283 resultados para Standard method
Resumo:
In stored grains, smaller depositions and great variation with respect to theoretical insecticide doses are frequently found. The objective of this work was to study the effectiveness of the standard method (ISO 5682/1-1996) employed to evaluate hydraulic nozzles used in stored corn and wheat grain protection experiments. The transversal volumetric distribution and droplet spectrum of a model TJ-60 8002EVS nozzle were determined in order to calibrate a spraying system for an application rate of 5 L/t and to obtain theoretical concentrations of 10 and 0.5 mg/kg of fenitrothion and esfenvalerate, respectively. After treatment, the corn and wheat grains were processed and deposition was analyzed by gas chromatography. The type of grain did not have any influence on insecticide deposition and was dependent upon insecticide only. The insecticide deposits on the grains only reached 42.1 and 38.2% of the intended theoretical values for fenitrothion and esfenvalerate concentrations, respectively. These results demonstrate the ineffectiveness of the standard evaluation method for hydraulic nozzles employed in stored grain protection experiments.
Resumo:
Background: We report the validation of a method for the determination of acetaldehyde, acetone, methanol, and ethanol in biological fluids using manual headspace sample introduction and an acetonitrile internal standard. Method: This method uses a capillary column (I = 30 m, I.D. = 0.25 mm, dF = 0.25 mu m) installed in a gas chromatography-flame ionization detector (GC-FID) apparatus with a run time of 7.5 minutes. Results: Analysis of the retention times and the resolution of the analyte peaks demonstrated excellent separation without widening of the peaks. Precision and accuracy were good (interassay precision < 15% and recovery between 85% and 115%) in both blood and urine. Conclusion: The method was linear (r > 0.09) over the analytical measurement range (AMR) of each analyte.
Resumo:
PURPOSE: To analyze the usefulness of the weight gain/height gain ratio from birth to two and three years of age as a predictive risk indicator of excess weight at preschool age. METHODS: The weight and height/length of 409 preschool children at daycare centers were measured according to internationally recommended rules. The weight values and body mass indices of the children were transformed into a z-score per the standard method described by the World Health Organization. The Pearson correlation coefficients (rP) and the linear regressions between the anthropometric parameters and the body mass index z-scores of preschool children were statistically analyzed (alpha = 0.05). RESULTS: The mean age of the study population was 3.2 years (± 0.3 years). The prevalence of excess weight was 28.8%, and the prevalence of overweight and obesity was 8.8%. The correlation coefficients between the body mass index z-scores of the preschool children and the birth weights or body mass indices at birth were low (0.09 and 0.10, respectively). There was a high correlation coefficient (rP = 0.79) between the mean monthly gain of weight and the body mass index z-score of preschool children. A higher coefficient (rP = 0.93) was observed between the ratio of the mean weight gain per height gain (g/cm) and the preschool children body mass index z-score. The coefficients and their differences were statistically significant. CONCLUSION: Regardless of weight or length at birth, the mean ratio between the weight gain per g/cm of height growth from birth presented a strong correlation with the body mass index of preschool children. These results suggest that this ratio may be a good indicator of the risk of excess weight and obesity in preschool-aged children.
Resumo:
Objective. Endomyocardial biopsy (EMB), which is used to monitor for rejection, may cause tricuspid regurgitation (TR) after orthotopic heart transplantation (OHT). The purpose of this investigation was to examine the occurrence of tricuspid valve tissue in myocardial specimens obtained by routine EMB performed after OHT. Patients and Methods. From January 2000 to July 2008, 125 of the patients who underwent OHT survived more than I month. Their follow-up varied from I month to 8.5 years (mean, 5.1 +/- 3.7 years). EMB was the gold standard examination and myocardial scintigraphy with gallium served as a screen to routinely monitor rejection. Results. Each of 428 EMB including 4 to 7 fragments, totaling 1715 fragments, were reviewed for this study. The number of EMB per patient varied from 3 to 8 (mean, 4.6 +/- 3.5). Histopathological analysis of these fragments showed tricuspid tissue in 4 patients (3.2%), among whom only I showed aggravation of TR. Conclusions. EMB remains the standard method to diagnose rejection after OLT. It can be performed with low risk. Reducing the number of EMB using gallium myocardial scintigraphy or other alternative methods as well as adoption of special care during the biopsy can significantly minimize trauma to the tricuspid valve.
