16 resultados para cofenetic correlation coefficient

em Universidad de Alicante


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: To evaluate the correlation of the mean curvature and shape factors of both corneal surfaces for different corneal diameters measured with the Scheimpflug photography–based system in keratoconus eyes. Methods: A total of 61 keratoconus eyes of 61 subjects, aged 14 to 64 years, were included in this study. All eyes received a comprehensive ophthalmologic examination including anterior segment and corneal analysis with the Sirius system (CSO): anterior and posterior mean corneal radius for 3, 5, and 7 mm (aKM, pKM), anterior and posterior mean shape factor for 4.5 and 8 mm (ap, pp), central and minimal corneal thickness, and anterior chamber depth. Results: Mean aKM/pKM ratio around 1.20 (range, 0.95–1.48) was found for all corneal diameters (P = 0.24). Weak but significant correlations of this ratio with pachymetric parameters were found (r between −0.28 and −0.34, P < 0.04). The correlation coefficient between aKM and pKM was ≥0.92 for all corneal diameters. A strong and significant correlation was also found between ap and pp (r ≥ 0.86, P < 0.01). The multiple regression analysis revealed that central pKM was significantly correlated with aKM, central corneal thickness, anterior chamber depth, and spherical equivalent (R2 ≥ 0.88, P < 0.01) and that 8 mm pp was significantly correlated with 8 mm ap and age (R2 = 0.89, P < 0.01). Conclusions: Central posterior corneal curvature and shape factor in the keratoconus eye can be consistently predicted from the anterior corneal curvature and shape factor, respectively, in combination with other anatomical and ocular parameters.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introducción: La autopercepción del bienestar dimensional se relaciona con características de cuidadoras. Objetivo: Establecer asociación de autopercepción en dimensiones de bienestar y características de cuidadores. Método: Estudio descriptivo, analítico y correlacional. Muestra 300 cuidadores. Matamoros Tamaulipas, México. Cuestionarios: Datos Sociodemográficos, Índice Barthel, Calidad Vida: dimensiones física, psicológica, social; y espiritual, éste con alpha de Cronbach 0.69. Pruebas chi-cuadrada y coeficiente correlación de Pearson. Resultados: Características mayoría mujeres, 42 años, casadas, hija, alfabetizadas, labores hogar, baja escolaridad, sin trabajo o ingresos limitados. Autopercepción con significancia en bienestar general, alfabetización y parentesco; dimensiones física, edad y género; psicológica, escolaridad; social, parentesco y espiritual alfabetización, situación laboral, ocupación y estado civil. Discusión: Características vulneran a cuidadoras a efectos adversos del cuidado y determinan mayor percepción de carga que altera su bienestar dimensional.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A fast, simple and environmentally friendly ultrasound-assisted dispersive liquid-liquid microextraction (USA-DLLME) procedure has been developed to preconcentrate eight cyclic and linear siloxanes from wastewater samples prior to quantification by gas chromatography-mass spectrometry (GC-MS). A two-stage multivariate optimization approach has been developed employing a Plackett-Burman design for screening and selecting the significant factors involved in the USA-DLLME procedure, which was later optimized by means of a circumscribed central composite design. The optimum conditions were: extractant solvent volume, 13 µL; solvent type, chlorobenzene; sample volume, 13 mL; centrifugation speed, 2300 rpm; centrifugation time, 5 min; and sonication time, 2 min. Under the optimized experimental conditions the method gave levels of repeatability with coefficients of variation between 10 and 24% (n=7). Limits of detection were between 0.002 and 1.4 µg L−1. Calculated calibration curves gave high levels of linearity with correlation coefficient values between 0.991 and 0.9997. Finally, the proposed method was applied for the analysis of wastewater samples. Relative recovery values ranged between 71–116% showing that the matrix had a negligible effect upon extraction. To our knowledge, this is the first time that combines LLME and GC-MS for the analysis of methylsiloxanes in wastewater samples.