76 resultados para Intravascular ultrasound sequences
Resumo:
Sigma phase is a deleterious one which can be formed in duplex stainless steels during heat treatment or welding. Aiming to accompany this transformation, ferrite and sigma percentage and hardness were measured on samples of a UNS S31803 duplex stainless steel submitted to heat treatment. These results were compared to measurements obtained from ultrasound and eddy current techniques, i.e., velocity and impedance, respectively. Additionally, backscattered signals produced by wave propagation were acquired during ultrasonic inspection as well as magnetic Barkhausen noise during magnetic inspection. Both signal types were processed via a combination of detrended-fluctuation analysis (DFA) and principal component analysis (PCA). The techniques used were proven to be sensitive to changes in samples related to sigma phase formation due to heat treatment. Furthermore, there is an advantage using these methods since they are nondestructive. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
The therapeutic ultrasound (US) is one of the resources mostly used by physiotherapists; however the use of uncalibrated equipments results in inefficient or even harmful therapies to the patient. In this direction, the objective of this study was to evaluate the performance and the procedures of utilization and maintenance of US in use in clinics and Physical-therapy offices. A questionnaire with questions related to the procedures applied in service during the use of therapeutic ultrasound was applied to physiotherapists. The performance of 31 equipments of 6 different brands and 13 different models was evaluated according to the IEC 61689 norm. The parameters measured were: acoustic power; effective radiating area (AER); non-uniformity ratio of the beam (RBN); maximum effective intensity; acoustic frequency of operation, modulation factor and wave form on pulsate mode. As for the questionnaires, it was evident that the professionals are not concerned about the calibration of the equipment. The results demonstrated that only 32.3% of the equipments were in accordance with the norms for the variables power and effective radiation area. The frequency analysis indicated that 20% of the 3 MHz transducers and 12.5% of the 1 MHz contemplated the norms. In the pulsate mode, 12.7% presented relation rest/duration inside allowed limits. A great variation of the ultrasonic field was observed on the obtained images, which presented beams not centered, sometimes with bifurcation of its apex. The results allow concluding that, although used in therapeutic sessions with the population, none of the equipments presents all the analyzed variables inside technical norms. (C) 2010 Elsevier B. V. All rights reserved.
Resumo:
This work discusses the determination of the breathing patterns in time sequence of images obtained from magnetic resonance (MR) and their use in the temporal registration of coronal and sagittal images. The registration is made without the use of any triggering information and any special gas to enhance the contrast. The temporal sequences of images are acquired in free breathing. The real movement of the lung has never been seen directly, as it is totally dependent on its surrounding muscles and collapses without them. The visualization of the lung in motion is an actual topic of research in medicine. The lung movement is not periodic and it is susceptible to variations in the degree of respiration. Compared to computerized tomography (CT), MR imaging involves longer acquisition times and it is preferable because it does not involve radiation. As coronal and sagittal sequences of images are orthogonal to each other, their intersection corresponds to a segment in the three-dimensional space. The registration is based on the analysis of this intersection segment. A time sequence of this intersection segment can be stacked, defining a two-dimension spatio-temporal (2DST) image. The algorithm proposed in this work can detect asynchronous movements of the internal lung structures and lung surrounding organs. It is assumed that the diaphragmatic movement is the principal movement and all the lung structures move almost synchronously. The synchronization is performed through a pattern named respiratory function. This pattern is obtained by processing a 2DST image. An interval Hough transform algorithm searches for synchronized movements with the respiratory function. A greedy active contour algorithm adjusts small discrepancies originated by asynchronous movements in the respiratory patterns. The output is a set of respiratory patterns. Finally, the composition of coronal and sagittal image pairs that are in the same breathing phase is realized by comparing of respiratory patterns originated from diaphragmatic and upper boundary surfaces. When available, the respiratory patterns associated to lung internal structures are also used. The results of the proposed method are compared with the pixel-by-pixel comparison method. The proposed method increases the number of registered pairs representing composed images and allows an easy check of the breathing phase. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
The question raised by researchers in the field of mathematical biology regarding the existence of error-correcting codes in the structure of the DNA sequences is answered positively. It is shown, for the first time, that DNA sequences such as proteins, targeting sequences and internal sequences are identified as codewords of BCH codes over Galois fields.
