessory CL, increased CL volume, and plasma progesterone concentration throughout the luteal phase (P < 0.01). Estradiol-17 beta induced atresia and recruitment of a new wave of follicular growth; it eliminated a potentially estrogen-active, growing ovarian follicle within the critical period for maternal recognition of pregnancy, but it also hastened luteolysis (Days 16 or 17 vs. Days 18 or 19 in non-treated cows). In conclusion, the approaches tested enhanced luteal function (hCG) and altered ovarian follicular dynamics (estradiol-17 beta), but were unable to extend the life-span of the CL in Nelore cows. (c) 2008 Elsevier Inc. All rights reserved.
Resumo:
The process of cryopreservation impairs sperm cell function, potentially leading to a reduction in fertility. The objectives of the present study were to evaluate the effects that cryopreservation using two different extenders has on sperm motility and mitochondrial function, as well as on the integrity of plasma membranes, acrosomal membranes and chromatin, using practical and objective techniques. The focus of the present study was to identify correlations between alterations in sperm membranes and sperm motility in cryopreserved bovine spermatozoa. Seven ejaculates were collected from eight Simmental bulls (n = 56). After collection, semen volume and concentration were assessed for purposes of dilution. Sperm motility was evaluated subjectively and by computer-assisted semen analysis, morphological characteristics were evaluated by differential interference microscopy, the integrity of plasma and acrosomal membranes, as well as mitochondrial function, were determined using a combination of fluorescent probes containing fluorescein isothiocyanate-Pisum sativum agglutinin, propidium iodide or 5,5`,6,6`-tetrachloro-1,1`,3,3`-tetraethylbenzimidazolearbocyanine iodide. Chromatin integrity was evaluated using the acridine orange technique. The semen was subsequently divided into two aliquots and diluted with one of two extenders (Bioxcell(R) or Botu-Bov(R)), after which both were packaged in 0.5 mL straws and frozen using an automated system. Two straws of semen from each treatment were thawed, and the semen parameters were evaluated as described above. Cryopreservation of sperm reduced motility, damaging plasma and acrosomal membranes, as well as decreasing mitochondrial function. The Botu-Bov(R) extender was more effective in preserving sperm motility and membrane integrity than was the Bioxcell(R) extender. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
The bovine maternal epithelium is composed of cuboidal cells interspersed with low columnar cells having centrally located nuclei. Bovine trophoblast is composed of two cell types: mononuclear trophoblastic and giant trophoblastic cells that can have two or more nuclei. Number of apoptotic cells and proliferative cells are variable in both cell populations. This study compared tissue growth and apoptosis by flow cytometry in the cell population found at distinct placental regions (central region of placentomes, <= 1-cm microplacentomes and the interplacentomal region) between normal and cloned near-term bovine pregnancies. After a morphological comparison between regions and groups (controls vs. clones), a lesser proportion of diploid to tetraploid cells was observed in the central region of placentomes and in microplacentomes from cloned-derived pregnancies. In addition, cloned animals had a fewer apoptotic cells in the central region of the placentome and in interplacentomal region and a greater proliferative capacity in all regions (cells in G(2)/M) near term as opposed to control animals. These results may reveal the existence of a relationship between such changes in the proportions of uterine and trophoblastic epithelial cells at the end of pregnancy and normal placental function. This could be related to faulty placentation in early pregnancy, placental insufficiency during pregnancy or lack of placental and/or fetal maturation in late pregnancy, which may contribute to someof the abnormalities after in vitro embryo manipulations, such as poor preparation and initiation of parturition, prolonged gestation and lesser post-natal survival in some cloned animals. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
The hepatic effects of the anesthetic association zolazepam/tiletamine were investigated in dogs by analyzing the serum concentration of hepatic enzymes. Ten healthy dogs were divided into two groups of five, group I (GI) and group II (GII). The animals of GI received a single dose of 6,6 mg/kg of zolazepam/tiletamine, by intramuscular (IM) injection. GII dogs received 6,6 mg/kg of zolazepam/tiletamine by the IM route; after a period of 50 - 80 minutes the animals received two additional doses (3,3 mg/kg) by intravenous administration[SAH1]. The hepatic function were analyzed by monitoring the serum concentrations of alanine aminotransferase (ALT), aspartate aminotransferase (AST), alkaline phosphatase (ALP), and gamma-glutamyl-transferase (GGT). Four blood samples were collected in different moments during the analyses: M0, before the first application of the drug; and M1 to M4. M1 through M3 was collected with intervals of 20 minutes before M0, while M4 was obtained 24 hours after M1. The normality of the obtained results was analyzed by Kolmogorov-Smirnov Test; while the Tukey`s test compared the means, using a level of significance of 5% for both statistical analyses. The mean values of all enzymes evaluated were within normal limits for both experimental groups, without any significant statistical alteration being observed between and within these groups. These results demonstrated that the association of zolazepam/tiletamine at the dosage of 6.6 mg/kg, followed by two applications additional of 3.3 mg/kg resulted in elevation of the evaluated hepatic enzymes without exceeding the physiologic values. Additionally, a single application of 6.6 mg/kg of zolazepam/tiletamine by the intramuscular route resulted in lower values when compared to three applications.