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A novel method is reported, whereby screen-printed electrodes (SPELs) are combined with dispersive liquid–liquid microextraction. In-situ ionic liquid (IL) formation was used as an extractant phase in the microextraction technique and proved to be a simple, fast and inexpensive analytical method. This approach uses miniaturized systems both in sample preparation and in the detection stage, helping to develop environmentally friendly analytical methods and portable devices to enable rapid and onsite measurement. The microextraction method is based on a simple metathesis reaction, in which a water-immiscible IL (1-hexyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide, [Hmim][NTf2]) is formed from a water-miscible IL (1-hexyl-3-methylimidazolium chloride, [Hmim][Cl]) and an ion-exchange reagent (lithium bis[(trifluoromethyl)sulfonyl]imide, LiNTf2) in sample solutions. The explosive 2,4,6-trinitrotoluene (TNT) was used as a model analyte to develop the method. The electrochemical behavior of TNT in [Hmim][NTf2] has been studied in SPELs. The extraction method was first optimized by use of a two-step multivariate optimization strategy, using Plackett–Burman and central composite designs. The method was then evaluated under optimum conditions and a good level of linearity was obtained, with a correlation coefficient of 0.9990. Limits of detection and quantification were 7 μg L−1 and 9 μg L−1, respectively. The repeatability of the proposed method was evaluated at two different spiking levels (20 and 50 μg L−1), and coefficients of variation of 7 % and 5 % (n = 5) were obtained. Tap water and industrial wastewater were selected as real-world water samples to assess the applicability of the method.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

La temperatura superficial del mar (SST) estimada a partir de los productos 11 μm diurnos y nocturnos y 4 μm nocturnos del sensor MODIS (Moderate Resolution Imaging Spectroradiometer) a bordo de la plataforma Aqua, han sido comparados con datos medidos in situ a tres profundidades diferentes (15, 50 y 100 cm) en una zona costera del Mediterráneo Occidental. Esta comparación ha permitido analizar la incertidumbre que existe en la estimación de este parámetro en aguas someras y próximas a la costa mediante imágenes de satélite de baja resolución espacial. Los resultados obtenidos demuestran que el producto diurno SST_11 μm, obtiene los estadísticos RMSE (error cuadrático medio) y r2 (coeficiente de correlación de Pearson) más ajustados con valores de 1°C y 0,96, respectivamente, para la profundidad 50 cm.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: To evaluate in keratoconus eyes the intrasubject repeatability of anterior and posterior corneal curvature and of other anterior segment anatomic measurements obtained with a new topography system combining Scheimpflug-photography and Placido-disk technology. Setting: Vissum Corporation, Alicante, Spain. Design: Evaluation of technology. Methods: All keratoconus eyes had a comprehensive ophthalmologic examination including analysis with the Sirius system. Three consecutive measurements were obtained to assess the intrasubject repeatability of the following parameters: anterior and posterior corneal curvature and shape factor, white-to-white (WTW) corneal diameter, central and minimum corneal thickness, and anterior chamber depth (ACD). The within-subject standard deviation (Sw) and intraclass correlation coefficient (ICC) were calculated. Results: This study comprised 61 eyes of 61 patients ranging in age from 14 to 64 years. For anterior and posterior corneal curvatures and power vector components, the Sw was 0.29 mm or less in all cases. The ICC was above 0.990 in all cases except the flattest curvature of the posterior corneal surface at 3.0 mm, which was 0.840 (moderate agreement), and the posterior power vector J0, which was 0.665 (poor agreement), 0.752, and 0.758 (moderate agreement) for 3.0 mm, 5.0 mm, and 7.0 mm, respectively. In shape factor measurements, the Sw was 0.12 or less in all cases and the ICC ranged between 0.989 and 0.999. Pachymetry, ACD, and WTW had ICC values very close to 1. Conclusion: The new topography system provided repeatable measurements of corneal shape and other anatomic parameters in eyes with keratoconus.