192 resultados para Separation
Resumo:
A liquid chromatography method is described for the analysis of fluoxetine and norfluoxetine enantiomers in fungi cultures. The analytes were separated simultaneously by LC employing a serial system. The resolution was performed using a mobile phase of ethanol: 15 mM ammonium acetate buffer solution, pH 5.9: acetonitrile (77.5:17.5:5, v/v/v). UV detection was at 227 nm. Hexane: isoamyl alcohol (98:2, v/v) was used as extractor solvent. The calibration curves were linear over the concentration range of 12.5-3,750 ng mL(-1) (r a parts per thousand yen 0.996). The values for intra- and inter-day precision and accuracy were a parts per thousand currency sign10% for all analytes. The validated method was used to evaluate fluoxetine biotransformation to its mammalian metabolite, norfluoxetine, by selected endophytic fungi. Although the desired biotransformation was not observed in the conditions used here, the method could be used to evaluate the biotransformation of fluoxetine by other fungi or to be extended to other matrices with adequate procedures for sample preparation.
Resumo:
An experimental design optimization (Box-Behnken design, BBD) was used to develop a CE method for the simultaneous resolution of propranolol (Prop) and 4-hydroxypropranolol enantiomers and acetaminophen (internal standard). The method was optimized using an uncoated fused silica capillary, carboxymethyl-beta-cyclodextrin (CM-beta-CD) as chiral selector and triethylamine/phosphoric acid buffer in alkaline conditions. A BBD for four factors was selected to observe the effects of buffer electrolyte concentration, pH, CM-beta-CD concentration and voltage on separation responses. Each factor was studied at three levels: high, central and low, and three center points were added. The buffer electrolyte concentration ranged from 25 to 75 mM, the pH ranged from 8 to 9, the CM-beta-CD concentration ranged from 3.5 to 4.5%w/v, and the applied run voltage ranged from 14 to 20 W. The responses evaluated were resolution and migration time for the last peak. The obtained responses were processed by Minitab (R) to evaluate the significance of the effects and to find the optimum analysis conditions. The best results were obtained using 4%w/v CM-beta-CD in 25 mM triethylamine/H(3)PO(4) buffer at pH 9 as running electrolyte and 17 kV of voltage. Resolution values of 1.98 and 1.95 were obtained for Prop and 4-hydroxypropranolol enantiomers, respectively. The total analysis time was around of 15 min. The BBD showed to be an adequate design for the development of a CE method, resulting in a rapid and efficient optimization of the pH and concentration of the buffer, cyclodextrin concentration and applied voltage.
Resumo:
(+/-)-Licarin A (1), a neolignan obtained by the oxidative coupling reaction of isoeugenol, had in this study its enantiomers resolved. A novel, quick and efficient enantiomeric resolution of 1 was directly performed by chiral high-performance liquid chromatography (HPLC-PDA) protocol (CHIRALPACK (R) AD column; 9:1 (v/v) n-hexane:2-propanol; 1.0 mL/min). This method provided a chromatogram profile with a well-resolved peak separation. After isolation of each enantiomer with ee >99.9%, they were analysed in a polarimeter. Compound 2, which showed a retention time (t(r)) of 12.13 min, was the (+)-enantiomer and compound 3 (t(r) =18.90 min) was the (-)-enantiomer. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
LEITE, V. G., F. S. MARQUIAFAVEL, D. P. MORAES, AND S. P. TEIXEIRA (Departamento de Ciencias Farmaceuticas, Faculdade de Ciencias Farmaceuticas de Ribeirao Preto, Universidade de Sao Paulo (USP), Av. do Cafe, s/n, 14040-903 Ribeirao Preto, SP, Brazil). Fruit anatomy of Neotropical species of Indigofera (Leguminosae, Papilionoideae) with functional and taxonomic implications. J. Torrey Bot. Soc. 136: 203-211. 2009-This work reports on the fruit surface and anatomy of seven Neotropical species of Indigofera (I. campestris Bong. ex Benth., I. hirsuta L., I. lespedeziodes Kunth, I. microcarpa Desv., I. spicata Forssk., I. suffruticosa Mill., and I. truxillensis Kunth) to help species diagnosis and clarify the fruit type classification. Flowers and fruits at several stages of development were removed from living material, fixed, and examined with scanning electron (surface analyses) and light microscopies (histological analyses). Species showed differences in relation to the number of exocarp layers, secretory trichome morphology and distribution, presence of stomata, phenolic idioblast size and distribution in mesocarp, the number and arrangement of endocarp fibers, and the presence of it separation tissue. It is noteworthy that no separation tissue was observed in L microcarpa and I. suffruticosa, although they have dehiscent fruits, which indicates it delayed dehiscence. The present work confirms that fruit anatomical characters can be utilized as it tool for fruit type classification, especially in Indigofera, the third largest genus of Leguminosae.
