225 resultados para Conventional sprinkler


Relevância:

20.00% 20.00%

Publicador:

Resumo:

For centuries, specific instruments or regular toothbrushes have routinely been used to remove tongue biofilm and improve breath odor. Toothbrushes with a tongue scraper on the back of their head have recently been introduced to the market. The present study compared the effectiveness of a manual toothbrush with this new design, i.e., possessing a tongue scraper, and a commercial tongue scraper in improving breath odor and reducing the aerobic and anaerobic microbiota of tongue surface. The evaluations occurred at 4 moments, when the participants (n=30) had their halitosis quantified with a halimeter and scored according to a 4-point scoring system corresponding to different levels of intensity. Saliva was collected for counts of aerobic and anaerobic microorganisms. Data were analyzed statistically by Friedman's test (p<0.05). When differences were detected, the Wilcoxon test adjusted for Bonferroni correction was used for multiple comparisons (group to group). The results confirmed the importance of mechanical cleaning of the tongue, since this procedure provided an improvement in halitosis and reduction of aerobe and anaerobe counts. Regarding the evaluated methods, the toothbrush's tongue scraper and conventional tongue scraper had a similar performance in terms of breath improvement and reduction of tongue microbiota, and may be indicated as effective methods for tongue cleaning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This in vivo study evaluated the dissociation quality of maxillary premolar roots combining variations of vertical and horizontal angulations by using X-ray holders (Rinn -XCP), and made a comparison between two types of intraoral radiography systems - conventional film (Kodak Insight, Rochester, USA) and digital radiography (Kodak RVG 6100, Kodak, Rochester, USA). The study sample was comprised of 20 patients with a total of 20 maxillary premolars that were radiographed, using the paralleling angle technique (GP), with a 20º variation of the horizontal angle (GM) and 25º variation of the horizontal angle combined with 15º vertical angle (GMV). Each image was independently analyzed by two experienced examiners. These examiners assigned a score to the diagnostic capability of root dissociation and the measurement of the distance between the apexes. Statistical data was derived using the Wilcoxon Signed Rank test, Friedman and T test. The means of the measured distances between buccal and lingual root apexes were greater for the GMV, which ranged from 2.3 mm to 3.3 mm. A statistically significant difference was found between GM and GMV when compared to GP with p < 0.01. An established best diagnostic dissociation roots image was found in the GMV. These results support the use of the anterior X-ray holders which offer a better combined deviation (GMV) to dissociate maxillary premolar roots in both radiography systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the following acrylic resins: Clássico®, QC-20® and Lucitone®, recommended specifically for thermal polymerization, and Acron MC® and VIPI-WAVE®, made for polymerization by microwave energy. The resins were evaluated regarding their surface nanohardness and modulus of elasticity, while varying the polymerization time recommended by the manufacturer. They were also compared as to the presence of water absorbed by the samples. The technique used was nanoindentation, using the Nano Indenter XP®, MTS. According to an intra-group analysis, when using the polymerization time recommended by the manufacturer, a variation of 0.14 to 0.23 GPa for nanohardness and 2.61 to 3.73 GPa for modulus of elasticity was observed for the thermally polymerized resins. The variation for the resins made for polymerization by microwave energy was 0.15 to 0.22 GPa for nanohardness and 2.94 to 3.73 GPa for modulus of elasticity. The conclusion was that the Classico® resin presented higher nanohardness and higher modulus of elasticity values when compared to those of the same group, while Acron MC® presented the highest values for the same characteristics when compared to those of the same group. The water absorption evaluation showed that all the thermal polymerization resins, except for Lucitone®, presented significant nanohardness differences when submitted to dehydration or rehydration, while only Acron MC® presented no significant differences when submitted to a double polymerization time. Regarding the modulus of elasticity, it was observed that all the tested materials and products, except for Lucitone®, showed a significant increase in modulus of elasticity when submitted to a lack of hydration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A practical method for the structural assignment of 3,4-O-benzylidene-D-ribono-1,5-lactones and analogues using conventional NMR techniques and NOESY measurements in solution is described. 2-O-Acyl-3,4-O-benzylidene-D-ribono-1,5-lactones were prepared in good yields by acylation of Zinner’s lactone with acyl chlorides under mildly basic conditions. Structural determination of 2-O-(4-nitrobenzoyl)-3,4-O-benzylidene-D-ribono-1,5-lactone was achieved by single crystal x-ray diffraction, which supports the results based on spectroscopic data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A total of 316 samples of nasopharyngeal aspirate from infants up to two years of age with acute respiratory-tract illnesses were processed for detection of respiratory syncytial virus (RSV) using three different techniques: viral isolation, direct immunofluorescence, and PCR. Of the samples, 36 (11.4%) were positive for RSV, considering the three techniques. PCR was the most sensitive technique, providing positive findings in 35/316 (11.1%) of the samples, followed by direct immunofluorescence (25/316, 7.9%) and viral isolation (20/315, 6.3%) (p < 0.001). A sample was positive by immunofluorescence and negative by PCR, and 11 (31.4%) were positive only by RT-PCR. We conclude that RT-PCR is more sensitive than IF and viral isolation to detect RSV in nasopharyngeal aspirate specimens in newborn and infants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we discuss the use of photonic crystal fibers (PCFs) as discrete devices for simultaneous wideband dispersion compensation and Raman amplification. The performance of the PCFs in terms of gain, ripple, optical signal-to-noise ratio (OSNR) and required fiber length for complete dispersion compensation is compared with conventional dispersion compensating fibers (DCFs). The main goal is to determine the minimum PCF loss beyond which its performance surpasses a state-of-the-art DCF and justifies practical use in telecommunication systems. (C) 2009 Optical Society of America