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Power line interference is one of the main problems in surface electromyogram signals (EMG) analysis. In this work, a new method based on the stationary wavelet packet transform is proposed to estimate and remove this kind of noise from EMG data records. The performance has been quantitatively evaluated with synthetic noisy signals, obtaining good results independently from the signal to noise ratio (SNR). For the analyzed cases, the obtained results show that the correlation coefficient is around 0.99, the energy respecting to the pure EMG signal is 98–104%, the SNR is between 16.64 and 20.40 dB and the mean absolute error (MAE) is in the range of −69.02 and −65.31 dB. It has been also applied on 18 real EMG signals, evaluating the percentage of energy respecting to the noisy signals. The proposed method adjusts the reduction level to the amplitude of each harmonic present in the analyzed noisy signals (synthetic and real), reducing the harmonics with no alteration of the desired signal.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: The aim of this study is to determine the reliability of corneal thickness measurements derived from SOCT Copernicus HR (Fourier domain OCT). Methods: Thirty healthy eyes of 30 subjects were evaluated. One eye of each patient was chosen randomly. Images were obtained of the central (up to 2.0 mm from the corneal apex) and paracentral (2.0 to 4.0 mm) cornea. We assessed corneal thickness (central and paracentral) and epithelium thickness. The intra-observer repeatability data were analysed using the intra-class correlation coefficient (ICC) for a range of 95 per cent within-subject standard deviation (SW) and the within-subject coefficient of variation (CW). The level of agreement by Bland–Altman analysis was also represented for the study of the reproducibility between observers and agreement between methods of measurement (automatic versus manual). Results: The mean value of the central corneal thickness (CCT) was 542.4 ± 30.1 μm (SD). There was a high intra-observer agreement, finding the best result in the central sector with an intra-class correlation coefficient of 0.99, 95 per cent CI (0.989 to 0.997) and the worst, in the minimum corneal thickness, with an intra-class correlation coefficient of 0.672, 95 per cent CI (0.417 to 0.829). Reproducibility between observers was very high. The best result was found in the central sector thickness obtained both manually and automatically with an intra-class correlation coefficient of 0.990 in both cases and the worst result in the maximum corneal thickness with an intra-class correlation coefficient of 0.827. The agreement between measurement methods was also very high with intra-class correlation coefficient greater than 0.91. On the other hand the repeatability and reproducibility for epithelial measurements was poor. Conclusion: Pachymetric mapping with SOCT Copernicus HR was found to be highly repeatable and reproducible. We found that the device lacks an appropriate ergonomic design as proper focusing of the laser beam onto the cornea for anterior segment scanning required that patients were positioned slightly farther away from the machine head-rest than in the setup for retinal imaging.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of this paper is to analyze the quasi-elastic deformational behavior that has been induced by groundwater withdrawal of the Tertiary detrital aquifer of Madrid (Spain). The spatial and temporal evolution of ground surface displacement was estimated by processing two datasets of radar satellite images (SAR) using Persistent Scatterer Interferometry (PSI). The first SAR dataset was acquired between April 1992 and November 2000 by ERS-1 and ERS-2 satellites, and the second one by the ENVISAT satellite between August 2002 and September 2010. The spatial distribution of PSI measurements reveals that the magnitude of the displacement increases gradually towards the center of the well field area, where approximately 80 mm of maximum cumulated displacement is registered. The correlation analysis made between displacement and piezometric time series provides a correlation coefficient greater than 85% for all the wells. The elastic and inelastic components of measured displacements were separated, observing that the elastic component is, on average, more than 4 times the inelastic component for the studied period. Moreover, the hysteresis loops on the stress–strain plots indicate that the response is in the elastic range. These results demonstrate the quasi-elastic behavior of the aquifer. During the aquifer recovery phase ground surface uplift almost recovers from the subsidence experienced during the preceding extraction phase. Taking into account this unique aquifer system, a one dimensional elastic model was calibrated in the period 1997–2000. Subsequently, the model was used to predict the ground surface movements during the period 1992–2010. Modeled displacements were validated with PSI displacement measurements, exhibiting an error of 13% on average, related with the inelastic component of deformation occurring as a long-term trend in low permeability fine-grained units. This result further demonstrates the quasi-elastic deformational behavior of this unique aquifer system.