Resumo:
Despite the necessity to differentiate chemical species of mercury in clinical specimens, there area limited number of methods for this purpose. Then, this paper describes a simple method for the determination of methylmercury and inorganic mercury in blood by using liquid chromatography with inductively coupled mass spectrometry (LC-ICP-MS) and a fast sample preparation procedure. Prior to analysis, blood (250 mu L) is accurately weighed into 15-mL conical tubes. Then, an extractant solution containing mercaptoethanol, L-cysteine and HCI was added to the samples following sonication for 15 min. Quantitative mercury extraction was achieved with the proposed procedure. Separation of mercury species was accomplished in less than 5 min on a C18 reverse-phase column with a mobile phase containing 0.05% (v/v) mercaptoethanol, 0.4% (m/v) L-cysteine, 0.06 mol L(-1) ammonium acetate and 5% (v/v) methanol. The method detection limits were found to be 0.25 mu g L(-1) and 0.1 mu Lg L(-1) for inorganic mercury and methylmercury, respectively. Method accuracy is traceable to Standard Reference Material (SRM) 966 Toxic Metals in Bovine Blood from the National Institute of Standards and Technology (NIST). The proposed method was also applied to the speciation of mercury in blood samples collected from fish-eating communities and from rats exposed to thimerosal. With the proposed method there is a considerable reduction of the time of sample preparation prior to speciation of Hg by LC-ICP-MS. Finally, after the application of the proposed method, we demonstrated an interesting in vivo ethylmercury conversion to inorganic mercury. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
A simple method for mercury speciation in hair samples with a fast sample preparation procedure using high-performance liquid chromatography coupled to inductively coupled plasma mass spectrometry is proposed. Prior to analysis, 50 mg of hair samples were accurately weighed into 15 mL conical tubes. Then, an extractant solution containing mercaptoethanol, L-cysteine and HCl was added to the samples following sonication for 10 min. Quantitative mercury extraction was achieved with the proposed procedure. Separation of inorganic mercury (Ino-Hg), methylmercury (Met-Hg) and ethylmercury (Et-Hg) was accomplished in less than 8 min on a C18 reverse phase column with a mobile phase containing 0.05% v/v mercaptoethanol, 0.4% m/v L-cysteine, 0.06 mol L(-1) ammonium acetate and 5% v/v methanol. The method detection limits were found to be 15 ng g(-1), 10 ng g(-1) and 38 ng g(-1), for inorganic mercury, methylmercury and ethylmercury, respectively. Sample throughput is 4 samples h(-1) (duplicate). A considerable improvement in the time of analysis was achieved when compared to other published methods. Method accuracy is traceable to Certified Reference Materials (CRMs) 85 and 86 human hair from the International Atomic Energy Agency (IAEA). Finally, the proposed method was successfully applied to the speciation of mercury in hair samples collected from fish-eating communities of the Brazilian Amazon.
Resumo:
This paper describes a simple method for mercury speciation in seafood samples by LC-ICP-MS with a fast sample preparation procedure. Prior to analysis, mercury species were extracted from food samples with a solution containing mercaptoethanol, L-cysteine and HCl and sonication for 15 min. Separation of mercury species was accomplished in less than 5 min on a C8 reverse phase column with a mobile phase containing 0.05%-v/v mercaptoethanol, 0.4% m/v L-cysteine and 0.06 mol L(-1) ammonium acetate. The method detection limits were found to be 0.25, 0.20 and 0.1 ng g(-1) for inorganic mercury, ethylmercury and methylmercury, respectively. Method accuracy is traceable to Certified Reference Materials (DOLT-3 and DORM-3) from the National Research Council Canada (NRCC). With the proposed method there is a considerable reduction of the time of sample preparation. Finally, the method was applied for the speciation of mercury in seafood samples purchased from the Brazilian market. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
A simple and fast method is described for simultaneous determination of methylmercury (MeHg), ethylmercury (Et-Hg) and inorganic mercury (Ino-Hg) in blood samples by using capillary gas chromatography-inductively coupled plasma mass spectrometry (GC-ICP-MS) after derivatization and alkaline digestion. Closed-vessel microwave assisted digestion conditions with tetramethylammonium hydroxide (TMAH) have been optimized. Derivatization by using ethylation and propylation procedures have also been evaluated and compared. The absolute detection limits (using a 1 mu L injection) obtained by GC-ICP-MS with ethylation were 40 fg for MeHg and Ino-Hg, respectively, and with propylation were 50, 20 and 50 fg for MeHg, Et-Hg and Ino-Hg, respectively. Method accuracy is traceable to Standard Reference Material (SRM) 966 Toxic Metals in Bovine Blood from the National Institute of Standards and Technology (NIST). Additional validation is provided based on the comparison of results obtained for mercury speciation in blood samples with the proposed procedure and with a previously reported LC-ICP-MS method. With the new proposed procedure no tedious clean-up steps are required and a considerable improvement of the time of analysis was achieved compared to other methods using GC separation.
