184 resultados para Immunoassay, Assay validation, Accuracy, recision, Hyperinsulinemia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To validate a core set of outcome measures for the evaluation of response to treatment in patients with juvenile dermatomyositis (DM). Methods. In 2001, a preliminary consensus-derived core set for evaluating response to therapy in juvenile DM was established. In the present study, the core set was validated through an evidence-based, large-scale data collection that led to the enrollment of 294 patients from 36 countries. Consecutive patients with active disease were assessed at baseline and after 6 months. The validation procedures included assessment of feasibility, responsiveness, discriminant and construct ability, concordce in the evaluation of response to therapy between physicians and parents, redundancy, internal consistency, and ability to predict a therapeutic response. Results. The following clinical measures were found to be feasible, and to have good construct validity, discriminative ability, and internal consistency; furthermore, they were not redundant, proved responsive to clinically important changes in disease activity, and were associated strongly with treatment outcome and thus were included in the final core set: 1) physician`s global assessment of disease activity, 2) muscle strength, 3) global disease activity measure, 4) parent`s global assessment of patient`s well-being, 5) functional ability, and 6) health-related quality of life. Conclusion. The members of the Paediatric Rheumatology International Trials Organisation, with the endorsement of the American College of Rheumatology and the European Leauge Against Rheumatism, propose a core set of criteria for the evaluation of response of therapy that is scientifically and clinically relevant and statistically validated. The core set will help standardize the conduct and reporting of clinical trials and assist practitioners in deciding whether a child with juvenile DM has responded adequately to therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To investigate the accuracy of the Brazilian version of the Addenbrooke Cognitive Examination-revised (ACE-R) in the diagnosis of mild Alzheimer disease (AD). Background: The ACE-R is an accurate and brief cognitive battery for the detection of mild dementia, especially for the discrimination between AD and frontotemporal dementia. Methods: The battery was administered to 31 patients with mild AD and 62 age-matched and education-matched cognitively healthy controls. Both groups were selected using the Dementia Rating Scale and were submitted to the ACE-R. Depression was ruled out in both groups by the Cornell Scale for Depression in Dementia. The performance of patients and controls in the ACE-R was compared and receiver operator characteristic curve analysis was undertaken to ascertain the accuracy of the instrument for the diagnosis of mild AD. Results: The mean scores at the ACE-R were 63.10 +/- 10.22 points for patients with AD and 83.63 +/- 7.90 points for controls. The cut-off score < 78 yielded high diagnostic accuracy (receiver operator characteristic area under the curve = 0.947), with 100% sensitivity, 82.26% specificity, 73.8% positive predictive value, and 100% negative predictive value. Conclusions: The Brazilian version of the ACE-R displayed high diagnostic accuracy for the identification of mild AD in the studied sample.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quality of life (QOL) has been extensively studied in clinical trials and in research on chronic degenerative diseases and dementia. The aim of this study was to assess the reliability and construct validity of the Brazilian version of the QOL scale in Alzheimer`s disease (AD; QOL-AD). The QOL-AD was administered to 60 patients with mild or moderate AD and to their caregivers. The construct validation was accomplished through correlations amongst total scores of patients` and caregivers` reports on patients` quality of life (PQOL and C-PQOL, respectively), and data related to cognitive impairment, depressive symptoms, functional performance, behavioral disturbances and a generic instrument of quality of life (WHOQOL-brief), as well as correlation of total score of caregivers` reports on their own quality of life (CQOL) with the measurements cited above, QOL-AD patient reports, and depressive symptoms. The reliability was high for PQOL, C-PQOL, and CQOL versions (Cronbach`s alpha = 0.80, 0.83, and 0.86, respectively). We observed significant correlations in the construct validity of all three versions regarding the variables associated with the disease and also with WHOQOL-brief. The scale took, on average, six min for each version. The results indicate reliability and construct validity of the Brazilian version of the QOL-AD in the studied sample.