158 resultados para Size-disparity correlation


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The stratigraphic subdivision and correlation of dune deposits is difficult, especially when age datings are not available. A better understanding of the controls on texture and composition of eolian sands is necessary to interpret ancient eolian sediments. The Imbituba-Jaguaruna coastal zone (Southern Brazil, 28 degrees-29 degrees S) stands out due to its four well-preserved Late Pleistocene (eolian generation 1) to Holocene eolian units (eolian generations 2, 3, and 4). In this study, we evaluate the grain-size and heavy-mineral characteristics of the Imbituba-Jaguartma eolian units through statistical analysis of hundreds of sediment samples. Grain-size parameters and heavy-mineral content allow us to distinguish the Pleistocene from the Holocene units. The grain size displays a pattern of fining and better sorting from generation 1 (older) to 4 (younger), whereas the content of mechanically stable (dense and hard) heavy minerals decreases from eolian generation 1 to 4. The variation in grain size and heavy-mineral content records shifts in the origin and balance (input versus output) of eolian sediment supply attributable mainly to relative sea-level changes. Dunefields submitted to relative sea-level lowstand conditions (eolian generation 1) are characterized by lower accumulation rates and intense post-depositional dissection by fluvial incision. Low accumulation rates favor deflation in the eolian system, which promotes concentration of denser and stable heavy minerals (increase of ZTR index) as well as coarsening of eolian sands. Dissection involves the selective removal of finer sediments and less dense heavy minerals to the coastal source area. Under a high rate of relative sea-level rise and transgression (eolian generation 2), coastal erosion prevents deflation through high input of sediments to the coastal eolian source. This condition favors dunefield growth. Coastal erosion feeds sand from local sources to the eolian system. including sands from previous dunefields (eolian generation 1) and from drowned incised valleys. Therefore, dunefields corresponding to transgressive phases inherit the grain-size and heavy-mineral characteristics of previous dunefields, leading to selective enrichment of finer sands and lighter minerals. Eolian generations 3 and 4 developed during a regressive-progradational phase (Holocene relative sea level highstand). The high rate of sediment supply during the highstand phase prevents deflation. The lack of coastal erosion favors sediment supply from distal sources (fluvial sediments rich in unstable heavy minerals). Thus, dunefields of transgressive and highstand systems tracts may be distinguished from dunefields of the lowstand systems tract through high rates of accumulation (low deflation) in the former. The sediment source of the transgressive dunefields (high input of previously deposited coastal sands) differs from that of the highstand dunefields (high input of fluvial distal sands). Based on this case study, we propose a general framework for the relation between relative sea level, sediment supply and the texture and mineralogy of eolian sediments deposited in siliciclastic wet coastal zones similar to the Imbituba-Jaguaruna coast (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: This study assessed the bone density gain and its relationship with the periodontal clinical parameters in a case series of a regenerative therapy procedure. MATERIAL AND METHODS: Using a split-mouth study design, 10 pairs of infrabony defects from 15 patients were treated with a pool of bovine bone morphogenetic proteins associated with collagen membrane (test sites) or collagen membrane only (control sites). The periodontal healing was clinically and radiographically monitored for six months. Standardized pre-surgical and 6-month postoperative radiographs were digitized for digital subtraction analysis, which showed relative bone density gain in both groups of 0.034 ± 0.423 and 0.105 ± 0.423 in the test and control group, respectively (p>0.05). RESULTS: As regards the area size of bone density change, the influence of the therapy was detected in 2.5 mm² in the test group and 2 mm² in the control group (p>0.05). Additionally, no correlation was observed between the favorable clinical results and the bone density gain measured by digital subtraction radiography (p>0.05). CONCLUSIONS: The findings of this study suggest that the clinical benefit of the regenerative therapy observed did not come with significant bone density gains. Long-term evaluation may lead to a different conclusions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microleakage can be related to margin misfit. Also, traditional microleakage techniques are time-consuming. This study evaluated the existence of correlation between in vitro margin fit and a new microleakage technique for complete crowns cemented with 3 different luting agents. Thirty human premolars were prepared for full-coverage crowns with a convergence angle of 6 degrees, chamfer margin of 1.2 mm circumferentially, and occlusal reduction of 1.5 mm. Ni-Cr cast crowns were cemented with either zinc phosphate (ZP) (S.S. White), resin-modified glass-ionomer (RMGI) (Rely X Luting Cement) or a resin-based