Resumo:
The aqueous extract prepared from Schizolobium parahyba (Sp) leaves, a native plant from Atlantic Forest (Brazil), was tested to analyse its ability to inhibit some biological and enzymatic activities induced by Bothrops alternatus (BaltCV) and Bothrops moojeni (BmooCV) snake venoms. Sp inhibited 100% of lethality, blood incoagulability, haemorrhagic and indirect haemolytic activities at a 1:10 ratio (venom/extract, w/w), as well as coagulant activity at a 1:5 ratio (venom/extract, w/w) induced by both venoms. BaltCV fibrinogenolytic activity was also neutralized by Sp at a 1:10 ratio, resulting in total protection of fibrinogen B beta chain and partial protection of A alpha chain. Interaction tests have demonstrated that, at certain extract/proteins ratios, Sp precipitates proteins non-specifically suggesting the presence of tannins, which are very likely responsible for the excellent inhibiting effects of the analysed ophidian activities. Sp aqueous extract chromatography on Sephadex LH-20 was carried out aiming at the separation of these compounds that mask the obtained results. Thus, the fractionation of Sp resulted in three fractions: F1 (methanolic fraction); F2 (methanol:water fraction, 1:1 v/v); and F3 (aqueous fraction). These fractions were analysed for their ability to inhibit the BaltCV fibrinogenolytic activity. F1 inhibited 100% the venom fibrinogenolytic activity without presenting protein precipitation effect; F2 showed only partial inhibition of this venom activity. Finally, F3 did not inhibit fibrinogen proteolysis, but presented strong protein precipitating action. We conclude that Sp aqueous extract, together with tannins, also contains other compounds that can display specific inhibitory activity against snake venom toxins.
Resumo:
The current taxonomy of two poorly known hermit crab species Pagurus forceps H. Milne Edwards, 1836 and Pagurus comptus White, 1847 from temperate Pacific and Atlantic coastlines of South America is based only on adult morphology. Past studies have questioned the separation of these two very similar species, which occur sympatrically. We included specimens morphologically assignable to P. forceps and P. comptus in a phylogenetic analysis, along with other selected anomuran decapods, based on 16S ribosomal gene sequences. Differences between samples putatively assigned to either P. forceps and P. comptus were moderate, with sequence similarity ranging from 98.2 to 99.4% for the fragments analyzed. Our comparison of mitochondrial DNA sequences (16S rRNA) revealed diagnostic differences between the two putative species, suggesting that P. forceps and P. comptus are indeed phylogenetically close but different species, with no genetic justification to support their synonymization. The polyphyly of Pagurus is not corroborated here among the represented Atlantic species, despite obviously complex relationships among the members of the genus.
Resumo:
A sensitive and reproducible stir bar-sorptive extraction and high-performance liquid chromatography-UV detection (SBSE/HPLC-UV) method for therapeutic drug monitoring of carbamazepine, carbamazepine-10,11-epoxide, phenytoin and phenobarbital in plasma samples is described and compared with a liquid:liquid extraction (LLE/HPLC-UV) method. Important factors in the optimization of SBSE efficiency such as pH, extraction time and desorption conditions (solvents, mode magnetic stir, mode ultrasonic stir, time and number of steps) assured recoveries ranging from 72 to 86%, except for phenytoin (62%). Separation was obtained using a reverse phase C-18 column with UV detection (210 nm). The mobile phase consisted of water: acetonitrile (78:22, v/v). The SBSE/HPLC-UV method was linear over a working range of 0.08-40.0 mu g mL(-1) for carbamazepine, carbamazepine-10,11-epoxide and phenobarbital and 0.125-40.0 mu g mL(-1) for phenytoin, The intra-assay and inter-assay precision and accuracy were studied at three concentrations (1.0, 4.0 and 20.0 mu g mL(-1)). The intra-assay coefficients of variation (CVs) for all compounds were less than 8.8% and all inter-CVs were less than 10%. Limits of quantification were 0.08 mu g mL(-1) for carbamazepine, carbamazepine-10,11-epoxide and phenobarbital and 0.125 mu g mL(-1) for phenytoin. No interference of the drugs normally associated with antiepileptic drugs was observed. Based on figures of merit results, the SBSE/HPLC-UV proved adequate for antiepileptic drugs analyses from therapeutic levels. This method was successfully applied to the analysis of real samples and was as effective as the LLE/HPLC-UV method. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
This work presents the synthesis and characterization of a series of substituted pyridylpentafluroporphyrins, including the separation of the cis- and trans-isomers, the latter being characterized by X-ray crystallography. The spectroscopic and electrochemical properties of the series are dependent on the number of electron withdrawing pentafluorophenyl substituent, but they do not depend on the symmetry of the molecule. Ongoing from the monosubstituted to the more substituted pentafluorophenyl porphyrin H(2)(MPyTFPP) derivative, the Soret bands are slightly red-shifted and their quantum fluorescence yields range from 0.035 to 0.046, consistent with the value of 0.045 for the fully substituted 5,10,15,20-tetrapentafluorophenylporphyrin (dichloromethane solutions). The redox potentials of the reductive processes of monoanion and dianion formation are also sensitive to the number of pentafluoro substituents, shifting 180 mV to more positive values for the P(0)/P(-1) process ongoing from the monopentafluoro to the tris-pentafluorophenyl substituted derivative.