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A novel approach is presented, whereby gold nanostructured screen-printed carbon electrodes (SPCnAuEs) are combined with in-situ ionic liquid formation dispersive liquid–liquid microextraction (in-situ IL-DLLME) and microvolume back-extraction for the determination of mercury in water samples. In-situ IL-DLLME is based on a simple metathesis reaction between a water-miscible IL and a salt to form a water-immiscible IL into sample solution. Mercury complex with ammonium pyrrolidinedithiocarbamate is extracted from sample solution into the water-immiscible IL formed in-situ. Then, an ultrasound-assisted procedure is employed to back-extract the mercury into 10 µL of a 4 M HCl aqueous solution, which is finally analyzed using SPCnAuEs. Sample preparation methodology was optimized using a multivariate optimization strategy. Under optimized conditions, a linear range between 0.5 and 10 µg L−1 was obtained with a correlation coefficient of 0.997 for six calibration points. The limit of detection obtained was 0.2 µg L−1, which is lower than the threshold value established by the Environmental Protection Agency and European Union (i.e., 2 µg L−1 and 1 µg L−1, respectively). The repeatability of the proposed method was evaluated at two different spiking levels (3 and 10 µg L−1) and a coefficient of variation of 13% was obtained in both cases. The performance of the proposed methodology was evaluated in real-world water samples including tap water, bottled water, river water and industrial wastewater. Relative recoveries between 95% and 108% were obtained.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

As the water vapor content in the atmosphere scales with temperature, a warmer world is expected to feature an intensification of the hydrological cycle. Work to date has mainly focused on mean precipitation changes, whose connection to climatic modes is elusive at a global scale. Here we show that continental precipitation annual amplitude, which represents the annual range between minimum and maximum (monthly) rainfall, covaries with a linear combination of the Atlantic Multidecadal Oscillation and low-frequency variations in the El Niño–Southern Oscillation on a decadal to multidecadal scale with a correlation coefficient of 0.92 (P<0.01). The teleconnection is a result of changes in moisture transport in key regions. Reported trends in the annual amplitude of global precipitation in recent decades need to be assessed in light of this substantial low-frequency variability, which could mask or enhance an anthropogenic signal in hydrological cycle changes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction. To date, no rating scales for detecting apathy in Parkinson’s disease (PD) patients have been validated in Spanish. For this reason, the aim of this study was to validate a Spanish version of Lille apathy rating scale (LARS) in a cohort of PD patients from Spain. Participants and Methods. 130 PD patients and 70 healthy controls were recruited to participate in the study. Apathy was measured using the Spanish version of LARS and the neuropsychiatric inventory (NPI). Reliability (internal consistency, test-retest, and interrater reliability) and validity (construct, content, and criterion validity) were measured. Results. Interrater reliability was 0.93. Cronbach’s α for LARS was 0.81. The test-retest correlation coefficient was 0.97. The correlation between LARS and NPI scores was 0.61. The optimal cutoff point under the ROC curve was , whereas the value derived from healthy controls was . The prevalence of apathy in our population tested by LARS was 42%. Conclusions. The Spanish version of LARS is a reliable and useful tool for diagnosing apathy in PD patients. Total LARS score is influenced by the presence of depression and cognitive impairment. However, both disorders are independent identities with respect to apathy. The satisfactory reliability and validity of the scale make it an appropriate instrument for