Resumo:
Objective. To investigate whether poor response to controlled ovarian stimulation (COS) is due to a qualitative decline in ovarian function. Methods. This retrospective cohort study included 436 patients younger than 35-years old, undergoing COS for intracytoplasmic sperm injection (ICSI). Patients with four or fewer MII oocytes after COS (poor-responder group, PR, n = 52) were age-matched with normoresponder patients (NR, n = 364). Results. Although similar duration of stimulation (10.5 +/- 0.4 and 9.3 +/- 0.8 days; p = 0.1358), increased doses of gonadotrophins (2510 +/- 865 and 2253 +/- 572 IU; p = 0.0061) were used in the PR. The results show a increased chance of cycle ending of PR (PR: 26.9% and NR: 3.1%; p < 0.0001). Although the lower total number of oocytes retrieved (2.4 +/- 1.4 and 16.2 +/- 9.3; p < 0.0001), equal rate of fertilization (70.2% and 72.0%, p = 0.1190) and high quality embryos were obtained (50.0% and 45.2%; p = 0.4895), resulting in similar implantation (14.5% and 19.7%; p = 0.2246) and abortion (10.0% and 15.4%; p = 1.00) rates, respectively. A trend towards increased pregnancy rate per embryo transfer in NR group was noted (PR: 26.3% and NR: 42.2%; p = 0.0818). Conclusions. Low ovarian response could be associated mainly with a quantitative rather than a qualitative decline in ovarian function. Therefore, even if the ovarian response to stimulation is low, patients aged <= 35 years should process to oocyte retrieval.
Resumo:
This study aims to investigate whether infrared diode low-level laser therapy (LLLT) increased salivary flow rate and altered pH value, protein concentration, and peroxidase and amylase activities in saliva of rats. Wistar rats were used and divided into three groups. Experimental groups (A and 13) had their parotid, submandibular and sublingual glands submitted to diode laser, 808-nm wavelength, on two consecutive days. The dose results were 4 and 8 J/cm(2), respectively. A red guide light was used to visualize the irradiated area. Group C was irradiated only with red pilot beam and served as control. The saliva samples were collected after each irradiation step (first and second collection days) and 1 week after the first irradiation (seventh day). Statistical analysis was performed, and differences were observed according to different days of salivary collection. The results showed that salivary flow rate for groups A and B was higher on the seventh day if it is compared to data obtained for the first day (p<0.05). LLLT applications on salivary glands are a therapy procedure that requires further studies.
Resumo:
Hyperglycemia induces overproduction of superoxide and it is related to diabetic complications. In this study, we analyzed the antioxidant enzymatic defense and the lipid peroxidation of rat salivary glands in six different periods of diabetic condition. Ninety-six rats were divided into 12 groups: C7/14/21128/45/60 (non-diabetic animals) and D7/14/21/28/45/60 (diabetic animals). Diabetes was induced by streptozotocin and the rats were euthanized after 7, 14, 21, 28, 45, or 60 days. Their parotid (PA) and submandibular (SM) glands were removed soon after the sacrifice and the total protein and malondialdehyde (MDA) concentrations, as well as, the superoxide dismutase (SOD), glutathione peroxidase (GPx), and catalase (CAT) activities were determined. Twenty-one days after the diabetes induction, the SM glands showed an increase in SOD, CAT, and GPx activities, as well as, MDA concentration. Concerning the PA glands, an increase in the CAT activity and MDA content was observed throughout the observation period. The results suggest that diabetes can cause alterations on the salivary glands and that PA and SM glands react differently when exposed to diabetes condition. However, no impairment of antioxidant system was observed in the group whose diabetic condition had been induced 60 days earlier, herein named 60-day group. Copyright (C) 2010 John Wiley & Sons, Ltd.