Resumo:
The commercially available Jacobsen catalyst, Mn(salen), was occluded in hybrid polymeric membranes based on poly(dimethylsiloxane) (PDMS) and poly(vinyl alcohol) (PVA). The obtained systems were characterized by UV-vis spectroscopy and SEM techniques. The membranes were used as a catalytic barrier between two different phases: an organic substrate phase (cyclooctene or styrene) in the absence of solvent, and an aqueous solution of either t-BuOOH or H(2)O(2). Membranes containing different percentages of PVA were prepared, in order to modulate their hydrophilic/hydrophobic swelling properties. The occluded complex proved to be an efficient catalyst for the oxidation of alkenes. The new triphasic system containing a cheap and easily available catalyst allowed substrate oxidation and easy product separation using ""green"" oxidants. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
A sensitive and precise stir bar sorptive extraction (SBSE) combined with LC (SBSE/LC) analysis is described for simultaneous determination of methyl, ethyl, propyl, and butyl parabens in commercial cosmetic products in agreement with the European Union Cosmetics Directive 76/768/EEC. Important factors in the optimization of SB SE efficiency are discussed, such as time and temperature of extraction, pH, and ionic strength of the sample, matrix effects, and liquid desorption conditions by different modes (magnetic stirring, ultrasonic). The LOQs of the SBSE/LC method ranged from 30 to 200 ng/mg, with linear response over a dynamic range, from the LOQ to 2.5 mu g/mg, with a coefficient of determination higher than 0.993. The interday precision of the SBSE/LC method presented a coefficient of variation lower than 5%. The effectiveness of the proposed method was proven for analysis of commercial cosmetic products such as body creams, antiperspirant creams, and sunscreens.
Resumo:
A sensitive and reproducible stir bar-sorptive extraction and high performance liquid chromatography-UV detection (SBSE/HPLC-UV) method for therapeutic drug monitoring of rifampicin in plasma samples is described and compared with a liquid:liquid extraction (LLE/HPLC-UV) method. This miniaturized method can result in faster analysis, higher sample throughput, lower solvent consumption and less workload per sample while maintaining or even improving sensitivity. Important factors in the optimization of SBSE efficiency such as pH, temperature, extraction time and desorption conditions (solvents, mode magnetic stir, mode ultrasonic stir, time and number of steps) were optimized recoveries ranging from 75 to 80%. Separation was obtained using a reverse phase C(8) column with UV detection (254 nm). The mobile phase consisted of methanol:0.25 N sodium acetate buffer, pH 5.0 (58:42, v/v). The SBSE/HPLC-UV method was linear over a working range of 0.125-50.0 mu g mL(-1). The intra-assay and inter-assay precision and accuracy were studied at three concentrations (1.25, 6.25 and 25.0 mu g mL(-1)). The intra-assay coefficients of variation (CVs) for all compounds were less than 10% and all inter-CVs were less than 10%. Limits of quantification were 0.125 mu g mL(-1). Stability studies showed rifampicin was stable in plasma for 12 h after thawing; the samples were also stable for 24 h after preparation. Based on the figures of merit results, the SBSE/HPLC-UV proved to be adequate to the rifampicin analyses from therapeutic to toxic levels. This method was successfully applied to the analysis of real samples and was as effective as the LLE/HPLC-UV method. (C) 2009 Elsevier B.V. All rights reserved.