luting agent (RC) (Enforce). Margin fit (seating discrepancy and margin gap) was evaluated according to criteria in the literature under microscope with 0.001 mm accuracy. After thermal cycling, crowns were longitudinally sectioned and microleakage scores at tooth-cement interface were obtained and recorded at ×100 magnification. Margin fit parameters were compared with the one-way ANOVA test and microleakage scores with Kruskal-Wallis and Dunn's tests (alpha=0.05). Correlation between margin fit and microleakage was analyzed with the Spearman's test (alpha=0.05). Seating discrepancy and marginal gap values ranged from 81.82 µm to 137.22 µm (p=0.117), and from 75.42 µm to 78.49 µm (p=0.940), respectively. Marginal microleakage scores were ZP=3.02, RMGI=0.35 and RC=0.12 (p<0.001), with no differences between RMGI and RC scores. The correlation coefficient values ranged from -0.27 to 0.30 (p>0.05). Conclusion: Margin fit parameters and microleakage showed no strong correlations; cast crowns cemented with RMGI and RC had lower microleakage scores than ZP cement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the metal-ceramic bond strength (MCBS) of 6 metal-ceramic pairs (2 Ni-Cr alloys and 1 Pd-Ag alloy with 2 dental ceramics) and correlate the MCBS values with the differences between the coefficients of linear thermal expansion (CTEs) of the metals and ceramics. Verabond (VB) Ni-Cr-Be alloy, Verabond II (VB2), Ni-Cr alloy, Pors-on 4 (P), Pd-Ag alloy, and IPS (I) and Duceram (D) ceramics were used for the MCBS test and dilatometric test. Forty-eight ceramic rings were built around metallic rods (3.0 mm in diameter and 70.0 mm in length) made from the evaluated alloys. The rods were subsequently embedded in gypsum cast in order to perform a tensile load test, which enabled calculating the CMBS. Five specimens (2.0 mm in diameter and 12.0 mm in length) of each material were made for the dilatometric test. The chromel-alumel thermocouple required for the test was welded into the metal test specimens and inserted into the ceramics. ANOVA and Tukey's test revealed significant differences (p=0.01) for the MCBS test results (MPa), with PI showing higher MCBS (67.72) than the other pairs, which did not present any significant differences. The CTE (10-6 oC-1) differences were: VBI (0.54), VBD (1.33), VB2I (-0.14), VB2D (0.63), PI (1.84) and PD (2.62). Pearson's correlation test (r=0.17) was performed to evaluate of correlation between MCBS and CTE differences. Within the limitations of this study and based on the obtained results, there was no correlation between MCBS and CTE differences for the evaluated metal-ceramic pairs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the influence of cervical preflaring with different rotary instruments on determination of the initial apical file (IAF) in mesiobuccal roots of mandibular molars. Fifty human mandibular molars whose mesial roots presented two clearly separated apical foramens (mesiobuccal and mesiolingual) were used. After standard access opening and removal of pulp tissue, the working length (WL) was determined at 1 mm short of the root apex. Five groups (n=10) were formed at random, according to the type of instrument used for cervical preflaring. In group 1, the size of the IAF was determined without preflaring of the cervical and middle root canal thirds. In groups 2 to 5, preflaring was performed with Gates-Glidden drills, ProTaper instruments, EndoFlare instruments and LA Axxes burs, respectively. Canals were sized manually with K-files, starting with size 08 K-files, inserted passively up to the WL. File sizes were increased until a binding sensation was felt at the WL and the size of the file was recorded. The instrument corresponding to the IAF was fixed into the canal at the WL with methylcyanoacrylate. The teeth were then sectioned transversally 1 mm short of the apex, with the IAF in position. Cross-sections of the WL region were examined under scanning electron microscopy and the discrepancies between canal diameter and the diameter of IAF were calculated using the tool "rule" (FEG) of the microscope's proprietary software. The measurements (µm) were analyzed statistically by Kruskal-Wallis and Dunn's tests at 5% significance level. There were statistically significant differences among the groups (p<0.05). The non-flared group had the greatest discrepancy (125.30 ± 51.54) and differed significantly from all flared groups (p<0.05). Cervical preflaring with LA Axxess burs produced the least discrepancies (55.10 ± 48.31), followed by EndoFlare instruments (68.20 ± 42.44), Gattes Glidden drills (68.90 ± 42.46) and ProTaper files (77.40 ± 73.19). However, no significant differences (p>0.05) were found among the rotary instruments. In conclusion, cervical preflaring improved IAF fitting to the canals at the WL in mesiobuccal roots of maxillary first molars. The rotary instruments evaluated in this study did not differ from each other regarding the discrepancies produced between the IAF size and canal diameter at the WL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the bone repair using autogenous periosteum-derived cells (PDC) and bovine anorganic apatite and collagen (HA-COL). PDC from Wistar rats (n=10) were seeded on HA-COL discs and subjected to osteoinduction during 6 days. Critical-size