Resumo:
Objectives. To assess the elastic modulus (EM), volumetric shrinkage (VS), and polymerization shrinkage stress (PSS) of experimental highly filled nanohybrid composites as a function of matrix composition, filler distribution, and density. Methods. One regular viscosity nanohybrid composite (Grandio, VOCO, Germany) and one flowable nanohybrid composite (Grandio Flow, VOCO) were tested as references along with six highly filled experimental nanohybrid composites (four Bis-GMA-based, one UDMA-based, and one Ormocer (R) -based). The experimental composites varied in filler size and density. EM values were obtained from the ""three-point bending"" load-displacement curve. VS was calculated with Archimedes` buoyancy principle. PSS was determined in 1-mm thick specimens placed between two (poly) methyl methacrylate rods (empty set = 6 mm) attached to an universal testing machine. Data were analyzed using oneway ANOVA, Tukey`s test (alpha = 0.05), and linear regression analyses. Results. The flowable composite exhibited the highest VS and PSS but lowest EM. The PSS was significantly lower with Ormocer. The EM was significantly higher among experimental composites with highest filler levels. No significant differences were found between all other experimental composites regarding VS and PSS. Filler density and size did not influence EM, VS, or PSS. Significance. Neither the filler configuration nor matrix composition in the investigated materials significantly influenced composite shrinkage and mechanical properties. The highest filled experimental composite seemed to increase EM by keeping VS and PSS low; however, matrix composition seemed to be the determinant factor for shrinkage and stress development. The Ormocer, with reduced PSS, deserves further investigation. Filler size and density did not influence the tested parameters. (C) 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Objectives. Evaluate the effect of testing system compliance on polymerization stress and stress distribution of composites. Methods. Composites tested were Filtek Z250 (FZ), Herculite (HL), Tetric Ceram (TC), Helio Fill-AP (HF) and Heliomolar (HM). Stress was determined in 1-mm thick specimens, inserted between two rods of either poly(methyl methacrylate), PMMA, or glass. Experimental nominal stress (sigma(exp)) was calculated by dividing the maximum force recorded 5 min after photoactivation by the cross-sectional area of the rod. Composites` elastic modulus (E) was obtained by three-point bending. Data were submitted to one-way ANOVA/Tukey`s test (alpha = 0.05). Stress distribution on longitudinal (sigma(y)) and transverse (sigma(x)) axes of models representing the composites with the highest and lowest E (FZ and HM, respectively) were evaluated by finite element analysis (FEA). Results. sigma(exp) ranged from 5.5 to 8.8 MPa in glass and from 2.6 to 3.4 MPa in PMMA. Composite ranking was not identical in both substrates, since FZ showed or sigma(exp) statistically higher than HM in glass, while in PMMA FZ showed values similar to the other composites. A strong correlation was found between stress reduction (%) from glass to PMMA and composite`s E (r(2) = 0.946). FEA revealed that system compliance was influenced by the composite (FZ led to higher compliance than HM). sigma(x) distribution was similar in both substrates, while cry distribution showed larger areas of compressive stresses in specimens built on PMMA. Significance. sigma(exp) determined in PMMA was 53-68% lower than in glass. Composite ranking varied slightly due to differences in substrates` longitudinal and transverse deformation. (c) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Objective: Verify the influence of radiant exposure (H) on composite degree of conversion (DC) and mechanical properties. Methods: Composite was photoactivated with 3, 6, 12, 24, or 48 J/cm(2). Properties were measured after 48-h dry storage at room temperature. DC was determined on the flat surfaces of 6 mm x 2 mm disk-shaped specimens using FTIR. Flexural strength (FS) and modulus (FM) were accessed by three-point bending. Knoop microhardness number (KHN) was measured on fragments of FS specimens. Data were analyzed by one-way ANOVA/Tukey test, Student`s t-test, and regression analysis. Results: DC/top between 6 and 12 J/cm(2) and between 24 and 48 J/cm(2) were not statistically different. No differences between DC/top and bottom were detected. DC/bottom, FM, and KHN/top showed significant differences among all H levels. FS did not vary between 12 and 24 J/cm(2) and between 24 and 48 J/cm(2). KHN/bottom at 3 and 6 J/cm(2) was similar. KHN between top and bottom was different up to 12 J/cm(2). Regression analyses having H as independent variable showed a plateau region above 24 J/cm(2). KHN increased exponentially (top) or linearly (bottom) with DC. FS and FM increased almost linearly with DC/bottom up to 55% conversion. Conclusions: DC and mechanical properties increased with radiant exposure. Variables leveled off at high H levels. (C) 2007 Wiley Periodicals, Inc.
Resumo:
During orthodontic tooth movement, there is local production of chemokines and an influx of leukocytes into the periodontium. CCL5 plays an important role in osteoclast recruitment and activation. This study aimed to investigate whether the CCR5-receptor influences these events and, consequently, orthodontic tooth movement. An orthodontic appliance was placed in wild-type mice (WT) and CCR5-deficient mice (CCR5(-/-)). The expression of mediators involved in bone remodeling was evaluated in periodontal tissues by Real-time PCR. The number of TRAP-positive osteoclasts and the expression of cathepsin K, RANKL, and MMP13 were significantly higher in CCR5(-/-). Meanwhile, the expression of two osteoblastic differentiation markers, RUNX2 and osteocalcin, and that of bone resorption regulators, IL-10 and OPG, were lower in CCR5(-/-). Analysis of the data also showed that CCR5(-/-) exhibited a greater amount of tooth movement after 7 days of mechanical loading. The results suggested that CCR5 might be a down-regulator of alveolar bone resorption during orthodontic movement.