Resumo:
Objectives/Hypothesis: Polysomnography (PSG) is the gold-standard method for diagnosing obstructive sleep apnea (OSA). However, the gap between demand and capacity in performing PSG is a major health-care problem. We sought to validate a short day-time induced sleep for the diagnosis of OSA. Study Design: Prospective diagnostic method validation. Methods: We studied 25 consecutive patients referred to the sleep laboratory and 15 healthy volunteers. All subjects were evaluated by means of full overnight PSG (Full-PSG) and short day-time induced-sleep PSG (Induced-PSG). Sleep was monitored during both procedures (Embla, 16 channels). Sleep was induced by slow intravenous drip infusion of midazolam. Results: The population studied (N = 40) was 60% male (mean age, 42 +/- 10 years; body mass index, 29 +/- 6.5 kg/m(2)). Sleep was successfully induced in all subjects, and no complications were observed (midazolam doses, 6.2 +/- 3.8 mg; time of induced sleep 41.5 +/- 18.9 minutes). The apnea-hypopnea index (AHI) and minimal oxygen saturation during Full-PSG versus Induced-PSG were similar: median AHI (with 25%-75% interquartile range) was 13 (3-35) events per hour versus 17 (4-36) events per hour, and median oxygen saturation was 84% (75-90) versus 85% (76-92); P = .89 and P = .53, respectively. The majority of the respiratory events during induced sleep were obstructive and similar to those observed during Full-PSG. AHI and lowest oxygen saturation during Induced-PSG correlated significantly with Full-PSG (r = 0.67 and r = 0.77, respectively). Sensitivity and specificity for the diagnosis of OSA (AHI > 15 events per hour) by Induced-PSG were 0.83 and 0.72, respectively. Conclusions: Induced-PSG by midazolam during the day is safe and correlates with Full-PSG; it therefore is a promising alternative method in the diagnosis of OSA.
Resumo:
The platelet blood count in laboratorial routine provides to the clinician important information about the hemostasis of the patient. There are many techniques described, however the gold standard techniques realized in hemocytometer spent a lot of time, making this technique impracticable in great routines. This research had the intent to evaluate if the automatic veterinary blood counter QBC Vet Autoread (R), whose results get five minutes to be ready, is capable to offer a trustworthy platelet count number. To this end, were evaluated the correlations among three different forms of platelets count in dogs: count in automatic blood counter QBC Vet Autoread (R), estimative in blood smear and the gold standard method by manual count in hemocytometer. The viability and confidence use of automatic blood counters of the medicine veterinary routine. Seventeen dogs were chosen randomly way, in the medical and surgical routine of HOVET-USP. The analysis revel high correlation between the hemocytometer and the estimative in blood smear (r=0,875) and between the hemocytometer and automatic blood count by QBC Vet Autoread (R) (r=0,939). Conclude that the platelet blood cont by QBC Vet Autoread (R), in addition to be fast, it`s more truthful when compared with estimative in blood smear, although the latter one also had elevated correlation. However, morphological analysis through the smears cannot be dismissed because none of the other two techniques evaluated have the ability to assess platelet morphological changes.
Resumo:
The structural and electronic properties of perylene diimide liquid crystal PPEEB are studied using ab initio methods based on the density functional theory (I)FT). Using available experimental crystallographic data as a guide, we propose a detailed structural model for the packing of solid PPEEB. We find that due to the localized nature of the band edge wave function, theoretical approaches beyond the standard method, such as hybrid functional (PBE0), are required to correctly characterize the band structure of this material. Moreover, unlike previous assumptions, we observe the formation of hydrogen bonds between the side chains of different molecules, which leads to a dispersion of the energy levels. This result indicates that the side chains of the molecular crystal not only are responsible for its structural conformation but also can be used for tuning the electronic and optical properties of these materials.