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Labetalol is clinically available as a mixture of two racemates (four stereoisomers). The stereoisomer (R,R) has as main activity the beta(1)-antagonism and the stereoisomer (S,R) is highly selective for the alpha(1) adrenoceptor and is responsible for most of the alpha-blocker activity. In the present investigation, a method for the analysis of labetalol stereoisomers in human plasma was developed and applied to pharmacokinetic studies. Plasma samples (0.5 ml) were extracted with methyl tert-butyl ether at pH 9.5. The four labetalol stereoisomers were analyzed by LC-MS/MS on a Chirobiotic (R) V column using a mobile phase consisting of methanol, acetic acid, and diethylamine, with a recovery of more than 90% for all four. The quantitation limit was 0.5 ng/ml and linearity was observed at 250 ng/ml plasma for each stereoisomer. Studies of precision and accuracy presented coefficients of variation and percentage inaccuracy of less than 15%, indicating that the method is precise and accurate. The method was applied to the study of the kinetic disposition of labetalol over a period of 12 h after oral administration of a single 100 mg dose to a hypertensive pregnant woman. The clinical study revealed stereoselectivity in the pharmacokinetics of labetalol, with a lower plasma proportion for the active stereoisomers (R,R)-labetalol and (S,R)-labetalol. The stereoselectivity observed after oral administration is due to the hepatic metabolism and the first pass effect, with an AUC((R,R))/AUC((S,S)) ratio of 0.5. Chirality 21:738-744, 2009. (C) 2008 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this investigation was to assess the diagnostic accuracy of intraoperative cultures for the early identification of patients who are at risk of infection after primary total hip arthroplasty. Four or six swabs were obtained immediately before the wound closure in 263 primary total hip replacements. Patients with a maximum of one positive culture were denoted as patients with a normal profile and did not receive any treatment. Patients with two or more positive cultures, with the same organism identified, were denoted as patients with a risk profile and received treatment with a specific antibiotic as determined by the antibiogram for six weeks. The follow-up ranged from a minimum of one year to five years and eleven months, concentrating on the presence or absence of infection, which was defined as discharge of pus through the surgical wound or as a fistula at any time after surgery. The accuracy of this procedure ( number of cases correctly identified in relation to the total number of cases) in the group of 152 arthroplasties in which 4 swabs per patient were collected was 96%. In the group of 111 arthroplasties in which 6 swabs per patient were collected the accuracy was 95.5%. We conclude that the collection of swabs under the conditions described is a method of high accuracy ( above 95%) for the evaluation of risk of infection after primary total hip arthroplasty.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We compared the lignin contents of tropical forages by different analytical methods and evaluated their correlations with parameters related to the degradation of neutral detergent fiber (NDF). The lignin content was evaluated by five methods: cellulose solubilization in sulfuric acid [Lignin (sa)], oxidation with potassium permanganate [Lignin (pm)], the Klason lignin method (KL), solubilization in acetyl bromide from acid detergent fiber (ABLadf) and solubilization in acetyl bromide from the cell wall (ABLcw). Samples from ten grasses and ten legumes were used. The lignin content values obtained by gravimetric methods were also corrected for protein contamination, and the corrected values were referred to as Lignin (sa)p, Lignin (pm)p and KLp. The indigestible fraction of NDF (iNDF), the discrete lag (LAG) and the fractional rate of degradation (kd) of NDF were estimated using an in vitro assay. Correcting for protein resulted in reductions (P < 0.05) in the lignin contents as measured by the Lignin (sa), Lignin (pm) and, especially, the KL methods. There was an interaction (P < 0.05) of analytical method and forage group for lignin content. In general, LKp method provided the higher (P < 0.05) lignin contents. The estimates of lignin content obtained by the Lignin (sa)p, Lignin (pm)p and LKp methods were associated (P > 0.05) with all of the NDF degradation parameters. However, the strongest correlation coefficients for all methods evaluated were obtained with Lignin (pm)p and KLp. The lignin content estimated by the ABLcw method did not correlate (P > 0.05) with any parameters of NDF degradation. There was a correlation (P < 0.05) between the lignin content estimated by the ABLadf method and iNDF content. Nonetheless, this correlation was weaker than those found with gravimetric methods. From these results, we concluded that the gravimetric methods produce residues that are contaminated by nitrogenous compounds. Adjustment for these contaminants is suggested, particularly for the KL method, to express lignin content with greater accuracy. The relationships between lignin content measurements and NDF degradation parameters can be better determined using KLp and Lignin (pm)p methods. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