defects in rat calvarias were treated with blood clot (G1), autogenous bone (G2), HA-COL (G3) and HA-COL combined with PDC (G4) (n=40), and then analyzed 1 and 3 months after surgeries. Radiographic analysis exhibited no significant temporal change. G1 and G2 had discrete new marginal bone, but the radiopacity of graft materials in G2, G3 and G4 impaired the detection of osteogenesis. At 3 months, histopathological analysis showed the presence of ossification islets in G1, which was more evident in G2, homogeneous new bone around HA-COL in G3 and heterogeneous new bone around HA-COL in G4 in addition to moderate presence of foreign body cells in G3 and G4. Histomorphometric analysis showed no change in the volume density of xenograft (p>0.05) and bone volume density in G2 was twice greater than in G1 and G4 after 3 months (p<0.05), but similar to G3. The PDC did not increase bone formation in vivo, although the biomaterial alone showed biocompatibility and osteoconduction capacity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study compared the accuracy of three electronic apex locators (EALs) - Elements Diagnostic®, Root ZX® and Apex DSP® - in the presence of different irrigating solutions (0.9% saline solution and 1% sodium hypochlorite). The electronic measurements were carried out by three examiners, using twenty extracted human permanent maxillary central incisors. A size 10 K file was introduced into the root canals until reaching the 0.0 mark, and was subsequently retracted to the 1.0 mark. The gold standard (GS) measurement was obtained by combining visual and radiographic methods, and was set 1 mm short of the apical foramen. Electronic length values closer to the GS (± 0.5 mm) were considered as accurate measures. Intraclass correlation coefficients (ICCs) were used to verify inter-examiner agreement. The comparison among the EALs was performed using the McNemar and Kruskal-Wallis tests (p < 0.05). The ICCs were generally high, ranging from 0.8859 to 0.9657. Similar results were observed for the percentage of electronic measurements closer to the GS obtained with the Elements Diagnostic® and the Root ZX® EALs (p > 0.05), independent of the irrigating solutions used. The measurements taken with these two EALs were more accurate than those taken with Apex DSP®, regardless of the irrigating solution used (p < 0.05). It was concluded that Elements Diagnostic® and Root ZX® apex locators are able to locate the cementum-dentine junction more precisely than Apex DSP®. The presence of irrigating solutions does not interfere with the performance of the EALs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The parasitic protozoan Leishmania (Leishmania) amazonensis alternates between mammalian and insect hosts. In the insect host, the parasites proliferate as procyclic promastigotes andthen differentiate into metacyclic infective forms. The meta 1 gene is preferentially expressed during metacyclogenesis. Meta 1 expression profile determination along parasite growth curves revealed that the meta 1 mRNA level peaked at the early stationary phase then decreased to an intermediate level. No correlation was observed between meta 1 expression and infectivity. Conversely, infectivity correlated with the increase of apoptotic cells in the late stationary phase.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Rett syndrome (RS) is a severe neurodevelopmental X-linked dominant disorder caused by mutations in the MECP2 gene. PURPOSE: To search for point mutations on the MECP2 gene and to establish a correlation between the main point mutations found and the phenotype. METHOD: Clinical evaluation of 105 patients, following a standard protocol. Detection of point mutations on the MECP2 gene was performed on peripheral blood DNA by sequencing the coding region of the gene. RESULTS: Classical RS was seen in 68% of the patients. Pathogenic point mutations were found in 64.1% of all patients and in 70.42% of those with the classical phenotype. Four new sequence variations were found, and their nature suggests patogenicity. Genotype-phenotype correlations were performed. CONCLUSION: Detailed clinical descriptions and identification of the underlying genetic alterations of this Brazilian RS population add to our knowledge of genotype/phenotype correlations, guiding the implementation of mutation searching programs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Development of the positive temperature coefficient of resistivity (PTCR) in Er3+ and Ca2+ co-doped ferroelectric BaTiO3 was studied in this work, with Er3+ being used to act as a donor doping. Irrespective of all the materials showing high densities after sintering at 1200 to 1300 ºC, these revealed insulator at the lowest sintering temperature, changing to semiconducting and PTCR-type materials only when the sintering temperature was further increased. Observations from X-ray diffraction help correlating this effect with phase development in this formulated (Ba,Ca,Er)TiO3 system, considering the formation of initially two separated major (Ba,Ca)TiO3- and minor (Ca,Er)TiO3-based compounds, as a consequence of cation size-induced stress energy effects. Thus, appearance and enhancement here of the semiconducting and PTCR responses towards higher sintering temperatures particularly involve the incorporation of Er3+ into the major phase, rendering finally possible the generation and "percolative-like" migration of electrons throughout the whole material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Memantine is an N-methyl-d-aspartate (NMDA) glutamate receptor antagonist used to treat Alzheimer's disease. Previous studies have suggested that receptor blockers act as neuroprotective agents; however, no study has specifically investigated the impact that these drugs have on the heart. We sought to evaluate the effects of memantine on nuclear size reduction in cardiac cells exposed to cold stress. METHOD: We used male EPM-Wistar rats (n=40) divided into 4 groups: 1) Matched control (CON); 2) Memantine-treated rats (MEM); 3) Rats undergoing induced hypothermia (IH) and 4) Rats undergoing induced hypothermia that were also treated with memantine (IHM). Animals in the MEM and IHM groups were treated by oral gavage administration of 20 mg/kg/day memantine over an eight-day period. Animals in the IH and IHM groups were submitted to 4 hours of hypothermia in a controlled environment with a temperature of - 8ºC on the last day of the study. RESULTS: The MEM group had the largest cardiomyocyte nuclear size (151 ± 3.5 μm³ vs. CON: 142 ± 2.3 μm³; p<0.05), while the IH group had the smallest mean value of nuclear size. The nuclear size of the IHM group was preserved (125 ± 2.9 μm³) compared to the IH group (108 ± 1.7 μm³; p<0.05). CONCLUSION: Memantine prevented the nuclear size reduction of cardiomyocytes in rats exposed to cold stress.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Foram comparados dois métodos não-invasivos de medida da pressão arterial, o Doppler vascular e o oscilométrico, com o objetivo de estabelecer parâmetros que possam auxiliar no diagnóstico seguro da hipertensão arterial. Para tal, foram utilizados 45 cães, machos e fêmeas, distribuídos em três grupos de acordo com o peso, pequeno, médio e grande porte. Em cada animal, procedeu-se a mensuração por meio do Doppler vascular e, em seguida, do oscilométrico. Na obtenção da pressão arterial sistólica, não houve diferença entre os métodos nos três grupos de animais, porém, na obtenção da pressão arterial diastólica, houve diferença estatística entre o Doppler vascular e o oscilométrico nos grupos de animais de pequeno e médio porte. Pôde-se concluir que valores confiáveis de pressão sistólica podem ser obtidos tanto por meio do Doppler vascular quanto do oscilométrico. Os valores da pressão arterial diastólica obtidos pelos dois métodos não se correlacionam, principalmente nos animais de pequeno e médio porte.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O conhecimento da variabilidade espacial dos atributos de um solo sob diferentes coberturas auxilia o estudo das alterações ocorridas em razão do manejo. O objetivo deste trabalho foi determinar, com uso da estatística clássica e geoestatística, a variabilidade espacial das frações texturais de um solo cultivado com pastagem e vegetação nativa. Amostras de solo foram coletadas na profundidade de 0-0,20m, nos pontos de cruzamento de uma malha, com intervalos regulares de 10m, totalizando 64 pontos em cada área. Na área de pastagem, as frações areia grossa e total apresentaram valores médios maiores em relação à vegetação nativa e correlações negativas com as altitudes dos pontos amostrais nas duas áreas. Todas as frações texturais apresentaram dependência espacial de moderada a alta nas duas áreas e com o patamar definido, com exceção da areia fina e do silte na pastagem. Grande parte dessa variabilidade ocorre em função da erosão hídrica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar se o conteúdo de auto-anticorpos anti-LDL oxidada (anti-LDLox) no plasma de adolescentes correlaciona-se com suas medidas antropométricas e com o perfil lipídico. MÉTODOS: O estudo incluiu 150 adolescentes com idade entre 10 e 15 anos, recrutados do ambulatório de obesidade da Universidade Federal de São Paulo (SP) e de escolas públicas de Piracicaba (SP). Foram avaliadas medidas antropométricas, como índice de massa corporal, circunferência de cintura e do braço, classificando os adolescentes em eutrófico, sobrepeso e obeso. Para as análises bioquímicas, foi realizado o perfil lipídico através de métodos enzimáticos colorimétricos, e para detecção do conteúdo de auto-anticorpos anti-LDLox, utilizou-se o método de ELISA. RESULTADOS: Segundo análises das variáveis antropométricas, o grupo obeso apresentou perfil alterado em relação aos grupos eutrófico e sobrepeso (p < 0,01), indicando risco cardiovascular. Quando o perfil lipídico foi avaliado, observaram-se diferenças estatisticamente significativas para as concentrações de colesterol total (p = 0,011), HDL-colesterol (p = 0,001) e LDL-colesterol (p < 0,042) nos grupos eutrófico e obeso. Para as análises de auto-anticorpos anti-LDLox plasmática, os grupos sobrepeso (p = 0,012) e obeso (p < 0,001) apresentaram valores superiores ao grupo eutrófico. Também houve correlações entre os auto-anticorpos anti-LDLox e variáveis antropométricas. CONCLUSÃO: A presença de auto-anticorpos anti-LDLox em adolescentes e as alterações metabólicas no perfil lipídico variaram de modo proporcional com parâmetros antropométricos, o que torna o conteúdo de anti-LDLox um potencial indicador bioquímico de risco para síndrome metabólica