screening and diagnosing apathy in clinical practice or for research purposes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Cette approche histométrique traite la description des tissus constituants les êtres vivants de deux espèces végétales vivaces (Lygeum spartum et Ammophila arenaria). Elle permettra d’aider à comprendre certainement le comportement tant morphologique que physiologique de l’espèce vivante dans un biotope naturel. Présentant des racines adaptatives à l’absorption de l’eau et des sels minéraux du sol, ces deux espèces montrent une fixation de la plante au substrat et à l’accumulation des réserves. Elles sont sous la dépendance de corrélations com plexes (trophiques, hormonales) qui s’établissent entre l’appareil souterrain et l’appareil aérien. L’étude histométrique du Lygeum spartum et d’Ammophila arenaria nous a permis de déterminer une nette différence entre les tissus des deux espèces. Pour Ammophila arenaria, il existe de très bonnes corrélations pour la majorité des tissus, expliquant ainsi une croissance cellulaire qui existe entre ces différents tissus.Le coefficient de corrélation est faible entre les différents tissus du Lygeum spartum. Le développment des tissus de celle-ci n’est pas synchrone, il montre toute même une certaine hétérogéneité au niveau du développement tissulaire des racines.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundamentos: El Physician Readiness to Manage Intimate Partner Violence Survey (PREMIS) es uno de los cuestionarios más completos en el contexto internacional para la valoración de la capacidad de respuesta frente a la violencia del compañero íntimo por los profesionales de Atención Primaria de Salud. El objetivo de este estudio fue determinar la fiabilidad, consistencia interna y validez de constructo de la versión española de este cuestionario. Métodos: Tras la traducción, retrotraducción y valoración de la validez de contenido del cuestionario, se distribuyeron en una muestra de 200 profesionales de medicina y enfermería de 15 centros de atención primaria de 4 Comunidades Autónomas en 2013 (Comunidad Valenciana, Castilla León, Murcia y Cantabria). Se calcularon los coeficientes alfa de Cronbach, los de correlación intraclase y rho de Spearman (test-retest). Resultados: la versión española del PREMIS incluyó 64 ítems. El coeficiente α de Cronbach fue superior a 0,7 o muy cercano a ese valor en la mayoría de los índices. Se obtuvo un coeficiente de correlación intraclase de 0,87 y un coeficiente de Spearman de 0,67 que muestran una fiabilidad alta. Todas las correlaciones observadas para la escala de opiniones, la única tratada como estructura factorial en el cuestionario PREMIS, fueron superiores a 0,30. Conclusiones: el PREMIS en español obtuvo una buena validez interna, alta fiabilidad y capacidad predictiva de las prácticas auto-referidas por médicos(as) y enfermeros(as) frente a casos de violencia del compañero íntimo en centros de atención primaria.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objectives: To design and validate a questionnaire to measure visual symptoms related to exposure to computers in the workplace. Study Design and Setting: Our computer vision syndrome questionnaire (CVS-Q) was based on a literature review and validated through discussion with experts and performance of a pretest, pilot test, and retest. Content validity was evaluated by occupational health, optometry, and ophthalmology experts. Rasch analysis was used in the psychometric evaluation of the questionnaire. Criterion validity was determined by calculating the sensitivity and specificity, receiver operator characteristic curve, and cutoff point. Testeretest repeatability was tested using the intraclass correlation coefficient (ICC) and concordance by Cohen’s kappa (k). Results: The CVS-Q was developed with wide consensus among experts and was well accepted by the target group. It assesses the frequency and intensity of 16 symptoms using a single rating scale (symptom severity) that fits the Rasch rating scale model well. The questionnaire has sensitivity and specificity over 70% and achieved good testeretest repeatability both for the scores obtained [ICC 5 0.802; 95% confidence interval (CI): 0.673, 0.884] and CVS classification (k 5 0.612; 95% CI: 0.384, 0.839). Conclusion: The CVS-Q has acceptable psychometric properties, making it a valid and reliable tool to control the visual health of computer workers, and can potentially be used in clinical trials and outcome research.