Resumo:
In this article, we present the EM-algorithm for performing maximum likelihood estimation of an asymmetric linear calibration model with the assumption of skew-normally distributed error. A simulation study is conducted for evaluating the performance of the calibration estimator with interpolation and extrapolation situations. As one application in a real data set, we fitted the model studied in a dimensional measurement method used for calculating the testicular volume through a caliper and its calibration by using ultrasonography as the standard method. By applying this methodology, we do not need to transform the variables to have symmetrical errors. Another interesting aspect of the approach is that the developed transformation to make the information matrix nonsingular, when the skewness parameter is near zero, leaves the parameter of interest unchanged. Model fitting is implemented and the best choice between the usual calibration model and the model proposed in this article was evaluated by developing the Akaike information criterion, Schwarz`s Bayesian information criterion and Hannan-Quinn criterion.
Resumo:
This paper describes the applications of anew carbon paste electrode containing fibers of coconut (Cocus nucifera L) fruit, which are very rich in peroxidase enzymes naturally immobilized on its structure. The new sensor was applied for the amperometric quantification of benzoyl peroxide in facial creams and dermatological shampoos. The amperometric measurements were performed in 0.1 mol L(-1) phosphate buffer (pH 5.2), at 0.0 V (versus Ag/AgCl). On these conditions, benzoyl peroxide was rapidly determined in the 5.0-55 mu mol L(-1), with a detection limit of 2.5 mu mol L(-1) (s/n = 3), response time of 4.1 s (90% of the steady state) and sensitivity limit of 0.33 A mol L(-1) cm(-2). The amperometric results are in good agreement with those obtained by spectrophotometric technique, used as a standard method. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
A method is reported for the quantification of isoorientin (using a standard addition method) and total flavonoids (expressed as rutin, using the external standard method) in passion fruit pulp (Passiflora edulis Sims f. flavicarpa Degener, Passifloraceae). Extraction of flavonoids was optimized by experimental design methodology, and quantitative analysis was performed by high-performance liquid chromatography with photo-diode array detection (HPLC-UV/DAD). The method was developed and validated according to ICH requirements for specificity, linearity, accuracy, precision (repeatability and intermediate precision). LOD and LOQ. Rutin was chosen as standard for the quantification of total flavonoids in order to propose a HPLC method feasible for routine analysis of the flavonoids in the passion fruit pulp. The passion fruit pulp contained 16.226 +/- 0.050 mg L(-1) of isoorientin and 158.037 +/- 0.602 mg L(-1) of total flavonoid, suggesting that P. edulis fruits may be comparable with other flavonoid food sources such as orange juice or sugarcane juice. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
A simple and fast capillary zone electrophoresis (CZE) method has been developed and validated for quantification of a non-nucleoside reverse transcriptase inhibitor (NNRTI) nevirapine, in pharmaceuticals. The analysis was optimized using 10 mmol L-1 sodium phosphate buffer pH 2.5, +25 kV applied voltage, hydrodynamic injection 0.5 psi for 5 s and direct UV detection at 200 µm. Diazepam (50.0 µg mL-1) was used as internal standard. Under these conditions, nevirapine was analyzed in approximately less than 2.5 min. The analytical curve presented a coefficient of correlation of 0.9994. Limits of detection and quantification were 1.4 µg mL-1 and 4.3 µg mL-1, respectively. Intra- and inter-day precision expressed as relative standard deviations were 1.4% and 1.3%, respectively and the mean recovery was 100.81%. The active pharmaceutical ingredient was subjected to hydrolysis (acid, basic and neutral) and oxidative stress conditions. No interference of degradation products and tablet excipients were observed. This method showed to be rapid, simple, precise, accurate and economical for determination of nevirapine in pharmaceuticals and it is suitable for routine quality control analysis since CE offers benefits in terms of quicker method development and significantly reduced operating costs.
