17 resultados para neutron detector
Resumo:
An all-in-one version of a capacitively coupled contactless conductivity detector is introduced. The absence of moving parts (potentiometers and connectors) makes it compact (6.5 cm(3)) and robust. A local oscillator, working at 1.1 MHz, was optimized to use capillaries of id from 20 to 100 lam. Low noise circuitry and a high-resolution analog-to-digital converter (ADC) (21 bits effective) grant good sensitivities for capillaries and background electrolytes currently used in capillary electrophoresis. The fixed frequency and amplitude of the signal generator is a drawback that is compensated by the steady calibration curves for conductivity. Another advantage is the possibility of determining the inner diameter of a capillary by reading the ADC when air and subsequently water flow through the capillary. The difference of ADC reading may be converted into the inner diameter by a calibration curve. This feature is granted by the 21-bit ADC, which eliminates the necessity of baseline compensation by hardware. In a typical application, the limits of detection based on the 3 sigma criterion (without baseline filtering) were 0.6, 0.4, 0.3, 0.5, 0.6, and 0.8 mu mol/L for K(+), Ba(2+), Ca(2+), Na(+), Mg(2+), and Li(+), respectively, which is comparable to other high-quality implementations of a capacitively coupled contactless conductivity detector.
Resumo:
A new compact system encompassing in flow gas diffusion unit and a wall-jet amperometric FIA detector, coated with a supramolecular porphyrin film, was specially designed as an alternative to the time-consuming Monier-Williams method, allowing fast, reproducible and accurate analyses of free sulphite species in fruit juices. In fact, a linear response between 0.64 and 6.4 ppm of sodium sulphite. LOD = 0.043 ppm, relative standard deviation of +/- 1.5% (n = 10) and analytical frequency of 85 analyses/h were obtained utilising optimised conditions. That superior analytical performance allows the precise evaluation of the amount of free sulphite present in foods, providing an important comparison between the standard addition and the standard injection methods. Although the first one is most frequently used, it was strongly influenced by matrix effects because of the unexpected reactivity of sulphite ions with the juice matrixes, leading to its partial consumption soon after addition. In contrast, the last method was not susceptible to matrix effects yielding accurate results, being more reliable for analytical purposes. (C) 2011 Elsevier Ltd. All rights reserved.