Resumo:
The scaled-up preparation of 1H-pyrazole, 1-phenylpyrazole and isoxazole via sonocatalysis is reported. The products were isolated in good yields in short time reaction. These compounds had been assayed for antioxidant activity by ORAC and DPPH methodologies. The results showed that only 1-phenylpyrazole presented good antioxidant activity compared with Trolox(R).
Resumo:
An ultrasound-assisted synthesis of functionalized symmetrical biaryls with electron-withdrawing or electron-donating substituents is described and illustrated by the palladium-catalyzed detelluration of 1,2-diarylditellanes. This procedure offers easy access to symmetrical biaryls in short reaction time and the products are achieved in good to excellent yields. (c) 2009 Published by Elsevier Ltd.
Resumo:
An ultrasound-assisted synthesis of symmetrical biaryls with electron-withdrawing or -donating substituents is described and illustrated by palladium-catalyzed homocoupling reaction of aryl tellurides. This procedure offers easy access to biaryls in short reaction time, and the products are achieved in good to excellent yields.
Resumo:
In vitro skin permeation of hyaluronidase enzyme and the ultrasound (US) effects on cutaneous permeation of this enzyme were investigated. Diffusion cell technique, porcine skins, buffer solution, and a hydrophilic gel+hyaluronidase (100 TUR/g), were used for study. The experimental groups were: gel+enzyme and gel+enzyme+US. The activity of permeated hyaluronidase was determined by turbydimetric method in spectrophotometer at 400nm. Gel+enzyme group permitted a diffusion of 26.89 +/- 3.82 TUR of hyaluronidase in the total time of 240 minutes. However, the other group did not produce significant differences (p0.05) in the same period (13.68 +/- 5.35 TUR). Hyaluronidase permeation through the skin was verified; however US did not cause increase of this enzyme permeation.
Resumo:
An ultrasound-assisted synthesis of functionalized 1,3-enyne scaffolds is described and illustrated by palladium-catalyzed cross-coupling of potassium alkynyltrifluoroborate salts and alpha-styrylbutyltellurides. This procedure offers easy access to 1,3-enyne architecture that contains aliphatic and aromatic groups in good to excellent yields.
Resumo:
This paper describes a simple method for mercury speciation in seafood samples by LC-ICP-MS with a fast sample preparation procedure. Prior to analysis, mercury species were extracted from food samples with a solution containing mercaptoethanol, L-cysteine and HCl and sonication for 15 min. Separation of mercury species was accomplished in less than 5 min on a C8 reverse phase column with a mobile phase containing 0.05%-v/v mercaptoethanol, 0.4% m/v L-cysteine and 0.06 mol L(-1) ammonium acetate. The method detection limits were found to be 0.25, 0.20 and 0.1 ng g(-1) for inorganic mercury, ethylmercury and methylmercury, respectively. Method accuracy is traceable to Certified Reference Materials (DOLT-3 and DORM-3) from the National Research Council Canada (NRCC). With the proposed method there is a considerable reduction of the time of sample preparation. Finally, the method was applied for the speciation of mercury in seafood samples purchased from the Brazilian market. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
We have measured nucleotide variation in the CLOCK/CYCLE heterodimer inhibition domain (CCID) of the clock X-linked gene period in seven species belonging to the Drosophila buzzatii cluster, namely D. buzzatii, Drosophila koepferae, Drosophila antonietae, Drosophila serido, Drosophila gouveai, Drosophila seriema and Drosophila borborema. We detected that the purifying selection is the main force driving the sequence evolution in period, in agreement with the important role of CCID in clock machinery. Our survey revealed that period provides valuable phylogenetic information that allowed to resolve phylogenetic relationships among D. gouveai, D. borborema and D. seriema, which composed a polytomic clade in preliminary studies. The analysis of patterns of intraspecific variation revealed two different lineages of period in D. koepferae, probably reflecting introgressive hybridization from D. buzzatii, in concordance with previous molecular data.