Resumo:
Objective. The aim of this study was to evaluate the flow rate of 3 endodontic sealers: Sealer 26, AH Plus, and MTA Obtura. Study design. According to the method proposed by the American Dental Association (ADA specification no. 57), the sealers were placed between 2 glass slabs under a weight of 120 g. The diameters of the formed discs were measured with a digital paquimeter. The test was repeated 5 times for each sealer. Results. The results were expressed as arithmetic means, and the statistical analysis was performed through Tukey test. AH Plus showed significantly superior flow rate compared with Sealer 26 and MTA Obtura. There was no statistically significant difference between flow rates presented by Sealer 26 and MTA Obtura. Conclusion. Within the limitations of this in vitro study, it was concluded that all of the the endodontic sealers tested presented greater flow than the minimum recommended in the ADA 57 specification. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010;109:e47-e49)
Resumo:
Objectives. To evaluate the influence of different tertiary amines on degree of conversion (DC), shrinkage-strain, shrinkage-strain rate, Knoop microhardness, and color and transmittance stabilities of experimental resins containing BisGMA/TEGDMA (3: 1 wt), 0.25wt% camphorquinone, 1wt% amine (DMAEMA, CEMA, DMPT, DEPT or DABE). Different light-curing protocols were also evaluated. Methods. DC was evaluated with FTIR-ATR and shrinkage-strain with the bonded-disk method. Shrinkage-strain-rate data were obtained from numerical differentiation of shrinkage-strain data with respect to time. Color stability and transmittance were evaluated after different periods of artificial aging, according to ISO 7491: 2000. Results were evaluated with ANOVA, Tukey, and Dunnett`s T3 tests (alpha = 0.05). Results. Studied properties were influenced by amines. DC and shrinkage-strain were maximum at the sequence: CQ < DEPT < DMPT <= CEMA approximate to DABE < DMAEMA. Both DC and shrinkage were also influenced by the curing protocol, with positive correlations between DC and shrinkage-strain and DC and shrinkage-strain rate. Materials generally decreased in L* and increased in b*. The strong exception was the resin containing DMAEMA that did not show dark and yellow shifts. Color varied in the sequence: DMAEMA < DEPT < DMPT < CEMA < DABE. Transmittance varied in the sequence: DEPT approximate to DABE < DABE approximate to DMPT approximate to CEMA < DMPT approximate to CEMA approximate to DMAEMA, being more evident at the wavelength of 400 nm. No correlations between DC and optical properties were observed. Significance. The resin containing DMAEMA showed higher DC, shrinkage-strain, shrinkage-strain rate, and microhardness, in addition to better optical properties. (C) 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
The extraction of teeth involves the elimination of extremely sensitive periodontal mechanoreceptors, which play an important role in oral sensory perception. Objectives: The aim of this study was to evaluate the recovery of interocclusal sensory perception for micro-thickness in individuals with different types of implant-supported prostheses. Materials and Methods: Wearers of complete dentures (CDs) comprised the negative control group (group A, n=17). The experimental group consisted of wearers of prostheses supported by osseointegrated implants (Group B, n=29), which was subsequently divided into 4 subgroups: B(1) (n=5) - implant supported overdentures (ISO) occluding with CD; B(2) (n=6) - implant-supported fixed prostheses (ISFP) occluding with CD; B3 (n=8) - wearers of maxillary and mandibular ISFP, and B(4) (n=10) - ISFP occluding with natural dentition (ND). Individuals with ND represented the positive control group (Group C, n=24). Aluminum foils measuring 10 mu m, 24 mu m, 30 mu m, 50 mu m, 80 mu m, and 104 mu m thickness were placed within the premolar area, adding up to 120 tests for each individual. Results: The mean tactile thresholds of groups A, B(1), B(2), B(3), B(4), and C were 92 mu m, 27 mu m, 27 mu m, 14 mu m, 10 mu m, and 10 mu m, respectively. [Correction added after publication online 18 April 2008: in the preceding sentence 92 mu m, 27 mu m, 14 mu m, 10 mu m and 10 mu m, was corrected to 92 mu m, 27 mu m, 27 mu m, 14 mu m, 10 mu m and 10 mu m.] The Kruskal-Wallis test revealed significant difference among groups (P < 0.05). The Dunn test revealed that group A was statistically different from groups C, B(3), and B(4), and that B(1) and B(2) were statistically different from group C. Conclusion: Progressive recovery of osseoperception as a function of the combination of implant-supported prostheses could be observed. Moreover, ISO and/or ISFP combinations may similarly maximize the recovery of osseoperception.