Resumo:
Background Minimal residual disease is an important independent prognostic factor in childhood acute lymphoblastic leukemia. The classical detection methods such as multiparameter flow cytometry and real-time quantitative polymerase chain reaction analysis are expensive, time-consuming and complex, and require considerable technical expertise. Design and Methods We analyzed 229 consecutive children with acute lymphoblastic leukemia treated according to the GBTLI-99 protocol at three different Brazilian centers. Minimal residual disease was analyzed in bone marrow samples at diagnosis and on days 14 and 28 by conventional homo/heteroduplex polymerase chain reaction using a simplified approach with consensus primers for IG and TCR gene rearrangements. Results At least one marker was detected by polymerase chain reaction in 96.4%, of the patients. By combining the minimal residual disease results obtained on days 14 and 28, three different prognostic groups were identified: minimal residual disease negative on days 14 and 28, positive on day 14/negative on day 28, and positive on both. Five-year event-free survival rates were 85%, 75.6%,, and 27.8%, respectively (p<0.0001). The same pattern of stratification held true for the group of intensively treated children. When analyzed in other subgroups of patients such as those at standard and high risk at diagnosis, those with positive B-derived CD10, patients positive for the TEL/AML1 transcript, and patients in morphological remission on a day 28 marrow, the event-free survival rate was found to be significantly lower in patients with positive minimal residual disease on day 28. Multivariate analysis demonstrated that the detection of minimal residual disease on day 28 is the most significant prognostic factor. Conclusions This simplified strategy for detection of minimal residual disease was feasible, reproducible, cheaper and simpler when compared with other methods, and allowed powerful discrimination between children with acute lymphoblastic leukemia with a good and poor outcome.
Resumo:
The objective of this work was to develop and validate a rapid Reversed-Phase High-Performance Liquid Chromatography method for the quantification of 3,5,3 '-triiodothyroacetic acid (TRIAC) in nanoparticles delivery system prepared in different polymeric matrices. Special attention was given to developing a reliable reproductive technique for the pretreatment of the samples. Chromatographic runs were performed on an Agilent 1200 Series HPLC with a RP Phenomenex (R) Gemini C18 (150 x 4, 6 mm i.d., 5 mu m) column using acetonitrile and triethylamine buffer 0.1% (TEA) (40 : 60 v/v) as a mobile phase in an isocratic elution, pH 5.6 at a flow rate of 1 ml min(-1). TRIAC was detected at a wavelength of 220 nm. The injection volume was 20 mu l and the column temperature was maintained at 35 degrees C. The validation characteristics included accuracy, precision, specificity, linearity, recovery, and robustness. The standard curve was found to have a linear relationship (r(2) - 0.9996) over the analytical range of 5-100 mu g ml(-1) . The detection and quantitation limits were 1.3 and 3.8 mu g ml(-1), respectively. The recovery and loaded TRIAC in colloidal system delivery was nearly 100% and 98%, respectively. The method was successfully applied in polycaprolactone, polyhydroxybutyrate, and polymethylmethacrylate nanoparticles.
Resumo:
An analytical procedure for multiple standard additions of arsenic species using sequential injection analysis (SIA) is proposed for their quantification in seafood extracts. SIA presented flexibility for generating multiple specie standards at the ng mL(-1) concentration level by adding different volumes of As(III), As(V), monomethylarsonic (MMA) and dimethylarsinic (DMA) to the sample. The mixed sample plus standard solutions were delivered from SIA to fill the HPLC injection loop. Subsequently, As species were separated by HPLC and analyzed by atomic fluorescence spectrometry (AFS). The proposed system comprised two independently controlled modules, with the HPLC loop acting as the intermediary device. The analytical frequency was enhanced by combining the actions of both modules. While the added sample was flowing through the chromatographic column towards the detection system, the SIA program started performing the standard additions to another sample. The proposed method was applied to spoiled seafood extracts. Detection limits based on 3 sigma for As(III), As(V), MMA and DMA were 0.023, 0.39, 0.45 and 1.0 ng mL(-1), respectively. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
This work presents an analysis of the wavelet-Galerkin method for one-dimensional elastoplastic-damage problems. Time-stepping algorithm for non-linear dynamics is presented. Numerical treatment of the constitutive models is developed by the use of return-mapping algorithm. For spacial discretization we can use wavelet-Galerkin method instead of standard finite element method. This approach allows to locate singularities. The discrete formulation developed can be applied to the simulation of one-dimensional problems for elastic-plastic-damage models. (C) 2007 Elsevier Inc. All rights reserved.