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the increased incidence of cancer and a similarly increased number of surgeries for insertion of silicone breast implants, it is necessary to assess the effect of such material within the breast tissue, particularly in mammography, because of the reduction in the power of breast cancer diagnosis. In this work, we introduce a breast phantom with silicone implants in order to evaluate the influence of the implant on the visibility of the main mammographic findings: fibers, microcalcifications and tumor masses. In this proposed phantom, the breast tissue was simulated using gel paraffin. In the optical density of phantom mammograms with implants, a reduction in breast tissue visibility was seen corresponding to 23% when compared to a phantom without silicone implants. This poor visibility was due to the X-ray beam scattering on silicone material; this effect produced a loss of visibility in the areas adjacent to the implant. It is expected that the proposed phantom model may be used as a device for the establishment of a technical standard for these types of procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tomato is amongst the most consumed vegetables in the world, not only for its culinary versatility but also for its high nutritional value. In the last years, consumers have shown an increased concern regarding food origin and safety. The organic tomato production has been a promising alternative for the consumer offering a safer food in relation to environmental, social and nutritional aspects. This study assessed the chemical composition of tomato seeds produced in both conventional and organic systems by INAA. The results showed significant differences (P <= 0.05) in the mass fractions of Br, Cs, Eu, Fe, K, Mo, Na, Rb and Sm between both systems, indicating influence of the crop management adopted in the different tomato production systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This letter shows that the matrix can be used for redundancy and observability analysis of metering systems composed of PMU measurements and conventional measurements (power and voltage magnitude measurements). The matrix is obtained via triangular factorization of the Jacobian matrix. Observability analysis and restoration is carried out during the triangular factorization of the Jacobian matrix, and the redundancy analysis is made exploring the matrix structure. As a consequence, the matrix can be used for metering system planning considering conventional and PMU measurements. These features of the matrix will be outlined and illustrated by numerical examples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A round robin program zoos conducted to assess the ability of three different X-radiographic systems for imaging internal fatigue cracks in riveted lap joints of composite glass reinforced fiber/metal laminate. From an engineering perspective, conventional film radiography and direct radiography have produced the best results, identifying and characterizing in detail internal damage on metallic faying surfaces of fastened glass reinforced fiber/metal laminate joints. On the other hand, computed radiographic images presented large projected geometric distortions and feature shifts due to the angular incident radiation beam, disclosing only partial internal cracking patterns.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ti(6)Al(4)V thin films were grown by magnetron sputtering on a conventional austenitic stainless steel. Five deposition conditions varying both the deposition chamber pressure and the plasma power were studied. Highly textured thin films were obtained, their crystallite size (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using data from a logging experiment in the eastern Brazilian Amazon region, we develop a matrix growth and yield model that captures the dynamic effects of harvest system choice on forest structure and composition. Multinomial logistic regression is used to estimate the growth transition parameters for a 10-year time step, while a Poisson regression model is used to estimate recruitment parameters. The model is designed to be easily integrated with an economic model of decisionmaking to perform tropical forest policy analysis. The model is used to compare the long-run structure and composition of a stand arising from the choice of implementing either conventional logging techniques or more carefully planned and executed reduced-impact logging (RIL) techniques, contrasted against a baseline projection of an unlogged forest. Results from log and leave scenarios show that a stand logged according to Brazilian management requirements will require well over 120 years to recover its initial