At present, the sporadic occurrence of human rabies in Brazil can be attributed primarily to dog- and vampire bat-related rabies viruses. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) was employed as a simultaneous detection method for both rabies field variants within 60 min. Vampire bat-related rabies viruses could be distinguished from dog variants by digesting amplicons of the RT-LAMP reaction using the restriction enzyme Alwl. Amplification and digestion could both be completed within 120 min after RNA extraction. In addition, the RI-LAMP assay also detected rabies virus in isolates from Brazilian frugivorous bats and Ugandan dog, bovine and goat samples. In contrast, there were false negative results from several Brazilian insectivorous bats and all of Chinese dog, pig, and bovine samples using the RI-LAMP assay. This study showed that the RT-LAMP assay is effective for the rapid detection of rabies virus isolates from the primary reservoir in Brazil. Further improvements are necessary so that the RT-LAMP assay can be employed for the universal detection of genetic variants of rabies virus in the field. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Animals kept as pets may be considered sentinels for environmental factors to which humans could be exposed. Olfactory and respiratory epithelia are directly subjected to airborne factors, which could cause DNA lesions, and the alkaline comet assay is considered a reliable tool for the assessment of DNA damage. The objective of this work is to evaluate the extent of DNA damage by the comet assay of the olfactory and respiratory epithelia of dogs from different regions of the city of sao Paulo, Brazil. Thirty-three clinically healthy dogs, aged 5 years or more, were used in the study, with 7 from the North region of Sao Paulo, 7 from the South region, 3 dogs from the East region, and 16 dogs from the West city region. Three dogs younger than 6 months were used as controls. DNA damage was analyzed by the alkaline comet assay. We observed no difference in histopathological analysis of olfactory and respiratory epithelia between dogs from different regions of Sao Paulo. Dogs older than 5 years presented significantly higher comet length in both olfactory and respiratory epithelia, when compared with controls, indicating DNA damage. When separated by regions, olfactory and respiratory epithelia presented similar DNA damage in dogs from different regions of Sao Paulo, corroborating with similar levels of particulate matter index (PM10) in all regions of the city. In this study, we report for the first time that the comet assay can be used to quantify the extent of DNA damage in dog olfactory and respiratory epithelia, and that comet length (DNA damage) increases with age, probably due to environmental factors. Air pollution, as measured by PM 10, can be responsible for this DNA damage. (C) 2009 Elsevier GmbH. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A standardised nested-PCR method that amplifies a region of the glycoprotein E gene of avian infectious laryngotracheitis virus (ILTV) has been developed for the diagnosis of infection by Gallid herpesvirus 1. The two sets of primers employed produced the expected ampIification products of 524bp(externa I primers) and 219bp (internal primers) in the presence of ILTV DNA, whereas no Such amplicons were obtained with other avian respiratory pathogens or with DNA extracted from the cells of uninfected chickens. The identity of the 219bp amplified product was con firmed by DNA sequencing. The standardised nested-PCR method detected ILTV DNA from trachea, lung, conjunctiva and trigeminal ganglia samples from flocks of birds with and without clinical signs. and showed hi.-h sensitivity (95.4%) and specificity (93.1%) when compared with the reference test involving virus isolation in specific-pathogen-free chicken embryos. The standardised nested-PCR method described may be used to detect clinical and latent ILTV infections, and will be of significant value for both diagnostic and epidemiological Studies. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Amazonian manatee (Trichechus inunguis) is endemic in the Amazonian basin and is the only exclusively fresh water sirenian. Historically hunted on a large scale, this species is now considered endangered, and Studies on the reproductive physiology are critical for the improvement of reproductive management of captive and wild Populations of manatees. The aim of this Study was to verify the viability of androgen measurement in saliva, lacrimal, urine, and fecal samples of the Amazonian manatee by conducting a hormone challenge. Two adult male manatees (A-1 and A-2) were Submitted to an experimentation protocol of 12 day (D1 to D10). On D0, the animals received an intramuscular injection of gonadotropin-releasing hormone (GnRH)-analogue. Salivary, lacrimal, urinary, and fecal samples were collected daily (between 0800 hours and 0900 hours) and frozen at -20 degrees C until assayed. Fecal samples were lyophilized, extracted with 80% methanol, and diluted in buffer before the radioimmunoassay (RIA). Urine samples underwent acid hydrolysis and were diluted in depleted bovine serum. Salivary and lacrimal samples were assayed without the extraction step. Hormonal assays were conducted with a commercial testosterone RIA kit. An androgen peak (>median + 2 interquartile range [IQR]) was observed in all matrices of both animals, although it was less prominent in the lacrimal samples of A-2. However, the fecal androgen peak (A-1 peak = 293.78 ng/g dry feces, median [IQR] = 143.58 [32.38] ng/g dry feces; A-2 peak = 686.72 ng/g dry feces, median [IQR] = 243.82 [193.16] ng/g dry feces) occurred later than urinary (A-1 peak = 648.16 ng/mg creatinine [Cr], median [IQR] = 23.88 [30.44] ng/mg Cr; A-2 peak = 370.44 ng/mg Cr, median [IQR] = 113.87 [117.73] ng/mg Cr) and salivary (A-1 peak = 678.89 pg/ml, median [IQR] = 103.69 [119.86] pg/ml; A-2 peak = 733.71 pg/ml, median [IQR] = 262.92 [211.44] pg/ml) androgen peaks. These intervals appear to be correlated with the long digesta passage time in this species. The salivary and urinary peaks were closely associated. These results demonstrate that androgen concentrations in saliva, urine, or feces samples reflect reliably physiologic events and are a powerful tool for noninvasive reproductive monitoring of Amazonian manatees.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to determine the relationship among body weight (BW), body condition score (BCS) and rump fat thickness (RFAT) measured by ultrasonography, and validate the relationship between BCS and RFAT over the time. Two hundred sixty and six Nelore cows had their BW, BCS and RFAT evaluated at five different moments during the production cycle: M1) weaning: M2) parturition, M3) 42 days post-partum; M4) 82 days postpartum and M5) 112 days post-partum. A BCS value was attributed for each cow following a I to 5 points scale. Ultrasonographic images for RFAT measurement were obtained using a 3.5 MHz linear transducer. Images were immediately analyzed as soon as they were formed and frozen. Body condition scores and ultrasound measurements were collected on the same day by a single trained technician. The relationship between BCS and RFAT values was investigated by regression models. The analysis of similarity among the five obtained models was performed using the proc MIXED from SAS and the correlations among variables were analyzed with proc CORR from SAS. The BCS was able to predict RFAT in Nelore cows in all different moments evaluated. Also, it was shown that BCS presented high correlation (r=0.82 to 0.93) and relationship (R(2) = 0.73 to 0.92) with RFAT. However, both BCS and RFAT showed low correlation (r=0.37 to 0.50) and relationship (R(2) = 0.13 to 0.25) with BW. The BCS classification by visual method using a 1 to 5 point scale, was able to predict the RFAT in Nelore cows over the time. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Simple, rapid and stable sperm evaluation methods which have been optimized for common marmoset (Callithrix jacchus) are critical for studies involving collection and evaluation of sperm in the field. This is particularly important for new species groups such as Callitrichidae where the sperm have been little studied. Of this family, C jacchus is the best known, and has been chosen as a model species for other members of the genus Callithrix. The fundamental evaluation parameters for sperm of any species are viability and acrosomal status. Semen samples were collected by penile vibratory stimulation. To evaluate sperm plasma membrane integrity, Eosin-Nigrosin was tested here for the common marmoset sperm to be used under field conditions. Further, a non-fluorescent stain for acrosome, the ""Simple"" stain, developed for domestic and wild cats, was tested on common marmoset sperm. This was compared with a fluorescent staining, Fluorescein isothiocyanate-Pisum sativum agglutinin (FITC-PSA), routinely used and validated for common marmoset at the German Primate Centre to evaluate acrosomal integrity. Results obtained with the ""Simple"" stain showed a marked differentiation between sperm with intact and non-intact acrosome both with and without ionophore treatment and closely correlated with results obtained with FITC-PSA. Temperature had no effect on the results with the ""Simple"" stain and the complete processing is simple enough to be carried out under field conditions. These findings indicated that the ""Simple"" stain and Eosin-Nigrosin provide rapid and accurate results for C. jacchus sperm and that those methods can be reliably used as field tools for sperm evaluation for this species. (c) 2008 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this research was to assess the dimensional accuracy of