Resumo:
Objective: To evaluate the impact of systematic use of intraoperative Doppler ultrasound during microsurgical subinguinal varicocele repair. Design: Prospective clinical study. Setting: Andrology laboratory and male infertility section of the urology department of a tertiary care hospital. Patient(s): Two hundred and thirteen men with clinical varicocele. Intervention(s): Subinguinal microsurgical varicocele ligation using an intraoperative vascular Doppler flow detector. Main Outcome Measure(s): Number of veins ligated, lymphatic spared, arteries identified or accidentally ligated. Result(s): A statistically significant greater number of arteries were identified and preserved when intraoperative vascular Doppler was used. In addition, the average number of internal spermatic veins ligated was statistically significantly greater in the same group. Accidental artery ligation occurred in two cases (1.1%) in which the Doppler was not applied. There was no statistically significant difference in number of lymphatics spared between groups. Conclusion(s): Our findings showed that concomitant use of intraoperative vascular Doppler during microsurgical varicocelectomy allows more arterial branches to be preserved, and more internal spermatic veins are likely to be ligated. This device should be considered an attractive tool to improve surgical outcomes and safety. (Fertil Steril (R) 2010; 93: 2396-9. (C)2010 by American Society for Reproductive Medicine.)
Resumo:
OBJECTIVE To evaluate the correlation between ultrasound-estimated bladder weight (UEBW) in patients with different degrees of bladder outlet obstruction (BOO). METHODS We evaluated 50 consecutive non-neurogenic male patients with lower urinary tract symptoms (LUTS) referred to urodynamic study (UDS). All patients self-answered the International Prostate Score Symptoms (IPSS) questionnaire. After the UDS, the bladder was filled with 150 mL to determine UEBW. Patients with a bladder capacity under 150 mL, a previous history of prostate surgery or pelvic irradiation, an IPSS score <8, a bladder stone or urinary tract infection were excluded. After a pressure-flow study, the Schafer linear passive urethral resistance relation nomogram was plotted to determine the grade of obstruction: Grades I-II/VI were defined as mild obstruction, Grades III-IV/VI as moderate obstruction, and Grades V-VI/VI as severe obstruction. RESULTS The UEBW was 51.7 +/- 26.9, 54.1 +/- 30.0 and 54.8 +/- 28.2 in patients with mild, moderate and severe BOO, respectively (P = 0.130). The UEBW allowed us to define four groups: (i) UEBW < 35 g; (ii) 35 g <= UEBW < 50 g; (iii) 50 g <= UEBW < 70 g; and (4) UEBW >= 70 g. We did not find any differences in age, prostate weight, IPSS, PVR, cystometric bladder capacity, presence of detrusor overactive and degree of obstruction in the aforementioned groups. CONCLUSION Despite the fact that some studies have emphasized the value of UEBW as an efficient non-invasive method for evaluating lower urinary tract obstruction, our study suggests that UEBW does not present any individual correlation with LUTS or objective measurements of BOO.
Resumo:
Catheter migration or catheter fracture and consequent migration of a fragment is a rare complication that occurs in 1% of the patients. Despite the low incidence, embolization may cause severe and potentially fatal complications, with the mortality rates varying between 24 and 60%. The gold standard treatment for this condition is the extraction of the fragmented catheter by the intravascular percutaneous route, through the common femoral vein. If it is not available, the extraction procedure must be performed through an alternative access. This article describes a fully successful removal of a fragmented catheter by percutaneous intravascular access obtained through the right subclavian vein.