commercial volume, regardless of logging technique employed. Implementing RIL, however, accelerates this recovery. Scenarios imposing a 40-year cutting cycle raise the possibility of sustainable harvest volumes, although at significantly lower levels than is implied by current regulations. Meeting current Brazilian forest policy goals may require an increase in the planned total area of permanent production forest or the widespread adoption of silvicultural practices that increase stand recovery and volume accumulation rates after RIL harvests. Published by Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The microtube is a simple and cheap emitter that was widely used throughout the world in the early days of drip irrigation. Its length can be adjusted according to the pressure distribution along the lateral line and the discharge from the microtube can be adjusted by its length. This not only counters the pressure loss due to pipe friction but also makes it suitable for undulating and hilly conditions, where pressure in the lateral line varies considerably according to the differences in elevation. This is the major problem facing the designer, i.e., emitter flow changes as the acting pressure head changes. In this study, a novel micro-sprinkler system is proposed that uses microtube as the emitter and where the length of the microtube can be varied in response to pressure changes along the lateral to give uniformity of emitter discharges. The objective of this work is to develop and validate empirical and semi-theoretical equations for the emitter hydraulics. Laboratory testing of two microtube emitters of different diameter over a range of pressures and discharges was used in the development of the equations relating pressure and discharge, and pressure and length for these emitters. The equations proposed will be used in the design of the micro-sprinkler system, to determine the length of microtube required to give the nominal discharge for any given pressure. The semi-theoretical approach underlined the importance of accurate measurements of the microtube diameter and the uncertainty in the estimation of the friction factor for these tubes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to the rapid depletion of water resources, water must be used more efficiently in agriculture to maintain current levels of yield in irrigated areas. The efficiency of irrigation systems can be increased by adjusting the amount of water applied to specific conditions of soil and crop, which may vary in a field. Taking into account spatial and temporal variability, it is evident that an equipment capable of providing different irrigation levels is necessary to meet the water requirement of the soil. This work aims to develop and evaluate a flow rate sprinkler to be used in center pivots or linear moving irrigation systems, with potential for utilization in irrigation scheduling. A prototype was developed by duplicating its calibrations, and discharge coefficient adjustment was carried out in the laboratory. To predict the flow rate, a successful model that represented the operation of the flow rate sprinkler was established. The calibration of the flow rate sprinkler prototype showed satisfactory statistical and technical results. Automation of the prototype was achieved by driving a step motor using communication from the parallel port of a microcomputer, which was controlled by a software developed for this purpose. The results were satisfactory and technically feasible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nitrogen fertilization in common bean crops under no-tillage and conventional systems. Nitrogen fertilizer is necessary for high yields in common bean crops and N responses under conditions of no-tillage and conventional systems are still basic needs. Thus, the objective of this research was to evaluate the effect of N application and common bean yield in no-tillage and conventional systems. The experimental design was a randomized block in a factorial scheme (2x8+1) with four replications. The treatments were constituted by the combination of two N doses (40 and 80 kg ha(-1)) applied at side dressing at eight distinct stadia during vegetative development of the common bean (V(4-3), V(4-4), V(4-5), V(4-6), V(4-7), V(4-8), V(4-9) and V(4-10)), in addition to a control plot without N in side dressing. The experiment was conducted over two years (2002 and 2003) in no-tillage on millet crop residues and conventional plow system. It was concluded that N fertilizer at the V(4) stadium of common bean promotes similar seed yields in no-tillage and conventional systems. Yield differences between no-tillage and conventional systems are inconsistent in the same agricultural area.