orbital prostheses based on reversed images generated by computer-aided design/computer-assisted manufacturing (CAD/CAM) using computed tomography (CT) scans. Materials and Methods: CT scans of the faces of 15 adults, men and women older than 25 years of age not bearing any congenital or acquired craniofacial defects, were processed using CAD software to produce 30 reversed three-dimensional models of the orbital region. These models were then processed using the CAM system by means of selective laser sintering to generate surface prototypes of the volunteers` orbital regions. Two moulage impressions of the faces of each volunteer were taken to manufacture 15 pairs of casts. Orbital defects were created on the right or left side of each cast. The surface prototypes were adapted to the casts and then flasked to fabricate silicone prostheses. The establishment of anthropometric landmarks on the orbital region and facial midline allowed for the data collection of 31 linear measurements, used to assess the dimensional accuracy of the orbital prostheses and their location on the face. Results: The comparative analyses of the linear measurements taken from the orbital prostheses and the opposite sides that originated the surface prototypes demonstrated that the orbital prostheses presented similar vertical, transversal, and oblique dimensions, as well as similar depth. There was no transverse or oblique displacement of the prostheses. Conclusion: From a clinical perspective, the small differences observed after analyzing all 31 linear measurements did not indicate facial asymmetry. The dimensional accuracy of the orbital prostheses suggested that the CAD/CAM system assessed herein may be applicable for clinical purposes. Int J Prosthodont 2010;23:271-276.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. The objectives of this study were to assess the accuracy of working length determination using 3 electronic apex locators and direct digital radiography and to compare the results with those obtained using the visual method (control measurement). Study design. Twenty extracted human maxillary premolars were selected: 17 two-rooted and 3 single-rooted (total of 37 canals). Working length was measured using electronic apex locators Elements Diagnostic, Root ZX, and Just II. Subsequently, teeth were positioned in the alveolar bone of a dry skull and submitted to direct digital radiography. A variation of +/- 1 mm was considered as acceptable. Results were analyzed using the Wilcoxon and the chi(2) tests. Results. Results presented an accuracy of 94.6% for Elements Diagnostic, 91.9% for Root ZX, 73.0% for Just II, and 64.9% for direct digital radiography when considering the margin of +/- 1 mm in relation to the control measurement. Comparisons with the actual control measurements resulted in accuracy results of 13.51%, 13.51%, 10.10%, and 2.70%, respectively. Conclusions. Root ZX and Elements Diagnostic are more accurate in determining working length when compared with Just II and Schick direct digital radiography. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011;111:e44-e49)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The diagnosis of caries lesions is still a matter of concern in dentistry. The diagnosis of dental caries by digital radiography has a number of advantages over conventional radiography; however, this method has not been explored fully in the field of paediatric dentistry. This in vitro research evaluated the accuracy of direct digital radiography compared with visual inspection and conventional radiography in the diagnosis of occlusal caries lesions in primary molars. Methods: 50 molars were selected and evaluated under standardized conditions by 2 previously calibrated examiners according to 3 diagnostic methods (visual inspection, conventional radiography and direct digital radiography). Direct digital radiographs were obtained with the Dixi3 system (Planmeca, Helsinki, Finland) and the conventional radiographs with InSight film (Kodak Eastman Co., Rochester, NY). The images were scored and a reference standard was obtained histologically. The interexaminer reliability was calculated using Cohen`s kappa test and the specificity, sensitivity and accuracy of the methods were calculated. Results: Examiner reliability was good. For lesions limited to the enamel, visual inspection showed significantly higher sensitivity and accuracy than both radiographic methods, but no significant difference was found in specificity. For teeth with dentinal caries, no significant differences were found for any parameter when comparing visual and radiographic evaluation. Conclusions: Although less accurate than the visual method for detecting caries lesions confined to the enamel, the direct digital radiographic method is as effective as conventional radiographic examination and visual inspection of primary teeth with occlusal caries when the dentine is involved. Dentomaxillofacial Radiology (2010) 39, 362-367. doi: 10.1259/dmfr/22865872